期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
邯郸市案例医院Co-60放疗机房退役场址环境辐射影响分析 被引量:1
1
作者 王春芹 赵卫红 薛娇娇 《环境与可持续发展》 2016年第6期160-161,共2页
邯郸市辖区内案例医院Co-60放疗机退役,放射源送交有资质单位收贮。本文根据相关法律法规及标准,对此医院放疗机退役后场址环境辐射影响进行分析、辐射环境进行监测,经过现状监测和环境影响分析,该医院退役场址达到无限制开放标准。
关键词 co-60放疗机房退役 环境辐射影响 案例医院
下载PDF
Preparation and characterization of iron-ore-imbedded silicone rubber materials for radiation protection 被引量:2
2
作者 Bulent Buyuk 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第9期230-235,共6页
Iron-ore-imbedded silicone rubber materials were produced for radiation shielding. Samples were tested against a Co-60 gamma source, which is widely used in nuclear technology and medicine. Decreasing the particle siz... Iron-ore-imbedded silicone rubber materials were produced for radiation shielding. Samples were tested against a Co-60 gamma source, which is widely used in nuclear technology and medicine. Decreasing the particle size of iron ore resulted in better gamma radiation protection owing to more homogenous distribution. In addition, the materials had flexible properties up to the addition of 60 wt% iron ore content. Further, 0.5 mm Pb E gamma protection was provided by using 2.06-mm-thick SDT-60 as the Co-60 source. Iron ore–silicone rubber composites are candidate materials for lead-free flexible radiation protection systems owing to their relatively inexpensive and easy production. 展开更多
关键词 Iron ORE SILICONE rubber radiation SHIELDING co-60 LEAD-FREE flexible materials Linear attenuation COEFFICIENTS
下载PDF
Effect of irradiation on temperature performance of dispersioncompensation no-core cascade optical-fiber sensor coated with polydimethylsiloxane film
3
作者 Fang Wang Qiu-Feng Wu +4 位作者 Yu-Rong Jiang Chan Jin Xiao-Hui Wang Ben-Shang Zhang Chun-Wang Ma 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第9期10-20,共11页
A temperature measurement device can produce data deviations and can even be damaged in a high-dose radiation environment.To reduce the radiation damage to such a device and improve the temperature measurement accurac... A temperature measurement device can produce data deviations and can even be damaged in a high-dose radiation environment.To reduce the radiation damage to such a device and improve the temperature measurement accuracy in a radiation environment,a temperature sensor based on optical-fiber sensing technology is proposed.This sensor has a cascade structure composed of a single-mode fiber(SMF),a dispersion-compensation fiber(DCF),a nocore fiber(NCF),and another SMF(SDNS).The DCF and NCF are coated with a polydimethylsiloxane(PDMS)film,which is a heat-sensitive material with high thermal optical and thermal expansion coefficients.In experiments,PDMS was found to produce an irradiation crosslinking effect after irradiation,which improved the temperature sensitivity of the SDNS sensor.The experimental results showed that within a range of 30–100℃,the maximum temperature sensitivity after irradiation was 62.86 pm/℃,and the maximum transmission sensitivity after irradiation was 3.353×10^(-2)dB/℃,which were 1.22 times and 2.267 times the values before irradiation,respectively.In addition,repeated temperature experiments verified that the SDNS sensor coated with the PDMS film had excellent temperature repeatability.Furthermore,it was found that with an increase in the irradiation intensity,the irradiation crosslinking degree of PDMS increased,and the temperature sensitivity of the sensor was improved.The proposed sensor could potentially be applied to temperature measurement in a nuclear-radiation environment. 展开更多
关键词 ^(60)co-γirradiation Optical-fiber sensor Temperature performance PDMS radiation crosslinking
下载PDF
Preliminary Research on Radiation Breeding of Pteroceltis tatarinowii Maxim.
4
作者 Chengxiu LI Tiantian CHENG +2 位作者 Zhongkui SUN Yu YAN Lin ZHANG 《Agricultural Biotechnology》 CAS 2021年第6期14-15,18,共3页
In order to explore the effect of radiation breeding on new germplasm innovation of Pteroceltis tatarinowii,the dry seeds of P.tatarinowii from Lingyan Temple were used as test materials in this study,which were irrad... In order to explore the effect of radiation breeding on new germplasm innovation of Pteroceltis tatarinowii,the dry seeds of P.tatarinowii from Lingyan Temple were used as test materials in this study,which were irradiated by ^(60)Co-γ rays with different radiation doses.The results showed that the emergence rate decreased with the increase of radiation dose,the emergence rate of low dose below 200 Gy decreased slowly,and the emergence rate of high dose above 200 Gy decreased sharply;when the radiation dose ranged from 100 to 200 Gy,the mutagenic effect of P.tatarinowii seeds was the best;and radiation obviously affected the leaf color and leaf shape of seedlings.This study provides original materials for the cultivation of new P.tatarinowii varieties and the study of color-changing mechanism. 展开更多
关键词 Pteroceltis tatarinowii Maxim. ^(60)co-γradiation Seedling emergence
下载PDF
SWELLING BEHAVIOR OF ACRYLAMIDE HYDROGEL IN DIFFERENT SOLVENTS AND pHs 被引量:7
5
作者 M.F.Mina M.M.Alam 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2005年第3期269-274,共6页
Swelling property of acrylamide hydrogels,prepared from aqueous solutions of acrylamide monomer havingconcentrations in the range of 10-60 wt% by ray irradiation method using a Co-60 gamma radiation source at dosesran... Swelling property of acrylamide hydrogels,prepared from aqueous solutions of acrylamide monomer havingconcentrations in the range of 10-60 wt% by ray irradiation method using a Co-60 gamma radiation source at dosesranging 1-30.0 kGy,has been investigated under various swelling media.These swelling media were basically solvents(solutions),produced by dissolving methanol,ethanol,glucose,sucrose,sodium chloride and sodium persulfate individuallywith distilled water,and solutions prepared with pHs=3,7 and 10.The investigation was performed in order to observe theeffect of these solvents and pHs as well as the influence of monomer concentrations,radiation doses and times on swellingbehavior of hydrogels.Swelling values were found higher for hydrogels prepared with lower monomer concentrations(ca.20 wt%)and radiation doses(ca.5 kGy)and showed a leveling off tendency within 24 h.The glucose solvent and the buffersolution of pH=10 revealed significant increase of swelling of hydrogels as compared to other solutions.Results areexplained based on crosslinking density in hydrogel,polymer-solvent/polymer-polymer interactions in solutions,permeability of molecules in solutions and ionization capacity of hydrogel in pH. 展开更多
关键词 ACRYLAMIDE HYDROGEL co-60 gamma radiation source Swelling.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部