期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Control Effects of Bacillus subtilis DJ-6 and Pyraclostrobin Alone and in Combination Against Fusarium oxysporum 被引量:9
1
作者 吉沐祥 姚克兵 +3 位作者 李国平 吴祥 陈宏洲 庄义庆 《Agricultural Science & Technology》 CAS 2014年第11期2020-2025,共6页
[Objective] This study was conducted to screen a synergistic biological fungicide complex to control Fusarium wilt, reducing the use of chemical pesticides. [Method] The inhibitory effects of Bacil us subtilis DJ-6 an... [Objective] This study was conducted to screen a synergistic biological fungicide complex to control Fusarium wilt, reducing the use of chemical pesticides. [Method] The inhibitory effects of Bacil us subtilis DJ-6 and pyraclostrobin alone or in combination at five ratios against Fusarium oxysporum were detected by mea-suring mycelium growth rate in laboratory tests. The growth promotion and disease control effect of combined or single use of 20% pyraclostrobin and 2 ×1011 cfu/g B. subtilis DJ-6 WP at 1∶1 000, 1∶2 000 and 1∶3 000 dilutions were detected in field trials. [Result] The EC50 values of combined use of B. subtilis DJ-6 and pyra-clostrobin at ratios of 1∶1, 1∶2, 1∶3, 1∶4 and 1∶5 against F. oxysporum were 5.311 5, 4.008 6, 3.570 6, 3.350 9 and 3.218 9 μg/ml, with the synergistic ratios (SR) of 2.28, 1.77, 1.53, 1.64, 1.11, among which the synergetic effect at 1∶1 was the best. The fungicidal activity of pyraclostrobin was greater than that of B. subtilis DJ-6 in laboratory tests. Field trials revealed that al the 1∶1 000, 1∶2 000 and 1∶3 000 dilu-tions of 20% pyraclostrobin·2×1011 cfu/g B. subtilis DJ-6 WP in combination, 1∶1 000 dilution of 1 ×1012 cfu/g B. subtilis DJ-6 WP and 1∶2 000 dilution of 250 g/L pyra-clostrobin EC promoted the growth of strawberry by increasing plant height, leaf petiole, leaf blade area and stem diameter. Among them, the treatments with 1∶1 000 and 1∶2 000 of 20% pyraclostrobin · 2×1011 cfu/g B. subtilis DJ-6 WP in combina-tion had better effects than other treatments. The control effects of al the treat-ments were measured 30 and 80 d after fungicide application. The control effects of 1∶1 000 dilution of 20% pyraclostrobin and 2×1011 cfu/g B. subtilis DJ-6 in combina-tion were up to 100% and 93.11%, which were higher than those in al other treat-ments. The second highest control effects were found in the treatment with 1∶ 2 000 dilution of 20% pyraclostrobin and 2×1011 cfu/g B. subtilis DJ-6 in combination, they were 92.49% and 86.49%, higher than those in other treatments except the 1∶1 000 dilution of 20% pyraclostrobin and 2 ×1011 cfu/g B. subtilis DJ-6 in combination. The control effects of 1∶3 000 dilution of 20% pyraclostrobin and 2×1011 cfu/g B. subtilis DJ-6 in combination were 82.61% and 72.42%, higher than those in treatment with 1∶1 000 dilution of 1×1012 cfu/g B. subtilis DJ-6 WP, but lower than those in treat-ment with 1∶2 000 dilution of 25% pyraclostrobin EC. [Conclusion] Al the results re-vealed that the combination use of 20% pyraclostrobin and 2 ×1011 cfu/g B. subtilis DJ-6 WP at 1∶1 000 to 1∶2 000 dilution had better control effect against strawberry Fusarium wilt. 展开更多
关键词 Strawberry Fusarium wilt Bacil us subtilis DJ-6 Pyraclostrobin Use in combination Antibacterial activity Plant growth traits Field control effects
下载PDF
On units combination and commitment optimization for electric power production 被引量:1
2
作者 谭忠富 何永秀 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2004年第1期12-18,共7页
Electric power system is one of the most important and complex engineering in modern society, supplying main and general power for social production and social life. Meanwhile, since it is a productive system with bo... Electric power system is one of the most important and complex engineering in modern society, supplying main and general power for social production and social life. Meanwhile, since it is a productive system with both high input and output, it has an obvious economic significance to improve its operating efficiency. For an example, an unit is 10 GW scale, if its standard coal consumption can be decreased with 1 g/kW·h, it can save about 5 000 tons standard coal per year. It will be discussed mainly that how to establish optimization model and its numerical algorithm for operating management of the electric power system. The idea on establishing optimization model is how to dispatch work state of units or power plants, so that total cost of fuel consumption for generation is reduced to the minimum. Here the dispatch is to decide which unit or plant to operate, which unit or plant to stop running, how much power should be generated for those operating units or plants at each given time interval. 展开更多
关键词 units combination units commitment OPTIMIZATION plants combination interconnection system
下载PDF
