期刊文献+
共找到30篇文章
< 1 2 >
每页显示 20 50 100
Parameter Design of Current Double Closed Loop for T-Type Three-Level Grid-Connected Inverter
1
作者 Tiankui Sun Mingming Shi +3 位作者 Xiaolong Xiao Ping He Yu Ji Zhiyuan Yuan 《Energy Engineering》 EI 2023年第7期1621-1636,共16页
To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control a... To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control and the failure to eliminate the influence of the LCL filter on the grid-connected current by using current PI control alone,a current double closed loop PI current tracking control is proposed.Through the theoretical analysis of the grid-connected inverter control principle,the grid-connected inverter control model is designed,and the transfer functionmodel of each control link is deduced,and the current loop PI regulator is designed at last.The simulation results show that the control strategy is feasible. 展开更多
关键词 T-type inverter active damping current double closed loop
下载PDF
Synthesis identification analysis for closed loop system
2
作者 WANG Jianhong RICARDO A.Ramirez-Mendoza 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2021年第4期939-946,共8页
The existing theories for closed loop identification with the linear feedback controller are very mature.To apply the existed theories directly in the control field,we propose a new idea about replacing the original u... The existing theories for closed loop identification with the linear feedback controller are very mature.To apply the existed theories directly in the control field,we propose a new idea about replacing the original unknown and nonlinear feedback controller with one approximated linear controller,while guaranteeing the equivalent property for the obtained closed loop system.Based on some statistical correlation functions,one condition is derived to show the equivalent property between the approximated linear controller and the original nonlinear controller.The detailed explicit form,corresponding to the approximated linear controller,is also constructed.Furthermore,to give a complete analysis for closed loop identification,the cost function is rewritten as one extended expression,being convenient to understand.Then spectral estimation is introduced to identify the unknown plant in the closed loop system.Finally,the proposed theories are verified by one simulation example. 展开更多
关键词 synthesis analysis closed loop system simplified function equivalent controller
下载PDF
STEERING SAFETY EVALUATION OF DRIVER VEHICLE CLOSED LOOP SYSTEM WITH RANDOM ROAD INPUT 被引量:1
3
作者 Zhao Youqun Shandong Institute of Technology Guo Konghui Zhang Guiyu Jilin University of Technology Shandong Institute of Technology 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 1999年第4期282-287,共6页
The response simulation is studied and the steering safety is evaluated by using finer integration method for driver vehicle closed loop system with stationary random road input.This algorithm not only is precise, b... The response simulation is studied and the steering safety is evaluated by using finer integration method for driver vehicle closed loop system with stationary random road input.This algorithm not only is precise, but also can shorten the evaluation period of steering safety and reduce the tremendous cost for real vehicle testing.The response simulation and the vehicle steering safety evaluation are also studied for the closed loop system with evolutionary random road input.The study can more truly evaluate vehicle driving for including the slowly varying of vehicle velocity with time. 展开更多
关键词 closed loop system Evaluation Random Safety Vehicle steer ability
全文增补中
Recent Advances in Closed Loop Spray Cooling and its Application in Airborne Systems 被引量:3
4
作者 XU Xinjie WANG Yu +2 位作者 JIANG Yanlong LIU Jinxiang YUAN Xiaolei 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第1期32-50,共19页
In recent years,the problem of heat dissipation in airborne directed energy weapons has attracted considerable research interest.Spray cooling can be applied to cool airborne directed energy weapons,owing to its sever... In recent years,the problem of heat dissipation in airborne directed energy weapons has attracted considerable research interest.Spray cooling can be applied to cool airborne directed energy weapons,owing to its several advantages such as a large heat transfer coefficient,absence of boiling hysteresis and uniform surface temperature.To examine the potential of an airborne spray cooling system,the typical high heat flux dissipation methods were compared,and the state of the art research on spray cooling was reviewed.This review was focused on studies related to the spray cooling hydrodynamic mechanism,experimental studies of closed loop spray cooling,numerical simulation studies about spray cooling and the identification of the factors influencing spray cooling systems,and investigations related to the multiple nozzle spray cooling technology and heat transfer correlation predictions.Overall,there is a need for further research to investigate the failure phenomenon after the critical state,matching operation of the total system and microscopic characteristics of airborne specific parameters. 展开更多
