期刊文献+
共找到1,563篇文章
< 1 2 79 >
每页显示 20 50 100
Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system
1
作者 Yaohui Wang Weimin Wang +3 位作者 Hui Liu Shunzhong Chen Feng Liu Qiuliang Wang 《Magnetic Resonance Letters》 2024年第1期1-9,共9页
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f... The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets. 展开更多
关键词 MRI Gradient coil Superconducting magnet Cryogen-free Magnetic shielding
下载PDF
Fuzzy Proportional Integral Derivative control of a voice coil actuator system for adaptive deformable mirrors
2
作者 Ziqiang Cui Heng Zuo +4 位作者 Weikang Qiao Hao Li Fujia Du Yifan Wang Jinrui Guo 《Astronomical Techniques and Instruments》 CSCD 2024年第3期179-186,共8页
Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number... Research on adaptive deformable mirror technology for voice coil actuators(VCAs)is an important trend in the development of large ground-based telescopes.A voice coil adaptive deformable mirror contains a large number of actuators,and there are problems with structural coupling and large temperature increases in their internal coils.Additionally,parameters of the traditional proportional integral derivative(PID)control cannot be adjusted in real-time to adapt to system changes.These problems can be addressed by introducing fuzzy control methods.A table lookup method is adopted to replace real-time calculations of the regular fuzzy controller during the control process,and a prototype platform has been established to verify the effectiveness and robustness of this process.Experimental tests compare the control performance of traditional and fuzzy proportional integral derivative(Fuzzy-PID)controllers,showing that,in system step response tests,the fuzzy control system reduces rise time by 20.25%,decreases overshoot by 78.24%,and shortens settling time by 67.59%.In disturbance rejection experiments,fuzzy control achieves a 46.09%reduction in the maximum deviation,indicating stronger robustness.The Fuzzy-PID controller,based on table lookup,outperforms the standard controller significantly,showing excellent potential for enhancing the dynamic performance and disturbance rejection capability of the voice coil motor actuator system. 展开更多
关键词 Adaptive optics Deformable mirror Voice coil actuator Fuzzy control
下载PDF
Design of Online Vision Detection System for Stator Winding Coil
3
作者 李艳 李芮 徐洋 《Journal of Donghua University(English Edition)》 CAS 2023年第6期639-648,共10页
The quality of the stator winding coil directly affects the performance of the motor.A dual-camera online machine vision detection method to detect whether the coil leads and winding regions were qualified was designe... The quality of the stator winding coil directly affects the performance of the motor.A dual-camera online machine vision detection method to detect whether the coil leads and winding regions were qualified was designed.A vision detection platform was designed to capture individual winding images,and an image processing algorithm was used for image pre-processing,template matching and positioning of the coil lead area to set up a coordinate system.After eliminating image noise by Blob analysis,the improved Canny algorithm was used to detect the location of the coil lead paint stripped region,and the time was reduced by about half compared to the Canny algorithm.The coil winding region was trained with the ShuffleNet V2-YOLOv5s model for the dataset,and the detect file was converted to the Open Neural Network Exchange(ONNX)model for the detection of winding cross features with an average accuracy of 99.0%.The software interface of the detection system was designed to perform qualified discrimination tests on the workpieces,and the detection data were recorded and statistically analyzed.The results showed that the stator winding coil qualified discrimination accuracy reached 96.2%,and the average detection time of a single workpiece was about 300 ms,while YOLOv5s took less than 30 ms. 展开更多
关键词 machine vision online detection V2-YOLOv5s model Canny algorithm stator winding coil
下载PDF
Analytical computation of magnetic field in coil-dominated superconducting quadrupole magnets based on racetrack coils
4
作者 Chuang Shen Ying-Shun Zhu Fu-San Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期119-135,共17页
Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufact... Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufacturing and strain-sensitive superconductor applications difficult.Compared with the three existing quadrupole coils,the racetrack quadrupole coil has a simple shape and manufacturing process,but there have been few theoretical studies.In this paper,the two-dimensional and three-dimensional analytical expressions for the magnetic field in coil-dominated racetrack superconducting quadrupole magnets are presented.The analytical expressions of the field harmonics and gradient are fully resolved and depend only on the geometric parameters of the coil and current density.Then,a genetic algorithm is applied to obtain a solution for the coil geometry parameters with field harmonics on the order of 10^(-4).Finally,considering the practical engineering needs of the accelerator interaction region,electromagnetic design examples of racetrack quadrupole magnets with high gradients,large apertures,and small apertures are described,and the application prospects of racetrack quadrupole coils are analyzed. 展开更多
关键词 Superconducting quadrupole magnet Racetrack coil Multipole field Genetic algorithm Magnetic design
下载PDF
Effect of coil and chamber structure on plasma radial uniformity in radio frequency inductively coupled plasma
5
作者 赵洋 周晓华 +2 位作者 高升荣 宋莎莎 赵玉真 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期58-66,共9页
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m... Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity. 展开更多
关键词 inductively coupled plasma fluid simulation optimized coil chamber aspect ratio plasma uniformity
下载PDF
Mathematical Modelling and Design of Helical Coil Heat Exchanger for Production of Hot Air for Fluidized Bed Dryer
6
作者 Iniubong James Uwa Uwem Ekwere Inyang Innocent Oseribho Oboh 《Advances in Chemical Engineering and Science》 CAS 2024年第3期125-136,共12页
In global industrialization, efforts have been made to increase the rate of heat transfer in heat exchanger, minimizing the size of heat exchanger to reduce cost as well as increasing the effectiveness. Helical coil h... In global industrialization, efforts have been made to increase the rate of heat transfer in heat exchanger, minimizing the size of heat exchanger to reduce cost as well as increasing the effectiveness. Helical coil heat exchanger (HCHE) has been proven to be effective in improving heat transfer due to its large surface area. In this study, HCHE was designed to provide hot air needed for fluidized bed drying processes. The HCHE design model was fabricated and evaluated to study the efficiency of the hot air output for a laboratory fluidized bed dryer. The mathematical model for estimation of the final (output) temperature of air, Taf, passing through the HCHE was developed and validated experimentally. The drying of bitter kola particulates was carried out with a drying temperature of 50C 3C and a bed height-to-bed diameter ratio (H/D) of 1.5. The time taken to dry bitter kola particulates to 0.4% moisture content was 1 hour 45 minutes. Hence, HCHE is recommended for use in the production of hot for laboratory-scale fluidized bed dryers. 展开更多
关键词 Helical coil Heat Exchanger Fluidized Bed Dryer Heat Transfer Output Air Temperature
下载PDF
Multi-objective optimization of gradient coil for benchtop magnetic resonance imaging system with high-resolution 被引量:1
7
作者 王龙庆 王为民 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期589-596,共8页
Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and... Significant high magnetic gradient field strength is essential to obtaining high-resolution images in a benchtop mag- netic resonance imaging (BT-MRI) system with permanent magnet. Extending minimum wire spacing and maximum wire width of gradient coils is one of the key solutions to minimize the maximum current density so as to reduce the local heating and generate higher magnetic field gradient strength. However, maximum current density is hard to optimize together with field linearity, stored magnetic energy, and power dissipation by the traditional target field method. In this paper, a new multi-objective method is proposed to optimize the maximum current density, field linearity, stored magnetic energy, and power dissipation in MRI gradient coils. The simulation and experimental results show that the minimum wire spacings are improved by 159% and 62% for the transverse and longitudinal gradient coil respectively. The maximum wire width increases from 0.5 mm to 1.5 mm. Maximum gradient field strengths of 157 mT/m and 405 mT/m for transverse and lon- gitudinal coil are achieved, respectively. The experimental results in BT-MRI instrument demonstrate that the MRI images with in-plane resolution of 50 ~tm can be obtained by using the designed coils. 展开更多