Assessment of the thermal effect of large industrial buildings on permafrost foundation soils in Yakutsk
3
作者 Rudolf V.Zhang Stanislav I.Zabolotnik Pavel S.Zabolotnik 《Research in Cold and Arid Regions》 CSCD 2023年第6期262-267,共6页
The results of monitoring studies of the ground thermal state beneath the Yakutsk Combined Heat and Power Plant buildings are presented in order to determine their structural stability and the possibility of further t... The results of monitoring studies of the ground thermal state beneath the Yakutsk Combined Heat and Power Plant buildings are presented in order to determine their structural stability and the possibility of further troublefree operation of the entire complex of the structures.The main causes for the formation of water-bearing taliks under and adjacent to the buildings are presented,and the factors influencing the existing geocryological situation are discussed.The continuing stable state of the buildings demonstrates the possibility of using two construction principles on permafrost at one site,including preserving permafrost and accommodating permafrost thawing. 展开更多
关键词 Yakutsk Combined Heat and Power Plant PERMAFROST Talik Ground temperature
下载PDF
Selection of Indigenous Plants in Roads in Northwestern Loess Plateau Area
4
作者 张铁军 王春玲 《Agricultural Science & Technology》 CAS 2012年第3期583-591,共9页
[Objective] The aim was to study on resource utilization of indigenous plants in roads in order to solve resource shortage of indigenous plant in bioengi- neering. [Method] Based on northwestern loess plateau area, we... [Objective] The aim was to study on resource utilization of indigenous plants in roads in order to solve resource shortage of indigenous plant in bioengi- neering. [Method] Based on northwestern loess plateau area, we conducted research on selection of indigenous plants and survey on the species which could live in adverse condition, mainly by surveying, with frequent tests as a supplement, to make a comprehensive observation and evaluation on plant combinations which are to be extensively applied. [Result] The research indicated that in central dividing strips, four arbors, including Platycladus orientalis (Linn.)Franco, Sabina chinensis, Sabinachinen- sis(Linn.)Ant., and Ulmus purnila L., and nine frutices, including Lycium chinense, Tamarix austromongolica, Rosa xanthina Lindl., Forsythia suspense, Atriplex canescens, Amygdalus triloba, Hippophae rharnnoides Linn., Arnorpha fruticosa L., and Syzygium aromaticum could be planted. In addition, Gleditsia sinensis Lain, Robinia pseudoacacia L, Elaeagnus angustifolia L., Rhus typhina, Salix babylonica, Salixmatsudana and Fraxinus chinensis, tall and strong, are suitable to be planted as border trees, presenting a good vision. Frutices, limited by height, are usually with more branches, which will provide a good landscape if grown with tall plants. Prunus dacidiana and Ulmus pumila L., prone to be damaged by insects, should be planted with other species to stop the infestation in space. [Conclusion] The research laid foundation for selection of indigenous plants in roads, providing references for resource shortage of indigenous plant for bioengineedng. 展开更多
关键词 Loess Plateau area ROAD Indigenous plant SELECTION Plant combination
下载PDF
Model Selection of Gas Turbine for Large Scale Gas-Fired Combined Cycle Power Plant
5
作者 何语平 《Electricity》 2003年第4期36-39,共4页
This paper briefs the configuration and performance of large size gas turbines and their composed combined cycle power plants designed and produced by four large renown gas turbine manufacturing firms in the world, pr... This paper briefs the configuration and performance of large size gas turbines and their composed combined cycle power plants designed and produced by four large renown gas turbine manufacturing firms in the world, providing reference for the relevant sectors and enterprises in importing advanced gas turbines and technologies. 展开更多
关键词 natural gas combined cycle power plant unit model selection
下载PDF
Design of multi-module experiment-rig of vessel electrical propulsion prime mover
6
作者 XIEChun-ling WANGYuan-hui 《Journal of Marine Science and Application》 2005年第1期26-29,共4页
Combined power plant is widely used in large or medium surface vessel for its predominant performance. It is important to research on using combined power plant as electrical propulsion prime mover for developing the ... Combined power plant is widely used in large or medium surface vessel for its predominant performance. It is important to research on using combined power plant as electrical propulsion prime mover for developing the electric propulsion warship.This paper, designs a multi-module experiment-rig and introduces its composition, working principle and disposition scheme,and carried out the dynamic characteristic experiment of the GTD350 gas turbine. 展开更多