关键词 spray cooling closed loop heat transfer performance influencing factor CORRELATIONS
原文传递
Phase-dependent inversionless gain in a four-level atomic system with a closed interaction loop 被引量:2
5
作者 徐卫华 吴金辉 高锦岳 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第2期441-448,共8页
A four-level atomic system with a closed interaction loop connected by two coherent driving fields and a microwave field is investigated. The results show that inversionless gain can be achieved on a higher frequency ... A four-level atomic system with a closed interaction loop connected by two coherent driving fields and a microwave field is investigated. The results show that inversionless gain can be achieved on a higher frequency transition outside the closed interaction loop, and the gain behaviour can be modulated by the phase of the closed loop as well as the amplitude of the microwave field. The phase sensitivity property in such a scheme is similar to that in an analogous configuration with spontaneously generated coherence, but it is beyond the rigorous condition of near-degenerate levels with non-orthogonal dipole moments. Therefore this scheme is much more convenient in experimental realization. 展开更多
关键词 inversionless gain microwave field closed interaction loop PHASE
下载PDF
Study on a Closed-Loop Air-Fuel Control System of Gasoline Engines by Simulation
6
作者 张付军 赵长禄 +1 位作者 黄英 郝利军 《Journal of Beijing Institute of Technology》 EI CAS 2003年第3期296-301,共6页
In order to study the factors that influence the air fuel ratio(A/F), the amplitude and frequency of A/F fluctuation, to reform the control strategy, and to improve the efficiency of three way catalyst(TWC), a model... In order to study the factors that influence the air fuel ratio(A/F), the amplitude and frequency of A/F fluctuation, to reform the control strategy, and to improve the efficiency of three way catalyst(TWC), a model of closed loop control system including the engine, air fuel mixing and transportation, oxygen sensor and controller, etc., is developed. Various factors that influence the A/F control are studied by simulation. The simulation results show that the reference voltage of oxygen sensor will influence the mean value of A/F ratio, the controller parameters will influence the amplitude of A/F fluctuation, and the operating conditions of the engine determine the frequency of A/F fluctuations, the amplitude of A/F fluctuation can be reduced to within demanded values by logical selection of the signal acquisition method and controller parameters. Higher A/F fluctuation frequency under high speed and load can be reduced through software delay in the controller. The A/F closed loop control system based on the simulation results, accompanied with a rare earth element TWC, gives a better efficiency of conversion against harmful emissions. 展开更多
关键词 air fuel ratio closed loop control SIMULATION
下载PDF
Artificial intelligence powered glucose monitoring and controlling system:Pumping module
7
作者 Sravani Medanki Nikhil Dommati +7 位作者 Hema Harshitha Bodapati Venkata Naga Sai Kowsik Katru Gollapalli Moses Abhishek Komaraju Nanda Sai Donepudi Dhanya Yalamanchili Jasti Sateesh Pratap Turimerla 《World Journal of Experimental Medicine》 2024年第1期100-112,共13页
BACKGROUND Diabetes,a globally escalating health concern,necessitates innovative solutions for efficient detection and management.Blood glucose control is an essential aspect of managing diabetes and finding the most ... BACKGROUND Diabetes,a globally escalating health concern,necessitates innovative solutions for efficient detection and management.Blood glucose control is an essential aspect of managing diabetes and finding the most effective ways to control it.The latest findings suggest that a basal insulin administration rate and a single,highconcentration injection before a meal may not be sufficient to maintain healthy blood glucose levels.While the basal insulin rate treatment can stabilize blood glucose levels over the long term,it may not be enough to bring the levels below the post-meal limit after 60 min.The short-term impacts of meals can be greatly reduced by high-concentration injections,which can help stabilize blood glucose levels.Unfortunately,they