期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
Estimation of Lightning-Generated NO_(x) in the Mainland of China Based on Cloud-to-Ground Lightning Location Data 被引量:1
1
作者 Qi LI Fengxia GUO +4 位作者 Xiaoyu JU Ze LIU Mingjun GAN Kun ZHANG Binbin CAI 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2023年第1期129-143,共15页
Lightning-generated nitrogen oxides(LNO_(x))have a major influence on the atmosphere and global climate change.Therefore,it is of great importance to obtain a more accurate estimation of LNO_(x).The aim of this study ... Lightning-generated nitrogen oxides(LNO_(x))have a major influence on the atmosphere and global climate change.Therefore,it is of great importance to obtain a more accurate estimation of LNO_(x).The aim of this study is to provide a reference for the accurate estimation of the total LNO_(x) in the mainland of China based on cloud-to-ground lightning(CG)location data from 2014 to 2018.The energy of each CG flash was based on the number of return strokes per CG flash,the peak current of each return stroke,and the assumed CG breakdown voltage.The energy of intracloud lightning(IC)was based on the estimated frequencies of IC and the assumed energy of each IC flash.Combining the energy of lightning and the number of nitric oxide(NO)molecules produced by unit energy(ρno),the total LNO_(x) production in the mainland of China was determined.The LNO_(x) in the mainland of China estimated in this study is in the range(0.157-0.321)×10^(9) kg per year[Tg(N)yr-1],which is on the high end of other scholars’works.Negative cloud-to-ground lightning(NCG)flashes produce the most moles of NO_(x),while positive cloud-to-ground lightning(PCG)flashes produce the least total moles of NO_(x).The breakdown voltage of PCG is greater than that of IC or NCG,while the latter has a greater output of LNO_(x). 展开更多
关键词 cloud-to-ground lightning location lightning peak current lightning breakdown voltage nitrogen oxide(NO_(x))
下载PDF
Characteristics of Cloud-to-ground Lightning during a Squall Line Process outside of the Subtropical High
2
作者 Zou Qin Xie Yiran +2 位作者 Xu Yingjie Liu Xuetao Zhang Tengfei 《Meteorological and Environmental Research》 CAS 2017年第5期25-29,36,共6页
Based on the monitoring data of cloud-to-ground( CG) lightning positioning network and Doppler weather radar as well as MICAPS1°× 1° objective analysis field,a squall line process outside of the subtrop... Based on the monitoring data of cloud-to-ground( CG) lightning positioning network and Doppler weather radar as well as MICAPS1°× 1° objective analysis field,a squall line process outside of the subtropical high in low-latitude plateau on May 7,2010 was analyzed. The results showed that wind direction shear between low and high levels and low-level convergence zones provided favorable circulation background for the strong thunderstorm process,while high energy and high humidity,strong thermal instability and ascending motion at low and middle levels offered beneficial environmental conditions for the formation of the thunderstorm. 9 620 return strokes of cloud-to-ground lightning were monitored by the lightning positioning network,and cloud-to-ground lightning was distributed like bands between 584 and 586 hP a. The occurrence of cloud-to-ground lightning was mainly related to echo top and echo intensity at-10 ℃ stratification height,and it mainly appeared in zones where echo top height was larger than 13 km and echo intensity at-10 ℃ stratification height was 35-40 dB Z. Wind convergence and maintaining of high radial velocity were favorable for the development of convective echoes and occurrence of cloud-to-ground lightning. 展开更多
关键词 Squall line: LIGHTNING location system DOPPLER WEATHER RADAR cloud-to-ground (CG) LIGHTNING
下载PDF
Study on the Scope of Small Amplitude of Cloud-to-ground Lightning in Lightning Weather Monitoring
3
作者 Luan Jian Wang Xing +3 位作者 Wang Peng Nie Yang Wang Yue Tan Wei 《Meteorological and Environmental Research》 CAS 2014年第3期7-10,15,共5页
