期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Validation for Microbial Limit Test Method of Compound Yu E Nose Drops
1
作者 Renhui YANG Peixue CAO +1 位作者 Zhen ZENG Xiangling QU 《Agricultural Biotechnology》 CAS 2019年第5期125-128,共4页
[Objectives] This study was conducted to establish a method for microbial limit test of Compound Yu E Nose Drops.[Methods] According to the Chinese Pharmacopoei (General Rules in the fourth part of the 2015 edition),t... [Objectives] This study was conducted to establish a method for microbial limit test of Compound Yu E Nose Drops.[Methods] According to the Chinese Pharmacopoei (General Rules in the fourth part of the 2015 edition),the microbial limit test method for Compound Yu E Nose Drops was verified.[Results] Compound Yu E Nose Drops has a strong inhibitory effect on Staphylococcus aureus and Bacillus subtilis,and the inhibitory activity was significantly eliminated after increasing the diluent (1∶ 20).The recoveries were all in the range of 0.5-2.0 when the total quantities of aerobic microbes were determined by the dilution method (1∶ 20).When the total quantities of mould and yeast were determined by the conventional method,the recoveries were both in the range of 0.5-2.0.When examining control bacteria,Escherichia coli,S.aureus and Pseudomonas aeruginosa can all be detected in the test groups by the test liquid dilution method.[Conclusions] For Compound Yu E Nose Drops,the total quantities of aerobic microbe can be counted by the dilution method;the quantities of mould and yeast can be examined by the conventional plate method;and the conventional method can be used for control microbe examination. 展开更多
关键词 compound yu e NOSe drops MICROBIAL LIMIT test DILUTION method