cannot provide long-term stability to satisfy the postmeal or pre-meal restrictions.However,proportional-integral-derivative(PID)control with basal dose maintains the blood glucose levels within the range for a longer period.AIM To develop a closed-loop electronic system to pump required insulin into the patient's body automatically in synchronization with glucose sensor readings.METHODS The proposed system integrates a glucose sensor,decision unit,and pumping module to specifically address the pumping of insulin and enhance system effectiveness.Serving as the intelligence hub,the decision unit analyzes data from the glucose sensor to determine the optimal insulin dosage,guided by a pre-existing glucose and insulin level table.The artificial intelligence detection block processes this information,providing decision instructions to the pumping module.Equipped with communication antennas,the glucose sensor and micropump operate in a feedback loop,creating a closed-loop system that eliminates the need for manual intervention.RESULTS The incorporation of a PID controller to assess and regulate blood glucose and insulin levels in individuals with diabetes introduces a sophisticated and dynamic element to diabetes management.The simulation not only allows visualization of how the body responds to different inputs but also offers a valuable tool for predicting and testing the effects of various interventions over time.The PID controller's role in adjusting insulin dosage based on the discrepancy between desired setpoints and actual measurements showcases a proactive strategy for maintaining blood glucose levels within a healthy range.This dynamic feedback loop not only delays the onset of steady-state conditions but also effectively counteracts post-meal spikes in blood glucose.CONCLUSION The WiFi-controlled voltage controller and the PID controller simulation collectively underscore the ongoing efforts to enhance efficiency,safety,and personalized care within the realm of diabetes management.These technological advancements not only contribute to the optimization of insulin delivery systems but also have the potential to reshape our understanding of glucose and insulin dynamics,fostering a new era of precision medicine in the treatment of diabetes. 展开更多
关键词 DIABETES HYPERGLYCEMIA INSULIN MICROPUMP closed loop systems Artificial intelligence automation
下载PDF
Method with reliable accuracy and fast speed for measuring operational current of HTS NI closed-loop coils in steady persistent-current-mode
8
作者 Li Lu Wei Wu +5 位作者 Xin Yu Zhuoyan Zhong Kai Li Chengyun Pan Mengzhu Li Zhijian Jin 《Superconductivity》 2024年第1期65-73,共9页
This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed... This study proposes a method for measuring the operational current of high temperature superconducting(HTS)non‐insulation(NI)closed‐loop coils,which operate in the steady persistent‐current‐mode(PCM).HTS NI closed‐loop coils are promising for many easily‐quenching direct‐current(DC)applications,where their performance is determined by magnetomotive forces,total number of turns,and dimensions.As the primary interface parameter in an application system,the operational current must be accurately and rapidly measured.Generally,this is achieved by dividing the measured magnetic field by the coil constant.However,even if the influence of the screening current induced field(SCIF)is not considered,existing methods for the coil constant may be disturbed by the performance and location of Hall sensors,or experience a long measuring period.Therefore,a relatively accurate and fast method is proposed in this study,which is based on adjusting the output current of the adjustable power supply and monitoring the coil voltage as an indicator.The proposed method was validated through experiments and simulations using an equivalent circuit model coupled with a finite element method(FEM)model,and its current accuracy can be equivalent to the resolution of the employed power supply.It was demonstrated that this method reduced the requirements for Hall sensor’s performance and location,and has a more reliable accuracy in contrast to the simulation method.Compared to the experimentally conventional method,the proposed method presents a significantly faster speed.The impact of the SCIF was considered and proven to be negligible for the tested pancake coils.Even for coils whose coil constant vibrates owing to the SCIF,this method can be adapted to directly measure various operational currents.Furthermore,it was demonstrated that the measurement error can be influenced by the current discrepancy among turns when the coil is not in the steady PCM,and a procedure for reducing this error was proposed. 展开更多