Based on lightning location data in Chongqing region during 1999-2008,the frequency of lightning in various amplitude ranges and its annual variations were analyzed firstly.Afterwards,with the aid of matlab mathematic... Based on lightning location data in Chongqing region during 1999-2008,the frequency of lightning in various amplitude ranges and its annual variations were analyzed firstly.Afterwards,with the aid of matlab mathematical software,the distribution of the lightning location data was fitted using logarithmic normal distribution function.The results showed that after data of cloud-to-ground lightning with current amplitude from-5 to5 kA were deleted from lightning location data,the statistical characteristics of cloud-to-ground lightning could be reflected well.Meanwhile,lightning with current amplitude from-5 to 5 kA accounted for 1.05%(less than 2%),which accorded with the detection principle of lightning position indicator(there existed error detection).Therefore,cloud-to-ground lightning with current amplitude of-5-5 kA in lightning location data of Chongqing region was defined as small amplitude of cloud-to-ground lightning,which could provide scientific references for the processing of lightning location data in Chongqing region as well as analysis and quality control of lightning location data in other regions. 展开更多
关键词 Lightning location system Quality control Small amplitude cloud-to-ground lightning Logarithmic normal distribution China
下载PDF
Characteristics of Cloud-to-ground Lightning during a Local Rainstorm in Meizhou City
4
作者 Zhang Wenjie Guo Qing +1 位作者 Zeng Huijuan Wu Yongbin 《Meteorological and Environmental Research》 CAS 2018年第2期4-7,11,共5页
Based on cloud-to-ground lightning data of lightning location system,Doppler radar data,and precipitation data of regional automatic weather stations,the characteristics of cloud-to-ground lightning during a local rai... Based on cloud-to-ground lightning data of lightning location system,Doppler radar data,and precipitation data of regional automatic weather stations,the characteristics of cloud-to-ground lightning during a local rainstorm on June 4,2016 in Meizhou City were analyzed. The results showed that the spatial distribution of cloud-to-ground lightning from 14: 00 to 20: 00 on June 4,2016 in Meizhou City had obvious local characteristics,and the proportion of negative lightning was larger than that of positive lightning( only 16. 8%). The concentration period of positive lightning coincided with that of cloud-to-ground lightning. The peak of proportion of positive lightning lagged behind the peak of cloud-to-ground lightning,and appeared in the late period of thunderstorm disappearance. The dense area of cloud-to-ground lightning and the area with heavy rainfall coincided with the area with strong radar echoes. Doppler weather radar data had the feature of the headwind zone,strong combined reflectivity,vertical height of strong echoes,high echo top,and fast radial movement. The peak of cloud-to-ground lightning appeared one hour earlier than that of precipitation. There was no significant correlation between the frequency of cloud-to-ground lightning and precipitation. The peak of negative lightning corresponded to that of positive lightning,and cloud-to-ground lightning ended earlier than rainfall. After the peak of precipitation,convective system rapidly weakened and disappeared. Precipitation and the frequency of cloud-to-ground lightning fluctuated frequently during the whole process. The jumps and peaks of negative lightning were indicative of rainfall changes. 展开更多
关键词 cloud-to-ground lightning Local rainstorm Meizhou City
下载PDF
Studies on the Distribution Characteristics of the Cloud-to-Ground Lightning and Its Disasters Prevention in Xinjiang, China in 2017
5
作者 Wenjun Ye Yanhui Wang +3 位作者 Yong Qian Xiaolu Huang Yang Jiao Zhongquan Liu 《Journal of Geoscience and Environment Protection》 2019年第11期210-219,共10页
Xinjiang, China is affected by geographical terrain and other factors, and is prone to lightning disasters. In order to effectively carry out lightning protection and disaster reduction work and improve defense capabi... Xinjiang, China is affected by geographical terrain and other factors, and is prone to lightning disasters. In order to effectively carry out lightning protection and disaster reduction work and improve defense capabilities, based on the data of lightning location monitoring in Xinjiang in 2017 and the statistics reports of the lightning disasters from 2015 to 2017, the characteristics of the cloud-to-ground (CG) lightning activities and disasters in Xinjiang were statistically analyzed. The results show that the CG lightning in Xinjiang is mainly the negative one, accounting for 79.7% of the total lightning. In 2017, the distribution of positive, negative and total the CG lightning months mainly