关键词 electrical propulsion modular composition combined power plant
下载PDF
The ecosystem of Lake Kenon:past and present(Transbaikal Territory,Russia)
7
作者 Alexey P.KUKLIN Gazhit Ts.TSYBEKMITOVA +2 位作者 Evgenia P.GORLACHEVA Balzhit B.BAZAROVA Alexey V.AFONIN 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2016年第3期507-516,共10页
Present-day conditions of the Lake Kenon ecosystem are determined by a combination of natural and anthropogenic factors. We have estimated the effects of a complex of factors on the condition of the abiotic environmen... Present-day conditions of the Lake Kenon ecosystem are determined by a combination of natural and anthropogenic factors. We have estimated the effects of a complex of factors on the condition of the abiotic environment and on specific biological components in the lake ecosystem. Change in biogenic load has caused an increase in the role of phytoplankton in the general balance of organic matter during the high-water period. Charophytes are the main dominants of bottom vegetation. Anthropogenic load has caused a decrease in both fish species and fish capacity. The lake application as a water reservoir-cooler has influenced the average annual water mineralization (from 420 mg/L to 530.0 mg/L with a maximum 654 mg/L in 1993) and fluctuations in its hydrochemical composition. The present composition of the lake is sulfate-hydrocarbonate-chloride calcium-sodic-magnesium in character. S(Y44 content is twice as much as the maximum permissible concentration in fishery waters. Water drainage from an ash disposal area to the lake has caused an increase in chemical-element concentrations including the heavy metals. Hg concentration in Perca fluviatilis muscles is 0.5 9g/g dry wt. Thus, understanding directions in the ecosystem of the water reservoir-cooler under changing hydrological conditions will let us forecast the consequences of new combined heat and power plant operation. 展开更多
关键词 water reservoir-cooler of combined heat and power plant (CHP) HYDROCHEMISTRY ICHTHYOFAUNA BIODIVERSITY the chemical elements
下载PDF
Compensating active power imbalances in power system with large-scale wind power penetration 被引量:10
8
作者 Abdul BASIT Anca D.HANSEN +2 位作者 Mufit ALTIN Poul E.SØRENSEN Mette GAMST 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第2期229-237,共9页
Large-scale wind power penetration can affect the supply continuity in the power system.This is a matter of high priority to investigate,as more regulating reserves and specified control strategies for generation cont... Large-scale wind power penetration can affect the supply continuity in the power system.This is a matter of high priority to investigate,as more regulating reserves and specified control strategies for generation control are required in the future power system with even more high wind power penetration.This paper evaluates the impact of large-scale wind power integration on future power systems.An active power balance control methodology is used for compensating the power imbalances between the demand and the generation in real time,caused by wind power forecast errors.The methodology for the balance power control of future power systems with large-scale wind power integration is described and exemplified considering the generation and power exchange capacities in2020 for Danish power system. 展开更多
关键词 Wind power plant SIMBA Centralized or decentralized combined heat and power plant Automatic generation control
原文传递
Low-carbon Operation of Combined Heat and Power Integrated Plants Based on Solar-assisted Carbon Capture 被引量:15
9
作者 Xusheng Guo Suhua Lou +1 位作者 Yaowu Wu Yongcan Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第5期1138-1151,共14页
Accelerating the development of renewable energy and reducing CO_(2)emissions have become a general consensus and concerted action of all countries in the world. The electric power industry, especially thermal power i... Accelerating the development of renewable energy and reducing CO_(2)emissions have become a general consensus and concerted action of all countries in the world. The electric power industry, especially thermal power industry, is the main source for fossil energy consumption and CO_(2)emissions. Since solvent-based post-combustion carbon capture technology would bring massive extra energy consumption, the application of solar-assisted carbon capture technology has attracted extensive attention. Due to the important role of coal-fired combined heat and power plants for serving residential and industrial heating districts, in this paper, the low-carbon operation benefits of combined heat and power integrated plants based on solar-assisted carbon capture(CHPIP-SACC) are fully evaluated in heat and power integrated energy system with a high proportion of wind power. Based on the selected