关键词 magnetic resonance imaging gradient coil target field method wire spacing
下载PDF
An efficient calibration method for SQUID measurement system using three orthogonal Helmholtz coils 被引量:1
8
作者 李华 张树林 +2 位作者 张朝祥 孔祥燕 谢晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期585-588,共4页
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ... For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately. 展开更多
关键词 SQUID MAGNETOMETER Tesla/volt coefficient calibration three-dimensional Helmholtz coil
下载PDF
A solids-free brine drilling fluid system for coiled tubing drilling 被引量:1
9
作者 WANG Xiaojun YU Jing +3 位作者 SUN Yunchao YANG Chao JIANG Lizhou LIU Chang 《Petroleum Exploration and Development》 2018年第3期529-535,共7页
There are many problems associated with coiled tubing drilling operations, such as great circulation pressure loss inside pipe, difficulties in weight on bit(WOB) transferring, and high probability of differential sti... There are many problems associated with coiled tubing drilling operations, such as great circulation pressure loss inside pipe, difficulties in weight on bit(WOB) transferring, and high probability of differential sticking. Aiming at these problems, solids-free brine drilling fluid system was developed on the basis of formulation optimization with brine base fluid experiment, which was evaluated and applied to field drilling. Based on the optimization of flow pattern regulator, salt-resisting filtrate reducer, high performance lubricant and bit cleaner, the basic formula of the solids-free brine drilling fluid system was formed: brine +(0.1%-0.2%) Na OH +(0.2%-0.4%) HT-XC +(2.0%-3.0%) YLJ-1 +(0.5%-2.0%) SDNR +(1.0%-2.5%) FT-1 A +(1.0%-5.0%) SD-505 + compound salt density regulator. Lab evaluation showed that the fluid had satisfactory temperature resistance(up to 150 ℃), excellent cuttings tolerance(up to 25%), and strong inhibition(92.7% cuttings recovery); Moreover, its lubrication performance was similar to that of all oil-based drilling fluid. The wellbore could be fairly cleaned at annular up-flow velocity of more than 0.8 m/s if the ratio of yield point to plastic viscosity was kept above 0.5. This fluid system has been applied in the drilling of three coiled tubing sidetracking wells in the Liaohe Oilfield, during which the system was stable and easy to adjust, resulting in excellent cuttings transportation, high ROP, regular hole size, and no down hole accidents. In summary, the solids-free brine drilling fluid system can meet the technical requirements of coiled tubing drilling. 展开更多
关键词 coiled tubing DRILLING BRINE DRILLING FLUID properties of DRILLING FLUID BOREHOLE stability Liaohe OILFIELD
下载PDF
Usefulness of the Guglielmi detachable coil for embolization of a systemic venous collateral after Fontan operation:A case report
10
作者 Tetsuo Sonomura Akira Ikoma +8 位作者 Nobuyuki Kawai Tomohiro Suenaga Takashi Takeuchi Hiroki Minamiguchi Shunji Uchita Motoki Nakai Hiroyuki Suzuki Kazushi Kishi Morio Sato 《World Journal of Radiology》 CAS 2012年第9期418-420,共3页
Embolization of collateral veins is often treated with rigid coils(Gianturco and interlocking detachable coils type).However,when dealing with tortuous and dilated collateral veins,there is a high risk for technical f... Embolization of collateral veins is often treated with rigid coils(Gianturco and interlocking detachable coils type).However,when dealing with tortuous and dilated collateral veins,there is a high risk for technical failure and coil migration due to inflexibility of the coils.To safely and successfully solve this problem,Guglielmi detachable coils(GDC) can be used for embolization.Their flexibility allows for easy navigation in tortuous veins,low risk of unintended coil release or coil migration,and safe deployment.A 12-year-old girl with a single ventricle had severe cyanosis and a low exercise tolerance 5 years after Fontan procedure.The symp-toms were caused by a tortuous and dilated collateral from the left phrenic vein into the left pulmonary vein,forming a right-to-left shunt.The collateral,which had a large diameter and high flow,and therefore a high risk of coil migration,was successfully embolized with 8 GDC.There were no complications such as coil migration or cerebral infarction.Transcatheter embolization increased her systemic oxygen saturation from 81%-84% to 94%-95%,and increased her ability to exercise.The embolization procedure using flexible GDC was low risk compared with other rigid coil embolization techniques when performing embolization of tortuous and dilated collateral veins. 展开更多