focuses on June to August, and the main occurrence period is from 14 to 23 hours. The intensity of total the CG lightning and negative the CG lightning mainly distributes from 20 to 40 kA, and the peak value appears in 30 kA. The CG lightning intensity is mainly distributed in 30 - 70 kA. The distribution of the CG lightning density in Xinjiang is larger in the north than in the south and larger in the west than in the east. Lightning disasters mainly occur from May to August, accounting for 93.2 percent of the total, with the largest number in June. From 2005 to 2017, 44.6% of lightning accidents occurred in farming and pastoral areas, followed by civil electronic equipment damage. In addition, electrical equipment, buildings and factory equipment are damaged by lightning strikes to varying degrees. 展开更多
关键词 cloud-to-ground LIGHTNING LIGHTNING Density LIGHTNING INTENSITY LIGHTNING DISASTERS XINJIANG of China
下载PDF
Observation and study on the whole process of cloud-to-ground lightning using narrowband radio interferometer 被引量:9
6
作者 ZHANG GuangShu ZHAO YuXiang +3 位作者 QIE XiuShu ZHANG Tong WANG YanHui CHEN ChengPin 《Science China Earth Sciences》 SCIE EI CAS 2008年第5期694-708,共15页
A narrowband radio interferometer has been developed and used to locate the entire sources of VHF radiations from a negative cloud-to-ground (CG) lightning discharge which contains 19 strokes. This system uses five an... A narrowband radio interferometer has been developed and used to locate the entire sources of VHF radiations from a negative cloud-to-ground (CG) lightning discharge which contains 19 strokes. This system uses five antennas to form an array consisting of short- and long-baselines along two or- thogonal directions. The system error which comes from frequency conversion is reduced by phase detection through direct high frequency amplifying. An interactive graphic analysis procedure is used to remove the fringe ambiguities which exist inherently in interferometry and to determine the direction of lightning radiation sources in two dimensions (azimuth and elevation) as a function of time at a time resolution of microsecond orders. With the developed system, the whole progression process in time and space of a lightning flash can be reconstructed. In this paper, combining the synchronous data of electric filed change and VHF radiation, the whole processes of an example negative CG flash have been studied in detail. It is found that the preliminary breakdown event of the CG flash started from negative charge region and exhibited firstly a downward pregression and then an upward propagation. There were very intense and continuous radiations during stepped leaders which became much stronger when the first return stroke began. In contrast, there were less and only discrete radiations during dart leaders. Stepped leader and dart leader may transform to each other depending on the state of the ionization of the path. The progression speed of initial stepped leaders was about 105 ms?1, while that was about 4.1×106 and 6.0×106 ms?1 for dart leaders and dart-stepped leaders, respectively. M events produced hook-shaped field changes accompanied by active burst of radiations at their begin- nings. Followed these active radiation processes, M events appeared to contact finally into conducting main discharge channels. The mean progression speed of M events was about 7×107 ms?1, greater than that of the dart leaders and dart-step leaders. K events and attempted leaders were essentially the same as dart leaders except that they could not reach the ground and initiate return strokes. 展开更多
关键词 LIGHTNING NARROWBAND interferometer DART LEADER K EVENTS M EVENTS the WHOLE process of cloud-to-ground LIGHTNING
原文传递
A Comparison of the Characteristics of Total and Cloud-to-Ground Lightning Activities in Hailstorms 被引量:19
7
作者 姚雯 张义军 +2 位作者 孟青 王飞 吕伟涛 《Acta meteorologica Sinica》 SCIE 2013年第2期282-293,共12页
