期刊文献+
共找到2,459篇文章
< 1 2 123 >
每页显示 20 50 100
Multiformity of Optical Quantum Coherence Systems with Y and Inverted Y-type Schemes
1
作者 刘晓东 孟冬冬 +2 位作者 张森林 陶万军 戚桢 《Communications in Theoretical Physics》 SCIE CAS CSCD 2010年第8期273-277,共5页
Y and inverted Y-type four-level schemes for optical quantum coherence systems,which may be intuitivelyconsidered to be very simple,have not been studied intensively till now.In this paper,we present the multiformity ... Y and inverted Y-type four-level schemes for optical quantum coherence systems,which may be intuitivelyconsidered to be very simple,have not been studied intensively till now.In this paper,we present the multiformity ofthese two types of schemes by considering that they can be classified into nine possible level styles as the second-ordersub-schemes using laser fields.Further we point out the complexity of their more than one hundred realistic configurationsas the third-order four-level sub-schemes that may appear in the optical quantum coherence experiments.Throughoutthis paper we review which configurations have been studied in some research aspects and which ones not,accordingto our knowledge,in order to be propitious to next steps of theoretical and experimental investigations,especially forapplications in the fields of quantum optics,quantum information science,laser spectroscopy,and so on. 展开更多
关键词 quantum coherence level configuration four-level scheme quantum optics quantum informationscience
下载PDF
Intravascular photoacoustic and optical coherence tomography imaging dual-mode system for detecting spontaneous coronary artery dissection: A feasibility study 被引量:1
2
作者 Yongwei Wang Yuyang Wan Zhongjiang Chen 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期77-86,共10页
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ... In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications. 展开更多
关键词 Spontaneous coronary artery dissection(SCAD) intravascular optical coherence tomography(IVOCT) intravascular photoacoustic imaging(IVPAI)
下载PDF
Quantum block coherence with respect to projective measurements
3
作者 王璞 李忠艳 孟会贤 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期213-220,共8页
Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the co... Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the context of projective measurements,focusing on the quantification of such coherence.Firstly,we define the correlation function between the two general projective measurements P and Q,and analyze the connection between sets of block incoherent states related to two compatible projective measurements P and Q.Secondly,we discuss the measure of quantum block coherence with respect to projective measurements.Based on a given measure of quantum block coherence,we characterize the existence of maximal block coherent states through projective measurements.This research integrates the compatibility of projective measurements with the framework of quantum block coherence,contributing to the advancement of block coherence measurement theory. 展开更多
关键词 quantum coherence compatibility projective measurement quantum block coherence
下载PDF
Aflibercept combined with triamcinolone acetonide in the treatment of diabetic macular edema:optical coherence tomography and optical coherence tomography angiography
4
作者 De-Shuang Li Hong-Xia Liao +4 位作者 Chuan-He Zhang Jian-Guo Huang Wei Chen Jing-Lin Zhang Bo Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期670-675,共6页
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone... AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography hyperreflective foci subretinal fluid foveal avascular zone AFLIBERCEPT
下载PDF
Automatic diagnosis of diabetic retinopathy using vision transformer based on wide-field optical coherence tomography angiography
5
作者 Zenan Zhou Huanhuan Yu +3 位作者 Jiaqing Zhao Xiangning Wang Qiang Wu Cuixia Dai 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期35-44,共10页
Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,... Diabetic retinopathy(DR)is one of the major causes of visual impairment in adults with diabetes.Optical coherence tomography angiography(OCTA)is nowadays widely used as the golden criterion for diagnosing DR.Recently,wide-field OCTA(WF-OCTA)provided more abundant information including that of the peripheral retinal degenerative changes and it can contribute in accurately diagnosing DR.The need for an automatic DR diagnostic system based on WF-OCTA pictures attracts more and more attention due to the large diabetic population and the prevalence of retinopathy cases.In this study,automatic diagnosis of DR using vision transformer was performed using WF-OCTA images(12 mm×12 mm single-scan)centered on the fovea as the dataset.WF-OCTA images were automatically classified into four classes:No DR,mild nonproliferative diabetic retinopathy(NPDR),moderate to severe NPDR,and proliferative diabetic retinopathy(PDR).The proposed method for detecting DR on the test set achieves accuracy of 99.55%,sensitivity of 99.49%,and specificity of 99.57%.The accuracy of the method for DR staging reaches up to 99.20%,which has been proven to be higher than that attained by classical convolutional neural network models.Results show that the automatic diagnosis of DR based on vision transformer and WF-OCTA pictures is more effective for detecting and staging DR. 展开更多
