The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstation...The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstations covering a range of 100–620 eV for ultrafast X-ray science.Two undulator lines are designed and constructed,based on different lasing modes:self-amplified spontaneous emission and echo-enabled harmonic generation.The coherent scattering and imaging(CSI)endstation is the first of five endstations to be commissioned online.It focuses on high-resolution single-shot imaging and the study of ultrafast dynamic processes using coherent forward scattering techniques.Both the single-shot holograms and coherent diffraction patterns were recorded and reconstructed for nanoscale imaging,indicating the excellent coherence and high peak power of the SXFEL and the possibility of‘‘diffraction before destruction’’experiments at the CSI endstation.In this study,we report the first commissioning results of the CSI endstation.展开更多
Coherent diffractive imaging (CDI) is a lensless imaging technique and can achieve a resolution beyond the Rayleigh or Abbe limit. The ptychographical iterative engine (PIE) is a CDI phase retrieval algorithm that...Coherent diffractive imaging (CDI) is a lensless imaging technique and can achieve a resolution beyond the Rayleigh or Abbe limit. The ptychographical iterative engine (PIE) is a CDI phase retrieval algorithm that uses multiple diffraction patterns obtained through the scan of a localized illumination on the specimen, which has been demonstrated successfully at optical and X-ray wavelengths. In this paper, a general PIE algorithm (gPIE) is presented and demonstrated with an He-Ne laser light diffraction dataset. This algorithm not only permits the removal of the accurate model of the illumination function in PIE, but also provides improved convergence speed and retrieval quality.展开更多
We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microsco...We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging.展开更多
Return signal processing and reconstruction plays a pivotal role in coherent field imaging, having a significant in- fluence on the quality of the reconstructed image. To reduce the required samples and accelerate the...Return signal processing and reconstruction plays a pivotal role in coherent field imaging, having a significant in- fluence on the quality of the reconstructed image. To reduce the required samples and accelerate the sampling process, we propose a genuine sparse reconstruction scheme based on compressed sensing theory. By analyzing the sparsity of the received signal in the Fourier spectrum domain, we accomplish an effective random projection and then reconstruct the return signal from as little as 10% of traditional samples, finally acquiring the target image precisely. The results of the numerical simulations and practical experiments verify the correctness of the proposed method, providing an efficient processing approach for imaging fast-moving targets in the future.展开更多
Three-dimensional imaging with single orientation is a potential and novel technique. We successfully demonstrate that three-dimensional(3D) structure can be determined by a single orientation diffraction measuremen...Three-dimensional imaging with single orientation is a potential and novel technique. We successfully demonstrate that three-dimensional(3D) structure can be determined by a single orientation diffraction measurement for a phase object of double-layer Mie-scattering silica spheres on a Si3N4 membrane. Coherent diffraction pattern at high numerical aperture was acquired with an optical laser, and the oversampled pattern was projected from a planar detector onto the Ewald sphere.The double-layered spheres are reconstructed from the spherical diffraction pattern and a 2D curvature-corrected pattern,which improve convergence speed and stability of reconstruction.展开更多
AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was...AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.展开更多
AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal cr...AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance.展开更多
AIM:To describe the characteristics of peripapillary hyperreflective ovoid mass-like structure(PHOMS)in myopic children and to investigate factors associated with PHOMS.METHODS:This retrospective observational study i...AIM:To describe the characteristics of peripapillary hyperreflective ovoid mass-like structure(PHOMS)in myopic children and to investigate factors associated with PHOMS.METHODS:This retrospective observational study included 101 eyes of 101 children(age≤17y)with myopia.All included patients underwent comprehensive clinical examination.Optic nerve canal parameters,including disc diameter,optic nerve head(ONH)tilt angle,and border tissue angle were measured using serial enhanced-depth imaging spectral-domain optical coherence tomography(EDI-OCT).Based on the optic disc drusen consortium’s definition of PHOMS,eyes were classified as PHOMS group and non-PHOMS group.PHOMS was categorized according to height.RESULTS:Sixty-seven(66.3%)eyes were found with PHOMS.Small PHOMS could only be detected by optical coherence tomography(OCT).Medium PHOMS could be seen with blurred optic disc borders corresponding to OCT.The most frequent location of PHOMS was at the nasosuperior(91%,61 of 67 eyes)to ONH disc.The axial length and spherical equivalent were more myopic in the PHOMS group than in the non-PHOMS group(both P<0.001).ONH tilt angle was also significantly greater in PHOMS group than in non-PHOMS group[8.90(7.16-10.54)vs 3.93(3.09-5.25),P<0.001].Border tissue angle was significantly smaller in PHOMS group than in non-PHOMS group[29.70(20.90-43.81)vs 45.62(35.18-60.45),P<0.001].In the multivariable analysis,spherical equivalent(OR=3.246,95%CI=1.209-8.718,P=0.019)and ONH tilt angle(OR=3.275,95%CI=1.422-7.542,P=0.005)were significantly correlated with PHOMS.There was no disc diameter associated with PHOMS.In the linear regression analysis,border tissue angle was negatively associated with PHOMS height(β=-2.227,P<0.001).CONCLUSION:PHOMS is associated with optic disc tilt and optic disc nasal shift in myopia.Disc diameter is not a risk factor for PHOMS.The changes in ONH caused by axial elongation facilitated an understanding of the mechanism of PHOMS.展开更多
AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical c...AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.展开更多
An experimental measurement was performed us- ing time-resolved particle image velocimetry (TRPIV) to in- vestigate the spatial topological character of coherent struc- tures in wall-bounded turbulence of polymer ad...An experimental measurement was performed us- ing time-resolved particle image velocimetry (TRPIV) to in- vestigate the spatial topological character of coherent struc- tures in wall-bounded turbulence of polymer additive solu- tion. The fully developed near-wall turbulent flow fields with and without polymer additives at the same Reynolds number were measured by TRPIV in a water channel. The compar- isons of turbulent statistics confirm that due to viscoelastic structure of long-chain polymers, the wall-normal velocity fluctuation and Reynolds shear stress in the near-wall region are suppressed significantly. Furthermore, it is noted that such a behavior of polymers is closely related to the decease of the motion of the second and forth quadrants, i.e., the ejection and sweep events, in the near-wall region. The spa- tial topological mode of coherent structures during bursts has been extracted by the new mu-level criteria based on locally averaged velocity structure function. Although the general shapes of coherent structures are unchanged by polymer additives, the fluctuating velocity, velocity gradient, velocity strain rate and vorticity of coherent structures during burst events are suppressed in the polymer additive solution com- pared with that in water. The results show that due to the polymer additives the occurrence and intensity of coherent structures are suppressed, leading to drag reduction.展开更多
Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-insp...Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-inspired riblets on coherent vortex structures in a turbulent boundary layer(TBL) is investigated.This is done by means of tomographic particle image velocimetry(TPIV) measurements in channel fl ws over an acrylic plate of drag-reducing riblets at a friction Reynolds number of 190.The turbulent fl ws over drag-reducing riblets are verifie by a planar time-resolved particle image velocimetry(TRPIV) system initially,and then the TPIV measurements are performed.Two-dimensional(2D) experimental results with a dragreduction rate of around 4.81% are clearly visible over triangle riblets with a peak-to-peak spacing s+of 14,indicating from the drag-reducing performance that the buffer layer within the TBL has thickened;the logarithmic law region has shifted upward and the Reynolds shear stress decreased.A comparison of the spatial topological distributions of the spanwise vorticity of coherent vortex structures extracted at different wall-normal heights through the improved quadrant splitting method shows that riblets weaken the amplitudesof the spanwise vorticity when ejection(Q2) and sweep(Q4) events occur at the near wall,having the greatest effect on Q4 events in particular.The so-called quadrupole statistical model for coherent structures in the whole TBL is verified Meanwhile,their spatial conditional-averaged topological shapes and the spatial scales of quadrupole coherent vortex structures as a whole in the overlying turbulent fl w over riblets are changed,suggesting that the riblets dampen the momentum and energy exchange between the regions of near-wall and outer portion of the TBL by depressing the bursting events(Q2 and Q4),thereby reducing the skin friction drag.展开更多
AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT)...AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.展开更多
AIM: To predict the visual outcome in patients undergoing macular hole surgery by two novel three-dimensional morphological parameters on optical coherence tomography (OCT): area ratio factor (ARF) and volume ra...AIM: To predict the visual outcome in patients undergoing macular hole surgery by two novel three-dimensional morphological parameters on optical coherence tomography (OCT): area ratio factor (ARF) and volume ratio factor (VRF). METHODS: A clinical case series was conducted, including 54 eyes of 54 patients with an idiopathic macular hole (IMH). Each patient had an OCT examination before and after surgery. Morphological parameters of the macular hole, such as minimum diameter, base diameter, and height were measured. Then, the macular hole index (Mill), tractional hole index (THI), and hole form factor (HFF) were calculated. Meanwhile, novel postoperative macular hole (MH) factors, ARF and VRF were calculated by three-dimensional morphology. Bivariate correlations were performed to acquire asymptotic significance values between the steady best corrected visual acuity (BCVA) after surgery and 2D/3D arguments of MH by the Pearson method with two-tailed test. All significant factors were analyzed by the receiver operating characteristic (ROC) curve analysis of SPSS software which were responsible for vision recovery. ROC curves analyses were performed to further discuss the different parameters on the prediction of visual outcome. RESULTS: The mean and standard deviation values of patients' age, symptoms duration, and follow-up time were 64.8+8.9y (range: 28-81), 18.6+11.5d (range: 