The region of Beijing-Tianjin-Hebei is covered by two different lightning detection networks: SAFIR (Systeme d'Alerte Fondre par Interferometrie Radioelecctrique) for total lightning, including IntraCloud (IC) f... The region of Beijing-Tianjin-Hebei is covered by two different lightning detection networks: SAFIR (Systeme d'Alerte Fondre par Interferometrie Radioelecctrique) for total lightning, including IntraCloud (IC) flashes and Cloud-to-Ground (CG) flashes, and the ADTD (ADvanced TOA and Direction system; TOA denotes time of arrival) network of China for CG lightning. Fourteen isolated hail-bearing thunderstorms in this region were examined in this study, using the data of SAFIR and ADTD. The peak of lightning frequency, for both total lightning and CG lightning, was often observed in advance of the occurrence of hailstones on the ground, with a trend of a rapid increase of lightning frequency before the hail was reported. The average lead times of the two types of lightning jump before hail events were obtained (total lightning: 32.2 min; CG: 25.4 min) through the 2a lightning jump algorithm. Additionally, in hailstorms with a high ratio of positive CG flashes, the diameter of hail was larger and the duration of hail was longer; when negative CG flashes dominated, the diameter of hail was relatively small. The comparison of the characteristics of total lightning and CG flashes in hailstorms in this study is expected to serve as a supplementary tool for hail forecasting. 展开更多
关键词 total lightning (IC+CG) cloud-to-ground (CG)lightning hail-bearingthunderstorm lightning jump algorithm
原文传递
ANALYSIS OF CLOUD-TO-GROUND LIGHTNING CHARACTERISTICS IN MESOSCALE STORM IN BELIING AREA 被引量:16
8
作者 葛正谟 言穆弘 +2 位作者 GuoChangming 郭昌明 张广庶 《Acta meteorologica Sinica》 SCIE 1992年第4期491-500,共10页
The research indicates that there is a positive correlation between the negative CG flash rate and the area of radar echo with its reflectivity being equal to or greater than 30 dBz in the mesoscale convective system ... The research indicates that there is a positive correlation between the negative CG flash rate and the area of radar echo with its reflectivity being equal to or greater than 30 dBz in the mesoscale convective system in Beijing area.A max- imum of the positive CG flash rate exists at both the initial and the dissipating stages.The CG flashes are usually located near but not within the high reflectivity center.The negative flashes are associated with.the positions of the updraft re- gion,and with the regions of wind convergence and wind shear.Generally,the negative CG flashes are concentrative and the positive ones are dispersive. 展开更多
关键词 CG(cloud-to-ground)lightning mesoscale convective system radar echo evolution of lightning activity
原文传递
Observations on the leader-return stroke of cloud-to-ground lightning with the broadband interferometer 被引量:5
9
作者 董万胜 刘欣生 +1 位作者 张义军 张广庶 《Science China Earth Sciences》 SCIE EI CAS 2002年第3期259-269,共11页
Radio frequency observations of cloud-to-ground lightning (CG) were made in 1999 in Guangdong Province with the broadband lightning interferometer. In this paper, radiation source locations and electric field waveform... Radio frequency observations of cloud-to-ground lightning (CG) were made in 1999 in Guangdong Province with the broadband lightning interferometer. In this paper, radiation source locations and electric field waveforms are analyzed for different types of breakdown events, including the preliminary breakdown of in-cloud activities, the stepped leaders of initial strokes to ground and activities during and following return strokes. It is shown that the structure and development of lightning discharges and associated breakdown processes can be reconstructed by using this new type of lightning radiation source location system. The detectable radiation of lightning was primarily produced by the negative breakdown process. The channel was concentrated with few branches during the preliminary breakdown stage of CG lightning flashes. The radiation sources appeared generally at the tip of the channel. During the late period of the stepped leader, the radiation sources were dispersed with branches extended away from the main channel. The radiation sources were in a certain length segment of the channel and the altitude of the segment descended along with the propagation of the leader to the ground. During the preliminary breakdown and the stepped leader of initial strokes to the ground, a sequence of fast negative streamers were observed to start continually from or farther away the lightning-initiated region and propagate along the developed leader channel, which may supply negative charge that assisted the leader's development. The progression speed of fast negative streamers was about ten times faster than the average speed of lightning channel. 展开更多
关键词 BROADBAND interferometer cloud-to-ground lightning preliminary breakdown stepped leader.