关键词 Operational current HTS NI closedloop coils Measurement method Adjustable power supply Coil voltage
原文传递
UAV target tracking algorithm based on task allocation consensus 被引量:3
9
作者 Yani Cui Jia Ren +1 位作者 Wencai Du Jingguo Dai 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2016年第6期1207-1218,共12页
In order to adapt to the changes in the states of moving targets and meet the requirements of quality of service in communication among unmanned aerial vehicles (UAVs), the UAVs formation needs to dynamically adjust t... In order to adapt to the changes in the states of moving targets and meet the requirements of quality of service in communication among unmanned aerial vehicles (UAVs), the UAVs formation needs to dynamically adjust tracking tasks and tracking paths, when they carry out a mission of tracking multiple moving targets. A multi-targets tracking algorithm based on task allocation consensus is proposed for UAVs to track multiple moving targets under the distributed control architecture in the limited communication range. This algorithm creates a distributed dynamic task allocation model using intermittent asynchronous communication principle to realize the sharing of observation information gathered by each UAV with fewer communications. In addition, this algorithm also makes it possible that multi-UAVs can plan tracking paths for multiple moving targets. We implement the algorithm on the formation with three UAVs to track three moving targets through simulation. Simulation results show the effectiveness of the proposed algorithm. ? 2016 Beijing Institute of Aerospace Information. 展开更多
关键词 closed loop control systems Motion planning Quality of service Tracking (position) Unmanned aerial vehicles (UAV) Vehicle to vehicle communications
下载PDF
Early diagnosis of bowel obstruction and strangulation by computed tomography in emergency department 被引量:3
10
作者 Sohil Pothiawala Apoorva Gogna 《World Journal of Emergency Medicine》 CAS 2012年第3期227-231,共5页
BACKGROUND:Closed loop bowel obstruction is a specific type of mechanical obstruction with a high risk of strangulation and bowel infarction,especially in the small bowel.It is associated with a high mortality rate.He... BACKGROUND:Closed loop bowel obstruction is a specific type of mechanical obstruction with a high risk of strangulation and bowel infarction,especially in the small bowel.It is associated with a high mortality rate.Hence,it is important for emergency physicians to identify the presence of strangulation,while making the diagnosis of closed loop small bowel obstruction.METHODS:We reported three patients with strangulated closed loop small bowel obstruction associated with severe abdominal pain,who had been treated at the emergency department.Urgent computerized tomography was performed in the patients.RESULTS:Two patients were discharged with stable conditions,and one patient died after hemodialysis.CONCLUSION:Urgent computerized tomography of the abdomen serves as an important diagnostic tool in view of its ability to detect the site,level and cause of obstruction along with the distinctive CT appearance of closed loop small bowel obstruction and signs of ischemia.Early definitive diagnosis will guide subsequent management and improve outcomes. 展开更多
关键词 closed loop small bowel obstruction Computed tomography ISCHEMIA STRANGULATION
下载PDF
Adaptive Robust Control for A Class of Nonlinear Systems with Unknown Uncertainties 被引量:1
11
作者 Li, L. Yang, G. Zhao, C. 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第3期51-56,共6页
The problem of robust stabilization for nonlinear systems with partially known uncertainties is considered in this paper. The required information about uncertainties in the system is merely that the uncertainties are... The problem of robust stabilization for nonlinear systems with partially known uncertainties is considered in this paper. The required information about uncertainties in the system is merely that the uncertainties are bounded, but the upper bounds are incompletely known. This paper can be viewed as an extension of the work in reference [1]. To compensate the uncertainties, an adaptive robust controller based on Lyapunov method is proposed and the design algorithm is also suggested. Compared with some previous controllers which can only ensure ultimate uniform boundedness of the systems, the controller given in the paper can make sure that the obtained closed-loop system is asymptotically stable in the large. Simulations show that the method presented is available and effective. 展开更多
关键词 Adaptive algorithms Adaptive control systems Asymptotic stability closed loop control systems Computer simulation Interfaces (computer) Lyapunov methods Robustness (control systems) Uncertain systems