关键词 Pediatric intervention EMBOLIZATION systemIC VENOUS COLLATERAL FONTAN operation Guglielmi detachable coil
下载PDF
Transient multi-physics behavior of an insert high temperature superconducting no-insulation coil in hybrid superconducting magnets with inductive coupling 被引量:1
11
作者 Xiang KANG Yujin TONG +1 位作者 Wei WU Xingzhe WANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第2期255-272,共18页
A transient multi-physics model incorporated with an electromagneto-thermomechanical coupling is developed to capture the multi-field behavior of a single-pancake(SP)insert no-insulation(NI)coil in a hybrid magnet dur... A transient multi-physics model incorporated with an electromagneto-thermomechanical coupling is developed to capture the multi-field behavior of a single-pancake(SP)insert no-insulation(NI)coil in a hybrid magnet during the charging and discharging processes.The coupled problem is resolved by means of the finite element method(FEM)for the magneto-thermo-elastic behaviors and the Runge-Kutta method for the transient responses of the electrical circuits of the hybrid superconducting magnet system.The results reveal that the transient multi-physics responses of the insert NI coil primarily depend on the charging/discharging procedure of the hybrid magnet.Moreover,a reverse azimuthal current and a compressive hoop stress are induced in the insert NI coil during the charging process,while a forward azimuthal current and a tensile hoop stress are observed during the discharging process.The induced voltages in the insert NI coil can drive the currents flowing across the radial turns where the contact resistance exists.Therefore,it brings forth significant Joule heat,causing a temperature rise and a uniform distribution of this heat in the coil turns.Accordingly,a thermally/mechanically unstable or quenching event may be encountered when a high operating current is flowing in the insert NI coil.It is numerically predicted that a quick charging will induce a compressive hoop stress which may bring a risk of buckling instability in the coil,while a discharging will not.The simulations provide an insight of hybrid superconducting magnets under transient start-up or shutdown phases which are inevitably encountered in practical applications. 展开更多
关键词 hybrid superconducting magnet high temperature superconducting(HTS)no-insulation(NI)coil inductive coupling multi-physics field thermal stability
下载PDF
Parametric effect of large impulse current excited coil on electromagnetic force in coil-sheet system
12
作者 许威 方洪渊 +2 位作者 曹军 丁文斌 单平 《中国有色金属学会会刊:英文版》 CSCD 2009年第S3期806-810,共5页
Based on the method of controlling welding stress with trailing, the electromagnetic force in coil-sheet system was simulated with finite element software ANSYS. The effect of parameters of coil on the electromagnetic... Based on the method of controlling welding stress with trailing, the electromagnetic force in coil-sheet system was simulated with finite element software ANSYS. The effect of parameters of coil on the electromagnetic force density fy was analyzed. The results show that the maximum electromagnetic force density fy, max in sheet appears in the position near the inner radius of single-turn coil. The position is independent of section shape of coil. fy, max for flat coil is larger than that for long coil and the coil with wedge shape section, while section areas of all coils are equal to each other. The effect of turn number of multiple-turn coil on fy is dependent on the loop resistance in circuit. The kind of coil with more turns and larger inductance is commended while there is larger loop resistance in circuit. fy increases in a certain magnitude while a magnetic core is located in coil. However, the magnitude of fy is limited by saturating magnetic flux of the core. 展开更多
关键词 ELECTROMAGNETIC FORCE parameters of coil IMPULSE current SHEET
下载PDF
Integrated Design System of Toroidal Field Coil for CFETR
13
作者 罗志仁 刘旭峰 +2 位作者 杜双松 王忠伟 宋云涛 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第9期960-966,共7页