2-60), and 11.4+0.4mo (range: 6-24), respectively. Steady-post-BCVA analyzed with bivariate correlations was found to be significantly correlated with base diameter (r'0.521, P〈0.001), minimum diameter (r=0.514, P〈0.001), MHI (r -0.531, P〈0.001), THI (r=-0.386, P=-0.004), HFF (r=-0.508, P〈0.001), and ARF (r=-0.532, P〈0.001). Other characteristic parameters such as age, duration of surgery, height, diameter hole index, and VRF were not statistically significant with steady-post-BCVA. According to area under the curve (AUC) values, values of ARF, MHI, HFF, minimum diameter, THI, and base diameter are 0.806, 0.772, 0.750, 0.705, 0.690, and 0.686, respectively. However, Steady-post-BCVA analysis with bivariate correlations for VRF was no statistical significance. Results of ROC curve analysis indicated that the MHI value, HFF, and ARF was greater than 0.427, 1.027 and 1.558 respectively which could correlate with better visual acuity. CONCLUSION: Compared with MHI and HFF, ARF could effectively express three-dimensional characteristics of macular hole and achieve better sensitivity and specificity. Thus, ARF could be the most effective parameter to predict the visual outcome in macular hole surgery.展开更多
While ptychography is an algorithm based on coherent illumination,satisfactory reconstructions can still be generated in most experiments,even though the radiation sources that are used are not ideally coherent.The un...While ptychography is an algorithm based on coherent illumination,satisfactory reconstructions can still be generated in most experiments,even though the radiation sources that are used are not ideally coherent.The underlying physics of this phenomenon is that the diffraction patterns of partially coherent illumination can be treated as those of purely coherent illumination by altering the intensities of the diffracted beams relative to their real values.On the other hand,due to the inconsistency in the altering interference among all the diffraction beams,noise/distortion is always involved in the reconstructed images.Furthermore,for a weak object,the noise/distortion in the reconstruction can be mostly reduced by using a highly curved beam for illumination in the data recording and forcing the dark field diffraction to be zero in the reconstruction.展开更多
Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and contr...Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.展开更多
We propose and experimentally demonstrate a noniterative diffractive imaging method for reconstructing the complex-valued transmission function of an object illuminated by spatially partially coherent light from the f...We propose and experimentally demonstrate a noniterative diffractive imaging method for reconstructing the complex-valued transmission function of an object illuminated by spatially partially coherent light from the far-field diffraction pattern.Our method is based on a pinhole array mask,which is specially designed such that the correlation function in the mask plane can be obtained directly by inverse Fourier transforming the diffraction pattern.Compared to the traditional iterative diffractive imaging methods using spatially partially coherent illumination,our method is noniterative and robust to the degradation of the spatial coherence of the illumination.In addition to diffractive imaging,the proposed method can also be applied to spatial coherence property characterization,e.g.,free-space optical communication and optical coherence singularity measurement.展开更多
Based on anisotropic total variation regularization(ATVR), a nonnegativity and support constraints recursive inverse filtering(NAS-RIF) blind restoration method is proposed to enhance the quality of optical coherence ...Based on anisotropic total variation regularization(ATVR), a nonnegativity and support constraints recursive inverse filtering(NAS-RIF) blind restoration method is proposed to enhance the quality of optical coherence tomography(OCT) image. First, ATVR is introduced into the cost function of NAS-RIF to improve the noise robustness and retain the details in the image.Since the split Bregman iterative is used to optimize the ATVR based cost function, the ATVR based NAS-RIF blind restoration method is then constructed. Furthermore, combined with the geometric nonlinear diffusion filter and the Poisson-distribution-based minimum error thresholding, the ATVR based NAS-RIF blind restoration method is used to realize the blind OCT image restoration. The experimental results demonstrate that the ATVR based NAS-RIF blind restoration method can successfully retain the details in the OCT images. In addition, the signal-to-noise ratio of the blind restored OCT images can be improved, along with the noise robustness.展开更多
We report on the use of a fiber-based Mueller-matrix optical coherence tomography(OCT)system with continuous source-polarization modulation for in vivo imaging of early stages of skin cancer in SENCAR mice.A homemade ...We report on the use of a fiber-based Mueller-matrix optical coherence tomography(OCT)system with continuous source-polarization modulation for in vivo imaging of early stages of skin cancer in SENCAR mice.A homemade hand-held probe with integrated optical scanning and beam delivering optics was coupled in the sample arm.The OCT images show the morphological changes in skin resulting from pre-cancerous papilloma formations that are consistent with histology,thus demonstrating the system’s potential for early skin cancer detection.展开更多
