期刊文献+
共找到333篇文章
< 1 2 17 >
每页显示 20 50 100
Preliminary Study on Some Properties of Co-Cr Dental Alloy Formed by Selective Laser Melting Technique 被引量:5
1
作者 张飚 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第4期665-668,共4页
The surface condition, some properties and ion releasing behavior of cobalt-chromium (Co-Cr) dental alloy formed by selective laser melting (SLM) technique were investigated. Before porcelain fused firing, the sur... The surface condition, some properties and ion releasing behavior of cobalt-chromium (Co-Cr) dental alloy formed by selective laser melting (SLM) technique were investigated. Before porcelain fused firing, the surface condition of the Co-Cr alloy was observed using a scanning electron microscope (SEM), and then the density and hardness were examined. After porcelain fused firing, the interface of porcelain and alloy was observed, and then the metal-ion release of the samples was tested. SLM technique provides Co-Cr alloy higher hardness than casting method. After degassing-oxidation procedure and porcelain fused firing, the interface of the alloy and porcelain showed excellent combination. Co ion was more than Cr ion released from SLM Co-Cr alloy, the amounts of Co and Cr ions were safe according to ISO security criterion. Considering the properties before and after porcelain fused sintering process, SLM technique is suitable for dental Co-Cr alloy restoration. 展开更多
关键词 SLM dental co-cr alloy
下载PDF
Electrochemical behavior of Co-Cr and Ni-Cr dental cast alloys 被引量:8
2
作者 Viswanathan S. SAJI Han-Cheol CHOE 《中国有色金属学会会刊:英文版》 EI CSCD 2009年第4期785-790,共6页
The cast structures influencing the electrochemical corrosion behavior of Co-Cr and Ni-Cr dental alloys were studied using potentiodynamic polarization and AC impedance in 0.9% (mass fraction) NaCl solution at (37... The cast structures influencing the electrochemical corrosion behavior of Co-Cr and Ni-Cr dental alloys were studied using potentiodynamic polarization and AC impedance in 0.9% (mass fraction) NaCl solution at (37±1) ℃. The phase and microstructure of the alloys that were fabricated using two different casting methods viz. centrifugal casting and high frequency induction casting, were examined using X-ray diffraction analysis, scanning electron microscopy and energy dispersive spectroscopy. The roles of alloying elements and the passive film homogeneity on the corrosion resistance of Co-Cr-Mo and Ni-Cr-Mo dental cast alloys were reviewed. The results of electrochemical study show that the dependence of corrosion resistance on the microstructure associated with the casting methods is marginal. The Co-Cr alloy exhibits more desirable corrosion resistance properties than the Ni-Cr alloy. There is severe preferential dissolution of Ni-rich, Cr and Mo depleted zones in the Ni-Cr alloy. 展开更多
关键词 镍铬合金 合金铸造 电化学行为 牙科 电化学腐蚀行为 X射线衍射分析 NaCl溶液
下载PDF
Urinary levels of nickel and chromium associated with dental restoration by nickel-chromium based alloys 被引量:4
3
作者 Bo Chen Gang Xia +5 位作者 Xin-Ming Cao Jue Wang Bi-Yao Xu Pu Huang Yue Chen Qing-Wu Jiang 《International Journal of Oral Science》 SCIE CAS CSCD 2013年第1期44-48,共5页
This paper aims to investigate if the dental restoration of nickel-chromium based alloy(Ni-Cr) leads to the enhanced excretions of Ni and Cr in urine.Seven hundred and ninety-five patients in a dental hospital had sin... This paper aims to investigate if the dental restoration of nickel-chromium based alloy(Ni-Cr) leads to the enhanced excretions of Ni and Cr in urine.Seven hundred and ninety-five patients in a dental hospital had single or multiple Ni-Cr alloy restoration recently and 198 controls were recruited to collect information on dental restoration by questionnaire and clinical examination.Urinary concentrations of Ni and Cr from each subject were measure by graphite furnace atomic absorption spectrometry.Compared to the control group,the urinary level of Ni was significantly higher in the patient group of < 1 month of the restoration duration,among which higher Ni excretions were found in those with either a higher number of teeth replaced by dental alloys or a higher index of metal crown not covered with the porcelain.Urinary levels of Cr were significantly higher in the three patient groups of <1,1 to <3 and 3 to <6 months,especially in those with a higher metal crown exposure index.Linear curve estimations showed better relationships between urinary Ni and Cr in patients within 6-month groups.Our data suggested significant increased excretions of urinary Ni and Cr after dental restoration.Potential short- and long-term effects of Ni-Cr alloy restoration need to be investigated. 展开更多
