By using the modified iteration method of large deflection theory of plates with variable thichness[1], we solve the problem of circular plates with variable thickness subjected to combined loads under the boundary co...By using the modified iteration method of large deflection theory of plates with variable thichness[1], we solve the problem of circular plates with variable thickness subjected to combined loads under the boundary conditions of the clamped edges and get comparatively more accurate second-order approximate analytical solution. If the results of this paper are degraded into the special cases, the results coinciding with those of papers [1,2] can be obtained. In this paper, the characteristic curves are plotted and some comparisons are made. The results of this paper are satisfactory.展开更多
BACKGROUND Periprosthetic supracondylar femoral fractures(PSFs)present a challenge in terms of optimizing fixation in patients with poor bone quality.Surgical treatment and peri-operative management of PSFs in the eld...BACKGROUND Periprosthetic supracondylar femoral fractures(PSFs)present a challenge in terms of optimizing fixation in patients with poor bone quality.Surgical treatment and peri-operative management of PSFs in the elderly remain a burden for orthopedic surgeons.Among different treatment options,locking plate(LP)and retrograde intramedullary nail(RIMN)have shown favorable results.However,reduced mobility and protected weight-bearing are often present in the postoperative older population.With a purpose of allowing for early weight-bearing,a modified nail plate combination(NPC)was redesigned for PSF management.CASE SUMMARY In our cases,two elderly osteoporotic female underwent total knee arthroplasty(TKA),and then suffered from low energy trauma onto their knees after falling to the floor.Plain radiographs or computed tomography scans demonstrated oblique or transverse PSFs,both of which occurred at the distal femur above TKA.The modified NPC technique was performed for treatment of PSFs.The patient was made foot flat weight bearing in 1 wk.At 6-mo follow-up,the union was ultimately achieved using modified NPC with satisfactory implant outcomes.CONCLUSION Neither LP nor RIMN alone may provide adequate support to allow for union in circumstances where the patient has severely osteopenic bone.Therefore,developing a modified implant offer an alternative choice for treating PSFs.These two cases revealed that this technique is a viable option for the geriatric osteoporotic PSFs,offering safe,early weight bearing and favorable clinical outcomes.展开更多
Vibrational power flow on combined plates with a change in mass and stiffness or with viscoelastic damping layer used widely in engineering is studied. The expressions of flexural displacement and other physical quan...Vibrational power flow on combined plates with a change in mass and stiffness or with viscoelastic damping layer used widely in engineering is studied. The expressions of flexural displacement and other physical quantities are obtained using Laplace transformation and transfer matrix approach, then influences of changes in mass and stiffness of discontinuous material and the free damping layer on the input power flow and the transmitted power flow are discussed. The conclusions provide theory basis for structural optimization design and reducing noise and vibration展开更多
文摘By using the modified iteration method of large deflection theory of plates with variable thichness[1], we solve the problem of circular plates with variable thickness subjected to combined loads under the boundary conditions of the clamped edges and get comparatively more accurate second-order approximate analytical solution. If the results of this paper are degraded into the special cases, the results coinciding with those of papers [1,2] can be obtained. In this paper, the characteristic curves are plotted and some comparisons are made. The results of this paper are satisfactory.
文摘BACKGROUND Periprosthetic supracondylar femoral fractures(PSFs)present a challenge in terms of optimizing fixation in patients with poor bone quality.Surgical treatment and peri-operative management of PSFs in the elderly remain a burden for orthopedic surgeons.Among different treatment options,locking plate(LP)and retrograde intramedullary nail(RIMN)have shown favorable results.However,reduced mobility and protected weight-bearing are often present in the postoperative older population.With a purpose of allowing for early weight-bearing,a modified nail plate combination(NPC)was redesigned for PSF management.CASE SUMMARY In our cases,two elderly osteoporotic female underwent total knee arthroplasty(TKA),and then suffered from low energy trauma onto their knees after falling to the floor.Plain radiographs or computed tomography scans demonstrated oblique or transverse PSFs,both of which occurred at the distal femur above TKA.The modified NPC technique was performed for treatment of PSFs.The patient was made foot flat weight bearing in 1 wk.At 6-mo follow-up,the union was ultimately achieved using modified NPC with satisfactory implant outcomes.CONCLUSION Neither LP nor RIMN alone may provide adequate support to allow for union in circumstances where the patient has severely osteopenic bone.Therefore,developing a modified implant offer an alternative choice for treating PSFs.These two cases revealed that this technique is a viable option for the geriatric osteoporotic PSFs,offering safe,early weight bearing and favorable clinical outcomes.
文摘Vibrational power flow on combined plates with a change in mass and stiffness or with viscoelastic damping layer used widely in engineering is studied. The expressions of flexural displacement and other physical quantities are obtained using Laplace transformation and transfer matrix approach, then influences of changes in mass and stiffness of discontinuous material and the free damping layer on the input power flow and the transmitted power flow are discussed. The conclusions provide theory basis for structural optimization design and reducing noise and vibration