A large field of view is in high demand for disease diagnosis in clinical applications of optical coherence tomography(OCT)and OCT angiography(OCTA)imaging.Due to limits on the optical scanning range,the scanning spee...A large field of view is in high demand for disease diagnosis in clinical applications of optical coherence tomography(OCT)and OCT angiography(OCTA)imaging.Due to limits on the optical scanning range,the scanning speed,or the data processing speed,only a relatively small region could be acquired and processed for most of the current clinical OCT systems at one time and could generate a mosaic image of multiple adjacent small-region images with registration algorithms for disease analysis.In this work,we investigated performing cross-correlation(instead of phase-correlation)in the workflow of the Fourier–Mellin transform(FMT)method(called dual-cross-correlation-based translation and rotation registration,DCCTRR)for calculating translation and orientation offsets and compared its performance to the FMT method used on OCTA images alignment.Both phantom and in vivo experiments were implemented for comparisons,and the results quantitatively demonstrate that DCCTRR can align OCTA images with a lower overlap rate,which could improve the scanning efficiency of large-scale imaging in clinical applications.展开更多
Lensless imaging is an approach to microscopy in which a high-resolution image of an object is reconstructed from one or more measured diffraction patterns,providing a solution in situations where the use of imaging o...Lensless imaging is an approach to microscopy in which a high-resolution image of an object is reconstructed from one or more measured diffraction patterns,providing a solution in situations where the use of imaging optics is not possible.However,current lensless imaging methods are typically limited by the need for a light source with a narrow,stable and accurately known spectrum.We have developed a general approach to lensless imaging without spectral bandwidth limitations or sample requirements.We use two time-delayed coherent light pulses and show that scanning the pulse-to-pulse time delay allows the reconstruction of diffraction-limited images for all the spectral components in the pulse.In addition,we introduce an iterative phase retrieval algorithm that uses these spectrally resolved Fresnel diffraction patterns to obtain high-resolution images of complex extended objects.We demonstrate this two-pulse imaging method with octave-spanning visible light sources,in both transmission and reflection geometries,and with broadband extreme-ultraviolet radiation from a high-harmonic generation source.Our approach enables effective use of low-flux ultra-broadband sources,such as table-top high-harmonic generation systems,for high-resolution imaging.展开更多
基金the Shanghai Soft X-ray Free-Electron Laser Facility beamline projectionfunded by the Major State Basic Research Development Program of China(No.2017YFA0504802)+1 种基金Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB 37040303)National Natural Science Foundation of China(No.21727817).
文摘The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstations covering a range of 100–620 eV for ultrafast X-ray science.Two undulator lines are designed and constructed,based on different lasing modes:self-amplified spontaneous emission and echo-enabled harmonic generation.The coherent scattering and imaging(CSI)endstation is the first of five endstations to be commissioned online.It focuses on high-resolution single-shot imaging and the study of ultrafast dynamic processes using coherent forward scattering techniques.Both the single-shot holograms and coherent diffraction patterns were recorded and reconstructed for nanoscale imaging,indicating the excellent coherence and high peak power of the SXFEL and the possibility of‘‘diffraction before destruction’’experiments at the CSI endstation.In this study,we report the first commissioning results of the CSI endstation.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11179009 and 50875013)the Beijing Municipal Natural Science Foundation, China (Grant No. 4102036)the Beijing NOVA Program, China (Grant No. 2009A09)
文摘Coherent diffractive imaging (CDI) is a lensless imaging technique and can achieve a resolution beyond the Rayleigh or Abbe limit. The ptychographical iterative engine (PIE) is a CDI phase retrieval algorithm that uses multiple diffraction patterns obtained through the scan of a localized illumination on the specimen, which has been demonstrated successfully at optical and X-ray wavelengths. In this paper, a general PIE algorithm (gPIE) is presented and demonstrated with an He-Ne laser light diffraction dataset. This algorithm not only permits the removal of the accurate model of the illumination function in PIE, but also provides improved convergence speed and retrieval quality.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11174019,61322509 and 11121091the National Basic Research Program of China under Grant No 2013CB921904
文摘We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging.
基金supported by the National Natural Science Foundation of China(Grant No.61505248)the Fund from Chinese Academy of Sciences,the Light of"Western"Talent Cultivation Plan"Dr.Western Fund Project"(Grant No.Y429621213)
文摘Return signal processing and reconstruction plays a pivotal role in coherent field imaging, having a significant in- fluence on the quality of the reconstructed image. To reduce the required samples and accelerate the sampling process, we propose a genuine sparse reconstruction scheme based on compressed sensing theory. By analyzing the sparsity of the received signal in the Fourier spectrum domain, we accomplish an effective random projection and then reconstruct the return signal from as little as 10% of traditional samples, finally acquiring the target image precisely. The results of the numerical simulations and practical experiments verify the correctness of the proposed method, providing an efficient processing approach for imaging fast-moving targets in the future.