关键词 dental restoration nickel-chromium based alloys population investigation urinary chromium urinary nickel
下载PDF
Metal-ceramic Bond Mechanism of the Co-Cr Alloy Denture with Original Rough Surface Produced by Selective Laser Melting 被引量:7
4
作者 ZHANG Sheng LI Yong +3 位作者 HAO Liang XU Tian WEI Qingsong SHI Yusheng 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第1期69-78,共10页
The porcelain fracture caused by low metal-ceramic bond strength is a critical issue in porcelain fused to metal(PFM) restorations. Surface roughening methods, such as sand blasting, acid etching and alkaline degrea... The porcelain fracture caused by low metal-ceramic bond strength is a critical issue in porcelain fused to metal(PFM) restorations. Surface roughening methods, such as sand blasting, acid etching and alkaline degreasing for the metal matrix are used to increase bond strength. However, the metal matrix of PFM processed by selective laser melting(SLM) has natural rough surface. To explore the effect of the original roughness on metal-ceramic bond strength, two groups of specimen are fabricated by SLM. One group of specimen surface is polished smooth while another group remains the original rough surface. The dental porcelain is fused to the specimens' surfaces according to the ISO 9693:1999 standard. To gain the bond strength, a three-point bending test is carried out and X ray energy spectrum analysis(EDS), scanning electron microscope(SEM) are used to show fracture mode. The results show that the mean bond strength is 116.5 16 MPa of the group with rough surface(Ra= 17.2), and the fracture mode is cohesive. However, when the surface is smooth (Ra =3.8), the mean bond strength is 74.5 MPa _+ 5 MPa and the fracture mode is mixed. The original surface with prominent structures formed by the partly melted powder particles, not only increases surface roughness but also significantly improves the bond strength by forming strong mechanical lock effect. Statistical analysis (Student's t-test) demonstrates a significant difference (p〈0.05) of the mean value of bond strength between the two groups. The experiments indicate the natural rough surface can enhance the metal-ceramic bond strength to over four times the minimum value (25 MPa) of the ISO 9693:1999 standard. It is found that the natural rough surface of SLM-made PFM can eliminate the porcelain collapse defect produced by traditional casting method in PFM restorations. 展开更多
关键词 selective laser melting(SLM) co-cr alloy metal-ceramic bond strength
下载PDF
Microstructure and dry wear properties of Ti-Nb alloys for dental prostheses 被引量:2
5
作者 徐丽娟 肖树龙 +2 位作者 田竟 陈玉勇 黄玉东 《中国有色金属学会会刊:英文版》 CSCD 2009年第S3期639-644,共6页
The microstructure and properties of a series of binary Ti-Nb alloys for dental prostheses with niobium contents ranging from 5% to 20% were investigated. The experimental results indicate that the crystal structure a... The microstructure and properties of a series of binary Ti-Nb alloys for dental prostheses with niobium contents ranging from 5% to 20% were investigated. The experimental results indicate that the crystal structure and morphology of Ti-Nb alloys are sensitive to their niobium contents. When Nb content is 5%, the acicular α crystal grain is observed. When Nb content is 10%, the coarse equiaxed crystal grain and the fine, acicular α crystal grain are observed. When Nb content is 15%, only the α equiaxed crystal grain is observed. When the alloy contains 20%Nb, the equiaxed and dendritic α crystal grain are observed. For