原文传递
Optical Observations on Propagation Characteristics of Leaders in Cloud-to-Ground Lightning Flashes 被引量:4
10
作者 吕伟涛 张义军 +4 位作者 李俊 郑栋 董万胜 陈绍东 王飞 《Acta meteorologica Sinica》 SCIE 2008年第1期66-77,共12页
Using 2 high-speed cameras, we have recorded 14 negative cloud-to-ground (CG) lightning flashes, half of which are natural and the others are artificially triggered. The two-dimensional (2D) propagation speed of d... Using 2 high-speed cameras, we have recorded 14 negative cloud-to-ground (CG) lightning flashes, half of which are natural and the others are artificially triggered. The two-dimensional (2D) propagation speed of different type leaders and the luminosity of lightning channel are analyzed in detail. Bidirectional leader processes are observed during the initial processes of two altitude triggered negative lightning (ATNL) flashes. The analysis shows: the propagation speed of the upward positive leader (UPL) before the initiation of the downward negative leader (DNL) is at the order of 10^4-10^5 m s-1; the UPL can be intensified by the initiation and development of the DNL in the way that the luminosity is enhanced and the speed is sped up; after initiation, the DNL in one ATNL flash propagates downward three times intermittently with interval of about 1 ms, while that in the other ATNL flash propagates downward continuously with a speed at the order of 10^5 m s^-1. In the five classical triggered negative lightning (CTNL) flashes, the propagation speeds of the UPLs vary between 0.35×10^5 and 7.71×10^5 m s-1, and the variations of their luminosities and speeds are quite complex during the development processes. Among the four observed natural negative lightning flashes occurred on the land, three have only one return stoke (RS) each and all of their DNLs have many branches with an average speed at the order of 10^5 m s-l; while the another one has 13 RSs. In the CG flash with 13 RSs, the DNL before the first RS has no obvious branch below 1.4 km above the ground, and its speed ranges from 2.2×10^5 to 2.3×10^6 m s-1 between the heights of 0.7 and 1.4 km and exceeds 3.9×10^6 m s-1 below 0.7 km; preceding the 4th RS, an attempted leader is observed with a speed ranging from 1.1× 10^5 to 1.1×10^6 m s-1 between 0.8 and 1.5 km. As for the three observed natural negative lightning flashes occurred on the sea, each has only one RS, and each DNL preceding the RS has a few branches, two of which have an average propagation speed at the order of 10^5 m s-1, and the other of 10^6 m s-1, respectively. All the DNLs contained in the observed natural negative lightning flashes, except the attempted leader, propagate with gradually increasing luminosity and increasing speed in whole. 展开更多
关键词 cloud-to-ground lightning propagation speed of leader luminosity of lightning channel highspeed photography
原文传递
Positive Charge Region in Lower Part of Thunderstorm and Preliminary Breakdown Process of Negative Cloud-to-Ground Lightning 被引量:3
11
作者 张义军 孟青 +3 位作者 吕伟涛 马明 郑栋 Pau R.Krehbiel 《Acta meteorologica Sinica》 SCIE 2009年第1期95-104,共10页
A new lightning locating technology, called Lightning Mapping Array (LMA), has been developed. The system takes advantage of GPS technology to measure the times of arrival (TOA) of lightning impulsive very high fr... A new lightning locating technology, called Lightning Mapping Array (LMA), has been developed. The system takes advantage of GPS technology to measure the times of arrival (TOA) of lightning impulsive very high frequency (VHF) radiation events at each remote location. The spatiotemporal development processes of lightning are described in three-dimension by measurement of the system with high time resolution (50 ns) and space precision (50-100 m). The charge structures in thunderstorm and their relationship with lightning discharge processes are revealed. The temporal and spatial characteristics of preliminary breakdown process involved in negative cloud-to-ground (CG) lightning discharges are analyzed based on the data of lightning VHF radiation events. The effect of positive charge region in lower part of thunderstorm on the occurrence of negative CG lightning discharge is discussed. The