integration scheme, a linear operation model of CHPIP-SACC is developed considering energy flow characteristics and thermal coupling interaction of its internal modules. From the perspective of system-level operation optimization, the day-ahead economic dispatch problem based on a mix-integer linear programming model is presented to evaluate the low-carbon benefits of CHPIP-SACC during annual operation simulation. The numerical simulations on a modified IEEE 39-bus system demonstrate the effectiveness of CHPIP-SACC for reducing CO_(2)emissions as well as increasing the downward flexibility. The impact of different solar field areas and unit prices of coal on the low-carbon operation benefits of CHPIP-SACC is studied in the section of sensitivity analysis. 展开更多
关键词 Solar-assisted carbon capture CO_(2)emission reduction combined heat and power integrated plant heat and power integrated energy system wind power
原文传递
Performance Improvement of Combined Cycle Power Plant Based on the Optimization of the Bottom Cycle and Heat Recuperation 被引量:3
10
作者 Wenguo XIANG Yingying CHEN 《Journal of Thermal Science》 SCIE EI CAS CSCD 2007年第1期84-89,共6页
Many F class gas turbine combined cycle (GTCC) power plants are built in China at present because of less emission and high efficiency. It is of great interest to investigate the efficiency improvement of GTCC plant... Many F class gas turbine combined cycle (GTCC) power plants are built in China at present because of less emission and high efficiency. It is of great interest to investigate the efficiency improvement of GTCC plant. A combined cycle with three-pressure reheat heat recovery steam generator (HRSG) is selected for study in this paper. In order to maximize the GTCC efficiency, the optimization of the HRSG operating parameters is performed. The operating parameters are determined by means of a thermodynamic analysis, i.e. the minimization of exergy losses. The influence of HRSG inlet gas temperature on the steam bottoming cycle efficiency is discussed. The result shows that increasing the HRSG inlet temperature has less improvement to steam cycle efficiency when it is over 590℃. Partial gas to gas recuperation in the topping cycle is studied. Joining HRSG optimization with the use of gas to gas heat recuperation, the combined plant efficiency can rise up to 59.05% at base load. In addition, the part load performance of the GTCC power plant gets much better. The efficiency is increased by 2.11% at 75% load and by 4.17% at 50% load. 展开更多
关键词 Heat Recovery Steam Generators (HRSG) Thermodynamic optimization Exergy analysis Combined cycle power plant EFFICIENCY Heat rate
原文传递
Real-time impact of power balancing on power system operation with large scale integration of wind power 被引量:8
11
作者 Abdul BASIT Anca D.HANSEN +1 位作者 Poul E.SØRENSEN Georgios GIANNOPOULOS 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第2期202-210,共9页
Highly wind power integrated power system requires continuous active power regulation to tackle the power imbalances resulting from the wind power forecast errors. The active power balance is maintained in real-time w... Highly wind power integrated power system requires continuous active power regulation to tackle the power imbalances resulting from the wind power forecast errors. The active power balance is maintained in real-time with the automatic generation control and also from the control room, where regulating power bids are activated manually. In this article, an algorithm is developed to simulate the activation of regulating power bids, as performed in the control room, during power imbalance between generation and load demand. In addition, the active power balance is also controlled through automatic generation control, where coordinated control strategy between combined heat and power plants and wind power plant enhances the secure power system operation. The developed algorithm emulating the control room response,to deal with real-time power imbalance, is applied and investigated on the future Danish power system model. The power system model takes the hour-ahead regulating power plan from power balancing model and the generation and power exchange capacities for the year 2020 into account.The real-time impact of power balancing in a highly wind power integrated power system is assessed and discussed by means of simulations for different possible scenarios. 展开更多
关键词 Wind power plant(WPP) Simulation power Balancing model(SimBa) Centralised or de-centralised combined heat and power plant(CHP or DCHP) Automatic generation control(AGC) Rolling balance
原文传递
Identifying Critical Components of Combined Cycle Power Plants for Implementation of Reliability-centered Maintenance 被引量:2
12
作者 Hamed Sabouhi Mahmud Fotuhi-Firuzabad Payman Dehghanian 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第2期87-97,共11页