关键词 Wide field optical coherence tomography angiography diabetic retinopathy vision transformer image classification
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images
6
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
Evaluation of retinal and choroidal thickness changes in overweight and obese adults without ocular symptoms by swept-source optical coherence tomography
7
作者 Qing-Jian Li Sheng-Mei Zhou +7 位作者 Ling-Yu Zhang An-Ni Lin Yang Zhang Jing Jiang Xin Che Yi-Wen Qian Yan Liu Zhi-Liang Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期707-712,共6页
AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass... AIM:To evaluate the relationship of overweight and obesity with retinal and choroidal thickness in adults without ocular symptoms by swept-source optical coherence tomography(SS-OCT).METHODS:According to the body mass index(BMI)results,the adults enrolled in the cross-sectional study were divided into the normal group(18.50≤BMI<25.00 kg/m^(2)),the overweight group(25.00≤BMI<30.00 kg/m^(2)),and the obesity group(BMI≥30.00 kg/m^(2)).The one-way ANOVA and the Chi-square test were used for comparisons.Pearson’s correlation analysis was used to evaluate the relationships between the measured variables.RESULTS:This research covered the left eyes of 3 groups of 434 age-and sex-matched subjects each:normal,overweight,and obesity.The mean BMI was 22.20±1.67,26.82±1.38,and 32.21±2.35 kg/m^(2) in normal,overweight and obesity groups,respectively.The choroid was significantly thinner in both the overweight and obesity groups compared to the normal group(P<0.05 for all),while the retinal thickness of the three groups did not differ significantly.Pearson’s correlation analysis showed that BMI was significantly negatively correlated with choroidal thickness,but no significant correlation was observed between BMI and retinal thickness.CONCLUSION:Choroidal thickness is decreased in people with overweight or obesity.Research on changes in choroidal thickness contributes to the understanding of the mechanisms of certain ocular disorders in overweight and obese adults. 展开更多
关键词 OVERWEIGHT OBESITY body mass index choroidal thickness retinal thickness swept-source optical coherence tomography
下载PDF
Predictive visual field outcomes after optic chiasm decompressive surgery by retinal vessels parameters using optical coherence tomography angiography
8
作者 Wen-Juan Yu Jin Xiao +3 位作者 Guang-Xin Wang Chang Jiang Wei Zha Rong-Feng Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期365-373,共9页
AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary ne... AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary nerve fiber layer(pRNFL)and ganglion cell complex(GCC).METHODS:This prospective longitudinal observational study included patients with chiasmal compression due to sellar region mass scheduled for decompressive surgery.Generalized estimating equations were used to compare retinal vessel density and retinal layer thickness preand post-operatively and with healthy controls.Logistic regression models were used to assess the relationship between preoperative GCC,pRNFL,SRCP,and RPC parameters and visual field recovery after surgery.RESULTS:The study included 43 eyes of 24 patients and 48 eyes of 24 healthy controls.Preoperative RPC and SRCP vessel density and pRNFL and GCC thickness were lower than healthy controls and higher than postoperative values.The best predictive GCC and pRNFL models were based on the superior GCC[area under the curve(AUC)=0.866]and the tempo-inferior pRNFL(AUC=0.824),and the best predictive SRCP and RPC models were based on the nasal SRCP(AUC=0.718)and tempo-inferior RPC(AUC=0.825).There was no statistical difference in the predictive value of the superior GCC,tempo-inferior pRNFL,and tempo-inferior RPC(all P>0.05).CONCLUSION:Compression of the optic chiasm by tumors in the saddle area can reduce retinal thickness and blood perfusion.This reduction persists despite the recovery of the visual field after decompression surgery.GCC,pRNFL,and RPC can be used as sensitive predictors of visual field recovery after decompression surgery. 展开更多
关键词 sellar region mass retinal vessels optic chiasm optical coherence tomography angiography visual field decompressive surgery
下载PDF