下载PDF
Rectifying control of wire diameter during dieless drawing by a deformation measuring method of interframe displacement
12
作者 Yong He Xue-feng Liu Fang Qin Jian-xin Xie 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2012年第7期615-621,共7页
A deformation measurement method of interframe displacement was proposed in this paper. By online monitoring the shape di- mensions of both the deformation zone and its adjacent zone by machine vision, the initial and... A deformation measurement method of interframe displacement was proposed in this paper. By online monitoring the shape di- mensions of both the deformation zone and its adjacent zone by machine vision, the initial and terminative positions of deformation were dynamically identified during dieless drawing, and the global monitoring and online closed-loop control of the deformation zone were achieved. The dieless drawing process was systematically carried out on NiTi shape memory alloy wires. It is shown that the deformation measurement method of interframe displacement can track the axial displacement of the wires, but this cannot be achieved by traditional machine vision. The initial and terminative positions of deformation can be accurately identified by this method. The proposed rectifying control technology can effectively decrease the wire diameter fluctuation during dieless drawing, that is, the standard deviation of the wire diameter fluctuation could be decreased fi'om 0.30 to 0.08 mm after three passes of dieless drawing, indicating that the control system has a good rectifying ability. 展开更多
关键词 wire drawing RECTIFICATION DEFORMATION machine vision closed loop control systems nickel alloys sha^oe memory effect
下载PDF
Robust H_∞ Stabilization of Uncertain Linear Time-Delay System with Delayed/Undelayed State Feedback Controllers
13
作者 陈万义 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第4期71-76,共6页
This paper focuses on the H∞ controller design for linear systems with time-varying delays and norm-bounded parameter perturbations in the system state and control/disturbance. On the existence of delayed/undelayed f... This paper focuses on the H∞ controller design for linear systems with time-varying delays and norm-bounded parameter perturbations in the system state and control/disturbance. On the existence of delayed/undelayed full state feedback controllers, we present a sufficient condition and give a design method in the form of Riccati equation. The controller can not only stabilize the time-delay system, but also make the H∞ norm of the closed-loop system be less than a given bound. This result practically generalizes the related results in current literature. 展开更多
关键词 closed loop control systems Feedback control Linear control systems Perturbation techniques Riccati equations Robustness (control systems) State feedback System stability Time varying control systems Uncertain systems
下载PDF
Design of an Interpolated Controller for Stabilization of a Plant with Variable Operating Condition
14
作者 Yuan, Xiangyang Shi, Songjiao Ikeda, Masao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2000年第2期39-47,共9页
In this paper, the stabilization of a linear SISO plant with variable operating condition is considered. The plant is described by a linear interpolation of proper stable co-prime factorizations of the transfer functi... In this paper, the stabilization of a linear SISO plant with variable operating condition is considered. The plant is described by a linear interpolation of proper stable co-prime factorizations of the transfer functions at two representative operating points. An interpolation of the stabilizing controllers for the representative models is designed to stabilize the plant, and the necessary and sufficient condition for the plant to be stabilized by the proposed controller is presented using the Nevanlinna-Pick interpolation theory. It is shown that the class of stabilization plants via the proposed controller in the paper is larger than that by the controller in reference. An example is also given to illustrate this fact. 展开更多
关键词 closed loop control systems Control system analysis INTERPOLATION System stability Transfer functions
下载PDF
Adaptive Server Load Balancing in SDN Using PID Neural Network Controller
15
作者 R.Malavika M.L.Valarmathi 《Computer Systems Science & Engineering》 SCIE EI 2022年第7期229-243,共15页