Ti-Nb alloys, the increase of Nb content modifies the microstructure of Ti-Nb alloys significantly and decreases their compression elastic modulus, in which Ti-20Nb alloy shows the largest compression strength and Ti-5Nb alloy shows the best plasticity. The dry wear resistance of Ti-Nb alloys against Gr15 ball was investigated on CJS111A ball-disk wear instrument. For Ti-Nb alloys, Ti-10Nb alloy shows a smallest steady friction coefficient, Ti-5Nb alloy shows the smallest wear depth and best wear resistance, and Ti-15Nb alloy shows the largest wear depth and worst wear resistance. The phenomenon of furrow cut happens and furrows form during wear tests. 展开更多
关键词 TI-NB alloy MICROSTRUCTURE DRY WEAR resistance dental PROSTHESES material
下载PDF
Solidification of Be-free Ni-based dental alloy 被引量:1
6
作者 Franc ZUPANIC Carlos A.NUNES +3 位作者 Gilberto C.COELHO Paula L.CURY Gorazd LOJEN Tonica BONCINA 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2018年第11期2227-2236,共10页
A novel, Nb- and Si-rich and Be-free Ni-based alloy was cast by two methods of investment casting and continuouscasting to study the microstructure evolution during solidification and its mechanical properties. The so... A novel, Nb- and Si-rich and Be-free Ni-based alloy was cast by two methods of investment casting and continuouscasting to study the microstructure evolution during solidification and its mechanical properties. The solidification of the alloy startedwith the primary crystallization of FCC-γ, followed by a binary eutectic reaction, with the formation of a heterogeneous constituent:FCC-γ+G-phase, which replaced the low-melting eutectic (FCC-γ+NiBe) in the Be-bearing alloys. AlNi6Si3 and γ′ formed during theterminal stages of solidification by investment casting, while the formation of AlNi6Si3 was suppressed by continuous casting. TheScheil solidification model agreed very well with the experimental results. 展开更多
关键词 SOLIDIFICATION nickel alloy continuous casting investment casting MICROSTRUCTURE dental alloy
下载PDF
Corrosion behaviours of the dental magnetic keeper complexes made by different alloys and methods
7
作者 Min-Ke Wu Ning Song +5 位作者 Fei Liu Liang Kou Xiao-Wen Lu Min Wang Hang Wang Jie-Fei Shen 《International Journal of Oral Science》 SCIE CAS CSCD 2016年第3期155-163,共9页
The keeper and cast dowel-coping, as a primary component for a magnetic attachment, is easily subjected to corrosion in a wet environment, such as the oral cavity, which contains electrolyte-rich saliva, complex micro... The keeper and cast dowel-coping, as a primary component for a magnetic attachment, is easily subjected to corrosion in a wet environment, such as the oral cavity, which contains electrolyte-rich saliva, complex microflora and chewing behaviour and so on. The objective of this in vitro study was to examine the corrosion resistance of a dowel and coping-keeper complex fabricated by finish keeper and three alloys (cobalt-chromium, CoCr; silver-palladium-gold, PdAu; gold-platinum, AuPt) using a laser- welding process and a casting technique. The surface morphology characteristics and microstructures of the samples were examined by means of metallographic microscope and scanning electron microscope (SEM). Energy-dispersive spectroscopy (EDS) with SEM provided elements analysis information for the test samples after 10% oxalic acid solution etching test. Tafel polarization curve recordings demonstrated parameter values indicating corrosion of the samples when subjected to electrochemical testing. This study has suggested that massive oxides are attached to the surface of the CoCr-keeper complex but not to the AuPt-keeper complex. Only the keeper area of cast CoCr-keeper complex displayed obvious intergranular corrosion and changes in the Fe and Co elements, Both cast and laser-welded AuPt-keeper complexes had the highest free corrosion potential, followed by the PdAu-keeper complex. We concluded that although the corrosion resistance of the CoCr-keeper complex was worst, the keeper surface passive film was actually preserved to its maximum extent. The laser-welded CoCr- and PdAu-keeper complexes possessed superior corrosion resistance as compared with their cast specimens, but no significant difference was found between the cast and laser-welded AuPt-keeper complexes. The Fe-poor and Cr-rich band, appearing on the edge of the keeper when casting, has been proven to be a corrosion-prone area. 展开更多