Repeatability,interocular correlation and agreement of optic nerve head vessel density in healthy eyes:a sweptsource optical coherence tomographic angiography study
9
作者 Dan-Qi Fang Da-Wei Yang +2 位作者 Xiao-Ting Mai Carol Y Cheung Hao-Yu Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期896-903,共8页
AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-thre... AIM:To assess the repeatability,interocular correlation,and agreement of quantitative swept-source optical coherence tomography angiography(OCTA)optic nerve head(ONH)parameters in healthy subjects.METHODS:Thir ty-three healthy subjects were enrolled.The ONH of both eyes were imaged four times by a swept-source-OCTA using a 3 mm×3 mm scanning protocol.Images of the radial peripapillary capillary were analyzed by a customized Matlab program,and the vessel density,fractal dimension,and vessel diameter index were measured.The repeatability of the four scans was determined by the intraclass correlation coefficient(ICC).The most well-centered optic disc from the four repeated scans was then selected for the interocular correlation and agreement analysis using the Pearson correlation coefficient,ICC and Bland-Altman plots.RESULTS:All swept-source-OCTA ONH parameters exhibited certain repeatability,with ICC>0.760 and coefficient of variation(CoV)≤7.301%.The obvious interocular correlation was observed for papillary vessel density(ICC=0.857),vessel diameter index(ICC=0.857)and fractal dimension(ICC=0.906),while circumpapillary vessel density exhibited moderate interocular correlation(ICC=0.687).Bland-Altman plots revealed an agreement range of-5.26%to 6.21%for circumpapillary vessel density.CONCLUSION:OCTA ONH parameters demonstrate good repeatability in healthy subjects.The interocular correlations of papillary vessel density,fractal dimension and vessel diameter index are high,but the correlation for circumpapillary vessel density is moderate. 展开更多
关键词 interocular correlation REPEATABILITY optic nerve head optical coherence tomography angiography vessel density
下载PDF
Artificial intelligence for the detection of glaucoma with SD-OCT images:a systematic review and Meta-analysis
10
作者 Nan-Nan Shi Jing Li +1 位作者 Guang-Hui Liu Ming-Fang Cao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期408-419,共12页
●AIM:To quantify the performance of artificial intelligence(AI)in detecting glaucoma with spectral-domain optical coherence tomography(SD-OCT)images.●METHODS:Electronic databases including PubMed,Embase,Scopus,Scien... ●AIM:To quantify the performance of artificial intelligence(AI)in detecting glaucoma with spectral-domain optical coherence tomography(SD-OCT)images.●METHODS:Electronic databases including PubMed,Embase,Scopus,ScienceDirect,ProQuest and Cochrane Library were searched before May 31,2023 which adopted AI for glaucoma detection with SD-OCT images.All pieces of the literature were screened and extracted by two investigators.Meta-analysis,Meta-regression,subgroup,and publication of bias were conducted by Stata16.0.The risk of bias assessment was performed in Revman5.4 using the QUADAS-2 tool.●RESULTS:Twenty studies and 51 models were selected for systematic review and Meta-analysis.The pooled sensitivity and specificity were 0.91(95%CI:0.86–0.94,I2=94.67%),0.90(95%CI:0.87–0.92,I2=89.24%).The pooled positive likelihood ratio(PLR)and negative likelihood ratio(NLR)were 8.79(95%CI:6.93–11.15,I2=89.31%)and 0.11(95%CI:0.07–0.16,I2=95.25%).The pooled diagnostic odds ratio(DOR)and area under curve(AUC)were 83.58(95%CI:47.15–148.15,I2=100%)and 0.95(95%CI:0.93–0.97).There was no threshold effect(Spearman correlation coefficient=0.22,P>0.05).●CONCLUSION:There is a high accuracy for the detection of glaucoma with AI with SD-OCT images.The application of AI-based algorithms allows together with“doctor+artificial intelligence”to improve the diagnosis of glaucoma. 展开更多
关键词 artificial intelligence spectral-domain optical coherence tomography GLAUCOMA META-ANALYSIS
下载PDF
Distal-scanning common path probe for optical coherence tomography
11
作者 Zhengyu Chen Bin He +8 位作者 Zichen Yin Zhangwei Hu Yejiong Shi Chengming Wang Xiao Zhang Ning Zhang Linkai Jing Guihuai Wang Ping Xue 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期84-92,共9页
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be... In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus. 展开更多
关键词 Common path optical coherence tomography endoscopic probe
下载PDF
Three-dimensional choroidal vascularity index and choroidal thickness in fellow eyes of acute and chronic primary angle-closure using swept-source optical coherence tomography
12
作者 Hai-Li Huang Guan-Hong Wang +1 位作者 Liang-Liang Niu Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期42-52,共11页
AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of... AIM:To compare the three-dimensional choroidal vascularity index(CVI)and choroidal thickness between fellow eyes of acute primary angle-closure(F-APAC)and chronic primary angle-closure glaucoma(F-CPACG)and the eyes of normal controls.METHODS:This study included 37 patients with unilateral APAC,37 with asymmetric CPACG without prior treatment,and 36 healthy participants.Using swept-source optical coherence tomography(SS-OCT),the macular and peripapillary choroidal thickness and three-dimensional CVI were measured and compared globally and sectorally.Pearson’s correlation analysis and multivariate regression models were used to evaluate choroidal thickness or CVI with related factors.RESULTS:The mean subfoveal CVIs were 0.35±0.10,0.33±0.09,and 0.29±0.04,and the mean subfoveal choroidal thickness were 315.62±52.92,306.22±59.29,and 262.69±45.55μm in the F-APAC,F-CPACG,and normal groups,respectively.All macular sectors showed significantly higher CVIs and choroidal thickness in the F-APAC and F-CPACG eyes than in the normal eyes(P<0.05),while there were no significant differences between the F-APAC and F-CPACG eyes.In the peripapillary region,the mean overall CVIs were 0.21±0.08,0.20±0.08,and 0.19±0.05,and the mean overall choroidal thickness were 180.45±54.18,174.82±50.67,and 176.18±37.94μm in the F-APAC,F-CPACG,and normal groups,respectively.There were no significant differences between any of the two groups in all peripapillary sectors.Younger age,shorter axial length,and the F-APAC or F-CPACG diagnosis were significantly associated with higher subfoveal CVI and thicker subfoveal choroidal thickness(P<0.05).CONCLUSION:The fellow eyes of unilateral APAC or asymmetric CPACG have higher macular CVI and choroidal thickness than those of the normal controls.Neither CVI nor choroidal thickness can distinguish between eyes predisposed to APAC or CPACG.A thicker choroid with a higher vascular volume may play a role in the pathogenesis of primary angle-closure glaucoma. 展开更多
关键词 choroidal thickness choroidal vascularity index swept-source optical coherence tomography acute primary angle-closure chronic primary angle-closure glaucoma
下载PDF
Detecting early changes in choroidal vascularity and thickness using optical coherence tomography in patients with corneal crosslinking for keratoconus
13
作者 Selim Doganay Mehmet Omer Kiristioglu +1 位作者 Derya Doganay Elif Kacmaz 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1267-1272,共6页
AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal cr... AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance. 展开更多
关键词 KERATOCONUS corneal crosslinking choroidal vascularity index enhanced depth imaging optical coherence tomography
下载PDF
Automated evaluation of parapapillary choroidal microvasculature in crowded optic discs:a controlled,optical coherence tomography angiography study
14
作者 Hatice Arda Hidayet Sener +5 位作者 Ozge Temizyurek Hatice Kubra Sonmez Duygu Gulmez Sevim Cem Evereklioglu Fatih Horozoglu Ayse Busra Gunay Sener 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期113-118,共6页
AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control... AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control subjects were enrolled in the study.One eye of each individual was included and OCT-A scans of optic discs were obtained in a 4.5×4.5 mm^(2) rectangular area.Radial peripapillary capillary(RPC)density,peripapillary retinal nerve fiber layer(pRNFL)thickness,cup volume,rim area,disc area,cup-to-disc(c/d)area ratio,and vertical c/d ratio were obtained automatically using device software.Automated parapapillary choroidal microvasculature(PPCMv)density was calculated using MATLAB software.When the vertical c/d ratio of the optic disc was absent or small cup,it was considered as a crowded disc.RESULTS:The mean signal strength index of OCT-A images was similar between the crowded discs and control eyes(P=0.740).There was no difference in pRNFL between the two groups(P=0.102).There were no differences in RPC density in whole image(P=0.826)and peripapillary region(P=0.923),but inside disc RPC density was higher in crowded optic discs(P=0.003).The PPCMv density in the inner-hemisuperior region was also lower in crowded discs(P=0.026).The pRNFL thickness was positively correlated with peripapillary RPC density(r=0.498,P<0.001).The inside disc RPC density was negatively correlated with c/d area ratio(r=-0.341,P=0.002).CONCLUSION:The higher inside disc RPC density and lower inner-hemisuperior PPCMv density are found in eyes with crowded optic discs. 展开更多
关键词 crowded optic disc ischemic optic neuropathy optical coherence tomography angiography parapapillary choroidal microvasculature
下载PDF
Automatic fovea detection and choroid segmentation for choroidal thickness assessment in optical coherence tomography
15