基金Project supported by the Major State Basic Research Development Program of China(Grant No.2014CB910401)the National Natural Science Foundation of China(Grant Nos.31430031,21390414,and U1332118)
文摘Three-dimensional imaging with single orientation is a potential and novel technique. We successfully demonstrate that three-dimensional(3D) structure can be determined by a single orientation diffraction measurement for a phase object of double-layer Mie-scattering silica spheres on a Si3N4 membrane. Coherent diffraction pattern at high numerical aperture was acquired with an optical laser, and the oversampled pattern was projected from a planar detector onto the Ewald sphere.The double-layered spheres are reconstructed from the spherical diffraction pattern and a 2D curvature-corrected pattern,which improve convergence speed and stability of reconstruction.
基金Supported by National Natural Science Foundation of China(No.81300805)。
文摘AIM:To characterize spectral-domain optical coherence tomography(SD-OCT)features of chorioretinal folds in orbital mass imaged using enhanced depth imaging(EDI).METHODS:Prospective observational case-control study was conducted in 20 eyes of 20 patients,the uninvolved eye served as a control.All the patients underwent clinical fundus photography,computed tomography,EDI SDOCT imaging before and after surgery.Two patients with cavernous hemangiomas underwent intratumoral injection of bleomycin A5;the remaining patients underwent tumor excision.Patients were followed 1 to 14mo following surgery(average follow up,5.8mo).RESULTS:Visual acuity prior to surgery ranged from 20/20 to 20/200.Following surgery,5 patients’visual acuity remained unchanged while the remaining 15 patients had a mean letter improvement of 10(range 4 to 26 letters).Photoreceptor inner/outer segment defects were found in 10 of 15 patients prior to surgery.Following surgical excision,photoreceptor inner/outer segment defects fully resolved in 8 of these 10 patients.CONCLUSION:Persistence of photoreceptor inner/outer segment defects caused by compression of the globe by an orbital mass can be associated with reduced visual prognosis.Our findings suggest that photoreceptor inner/outer segment defects on EDI SD-OCT could be an indicator for immediate surgical excision of an orbital mass causing choroidal compression.
文摘AIM:To investigate changes in choroidal thickness and vascularity in keratoconus patients treated with corneal crosslinking.METHODS:This study evaluated 28 eyes of 22 patients with keratoconus who underwent corneal crosslinking.The choroidal thicknesses were evaluated on enhanced depth imaging optical coherence tomography at the preoperative and postoperative 3d,1,and 3mo.Choroidal thickness in the four cardinal quadrants and the fovea were evaluated.The choroidal vascularity index was also calculated.RESULTS:There was no significant difference in central choroidal thickness between the preoperative and postoperative 3d,1mo(P>0.05).There was a significant increase in the 3mo(P=0.034)and a significant decrease in the horizontal choroidal vascularity index on the postoperative 3d(P=0.014),there was no statistically significant change in vertical axes and other visits in horizontal sections(P>0.05).CONCLUSION:This study sheds light on choroidal changes in postoperative corneal crosslinking for keratoconus.While it suggests the procedure’s relative safety for submacular choroid,more extensive research is necessary to confirm these findings and their clinical significance.
基金Supported by Wuhan Central Hospital Discipline Fund(No.2021XK017).
文摘AIM:To describe the characteristics of peripapillary hyperreflective ovoid mass-like structure(PHOMS)in myopic children and to investigate factors associated with PHOMS.METHODS:This retrospective observational study included 101 eyes of 101 children(age≤17y)with myopia.All included patients underwent comprehensive clinical examination.Optic nerve canal parameters,including disc diameter,optic nerve head(ONH)tilt angle,and border tissue angle were measured using serial enhanced-depth imaging spectral-domain optical coherence tomography(EDI-OCT).Based on the optic disc drusen consortium’s definition of PHOMS,eyes were classified as PHOMS group and non-PHOMS group.PHOMS was categorized according to height.RESULTS:Sixty-seven(66.3%)eyes were found with PHOMS.Small PHOMS could only be detected by optical coherence tomography(OCT).Medium PHOMS could be seen with blurred optic disc borders corresponding to OCT.The most frequent location of PHOMS was at the nasosuperior(91%,61 of 67 eyes)to ONH disc.The axial length and spherical equivalent were more myopic in the PHOMS group than in the non-PHOMS group(both P<0.001).ONH tilt angle was also significantly greater in PHOMS group than in non-PHOMS group[8.90(7.16-10.54)vs 3.93(3.09-5.25),P<0.001].Border tissue angle was significantly smaller in PHOMS group than in non-PHOMS group[29.70(20.90-43.81)vs 45.62(35.18-60.45),P<0.001].In the multivariable analysis,spherical equivalent(OR=3.246,95%CI=1.209-8.718,P=0.019)and ONH tilt angle(OR=3.275,95%CI=1.422-7.542,P=0.005)were significantly correlated with PHOMS.There was no disc diameter associated with PHOMS.In the linear regression analysis,border tissue angle was negatively associated with PHOMS height(β=-2.227,P<0.001).CONCLUSION:PHOMS is associated with optic disc tilt and optic disc nasal shift in myopia.Disc diameter is not a risk factor for PHOMS.The changes in ONH caused by axial elongation facilitated an understanding of the mechanism of PHOMS.