关键词 cobalt-chromium alloy corrosion behaviour dental magnets gold-platinum alloy magnetic attachment silver-palladium-gold alloy
下载PDF
Synthesis of Co-Cr-Mo Fluorapatite Nano-Composite Coatings by Pulsed Laser Deposition for Dental Applications
8
作者 Osama Khfagi Ntevheleni Thovhogi +2 位作者 Dhiro Gihwala Malik Maaza Johan André Mars 《Materials Sciences and Applications》 2017年第2期135-152,共18页
Aim: The study was to fabricate FA nanopowder/Co-Cr-Mo dental alloy nanocomposite using pulsed laser deposition (PLD), and to evaluate bioactivity properties on simulated body fluid. Methods: In this work, the FA nano... Aim: The study was to fabricate FA nanopowder/Co-Cr-Mo dental alloy nanocomposite using pulsed laser deposition (PLD), and to evaluate bioactivity properties on simulated body fluid. Methods: In this work, the FA nanopowder was prepared by mixing calcium hydroxide (Ca(OH)2), phosphorouspent oxide (P2O5) and calcium fluoride (CaF2) in a planetary high energy ball mill using zirconium vial. Fluorapatite (FA) nanopowder was processed in the form of pellet for pulsed laser deposition process. The Co-Cr-Mo alloy was coated with FA nanopowder which was approximately 35 - 65 nm at various laser energy, pressure and time. The X-ray diffraction (XRD) was used to analyze phase, crystallinity and size distribution of Co-Cr-Mo/FA nanocomposite. The surface analysis was by scanning electron microscopy (SEM), Atomic Force microscopy (AFM) and Energy dispersive spectroscopy (EDS). Results: From the results obtained, It was shown that FA nanopowder deposited on Co-Cr-Mo alloy was stable during 14 days of incubation on simulated body fluid. It was also observed that the FA nanopowder coated on the surface of the alloy was still intact after the deposition process, which indicated the bioactivity and biocompatibility of the material. Conclusions: The fabrication of FA nanocomposite based dental alloys (Co-Cr-Mo) using PLD was done successfully. This was confirmed by various characterization techniques, which included XRD, AFM, SEM and EDS. 展开更多
关键词 BIOCOMPATIBILITY Cobalt-Chromium-Molybdenum alloyS dental alloyS FLUORAPATITE Pulsed Laser Deposition (PLD) Simulated Body Fluid (SBF)
下载PDF
Electron Probe Microanalysis of Exogenous Pigmentation of Oral Mucosa Originating from Dental Alloy: Two Case Reports
9
作者 Akinori Funayama Toshihiko Mikami +4 位作者 Kanae Niimi Hiroyuki Kano Yutaka Nikkuni Manabu Yamazaki Tadaharu Kobayashi 《Open Journal of Stomatology》 2016年第4期120-126,共7页
Pigmentation of the oral mucosa is relatively common and has a wide variety of etiologies. Although most pigmented lesions of the oral mucosa are associated with deposition of melanin and accidental displacement of a ... Pigmentation of the oral mucosa is relatively common and has a wide variety of etiologies. Although most pigmented lesions of the oral mucosa are associated with deposition of melanin and accidental displacement of a dental alloy, accurate differential diagnosis of a pigmented lesion is important, especially in the case of malignant melanoma. We report two cases of oral mucosal pigmentation associated with accidental displacement of a dental alloy in which malignant melanoma was suspected. Excisional biopsy was carried out in these cases with the incision line set at approximately 5 mm from the lesions. Histopathologically, brownish foreign substances were observed in the lamina propria. Metal quantitative analyses of the extracted specimens were carried out by electron probe microanalysis (EPMA). The metal components and the mass concentration revealed that the metals were derived from a dental casting silver alloy in Case 1 and from a gold-silver palladium alloy in Case 2. Although exogenous pigmentation originating from a dental alloy is not rare, differential diagnosis of oral pigmented lesions is sometimes very difficult. In such cases, histopathological examination may be necessary for the diagnosis to exclude melanocytic lesions and EPMA may be effective to identify the causative dental alloy. 展开更多
