Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Ca...Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD), and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by ther-modilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.展开更多
目的比较经典式原位肝移植手术对CO2部分重吸入法和持续温度稀释法测定心排血量(CO)的影响。方法行经典式原位肝移植手术患者14例,于手术探查,门静脉阻断即刻和阻断后15、30 m in,开放即刻和开放后15、30、60 m in各时间点,分别用CO2部...目的比较经典式原位肝移植手术对CO2部分重吸入法和持续温度稀释法测定心排血量(CO)的影响。方法行经典式原位肝移植手术患者14例,于手术探查,门静脉阻断即刻和阻断后15、30 m in,开放即刻和开放后15、30、60 m in各时间点,分别用CO2部分重吸入法和持续温度稀释法测定CO(RBCO和TDCO),将结果进行比较。结果RBCO和TDCO在门静脉阻断后都呈下降趋势,最低值出现于阻断15 m in时,开放后则明显升高,TDCO的升幅大于RBCO,并一直处于上升趋势中,而RBCO在开放15 m in时有一回落。除开放15 m in时间点以外,各时间点RBCO均显著低于TDCO(P<0.01)。各时间点TDCO与RBCO的相关性检验均有统计学意义(P<0.001)。结论在经典式原位肝移植手术中,CO2部分重吸入法所测得的CO普遍低于持续温度稀释法所测值,但发展趋势相似,两者之间相关性良好。展开更多
文摘Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD), and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by ther-modilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.
文摘目的比较经典式原位肝移植手术对CO2部分重吸入法和持续温度稀释法测定心排血量(CO)的影响。方法行经典式原位肝移植手术患者14例,于手术探查,门静脉阻断即刻和阻断后15、30 m in,开放即刻和开放后15、30、60 m in各时间点,分别用CO2部分重吸入法和持续温度稀释法测定CO(RBCO和TDCO),将结果进行比较。结果RBCO和TDCO在门静脉阻断后都呈下降趋势,最低值出现于阻断15 m in时,开放后则明显升高,TDCO的升幅大于RBCO,并一直处于上升趋势中,而RBCO在开放15 m in时有一回落。除开放15 m in时间点以外,各时间点RBCO均显著低于TDCO(P<0.01)。各时间点TDCO与RBCO的相关性检验均有统计学意义(P<0.001)。结论在经典式原位肝移植手术中,CO2部分重吸入法所测得的CO普遍低于持续温度稀释法所测值,但发展趋势相似,两者之间相关性良好。