基金Supported by Wenzhou Municipal Science and Technology Bureau(No.Y20150257)
文摘AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.
基金supported by the National Natural Science Foundation of China(11272233)National Key Basic Research and Development Program(2012CB720101)2012 opening subjects of The State Key Laboratory of Nonlinear Mechanics(LNM),Institute of Mechanics,Chinese Academy of Sciences
文摘An experimental measurement was performed us- ing time-resolved particle image velocimetry (TRPIV) to in- vestigate the spatial topological character of coherent struc- tures in wall-bounded turbulence of polymer additive solu- tion. The fully developed near-wall turbulent flow fields with and without polymer additives at the same Reynolds number were measured by TRPIV in a water channel. The compar- isons of turbulent statistics confirm that due to viscoelastic structure of long-chain polymers, the wall-normal velocity fluctuation and Reynolds shear stress in the near-wall region are suppressed significantly. Furthermore, it is noted that such a behavior of polymers is closely related to the decease of the motion of the second and forth quadrants, i.e., the ejection and sweep events, in the near-wall region. The spa- tial topological mode of coherent structures during bursts has been extracted by the new mu-level criteria based on locally averaged velocity structure function. Although the general shapes of coherent structures are unchanged by polymer additives, the fluctuating velocity, velocity gradient, velocity strain rate and vorticity of coherent structures during burst events are suppressed in the polymer additive solution com- pared with that in water. The results show that due to the polymer additives the occurrence and intensity of coherent structures are suppressed, leading to drag reduction.
基金supported by the National Natural Science Foundation of China (Grants 11332006,11272233,and 11411130150)the foundation from the China Scholarship Council (CSC) (Grant 201306250092)the Foundation Project for Outstanding Doctoral Dissertations of Tianjin University
文摘Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-inspired riblets on coherent vortex structures in a turbulent boundary layer(TBL) is investigated.This is done by means of tomographic particle image velocimetry(TPIV) measurements in channel fl ws over an acrylic plate of drag-reducing riblets at a friction Reynolds number of 190.The turbulent fl ws over drag-reducing riblets are verifie by a planar time-resolved particle image velocimetry(TRPIV) system initially,and then the TPIV measurements are performed.Two-dimensional(2D) experimental results with a dragreduction rate of around 4.81% are clearly visible over triangle riblets with a peak-to-peak spacing s+of 14,indicating from the drag-reducing performance that the buffer layer within the TBL has thickened;the logarithmic law region has shifted upward and the Reynolds shear stress decreased.A comparison of the spatial topological distributions of the spanwise vorticity of coherent vortex structures extracted at different wall-normal heights through the improved quadrant splitting method shows that riblets weaken the amplitudesof the spanwise vorticity when ejection(Q2) and sweep(Q4) events occur at the near wall,having the greatest effect on Q4 events in particular.The so-called quadrupole statistical model for coherent structures in the whole TBL is verified Meanwhile,their spatial conditional-averaged topological shapes and the spatial scales of quadrupole coherent vortex structures as a whole in the overlying turbulent fl w over riblets are changed,suggesting that the riblets dampen the momentum and energy exchange between the regions of near-wall and outer portion of the TBL by depressing the bursting events(Q2 and Q4),thereby reducing the skin friction drag.
基金Supported by Major Scientific and Technological Projects in Zhejiang Province,China(No.2013c03048-3)the Science and Technology Plan Project of Wenzhou Science and Technology Bureau(No.Y20150284)Medical Scientific Research Foundation of Zhejiang Province(No.2016ZDA016)
文摘AIM:To evaluate the peripapillary choroidal thickness(PPCT) in Chinese children,and to analyze the influencing factors.METHODS: PPCT was measured with enhanced depth imaging optical coherence tomography(EDI-OCT) in 70children(53 myopes and 17 non-myopes) aged 7 to 18 y,with spherical equivalent refractive errors between 0.50and-5.87 diopters(D).Peripapillary choroidal imaging was performed using circular scans of a diameter of 3.4 mm around the optic disc.PPCT was measured by EDI-OCT in six sectors: nasal(N),superonasal(SN),superotemporal(ST),temporal(T),inferotemporal(IT)and inferonasal(IN),as well as global RNFL thickness(G).RESULTS: The mean global PPCT was 165.49±33.76 μm.The temporal,inferonasal,inferotemporal PPCT were significantly thinner than the nasal,superonasal,superotemporal segments PPCT were significantly thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was significantly associated with the average global(β=-0.419,P =0.014),superonasal(β=-2.009,P=0.049) and inferonasal(β=-2.000,P=0.049) PPCT.The other factors(gender,age,SE) were not significantly associated with PPCT.CONCLUSION: PPCT was thinner in the myopic group at temporal,superotemporal and inferotemporal segments.The axial length was found to be negatively correlated to PPCT.We need more further studies about the relationship between PPCT and myopia.