关键词 Intraoral Pigmentation Oral Melanoma dental alloy Oral Mucosa
下载PDF
Influence of Ni and Cr Content on Corrosion Resistance of Ni-Cr-Mo Alloys for Fixed Dental Prostheses in 0.05% NaF Aqueous Solution
10
作者 Nilo A. S. Sampaio José W. J. Silva +3 位作者 Heloisa A. Acciari Roberto Z. Nakazato Eduardo N. Codaro Hamilton de Felipe 《Materials Sciences and Applications》 2010年第6期369-372,共4页
The Ni-Cr-Mo alloys have been used as dental prostheses because they own a good mechanical strength, high corrosion resistance and even to be economically viable. These alloys corrosion protection against in salt solu... The Ni-Cr-Mo alloys have been used as dental prostheses because they own a good mechanical strength, high corrosion resistance and even to be economically viable. These alloys corrosion protection against in salt solutions typical of physiological media is due to passivation phenomenon with an oxide surface layer formation, mainly chromium oxides. This protective film, subjected to a mechanical stress in a corrosive environment, can partially dissolve by releasing ions, which have deleterious effects in a human body. Fluoride ions, existing in hygiene products, change the buccal environment and their presence may enable a localized corrosion process initiation. The aim of this work has been to investigate the chemical composition influence of three alloys in corrosion resistance to: A (Ni-73% Cr-14% Mo-8.5% Be-1.8% Al-1.8%), B (Ni-61% Cr-25% Mo-10.5% Si-1.5%) and C (Ni-65% Cr-22.5% Mo-9.5%) in media containing fluorides that simulate mouthwashes solution. The study has been done in a 0.05% NaF solution, pH 6, at 37°C using electrochemical techniques. The alloy with the highest nickel and the lowest chromium content is not passive in the middle studied, showing a continuous increase in current density with the potential increasing, while the other alloys show passivation range of 600 mV and passive current density of about 10-6 A/cm2. 展开更多
关键词 NI-CR-MO alloyS dental PROSTHESES Corrosion
下载PDF
Study on the Effect of Dental Metal Alloys on the Histamine Liberation of Blood Basophiles in Vitro
11
作者 DUBOVA L.V. LEBEDENKO I.Yu. +1 位作者 MAJIDOVA E.R. EVDOKIMOV A.I. 《贵金属》 CAS CSCD 北大核心 2012年第A01期237-239,共3页
Biomaterials for restoration or replacement of diseased tissues may have any origin.The major characteristic for biomaterials is biocompatibility.All biomaterials,used in medicine (dentistry,in particular),interreact ... Biomaterials for restoration or replacement of diseased tissues may have any origin.The major characteristic for biomaterials is biocompatibility.All biomaterials,used in medicine (dentistry,in particular),interreact with the organism tissues.And the changes occur both in the materials and the organism tissues.It is considered that there are no "inert biomaterials." The number of allergic diseases and complications is constantly growing all over the world,taking an important place in the structure of infectious and noninfectious pathology[1].Pollen,household,epidermal,and food-borne allergens,and haptens are the most frequent sources of sensibilization. 展开更多
关键词 Study on the Effect of dental Metal alloys on the Histamine Liberation of Blood Basophiles in Vitro
下载PDF
The Effect of Argon Inert Gas on the Laser Welding Quality of Co-Cr and Ni-Cr Base Metal Alloys
12
作者 Sklavou Efthymia Poulis Nikolas Prombonas Anthony 《Journal of Biomedical Science and Engineering》 2021年第12期442-451,共10页