作者 Chen Yu Lin Hung Ju Chen +3 位作者 Yi Kit Chan Wei Ping Hsia Yu Len Huang Chia Jen Chang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第10期1763-1771,共9页
AIM:To develop an automated model for subfoveal choroidal thickness(SFCT)detection in optical coherence tomography(OCT)images,addressing manual fovea location and choroidal contour challenges.METHODS:Two procedures we... AIM:To develop an automated model for subfoveal choroidal thickness(SFCT)detection in optical coherence tomography(OCT)images,addressing manual fovea location and choroidal contour challenges.METHODS:Two procedures were proposed:defining the fovea and segmenting the choroid.Fovea localization from B-scan OCT image sequence with three-dimensional reconstruction(LocBscan-3D)predicted fovea location using central foveal depression features,and fovea localization from two-dimensional en-face OCT(LocEN-2D)used a mask region-based convolutional neural network(Mask R-CNN)model for optic disc detection,and determined the fovea location based on optic disc relative position.Choroid segmentation also employed Mask R-CNN.RESULTS:For 53 eyes in 28 healthy subjects,LocBscan-3D’s mean difference between manual and predicted fovea locations was 170.0μm,LocEN-2D yielded 675.9μm.LocEN-2D performed better in non-high myopia group(P=0.02).SFCT measurements from Mask R-CNN aligned with manual values.CONCLUSION:Our models accurately predict SFCT in OCT images.LocBscan-3D excels in precise fovea localization even with high myopia.LocEN-2D shows high detection rates but lower accuracy especially in the high myopia group.Combining both models offers a robust SFCT assessment approach,promising efficiency and accuracy for large-scale studies and clinical use. 展开更多
关键词 subfoveal choroidal thickness optical coherence tomography automatic foveal detection automatic choroid segmentation
下载PDF
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
16
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
下载PDF
Retinal capillary plexus in Parkinson’s disease using optical coherence tomography angiography
17
作者 Ioannis Giachos Spyridon Doumazos +6 位作者 Anastasia Tsiogka Konstantina Manoli George Tagaris Tryfon Rotsos Vassilios Kozobolis Ioannis Iliopoulos Marilita Moschos 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期131-136,共6页
AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of... AIM:To evaluate the alterations of the retinal microvasculature and foveal avascular zone in patients with Parkinson’s disease(PD)using optical coherence tomography angiography(OCT-A).METHODS:A retrospective study of PD patients examined in the Ophthalmology Department of the General Hospital of Athens,“Georgios Gennimatas”from March 2021 to March 2022 was conducted.Totally 44 patients with PD were included and 18 healthy controls were examined,hence a total of 124 eyes were enrolled in the study.The foveal and parafoveal superficial and deep capillary plexus vascular density(fSCP-VD,fDCP-VD,pSCP-VD,pDCP-CD)and foveal avascular zone(FAZ)were quantified with OCTA.Optical coherence tomography(OCT)was used to measure macular thickness.Our statistical analysis was conducted by using a mixed effect linear regression model.RESULTS:After adjustment for age and gender,the mean parafoveal superficial capillary plexus vascular density(pSCP-VD)and mean parafoveal deep capillary plexus vascular density(pDCP-VD)were significantly decreased in individuals with PD(P<0.001 in both)by-2.35(95%CI-3.3,-1.45)and-7.5(95%CI-10.4,-4.6)respectively.fSCP-VD and fDCP-VD didn’t approach statistical significance.The FAZ area and perimeter were significantly decreased(P<0.001 in both)by-0.1 mm^(2)(95%CI-0.13,-0.07)and-0.49 mm^(2)(95%CI-0.66,-0.32)respectively.Circularity didn’t approach statistical significance.Central retinal thickness(CRT)was significantly decreased in individuals with PD(P<0.001)by-23.1μm(95%CI-30.2,-16)and temporal retinal thickness(TRT)was decreased(P=0.025)by-11μm(95%CI-22,-1.5)while nasal retinal thickness(NRT)only approached statistical significance(P=0.066).CONCLUSION:The mean pSCP-VD,pDCP-VD,CRT and TRT are significantly decreased and FAZ is altered in individuals with PD.These findings can be potentially used as biomarkers for the diagnosis and evaluation of early PD. 展开更多
关键词 Parkinson’s disease optical coherence tomography angiography retinal vascular density foveal avascular zone
下载PDF
Effectively modulating spatial vortex four-wave mixing in a diamond atomic system
18
作者 巴诺 姜明奇 +4 位作者 费金友 王丹 蒋海林 王磊 王海华 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期473-478,共6页