results indicate that the preliminary breakdown process with longer duration in negative CG lightning discharges is an intracloud discharge process. It occurs between negative and positive charge regions located in middle and lower parts of thunderstorm respectively. It initiates from the negative charge region and propagates downward. After propagating into the positive charge region, the lightning channel develops horizontally. The characteristics of the preliminary breakdown process are consistent with that of intracloud lightning discharges. The stepped leaders are initiated by the K type breakdown which occurs in the last stage of the preliminary breakdown process and develops downward through the positive charge region. The existence of positive charge region in lower part of thunderstorm results in the occurrence of preliminary breakdown process with longer duration before the return stroke of negative CG lightning discharges. 展开更多
关键词 cloud-to-ground lightning positive charge preliminary breakdown process
原文传递
A Case Study of Cloud-to-Ground Lightning Activities in Hailstorms under Cold Eddy Synoptic Situation
12
作者 冯桂力 郄秀书 +1 位作者 袁铁 周筠珺 《Acta meteorologica Sinica》 SCIE 2006年第4期489-499,共11页
There were three hailstorms in Shandong Province, caused by a same northeast cold eddy situation on 1 June 2002. Cloud-to-ground (CG) flashes occurring in the weather event were observed by Shandong Lightning Detect... There were three hailstorms in Shandong Province, caused by a same northeast cold eddy situation on 1 June 2002. Cloud-to-ground (CG) flashes occurring in the weather event were observed by Shandong Lightning Detection Network (SLDN), which consists of 10 sensors covering all over Shandong Province. The temporal and spatial distributions of CG lightning are investigated for the three hailstorms by using the data from SLDN, Doppler radar and satellite. The results show that different thunderstorms present different lightning features even if under the same synoptic situation. The percentage of positive CG lightning is very high during the period of hail falling. CG flashes mainly occurred in the region with a cloud top brightness temperature lower than -50℃. Negative CG flashes usually clustered in the lower temperature region and tended to occur in the region with maximum temperature gradient, while the positive ones usually spread discretely. Negative CG flashes usually occurred in intense echo regions with reflectivity greater than 50 dBz, while the positive CG flashes often occurred in weak and stable echo regions (10-30 dBz) or cloud anvils, although they can be observed in strong convective regions sometimes. Almost all haft falling took place in the stage with active positive flashes, and the peak positive flash rate is a little prior to the hail events. The thunderstorm could lead to disastrous weather when positive CG lightning activities occur in cluster. Severe thunderstorms sometimes present a low flash rate at its vigorous stage, which is probably caused by the "mechanism of chargeregion lift" through investigating the reflectivity evolution. Combined with the total lightning (intracloud and CG) data obtained by LIS onboard TRMM, the phenomenon of high ratio of intracloud flash to CG flash in severe hailstorm has been discussed. The competition of the same charge sources between different lightning types can also be helpful for explaining the cause of low CG lightning activities in severe storms. 展开更多
关键词 HAILSTORM cloud-to-ground (CG) lightning echo intensity brightness temperature distribution characteristics
原文传递
Temporal and Spatial Distribution of Lightning Activity in Ulanqab City
13
作者 Qiang MA 《Meteorological and Environmental Research》 CAS 2023年第1期60-62,共3页