The purpose of this research was to study the effect of Argon inert gas on the laser welding quality of Co-Cr and Ni-Cr base metal alloys, which are widely used as Fixed Prosthodontics alloys in Dental Laboratories. A... The purpose of this research was to study the effect of Argon inert gas on the laser welding quality of Co-Cr and Ni-Cr base metal alloys, which are widely used as Fixed Prosthodontics alloys in Dental Laboratories. A total of 36 specimens were manufactured (18 of Ni-Cr alloy and 18 of Co-Cr alloy). The specimens were then divided into 3 subgroups (6 specimens each): control;argon-welded;and non-Argon welded. The specimens were cut, laser welded, radiographed and finally tested under tensile strength testing, followed by examination using Scanning Electron Microscopy. The tensile strength of welded specimens was lower than the strength of non-welded specimens, however this difference was not found to be statistically significant. The material factor (Co-Cr alloy or Ni-Cr alloy) has a statistically significant effect on the tensile strength, while the presence or not of the inert gas, as well as the combination of the two factors do not have a statistically significant effect. The laser welding process applied in daily practice (separation of specimen, formation of two cones in contact, aggregation of two cones, filling of the remaining gap by welding) is considered satisfactory in terms of weld strength. The factor of the material, as an independent factor, affects the tensile strength to a statistically significant degree, in contrast to the factor of the presence of inert gas which does not affect to a statistically significant degree. 展开更多
关键词 Laser Welding co-cr alloys Ni-Cr alloys Mechanical Properties ARGON No Argon Environment
下载PDF
An analytical method for quantitative estimation of the cytotoxicity of dental alloys
13
作者 LU Xiao ying 1, H. F. Kappert 2 1 Key Laboratory for Molecular and Biomolecular Electronics of Ministre of Education,China Department of Biomedical Engineering, Southeast University, 210096 Nanjing, China 2 School of Dentistry, Albert Ludw 《Chinese Journal of Biomedical Engineering(English Edition)》 2002年第2期61-66,共6页
An analytical method for quantitative estimation of the cytotoxicity of dental alloys is introduced. After the TC50 values of 9 metal cations of various dental casting alloys were established using the MTT assay and t... An analytical method for quantitative estimation of the cytotoxicity of dental alloys is introduced. After the TC50 values of 9 metal cations of various dental casting alloys were established using the MTT assay and the concentrations of the corosively dissolved metal cations in the alloy extracts were measured by means of an ICP method. The cytotoxicity of dental alloys is induced as a function of the TC50 values and concentrations. The validity of the method is testified, by comparing the effective cytotoxicity of 19 dental alloys with those obtained directly by using MTT assay. 展开更多
关键词 dental alloyS CYTOTOXICITY QUANTITATIVE ANALYSIS
下载PDF
激光工艺参数对激光选区熔化牙科钴铬合金孔隙、表面粗糙度和硬度的影响
14
作者 桑磊 颜家振 +3 位作者 李宁 辛成来 王群 刘畅 《华西口腔医学杂志》 CAS CSCD 北大核心 2024年第4期462-469,共8页
目的为应对义齿加工厂在制备基于激光选区熔化(SLM)技术的牙科钴铬合金口腔修复体时因高孔隙率引发的质量问题,探究了不同成型工艺参数对材料微观结构及性能的影响机制,并据此精确界定了能够有效降低缺陷的口腔修复体成型工艺参数范围... 目的为应对义齿加工厂在制备基于激光选区熔化(SLM)技术的牙科钴铬合金口腔修复体时因高孔隙率引发的质量问题,探究了不同成型工艺参数对材料微观结构及性能的影响机制,并据此精确界定了能够有效降低缺陷的口腔修复体成型工艺参数范围。方法通过调整SLM过程中的打印参数,探讨激光功率、扫描速度以及扫描间距对牙科钴铬合金成型件孔隙特性、表面粗糙度及硬度的影响。借助金相微观分析结合图像分析和熔池模拟技术,揭示孔隙的形成机制,并阐明了SLM牙科钴铬合金孔隙率与能量密度之间的关联。结果线能量密度高于0.18 J/mm时,熔池底部易出现气孔缺陷;激光能量密度低于0.13 J/mm时,熔池间隙内则因粉末未充分熔化而产生缺陷。尤其是当线能量密度超出0.30 J/mm或低于0.12 J/mm的阈值时,孔隙率显著升高至超过1%。此外,SLM牙科钴铬合金的自由面粗糙度与能量密度之间呈负相关关系,宏观硬度与孔隙率之间呈反比关系。结论基于本研究采用的原材料及成型设备条件,成功确定了SLM成型件孔隙率低于1%的关键工艺参数。具体而言,这些关键参数涵盖了线能量密度,其取值范围为0.13~0.30J/mm,同时,扫描间距应严格控制在90μm以下。 展开更多
关键词 激光选区熔化 口腔修复体 牙科钴铬合金
下载PDF
Effect of hydrogen peroxide concentration on surface properties of Ni-Cr alloys
15
作者 何美凤 王浩 +2 位作者 江鸿 赵素 潘登 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2016年第5期1353-1358,共6页