Integrating engineering software is meaningful but challenging for a system code of a fusion device. This issue is seldom considered by system codes currently. Therefore, to discuss the issue, the Integrated Design Sy... Integrating engineering software is meaningful but challenging for a system code of a fusion device. This issue is seldom considered by system codes currently. Therefore, to discuss the issue, the Integrated Design System of TF Coil (IDS-TFC) has been worked out, which consists of physical calculation, CAD, and Finite Element Analysis (FEA). Furthermore, an Integrated and Automatically Optimized Method (IAOM) has been created to address the integration and interfaces. The method utilizes a geometry parameter to connect each design submodule and achieve automatic optimization. Double-objectives optimization has been realized, confirming it is feasible to integrate and optimize engineering design and physical calculation. Moreover, IDS- TFC can also serve as a useful reference of integrated design processing for subsequent fusion design. 展开更多
关键词 IDS-TFC IAOM engineering software INTEGRATION TF coil
下载PDF
Performance Analysis of Multilayer Coil Based MI Waveguide Communication System
14
作者 Sandeep N.Dandu Vinay Kumar +1 位作者 Joydeep Sengupta Neeraj D.Bokde 《Computers, Materials & Continua》 SCIE EI 2022年第9期5287-5300,共14页
In the non-conventional media like underwater and underground,the Radio Frequency(RF)communication technique does not perform well due to large antenna size requirement and high path loss.In such media,magnetic induct... In the non-conventional media like underwater and underground,the Radio Frequency(RF)communication technique does not perform well due to large antenna size requirement and high path loss.In such media,magnetic induction(MI)communication technique is very promising due to small coil size and constant channel behavior.Unlike the RF technique,the communication range in MI technique is relatively less.To enhance this range,a waveguide technique is already brought in practice.This technique employs single layer coils to enhance the performance of MI waveguide.To further enhance the system functioning,in this paper,we investigated the performance of multi-layer coil(MLC)antenna based MI waveguide communication system in terms of transmission range,path loss,bit error rate(BER)and bandwidth.Besides,the system performance is quantitatively evaluated in three different non-conventional media viz.,dry soil,fresh water and wet soil.As compared with the single layer counterpart,the MLC system shows a significant improvement in transmission range,BER even in loosely coupled scenarios and shows a corresponding reduction in path loss.However,the bandwidth is observed to be low(<1 KHz).In this analysis,the eddy current effects and parasitic capacitance are compared for single and multilayer coils.It is observed that the proposed system performs better in dry soil medium due to less medium conductivity. 展开更多
关键词 Communication magnetic induction multilayer coil waveguide system
下载PDF
A novel radio frequency coil for veterinary magnetic resonance imaging system
15
作者 孟斌 黄开文 王为民 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期408-413,共6页
In this article, a novel designed radio frequency (RF) coil is designed and built for the imaging of puppies in a V-shape permanent magnetic resonance imaging (MRI) system. Two sets of Helmholtz coil pairs with a ... In this article, a novel designed radio frequency (RF) coil is designed and built for the imaging of puppies in a V-shape permanent magnetic resonance imaging (MRI) system. Two sets of Helmholtz coil pairs with a V-shape structure are used to improve the holding of an animal in the coil. The homogeneity and the sensitivity of the RF field in the coil are analysed by theoretical calculation. The size and the shape of the new coil are optimized and validated by simulation through using the finite element method (FEM). Good magnetic resonance (MR) images are achieved on a shepherd dog. 展开更多
关键词 veterinary magnetic resonance imaging (MRI) radio frequency (RF) coil homogeneity receiving sensitivity
下载PDF
Degree of style coiling is associated with corolla-tube length in the nectarless flowers of Roscoea schneideriana
16
作者 Bo Wang Ze-Yu Tong +3 位作者 Ying-Ze Xiong Xiao-Fan Wang W.Scott Armbruster Shuang-Quan Huang 《Plant Diversity》 SCIE CAS CSCD 2023年第6期748-751,共4页
