The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu...The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.展开更多
In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The res...In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The results showed that the fight hepatic lobe could be scanned through the right carotid anterior acoustic win- dow, and the left hepatic lobe could be scanned through the left carotid anterior acoustic window, but the vision would be obstructed by the air in trachea. The liver could also be scanned through the left femoral anterior acoustic window and the fight femoral anterior acoustic window when filling of bladder was good. The correla- tion regression analysis suggested that estimated values of liver showed no linear relationship with weight, the longest back curve and the widest back curve. Through the study, the normal indicators for ultrasound examination of red-eared turtle liver were established, in order to provide a reference for examination of turtle liver.展开更多
Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the...Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the anterior, middle and posterior cerebral arteries were studied. The results showed evidently lower systolic amplitude in patients than that in normal subjects. End diastolic amplitude was zero in part of vessels, and values of bloed flow variables were all lower in day 1 of the life as compared with the control groups. Frequency spectrum recovered to normal patterns in 9 survived infants in day 2. but blood flow variables recovered to normal by day 7. Values of resistance index (RI) rose to 1 in some vessels of moderate hypoxic ischemic encephalopathy (HIE) infants and stayed at 1 in the severe HIE infants. It is concluded that low CBF plays a key role in brain damage of post-asphyxiated newborns and RI may be an important parameter in the evaluation prognosis.展开更多
文摘The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.
文摘In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The results showed that the fight hepatic lobe could be scanned through the right carotid anterior acoustic win- dow, and the left hepatic lobe could be scanned through the left carotid anterior acoustic window, but the vision would be obstructed by the air in trachea. The liver could also be scanned through the left femoral anterior acoustic window and the fight femoral anterior acoustic window when filling of bladder was good. The correla- tion regression analysis suggested that estimated values of liver showed no linear relationship with weight, the longest back curve and the widest back curve. Through the study, the normal indicators for ultrasound examination of red-eared turtle liver were established, in order to provide a reference for examination of turtle liver.
文摘Cerebral blood flow of 10 asphyxiated term newborns was continuously measured during the first 7 days of life and compared with that of 10 normal term infants by CDI. Frequency spectrum and blood flow variables in the anterior, middle and posterior cerebral arteries were studied. The results showed evidently lower systolic amplitude in patients than that in normal subjects. End diastolic amplitude was zero in part of vessels, and values of bloed flow variables were all lower in day 1 of the life as compared with the control groups. Frequency spectrum recovered to normal patterns in 9 survived infants in day 2. but blood flow variables recovered to normal by day 7. Values of resistance index (RI) rose to 1 in some vessels of moderate hypoxic ischemic encephalopathy (HIE) infants and stayed at 1 in the severe HIE infants. It is concluded that low CBF plays a key role in brain damage of post-asphyxiated newborns and RI may be an important parameter in the evaluation prognosis.