The effect of concentration of hydrogen peroxide (H2O2) on the surface properties of Ni-Cr alloys was studied. Surface roughness and surface morphology of Ni-Cr alloys were evaluated by surface profiler and scanning... The effect of concentration of hydrogen peroxide (H2O2) on the surface properties of Ni-Cr alloys was studied. Surface roughness and surface morphology of Ni-Cr alloys were evaluated by surface profiler and scanning electron microscopy after being immersed in different concentrations of H2O2 for 112 h. Surface corrosion products of Ni-Cr alloys were analyzed by photoelectron spectrograph after being immersed in 0% and 30% H2O2. The order of increasing surface roughness of Ni-Cr alloys after being immersed in different concentrations of H2O2 was 0〈3.6%〈10%〈30%. As the concentration of hydrogen peroxide increased, the surface roughness of Ni-Cr alloys increased and the surface morphology showed different degrees of corrosion. According to the XPS results, the corrosion products formed on the outmost surface layer of the studied samples are Ni(OH)2 and BeO. 展开更多
关键词 hydrogen peroxide (H2O2) dental Ni-Cr alloys surface roughness surface morphology surface corrosion products
下载PDF
热处理工艺对SLM打印成形CoCrMoW显微结构和力学性能的影响
16
作者 邱芷薇 《材料研究与应用》 CAS 2024年第5期769-776,共8页
CoCrMoW合金是烤瓷牙金属基底和可拆卸活动支架的理想材料。针对SLM成形CoCrMoW合金的热处理工艺,尤其是较长的时效时间导致的生产效率过低,以及热处理后SLM成形件尺寸一致性和翘曲变形程度等问题,对热处理后的合金性能进行了研究。以... CoCrMoW合金是烤瓷牙金属基底和可拆卸活动支架的理想材料。针对SLM成形CoCrMoW合金的热处理工艺,尤其是较长的时效时间导致的生产效率过低,以及热处理后SLM成形件尺寸一致性和翘曲变形程度等问题,对热处理后的合金性能进行了研究。以气雾化CoCrMoW合金粉末(粒度15—53μm)为原材料,采用SLM方法打印CoCrMoW合金试样,并将其分别在920、960和1000℃下进行热处理并保温1 h,随炉冷却至600℃后取出。采用SEM、EDS和拉伸测试等方法,研究热处理工艺对SLM打印态CoCrMoW合金的显微结构及力学性能的影响。结果表明:热处理后合金基体的晶内、晶界均析出了第二相颗粒,在温度920和960℃下析出相颗粒分布均匀且密集,而在温度1000℃下晶内部分析出相溶解;随着热处理温度的提高,析出相明显生长得更加粗大。根据EDS成分分析,判断析出相为金属间化合物Co_(3)(Mo,W)_(2)Si。不同热处理条件下,试样的力学性能有明显差异,并且与析出相的分布、数量、尺寸密切相关。当在920℃下进行热处理时,密集细小的析出相对基体的强化效果最为显著,表现为最高的屈服强度(1134 MPa)、最低的塑性(延伸率7%),断口为脆性倾向的准解理断裂。随着热处理温度升高,析出相发生了粗化且部分溶解,试样的强度逐渐下降,而塑性逐渐提升。在1000℃下进行热处理时,合金的力学性能恢复至接近打印态水平,屈服强度892 MPa、延伸率14.8%,断口为韧性倾向的准解理断裂,此时合金兼具高强度和高塑韧性。此外,较高的热处理温度可以更有效地释放残余应力,减小翘曲变形,经1000℃热处理后的试样形变量最小(0.13 mm)。热处理条件对SLM成形CoCrMoW合金的性能和形变控制至关重要,可以根据不同应用需求进行选择。 展开更多
关键词 CoCrMoW合金 齿科材料 激光选区熔化 热处理 显微结构 力学性能 翘曲变形 残余应力
下载PDF
Osteoblast integration of dental implant materials after challenge by sub-gingival pathogens: a co-culture study in vitro 被引量:1
17
作者 Bingran Zhao Henny C van der Mei +2 位作者 Minie Rustema-Abbing Henk J Busscher Yijin Ren 《International Journal of Oral Science》 SCIE CAS CSCD 2015年第4期250-258,共9页
Sub-gingival anaerobic pathogens can colonize an implant surface to compromise osseointegration of dental implants once the soft tissue seal around the neck of an implant is broken. In vitro evaluations of implant mat... Sub-gingival anaerobic pathogens can colonize an implant surface to compromise osseointegration of dental implants once the soft tissue seal around the neck of an implant is broken. In vitro evaluations of implant materials are usually done in monoculture studies involving either tissue integration or bacterial colonization. Co-culture models, in which tissue cells and bacteria battle simultaneously for estate on an implant surface, have been demonstrated to provide a better in vitro mimic of the clinical situation. Here we aim to compare the surface coverage by U2OS osteoblasts cells prior to and after challenge by two anaerobic sub-gingival pathogens in a co-culture model on differently modified titanium (Ti), titanium-zirconium (TiZr) alloys and zirconia surfaces. Monoculture studies with either U2OS osteoblasts or bacteria were also carried out and indicated significant differences in biofilm formation between the implant materials, but interactions with U2OS osteoblasts were favourable on all materials. Adhering U2OS osteoblasts cells, however, were significantly more displaced from differently modified Ti surfaces by challenging sub-gingival pathogens than from TiZr alloys and zirconia variants. Combined with previous work employing a co-culture model consisting of human gingival fibroblasts and supra-gingival oral bacteria, results point to a different material selection to stimulate the formation of a soft tissue seal as compared to preservation of osseointegration under the unsterile conditions of the oral cavity. 展开更多
关键词 biofilm CO-CULTURE dental implant OSTEOBLASTS sub-gingival pathogens titanium-zirconium alloy
下载PDF
Estimation of the Patients'Adaptation to Noble Alloy Dentures Relying on the Parameters of Biological Fluids in Oral Cavities 被引量:1
18