The plant-pollinator‘arms race’model posits that a major driver of the evolution of elongated corollas in flowers is reciprocal selection for‘morphological fit’between pollinator-tongue length and access distance ... The plant-pollinator‘arms race’model posits that a major driver of the evolution of elongated corollas in flowers is reciprocal selection for‘morphological fit’between pollinator-tongue length and access distance to nectar(usually corolla-tube length).Evidence for the pollinator-mediated selection on tube length and evolution of multiple,correlated floral traits remains inconclusive.To gain possible insights into the strength of stabilizing selection by assessing standing phenotypic variation,we measured a series of functionally important floral traits,including corolla tube length and‘effective’tube depth and degree of style coiling.We then calculated coefficients of variation(CV)for these traits in three field populations of R.schneideriana.Unlike in most long-tubed flowers,the bottom part of the corolla tube is completely occupied by the style,with no room for nectar.The length of this portion of the corolla tube was more variable(higher CV)than the upper part of the corolla tube,suggesting that functional tube depth was under stronger stabilizing selection.The degree of style coiling was negatively related to the corolla-tube length in all three populations of R.schneideriana,suggesting that there may be conflicting selection acting on style length and corolla-tube length,which are otherwise usually tightly correlated.Given the lack of nectar in the flowers of this species,the long corolla tubes and long styles may represent morphological holdovers from ancestors that were pollinated by long-tongued pollinators,as is still seen in related species in the western Himalayas. 展开更多
关键词 Coefficient of variation coiled style Corolla-tube length Nectar depth Pollinator shift Trait covariation
下载PDF
Mechanical compression management of the right middle cerebral artery inferior trunk using a stent during coil embolization of middle cerebral artery aneurysms:A case report and literature review
17
作者 Zhengyu Wang Zhiqing Peng +2 位作者 Liang Chen Wanbin Li Yongli Wang 《Journal of Interventional Medicine》 2023年第3期126-129,共4页
Endovascular coil embolization is a minimally invasive,rapid,and effective method for the treatment of intracranial aneurysms.However,complications associated with coil embolization,such as intraoperative aneurysm rup... Endovascular coil embolization is a minimally invasive,rapid,and effective method for the treatment of intracranial aneurysms.However,complications associated with coil embolization,such as intraoperative aneurysm rupture or arterial occlusion,should be promptly managed during the procedure to avoid catastrophic consequences.This study presents a case of mechanical compression management of the right middle cerebral artery(MCA)inferior trunk during coil embolization for bilateral MCA aneurysms.The inferior trunk of the right MCA was abruptly occluded due to mechanical compression during coil embolization of the right MCA bifurcation aneurysm.A Solitaire AB stent(4×20 mm,Covidien/Medtronic,Dublin,Ireland)was implanted in the inferior trunk of the right MCA after tirofiban was injected via a microcatheter,and the right inferior trunk was recanalized.The patient also underwent coil embolization of the left MCA bifurcation aneurysm,without any complications.It is crucial to recognize compressive occlusion of adjacent aneurysm branches to avoid severe complications during intracranial aneurysm embolization.Stent placement is a rescue treatment option for recanalization of an occluded artery. 展开更多
关键词 Endovascular coil embolization Intracranial aneurysm Mechanical compression STENT
下载PDF
Stent-assisted coiling of intracranial carotid ophthalmic segment aneurysm segment aneurysms:Long-term follow-up from a single center
18
作者 Wenquan Gu Geng Zhou +10 位作者 Aizada Aldiyarova Tengyue Liu Yi Zhang Weidong Liu Lingping Meng Binxian Gu MingHua Li Ming Su Chen Su Aihua Liu Wu Wang 《Journal of Interventional Medicine》 2023年第3期116-120,共5页