基金Supported by National Natural Science Foundation of China(No.61675124No.81501559)+1 种基金Natural Science Foundation of the Higher Education Institutions of Jiangsu Province,China(No.15KJB310015)Science and Technology Foundation of Nantong Technology Bureau(No.MS12015180)
文摘AIM: To predict the visual outcome in patients undergoing macular hole surgery by two novel three-dimensional morphological parameters on optical coherence tomography (OCT): area ratio factor (ARF) and volume ratio factor (VRF). METHODS: A clinical case series was conducted, including 54 eyes of 54 patients with an idiopathic macular hole (IMH). Each patient had an OCT examination before and after surgery. Morphological parameters of the macular hole, such as minimum diameter, base diameter, and height were measured. Then, the macular hole index (Mill), tractional hole index (THI), and hole form factor (HFF) were calculated. Meanwhile, novel postoperative macular hole (MH) factors, ARF and VRF were calculated by three-dimensional morphology. Bivariate correlations were performed to acquire asymptotic significance values between the steady best corrected visual acuity (BCVA) after surgery and 2D/3D arguments of MH by the Pearson method with two-tailed test. All significant factors were analyzed by the receiver operating characteristic (ROC) curve analysis of SPSS software which were responsible for vision recovery. ROC curves analyses were performed to further discuss the different parameters on the prediction of visual outcome. RESULTS: The mean and standard deviation values of patients' age, symptoms duration, and follow-up time were 64.8+8.9y (range: 28-81), 18.6+11.5d (range: 2-60), and 11.4+0.4mo (range: 6-24), respectively. Steady-post-BCVA analyzed with bivariate correlations was found to be significantly correlated with base diameter (r'0.521, P〈0.001), minimum diameter (r=0.514, P〈0.001), MHI (r -0.531, P〈0.001), THI (r=-0.386, P=-0.004), HFF (r=-0.508, P〈0.001), and ARF (r=-0.532, P〈0.001). Other characteristic parameters such as age, duration of surgery, height, diameter hole index, and VRF were not statistically significant with steady-post-BCVA. According to area under the curve (AUC) values, values of ARF, MHI, HFF, minimum diameter, THI, and base diameter are 0.806, 0.772, 0.750, 0.705, 0.690, and 0.686, respectively. However, Steady-post-BCVA analysis with bivariate correlations for VRF was no statistical significance. Results of ROC curve analysis indicated that the MHI value, HFF, and ARF was greater than 0.427, 1.027 and 1.558 respectively which could correlate with better visual acuity. CONCLUSION: Compared with MHI and HFF, ARF could effectively express three-dimensional characteristics of macular hole and achieve better sensitivity and specificity. Thus, ARF could be the most effective parameter to predict the visual outcome in macular hole surgery.
基金supported by the Funds from the Engineering and Physical Sciences Research Council(Grant No.EP/E034055/1)the One Hundred Talent Project of the Chinese Academy of Sciences and the Financial Support(Grant No.GFZX0205010502.12)
文摘While ptychography is an algorithm based on coherent illumination,satisfactory reconstructions can still be generated in most experiments,even though the radiation sources that are used are not ideally coherent.The underlying physics of this phenomenon is that the diffraction patterns of partially coherent illumination can be treated as those of purely coherent illumination by altering the intensities of the diffracted beams relative to their real values.On the other hand,due to the inconsistency in the altering interference among all the diffraction beams,noise/distortion is always involved in the reconstructed images.Furthermore,for a weak object,the noise/distortion in the reconstruction can be mostly reduced by using a highly curved beam for illumination in the data recording and forcing the dark field diffraction to be zero in the reconstruction.
基金This work is funded by the Anhui Natural Science Foundation Project of China(under Grant KJ2016A201)the National Natural Science Foundation of China(under Grant 11774378).
文摘Outdoor power transformers are one of the most pervasive noise sources in power transmission and distribution systems.Accurate prediction of outdoor noise propagation plays a dominant role for the evaluation and control of noise relevant to the transformer stations.In this paper surface vibration tests are carried out on a scale model of a single-phase transformer tank wall at different excitation frequencies.The phase and amplitude of test data are found to be randomly distributed when the excitation frequency exceeds the seventh mode frequency,which allows the single-phase power transformer to be simplified as incoherent point sources.An outdoor-coherent model is subsequently developed and incorporated with the image source method to investigate noise propagation from single-phase power transformers,due to the occurrence of multiple reflections and diffractions in the propagation path of each point source.The proposed model is used to calculate the sound field of the power transformer group by exploiting the additional phase information.In comparison with the ISO9613 model and the boundary element method,it is found that the proposed coherent image source method leads to more accurate prediction results,and hence better performance for the prediction of the outdoor noise induced by single-phase power transformers.