Due to the spatial characteristics of orbital angular momentum,vortex fields can be applied in the fields of quantum storage and quantum information.We study the realization of spatially modulated vortex fields based ... Due to the spatial characteristics of orbital angular momentum,vortex fields can be applied in the fields of quantum storage and quantum information.We study the realization of spatially modulated vortex fields based on four-wave mixing in a four-level atomic system with a diamond structure.The intensity and spiral phase of the vortex field are effectively transferred to the generated four-wave mixing field.By changing the detuning of the probe field,the phase and intensity of the generated vertex four-wave mixing field can be changed.When the probe field takes a large detuning value,the spatial distribution of the intensity and phase of the vertex four-wave mixing field can be effectively tuned by adjusting the Rabi frequency or detuning value of the coupled field.At the same time,we also provide a detailed explanation based on the dispersion relationship,and the results agree well with our simulation results. 展开更多
关键词 coherent optical effects four-wave mixing orbital angular momentum
下载PDF
Quantitative determination of the critical points of Mott metal–insulator transition in strongly correlated systems
19
作者 牛月坤 倪煜 +4 位作者 王建利 陈雷鸣 邢晔 宋筠 冯世平 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期647-652,共6页
Mottness is at the heart of the essential physics in a strongly correlated system as many novel quantum phenomena occur in the metallic phase near the Mott metal–insulator transition. We investigate the Mott transiti... Mottness is at the heart of the essential physics in a strongly correlated system as many novel quantum phenomena occur in the metallic phase near the Mott metal–insulator transition. We investigate the Mott transition in a Hubbard model by using the dynamical mean-field theory and introduce the local quantum state fidelity to depict the Mott metal–insulator transition. The local quantum state fidelity provides a convenient approach to determining the critical point of the Mott transition. Additionally, it presents a consistent description of the two distinct forms of the Mott transition points. 展开更多
关键词 critical point metal–insulator transition local quantum state fidelity strongly correlated system quasiparticle coherent weight
下载PDF
Optical coherence tomography in detection of dysplasia and cancer of the gastrointestinal tract and bilio-pancreatic ductal system 被引量:19
20
作者 Pier Alberto Testoni Benedetto Mangiavillano 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第42期6444-6452,共9页
Optical coherence tomography(OCT) is an optical imaging modality that performs high-resolution,cross-sectional,subsurface tomographic imaging of the microstructure of tissues.The physical principle of OCT is similar t... Optical coherence tomography(OCT) is an optical imaging modality that performs high-resolution,cross-sectional,subsurface tomographic imaging of the microstructure of tissues.The physical principle of OCT is similar to that of B-mode ultrasound imaging,except that it uses infrared light waves rather than acoustic waves.The in vivo resolution is 10-25 times better(about 10 μm) than with high-frequency ultrasound imaging,but the depth of penetration is limited to 1-3 mm,depending upon tissue structure,depth of focus of the probe used,and pressure applied to the tissue surface.In the last decade,OCT technology has evolved from an experimental laboratory tool to a new diagnostic imaging modality with a wide spectrum of clinical applications in medical practice,including the gastrointestinal(GI) tract and pancreatic-biliary ductal system.OCT imaging from the GI tract can be done in humans by using narrow-diameter,catheter-based probes that can be inserted through the accessory channel of either a conventional front-view endoscope,for investigating the epithelial structure of the GI tract,or a side-view endoscope,inside a standard transparent ERCP catheter,for investigating the pancreatico-biliary ductal system.Esophagus and the esophago-gastric junction has been the most widely investigated organ so far;more recently,also duodenum,colon and pancreatico-biliary ductal system have been extensively investigated.OCT imaging of the gastro-intestinal wall structure is characterized by a multiple-layer architecture that permits an accurate evaluation of the mucosa,lamina propria,muscularis mucosae,andpart of the submucosa.The technique may be,therefore,used to identify pre-neoplastic conditions of the GI tract,such as Barrett's epithelium and dysplasia,and evaluate the depth of penetration of early-stage neoplastic lesions.OCT imaging of the pancreatic and biliary ductal system could improve the diagnostic accuracy for ductal epithelial changes and the differential diagnosis between neoplastic and non-neoplastic lesions. 展开更多
关键词 Optical coherence tomography Barrett'sepithelium DYSPLASIA Adenocarcinoma Gastrointestinal tract Pancreatico-biliary ductal system
下载PDF
上一页 1 2 123 下一页 到第
使用帮助 返回顶部