Based on analyzing the thermal process of a CDQ (coke dry quenching)-Boiler system, the mathematical model for opti-mized operation and control in the CDQ-Boiler system was developed. It includes a mathematical mode...Based on analyzing the thermal process of a CDQ (coke dry quenching)-Boiler system, the mathematical model for opti-mized operation and control in the CDQ-Boiler system was developed. It includes a mathematical model for heat transferring process in the CDQ unit, a mathematical model for heat transferring process in the boiler and a combustion model for circulating gas in the CDQ-Boiler system. The model was verified by field data, then a series of simulations under several typical operating conditions of CDQ-Boiler were carried on, and in turn, the online relation formulas between the productivity and the optimal circulating gas, and the one between the productivity and the optimal second air, were achieved respectively. These relation equations have been success- fully used in a CDQ-Boiler computer control system in the Baosteel, to realize online optimized guide and control, and meanwhile high efficiency in the CDQ-Boiler system has been achieved.展开更多
Based on the detailed analysis of the third coke oven in BaoSteel, a feedbackcontrol strategy of longitudinal temperature and finished carbonization time of coke ovens wasproposed and it was applied to the third coke ...Based on the detailed analysis of the third coke oven in BaoSteel, a feedbackcontrol strategy of longitudinal temperature and finished carbonization time of coke ovens wasproposed and it was applied to the third coke oven in BaoSteel. As a result, the ratio of theinstance that the absolute deviation of the longitudinal temperature is within +- 7 deg C and thefinished carbonization time within +- 10 min is more than 80 percent, having acquired the patentsaving effect of an energy consumption lowered by 2.92 percent. At the same time, it can provide anexample for the same coke ovens inside and outside the nation.展开更多
文摘Based on analyzing the thermal process of a CDQ (coke dry quenching)-Boiler system, the mathematical model for opti-mized operation and control in the CDQ-Boiler system was developed. It includes a mathematical model for heat transferring process in the CDQ unit, a mathematical model for heat transferring process in the boiler and a combustion model for circulating gas in the CDQ-Boiler system. The model was verified by field data, then a series of simulations under several typical operating conditions of CDQ-Boiler were carried on, and in turn, the online relation formulas between the productivity and the optimal circulating gas, and the one between the productivity and the optimal second air, were achieved respectively. These relation equations have been success- fully used in a CDQ-Boiler computer control system in the Baosteel, to realize online optimized guide and control, and meanwhile high efficiency in the CDQ-Boiler system has been achieved.
文摘Based on the detailed analysis of the third coke oven in BaoSteel, a feedbackcontrol strategy of longitudinal temperature and finished carbonization time of coke ovens wasproposed and it was applied to the third coke oven in BaoSteel. As a result, the ratio of theinstance that the absolute deviation of the longitudinal temperature is within +- 7 deg C and thefinished carbonization time within +- 10 min is more than 80 percent, having acquired the patentsaving effect of an energy consumption lowered by 2.92 percent. At the same time, it can provide anexample for the same coke ovens inside and outside the nation.