基金This work was supported by the National Natural Science Foundation of China(Nos.11774250 , 91750201)the National Natural Science Fund for Distinguished Young Scholars(No.11525418)the sponsorship of Jiangsu Overseas Research and Training Program for Prominent Young and Middle-aged University Teachers and Presidents.This work is also part of the research program“Novel design shapes for complex optical systems,”with Project No.12797,which is(partly)financed by the Netherlands Organization for Scientific Research(NWO).
文摘We propose and experimentally demonstrate a noniterative diffractive imaging method for reconstructing the complex-valued transmission function of an object illuminated by spatially partially coherent light from the far-field diffraction pattern.Our method is based on a pinhole array mask,which is specially designed such that the correlation function in the mask plane can be obtained directly by inverse Fourier transforming the diffraction pattern.Compared to the traditional iterative diffractive imaging methods using spatially partially coherent illumination,our method is noniterative and robust to the degradation of the spatial coherence of the illumination.In addition to diffractive imaging,the proposed method can also be applied to spatial coherence property characterization,e.g.,free-space optical communication and optical coherence singularity measurement.
基金Supported by National Key Research and Development Program of China(2016YFF0201005)。
文摘Based on anisotropic total variation regularization(ATVR), a nonnegativity and support constraints recursive inverse filtering(NAS-RIF) blind restoration method is proposed to enhance the quality of optical coherence tomography(OCT) image. First, ATVR is introduced into the cost function of NAS-RIF to improve the noise robustness and retain the details in the image.Since the split Bregman iterative is used to optimize the ATVR based cost function, the ATVR based NAS-RIF blind restoration method is then constructed. Furthermore, combined with the geometric nonlinear diffusion filter and the Poisson-distribution-based minimum error thresholding, the ATVR based NAS-RIF blind restoration method is used to realize the blind OCT image restoration. The experimental results demonstrate that the ATVR based NAS-RIF blind restoration method can successfully retain the details in the OCT images. In addition, the signal-to-noise ratio of the blind restored OCT images can be improved, along with the noise robustness.
基金the Department of the Army(Cooperative Agreement Number:DAMD17-97-2-7016)the National Institutes of Health(R01 CA092415)。
文摘We report on the use of a fiber-based Mueller-matrix optical coherence tomography(OCT)system with continuous source-polarization modulation for in vivo imaging of early stages of skin cancer in SENCAR mice.A homemade hand-held probe with integrated optical scanning and beam delivering optics was coupled in the sample arm.The OCT images show the morphological changes in skin resulting from pre-cancerous papilloma formations that are consistent with histology,thus demonstrating the system’s potential for early skin cancer detection.
基金supported by the Natural Science Foundation of Jiangsu Province(No.BK20210227).
文摘A large field of view is in high demand for disease diagnosis in clinical applications of optical coherence tomography(OCT)and OCT angiography(OCTA)imaging.Due to limits on the optical scanning range,the scanning speed,or the data processing speed,only a relatively small region could be acquired and processed for most of the current clinical OCT systems at one time and could generate a mosaic image of multiple adjacent small-region images with registration algorithms for disease analysis.In this work,we investigated performing cross-correlation(instead of phase-correlation)in the workflow of the Fourier–Mellin transform(FMT)method(called dual-cross-correlation-based translation and rotation registration,DCCTRR)for calculating translation and orientation offsets and compared its performance to the FMT method used on OCTA images alignment.Both phantom and in vivo experiments were implemented for comparisons,and the results quantitatively demonstrate that DCCTRR can align OCTA images with a lower overlap rate,which could improve the scanning efficiency of large-scale imaging in clinical applications.
基金This work is financed in part by an NWO-groot investment grant of the Netherlands Organisation for Scientific Research(NWO)and Laserlab Europe(JRA Bioptichal)SW acknowledges support from NWO Veni grant 680-47-402.
文摘Lensless imaging is an approach to microscopy in which a high-resolution image of an object is reconstructed from one or more measured diffraction patterns,providing a solution in situations where the use of imaging optics is not possible.However,current lensless imaging methods are typically limited by the need for a light source with a narrow,stable and accurately known spectrum.We have developed a general approach to lensless imaging without spectral bandwidth limitations or sample requirements.We use two time-delayed coherent light pulses and show that scanning the pulse-to-pulse time delay allows the reconstruction of diffraction-limited images for all the spectral components in the pulse.In addition,we introduce an iterative phase retrieval algorithm that uses these spectrally resolved Fresnel diffraction patterns to obtain high-resolution images of complex extended objects.We demonstrate this two-pulse imaging method with octave-spanning visible light sources,in both transmission and reflection geometries,and with broadband extreme-ultraviolet radiation from a high-harmonic generation source.Our approach enables effective use of low-flux ultra-broadband sources,such as table-top high-harmonic generation systems,for high-resolution imaging.