作者 LEBEDENKO I.Yu. PARUNOV V.A. KITKINA T.B. 《贵金属》 CAS CSCD 北大核心 2012年第A01期246-249,共4页
For the study of the effect of Plagodent and Palladent noble alloy dentures (OJSC "SIC 'Supermetal'", Russia), the elemental compositions of the fluids obtained from gingival sulcus of abutment teeth... For the study of the effect of Plagodent and Palladent noble alloy dentures (OJSC "SIC 'Supermetal'", Russia), the elemental compositions of the fluids obtained from gingival sulcus of abutment teeth of metal ceramic dentures with frames made of the above-stated dental alloys, have been investigated. Response of white blood cells and fibroblasts in the gingival fluid and the mixed saliva of the patients a long time after prosthetic repair, relying on the content of proinflammatory interleukins IL-1 β and IL-6, anti-inflammatory interleukins IL-4 and IL-10, the factor of tumor necrosis TNF-α and lactoferrin, has been investigated. The results obtained have convincingly proved the biosafety of the Plagodent and Palladent noble alloys. 展开更多
关键词 noble dental alloys BIOCOMPATIBILITY gingival fluid INTERLEUKINS LACTOFERRIN
下载PDF
Nanostructure and corrosion behaviors of nanotube formed Ti-Zr alloy 被引量:5
19
作者 Won-Gi KIM Han-Cheol CHOE 《中国有色金属学会会刊:英文版》 EI CSCD 2009年第4期1005-1008,共4页
In order to investigate the nanostructures and corrosion behaviors of Ti-Zr alloys,nanotube formed Ti-Zr(10%,20%,30% and 40% in mass fraction) alloys were prepared by arc melting and the condition of controlling nanos... In order to investigate the nanostructures and corrosion behaviors of Ti-Zr alloys,nanotube formed Ti-Zr(10%,20%,30% and 40% in mass fraction) alloys were prepared by arc melting and the condition of controlling nanostructure was at 1 000 ℃ for 24 h in argon atmosphere;formation of nanotubes was conducted by anodizing a Ti-Zr alloy in H3PO4 electrolyte with a small amount of fluoride ions at room temperature.The corrosion properties of specimens were examined through potentiodynamic test(potential range of -1 500-2 000 mV) in 0.9% NaCl solution by using potentiostat.Microstructures of the alloys were observed by optical microscope(OM),field emission scanning electron microscope(FE-SEM) and X-ray diffractometer(XRD).Diameter of nanotube does not depend on Zr content,but interspace of nanotube predominantly depends on Zr content,which confirms that ZrO2 oxides play a role to increase the interspace of nanotube formed on the surface. 展开更多
关键词 钛锆合金 纳米结构 腐蚀行为 扫描电子显微镜 NACL溶液 阳极氧化 光学显微镜 X射线衍射
下载PDF
Analysis of Deformation in Ni-Cr Structures with New and Recast Alloys
20
作者 Humberto Gennari Filho Marcelo Coelho Goiato +1 位作者 José Vitor Quinelli Mazaro Karina Helga Leal Túrcio 《Materials Sciences and Applications》 2015年第7期707-712,共6页
The present study analyzed new and recast Ni-Cr alloys, regarding the relationship between the applied force and the deformation in cantilevered bar segments, with dimensions of 4.0 mm, 3.5 mm, 3.0 mm in thickness, 4.... The present study analyzed new and recast Ni-Cr alloys, regarding the relationship between the applied force and the deformation in cantilevered bar segments, with dimensions of 4.0 mm, 3.5 mm, 3.0 mm in thickness, 4.5 mm width and 15 mm length, on a universal testing machine “EMIC”. The bars in the tests were initially obtained acrylic resin by 4.8 mm wide × 4.3 mm thick × 4 cm long. We obtained 30 bars divided into two groups, with 15 to test new alloys and 15 with alloys recast. The alloy used was Tilite. For the application of the load, the bars were attached to “EMIC” where the active tip of 200 kgf load cell was at a specific point of the bar (15 mm) with a speed of 0.5 mm per minute. The data showed statistically significant differences in relation to alloys and thickness among the bars, and all thicknesses evaluated were different. Thus, it was concluded that there was statistically significant difference between the groups and their variables, and that the alloys recast could be reused at least 1 time, without loss of properties. 展开更多
关键词 alloyS ORAL Protheses dental Materials
下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部