Web service applications are increasing tremendously in support of high-level businesses.There must be a need of better server load balancing mechanism for improving the performance of web services in business.Though ... Web service applications are increasing tremendously in support of high-level businesses.There must be a need of better server load balancing mechanism for improving the performance of web services in business.Though many load balancing methods exist,there is still a need for sophisticated load bal-ancing mechanism for not letting the clients to get frustrated.In this work,the ser-ver with minimum response time and the server having less traffic volume were selected for the aimed server to process the forthcoming requests.The Servers are probed with adaptive control of time with two thresholds L and U to indicate the status of server load in terms of response time difference as low,medium and high load by the load balancing application.Fetching the real time responses of entire servers in the server farm is a key component of this intelligent Load balancing system.Many Load Balancing schemes are based on the graded thresholds,because the exact information about the networkflux is difficult to obtain.Using two thresholds L and U,it is possible to indicate the load on particular server as low,medium or high depending on the Maximum response time difference of the servers present in the server farm which is below L,between L and U or above U respectively.However,the existing works of load balancing in the server farm incorporatefixed time to measure real time response time,which in general are not optimal for all traffic conditions.Therefore,an algorithm based on Propor-tional Integration and Derivative neural network controller was designed with two thresholds for tuning the timing to probe the server for near optimal perfor-mance.The emulation results has shown a significant gain in the performance by tuning the threshold time.In addition to that,tuning algorithm is implemented in conjunction with Load Balancing scheme which does not tune thefixed time slots. 展开更多
关键词 Software defined networks PID neural network controller closed loop control theory server load balancing server response time
下载PDF
A research of arc welding inverter with high stable precision
16
作者 魏巍 蒲春华 《China Welding》 EI CAS 2002年第2期151-155,共5页
This paper mainly introduces an output control method with high stable precision of a large power IGBT arc welding inverter. Experiments indicate that this kind of control mode can effectively improve the static and d... This paper mainly introduces an output control method with high stable precision of a large power IGBT arc welding inverter. Experiments indicate that this kind of control mode can effectively improve the static and dynamic characteristics and stability of power supply system. And it can decrease the spatters in the welding process apparently. This power supply is especially suitable to automatic robot welding assembly line. It will be the developing direction of robot welding supply in the future. 展开更多
关键词 arc welding inverter high stable precision bi closed loop feedback control
下载PDF
Power Control Based on State Space Strategies for Grid⁃Oriented Inverters with LCL Filters
17
作者 Chunyu Lu Wei Hua Mingjin Hu 《Journal of Harbin Institute of Technology(New Series)》 CAS 2022年第2期1-12,共12页
Through a third⁃order mathematical model of grid⁃oriented LCL⁃type converters,this paper analyzes the complicated dynamic characteristics and resonance problems which may influence the system stability.To realize acti... Through a third⁃order mathematical model of grid⁃oriented LCL⁃type converters,this paper analyzes the complicated dynamic characteristics and resonance problems which may influence the system stability.To realize active damping for LCL filters and improve dynamic performance of current regulators,a state space current PI controller is proposed whose parameters can be tuned based on the polynomial equations approach.An extended state observer is integrated with the regulation scheme,where additional sensors are not necessary in contrast with conventional active damping strategies.Synchronous reference frame PLL(SRF⁃PLL)equipped with filter technology is proposed for grid voltage disturbance suppression.This method is then applied to establish a double⁃closed⁃loop power regulator that demonstrates improved performance compared with other controllers.The simulation results are displayed to illustrate the efficiency of the regulation methods. 展开更多
关键词 LCL⁃type grid⁃oriented converters state space current control SRF⁃PLL closed loop power control
下载PDF
Controlling Chaotic Cscillations with Input-Output Linearization
18
作者 CHEN Li qun Institute of Applied Mathematics and Mechanics, Shanghai University, Shanghai 200072, China 《Advances in Manufacturing》 2000年第3期175-178,共4页