From January 2020 to December 2021,Ulanqab Meteorological Bureau of Inner Mongolia used VLF/LF lightning locator to carry out three-dimensional lightning monitoring in Ulanqab City,and compared with ADTD lightning loc... From January 2020 to December 2021,Ulanqab Meteorological Bureau of Inner Mongolia used VLF/LF lightning locator to carry out three-dimensional lightning monitoring in Ulanqab City,and compared with ADTD lightning location data in the same period.The results show that both VLF/LF lightning locator and ADTD lightning locator had excellent monitoring ability for lightning during flood season in Ulanqab.VLF/LF lightning locator was slightly superior to ADTD lightning locator in observation accuracy,the observation ability of low-current cloud-to-ground lightning,intracloud lightning observation and so on.There were obvious temporal and spatial characteristics of cloud-to-ground lightning during flood season in Ulanqab,and there was a certain correlation between the areas where lightning appeared frequently and surface water.Intracloud lightning was mainly concentrated at a height of 1-7 km.Negative cloud-to-ground lightning accounted for about 75%of total cloud-to-ground lightning,and negative intracloud lightning accounted for 39%of total intracloud lightning. 展开更多
关键词 Lightning location cloud-to-ground lightning Intracloud lightning Temporal and spatial distribution
下载PDF
Locating Parent Lightning Strokes of Sprites Observed over a Mesoscale Convective System in Shandong Province,China 被引量:6
14
作者 Anjing HUANG Gaopeng LU +5 位作者 Hongbo ZHANG Feifan LIU Yanfeng FAN Baoyou ZHU Jing YANG Zhichao WANG 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2018年第11期1396-1414,共19页
In this paper, we report the location results for the parent lightning strokes of more than 30 red sprites observed over an asymmetric mesoscale convective system(MCS) on 30 July 2015 in Shandong Province, China, with... In this paper, we report the location results for the parent lightning strokes of more than 30 red sprites observed over an asymmetric mesoscale convective system(MCS) on 30 July 2015 in Shandong Province, China, with a long-baseline lightning location network of very-low-frequency/low-frequency magnetic field sensors. The results show that almost all of these cloud-to-ground(CG) strokes are produced during the mature stage of the MCS, and are predominantly located in the trailing stratiform region, which is similar to analyses of sprite-productive MCSs in North America and Europe. Comparison between the location results for the sprite-producing CG strokes and those provided by the World Wide Lightning Location Network(WWLLN) indicates that the location accuracy of WWLLN for intense CG strokes in Shandong Province is typically within 10 km, which is consistent with the result based on analysis of 2838 sprite-producing CG strokes in the continental United States. Also, we analyze two cases where some minor lightning discharges in the parent flash of sprites can also be located, providing an approach to confine the thundercloud region tapped by the sprite-producing CG strokes. 展开更多
关键词 red SPRITES positive cloud-to-ground strokes(+CGs) MESOSCALE CONVECTIVE system(MCS)
下载PDF
A PRELIMINARY STUDY ON THUNDERSTORM FORECAST WITH LS-SVM METHOD 被引量:3
15
作者 王振会 张祎 朱佳 《Journal of Tropical Meteorology》 SCIE 2013年第1期104-108,共5页
The LS-SVM(Least squares support vector machine) method is presented to set up a model to forecast the occurrence of thunderstorms in the Nanjing area by combining NCEP FNL Operational Global Analysis data on 1.0°... The LS-SVM(Least squares support vector machine) method is presented to set up a model to forecast the occurrence of thunderstorms in the Nanjing area by combining NCEP FNL Operational Global Analysis data on 1.0°×1.0° grids and cloud-to-ground lightning data observed with a lightning location system in Jiangsu province during 2007-2008.A dataset with 642 samples,including 195 thunderstorm samples and 447 non-thunderstorm samples,are randomly divided into two groups,one(having 386 samples) for modeling and the rest for independent verification.The predictors are atmospheric instability parameters which can be obtained from the NCEP data and the predictand is the occurrence of thunderstorms observed by the lightning location system.Preliminary applications to the independent samples for a 6-hour forecast of thunderstorm events show that the prediction correction rate of this model is 78.26%,false alarm rate is 21.74%,and forecasting technical score is 0.61,all better than those from either linear regression or artificial neural network. 展开更多