Maintenance scheduling and asset management practices play an important role in power systems,specifically in power generating plants.This paper presents a novel riskbased framework for a criticality assessment of pla... Maintenance scheduling and asset management practices play an important role in power systems,specifically in power generating plants.This paper presents a novel riskbased framework for a criticality assessment of plant components as a means to conduct more focused maintenance activities.Critical components in power plants that influence overall system performance are identified by quantifying their failure impact on system reliability,electric safety,cost,and the environment.Prioritization of plant components according to the proposed risk-based method ensures that the most effective and techno-economic investment decisions are implemented.This,in turn,helps to initiate modern maintenance approaches,such as reliability-centered maintenance(RCM).The proposed method is applied to a real combined cycle power plant(CCPP)in Iran,composed of two gas turbine power plants(GTPP)and one steam turbine power plant(STPP).The results demonstrate the practicality and applicability of the presented approach in real world practices. 展开更多
关键词 Combined cycle power plant(CCPP) critical component gas turbine power plant(GTPP) reliability-centered maintenance(RCM) RISK safety steam turbine power plant(STPP)
原文传递
Value assessment of hydrogen-based electrical energy storage in view of electricity spot market 被引量:2
13
作者 Shi YOU Junjie HU +1 位作者 Yi ZONG Jin LIN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第4期626-635,共10页
Hydrogen as an energy carrier represents one of the most promising carbon-free energy solutions.The ongoing development of power-to-gas(Pt G)technologies that supports large-scale utilization of hydrogen is therefore ... Hydrogen as an energy carrier represents one of the most promising carbon-free energy solutions.The ongoing development of power-to-gas(Pt G)technologies that supports large-scale utilization of hydrogen is therefore expected to support hydrogen economy with a final breakthrough.In this paper,the economic performance of a MW-sized hydrogen system,i.e.a composition of water electrolysis,hydrogen storage,and fuel cell combined heat and power plant(FCCHP),is assessed as an example of hydrogen-based bidirectional electrical energy storage(EES).The analysis is conducted in view of the Danish electricity spot market that has high price volatility due to its high share of wind power.An economic dispatch model is developed as a mixed-integer programming(MIP)problem to support the estimation of variable cost of such a system taking into account a good granularity of the technical details.Based on a projected technology improvement by 2020,sensitivity analysis is conducted to illustrate how much the hydrogen-based EES is sensitive to variations of the hydrogen price and the capacity of hydrogen storage. 展开更多
关键词 Electrical energy storage(EES) Electricity spot market Fuel cell combined heat and power plant(FCCHP) HYDROGEN Hydrogen storage Mixed-integer programming(MIP)
原文传递
Dispatch Model for Integrated Heat and Power Systems Considering Internal Composition of CHP Plants 被引量:3
14
作者 Tuo Jiang Yong Min +3 位作者 Guiping Zhou Lei Chen Qun Chen Fei Xu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第2期396-407,共12页
An integrated heat and power system(IHPS)is a promising approach for alleviating wind curtailment problems.In an IHPS,the combined heat and power(CHP)plant is the key component,which supplies both heat and electric lo... An integrated heat and power system(IHPS)is a promising approach for alleviating wind curtailment problems.In an IHPS,the combined heat and power(CHP)plant is the key component,which supplies both heat and electric loads,and couples the thermal system and power system.However,existing research commonly ignores or simplifies the internal composition of CHP plants,which could lead to some unavoidable errors.This paper focuses on the internal composition of CHP plants,and models the physical processes in different components and flexible resources in the CHP plant.Furthermore,a joint dispatch problem of an IHPS with the above CHP plant models is formulated,and an iterative algorithm is developed to handle the nonlinearity in this problem.Case studies are performed based on a real CHP plant in Northern China,and the results indicate that the synergistic effect of different energy resources in the CHP plant is realized by the joint dispatch model,which promotes wind power accommodation and reduces fossil fuel consumption. 展开更多
关键词 Combined heat and power(CHP)plant CHP unit economic dispatch Integrated heat and power system wind power integration
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部