In this paper, the nonlinear control of chaotic oscillations was investigated by using the input output linearization control method. The chaotic attitude of a kind of spacecraft was discussed. It is demonstrated that... In this paper, the nonlinear control of chaotic oscillations was investigated by using the input output linearization control method. The chaotic attitude of a kind of spacecraft was discussed. It is demonstrated that the input output linearization control law is the nonlinear version of the parametric open plus closed loop control law. 展开更多
关键词 controlling chaos nonlinear oscillation input output linearization parametric open plus closed loop control
下载PDF
闭环液压系统及其对驱动器设计的影响
19
作者 Karan Sotoodeh 《Journal of Marine Science and Application》 CSCD 2021年第2期333-342,共10页
Hydraulic systems provide a clean and stable supply of hydraulic fluid for subsea valves and actuators installed on the subsea bed in subsea production systems.Subsea control systems are used for contemporary subsea f... Hydraulic systems provide a clean and stable supply of hydraulic fluid for subsea valves and actuators installed on the subsea bed in subsea production systems.Subsea control systems are used for contemporary subsea fields instead of installing the control system on topside.Although all-electric subsea systems are state-of-the-art with benefits such as health,safety,and environment improvement,as well as efficiency and lower cost,hydraulic systems are still used for the development of many subsea fields.One of the main questions in the selection of a subsea hydraulic field is whether to choose an open or closed loop hydraulic system.The main characteristic of an open loop hydraulic system is that the hydraulic fluid is discharged into the marine environment during the actuation of the subsea valves.Conversely,the hydraulic fluid is returned to the topside facilities through an umbilical system in a closed loop system.Given that closed loop systems are more eco-friendly,the main question in this research is to examine the effect of the actuator connection of the closed loop system on actuator design.Two cases of actuated valves connected to a closed loop system are analyzed in this paper.The first is a 71/16-in.subsea slab gate valve in the pressure class of 517 bar with a linear spring return fail-safe close(FSC)actuator located on a manifold branch.The data indicates that the piston rod and cylinder diameter of the FSC linear actuator should be increased by some millimeters due to the accumulation of hydraulic oil at the bottom of the actuator.The hydraulic oil in the closed loop system helps in closing the actuator and spring force,so the spring constant and torque should be reduced as a result.The second case involves a 16-in.subsea ball valve in the pressure class of 517 bar with a double-acting fail-as-is rack and pinion actuator.The conclusion in this case is to avoid making any change in the design of double-acting actuator in connection to the closed loop system. 展开更多
关键词 Subsea Hydraulic system Valves and actuators closed loop hydraulic Hydraulic actuators Actuators design modification Emission reduction
下载PDF
Starting Control of Free Piston Stirling Linear Generator System Based on FOC
20
作者 Qiaoling Yang Kechun Zhang +2 位作者 Shenghui Guo Boliang Song Xiaoyu Zhang 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第2期195-200,共6页
Aiming at the problem of poor system dynamic performance caused by low parameter matching in the coordinated control of Stirling engine and linear generator in the starting stage control of free piston Stirling linear... Aiming at the problem of poor system dynamic performance caused by low parameter matching in the coordinated control of Stirling engine and linear generator in the starting stage control of free piston Stirling linear generator system,a joint control method of free piston Stirling permanent magnet synchronous linear generator system based on field orientation control is proposed,based on the theoretical derivation of the mathematical model of the system and the principle of controller parameters setting,the simulation experiments of the system starting stage under several Stirling engine working conditions are carried out under simulation.The experimental results show that the stability and rapidity of the system are improved,and the dynamic response speed of generator parameters under different working conditions is accelerated,what fully verifies the correctness and effectiveness of the method.It provides an effective way to improve the control performance of the system and stabilize the power generation operation. 展开更多
关键词 Parameter setting Field orientation control Double closed loop Permanent magnet synchronous linear generator
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部