Background:To evaluate the efficacy of stent-assisted coiling(SAC)for the treatment of carotid ophthalmic segment aneurysm segment aneurysms(OSAs)of the internal carotid artery(ICA)through detailed long-term follow-up... Background:To evaluate the efficacy of stent-assisted coiling(SAC)for the treatment of carotid ophthalmic segment aneurysm segment aneurysms(OSAs)of the internal carotid artery(ICA)through detailed long-term follow-up of a large patient cohort.Methods:We retrospectively analyzed 88 consecutive patients with OSAs between January 2009 and January 2020 at our center.Angiographic results were evaluated using the modified Raymond grading system and clinical outcomes were evaluated using the mRS scale.The primary endpoints were major aneurysm recurrence and poor clinical outcomes for at least 18 months of follow-up.The patients were asked to attend clinical follow-up assessments and possibly undergo DSA or MR via telephone.Results:We enrolled 88 patients with 99 OSAs treated with coiling,of whom 76 were treated with SAC.The coiling procedures were successful in all 88 patients.Overall,complications occurred in 8 patients(9.1%).No procedure-related mortality was observed.67(76.1%)experienced immediate aneurysm occlusion at the end of the procedure.Long-term angiographic follow-up(18 months)was available in 45/88 aneurysms(51%)(average 18.7±5.2 months).Four patients continued their follow-up for 5 years after initial aneurysm treatment.After a clinical follow-up time of 28.7 months(range,12-51 months),85 patients(95.5%)achieved favorable clinical outcomes(mRS scores of 0-2).Conclusions:This study indicates that SAC treatment is a safe and effective therapeutic alternative for ruptured and unruptured OSAs.The procedural risks are low with relatively long-term effectiveness. 展开更多
关键词 Endovascular treatment Stent-assisted coiling C6 segment aneurysm Occlusion rate Long-term follow-up
下载PDF
Design of new resonant magnetic perturbation coils on the J-TEXT tokamak
19
作者 黄卓 周松 +11 位作者 樊金荣 李达 饶波 王能超 丁永华 毛飞越 黄名响 田微 陈忠勇 陈志鹏 梁云峰 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第11期142-149,共8页
The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to... The resonant magnetic perturbation(RMP)system is a powerful auxiliary system on tokamaks.On the J-TEXT tokamak,a set of new in-vessel coils is designed to enhance the amplitude of the RMP.The new coils are designed to be two-turn saddle coils.These two-turn saddle coils have been optimized in terms of their structure,support,and protection components to overcome the limitations of the narrow in-vessel space,resulting in a compact coil module that can be accommodated in the vessel.To verify the feasibility of this design,an electromagnetic simulation is performed to investigate the electrical parameters and the generated field of the coils.A multi-field coupled simulation is performed to investigate the capacity of heat dissipation.As a result of these efforts,the new RMP coils have been successfully installed on the J-TEXT tokamak.It has significantly enhanced the RMP amplitude and been widely applied in experiments. 展开更多
关键词 fusion engineering TOKAMAK resonant magnetic perturbation coil multi-field coupled simulation(Some fioures may appeari in colour only in the online iournal)
下载PDF
Accurate surface normal representation to facilitate gradient coil optimization on curved surface
20
作者 Hao Ren Hui Pan +2 位作者 Feng Jia Jan G.Korvink Zhenyu Liu 《Magnetic Resonance Letters》 2023年第1期67-84,I0004,共19页
The design methods for gradient coils are mostly based on discrete extrinsic methods(e.g.,the BioteSavart integration calculation),for which the surface normal vector strongly influences any numerical calculation of t... The design methods for gradient coils are mostly based on discrete extrinsic methods(e.g.,the BioteSavart integration calculation),for which the surface normal vector strongly influences any numerical calculation of the discretized surface.Previous studies are mostly based on regular or analytical surfaces,which allow normal vectors to be expressed analytically.For certain applications,design methods for extending currentcarrying surfaces from developable or analytic geometries to arbitrary surfaces generated from a scanned point cloud are required.The key task is to correctly express the discretized normal vectors to ensure geometrical accuracy of the designed coils.Mathematically,it has been proven that applying a Delaunay triangulation to approximate a smooth surface can result in the discrete elemental normal vectors converging to those of the original surface.Accordingly,this article uses Delaunay triangulation to expand upon previous design methods so that they encompass arbitrary piecewise continuous surfaces.Two design methods,the stream function and the so-called solid isotropic material with penalization(SIMP)method,are used to design circumvolute and noncircumvolute gradient coils on general surfaces. 展开更多
关键词 Gradient coils Delaunay triangulation Stream function SIMP method
下载PDF
上一页 1 2 79 下一页 到第
使用帮助 返回顶部