关键词 THUNDERSTORM FORECAST LS-SVM NANJING area cloud-to-ground LIGHTNING NCEP
下载PDF
Characteristics of thunderstorms and lightning flashes in the Chinese inland plateau 被引量:1
16
作者 TingLong Zhang Tong Zhang Yang Zhao XiangZhen Kong YanHui Wang 《Research in Cold and Arid Regions》 2010年第3期271-277,共7页
The electrical characteristics of thunderstorms in three different altitude regions of the Chinese inland plateau have been analyzed in this paper. The results show, according to the polarity of the surface electric ... The electrical characteristics of thunderstorms in three different altitude regions of the Chinese inland plateau have been analyzed in this paper. The results show, according to the polarity of the surface electric (E) field, that the thunderstorms can be divided into two categories in the study regions: one showing the normal tripole electrical charge structure (normal-type), and the other showing the special tripole charge structure with a larger-than-usual lower positive charge center (LPCC) at the base of thunderstorm (special-type), where the induced surface E field is controlled by the LPCC when a thunderstorm is overhead. We find that the two types of thunderstorms have different occurrences in different regions, and the percentage of special-type thunderstorms increases with the altitude. On the whole, the flash rate of thunderstorms is quite low, and the mean value is about 1-3 fl/min, while the flash rate of special-type is slightly greater than that of the normal-type thunderstorm. The statistical results of cloud-to-ground flash (CG) numbers indicate that the ratio of +CG flash increases with the altitude, with the value about 14.7 percent through 25.4 percent. 展开更多
关键词 thunderstorm flash rate cloud-to-ground flash
下载PDF
Numerical simulation of 23 June 2016 Yancheng City EF4 tornadic supercell and analysis of lightning activity 被引量:3
17
作者 GUO FengXia LI Yang +4 位作者 HUANG ZhaoChu WANG ManFei ZENG FanHui LIAN ChunHao MU YiJun 《Science China Earth Sciences》 SCIE EI CAS CSCD 2017年第12期2204-2213,共10页
Based on the Weather Research Forecasting(WRF) model that features charging and discharging parameterization,relationships between tornado, hail and lightning were investigated for a tornado-producing(EF4 intensity) s... Based on the Weather Research Forecasting(WRF) model that features charging and discharging parameterization,relationships between tornado, hail and lightning were investigated for a tornado-producing(EF4 intensity) supercell thunderstorm over Yancheng City in Jiangsu Province, China, on 23 June 2016. Based on a sounding at 0800, there was a low lifting condensation level, substantial convective available potential energy(CAPE), and strong vertical wind shear near Yancheng City, which promote supercell development. At 1400, observations revealed that hail production and a dramatic increase of positive cloud-to-ground flash rates occurred simultaneously, maximizing five minutes later. The tornado occurred 30 min after the hail production. The time of minimum positive cloud-to-ground flash rates was 15 min later. The simulation indicated that the tornadic supercell moved eastward and that positive cloud-to-ground flash rates increased dramatically at 1400, the same as observed, but their maximum was 5 min later than observed. The simulated updraft volume peaked at 1425 and the simulated downdraft volume maximized5 min later, when the mesocyclone formed. Simulated reflectivities showed no hook echo and horizontal winds for different height at mid-low levels had a different cyclonic shear at 1430, favorable to mesocyclone formation. Based on the simulated results,the region of positively charged graupel ascended resulting from the region of high liquid water content was lifted by the strong updraft, forming a mid-level strong positive charge region. A lower negative charge region formed by the inductive charging mechanism of collisions between graupel and droplets at the bottom of the cloud, conducive to positive cloud-to-ground flashes. 展开更多
关键词 TORNADO SUPERCELL WRF HAIL Positive cloud-to-ground flashes
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部