An extended compromise ratio method(CRM) based on fuzzy distances is developed to solve fuzzy multi-attribute group decision making problems in which weights of attributes and ratings of alternatives on attributes a...An extended compromise ratio method(CRM) based on fuzzy distances is developed to solve fuzzy multi-attribute group decision making problems in which weights of attributes and ratings of alternatives on attributes are expressed with values of linguistic variables parameterized using triangular fuzzy numbers.A compromise solution is determined by introducing the ranking index based on the concept that the chosen alternative should be as close as possible to the positive ideal solution and as far away from the negative ideal solution as possible simultaneously.This proposed method is compared with other existing methods to show its feasibility and effectiveness and illustrated with an example of the military route selection problem as one of the possible applications.展开更多
A generator of the gliding arc jet (GAJ), which is driven by a transverse magnetic field, is developed to produce non-equilibrium plasma at atmospheric pressure. The gas temperature is estimated using the spectrum o...A generator of the gliding arc jet (GAJ), which is driven by a transverse magnetic field, is developed to produce non-equilibrium plasma at atmospheric pressure. The gas temperature is estimated using the spectrum of OH radicals to be about 2400±400 K. The determinations of electron temperature and electron density by using a line-ratio method are elaborated for the gliding arc jet plasma. This line-ratio method is based on a collisional-radiative model. The experiment results show that electron temperature is about 1.0 eV and electron density is about 6.9×1014 cm-3 . Obviously, the plasma of GAJ is in a non-equilibrium state.展开更多
An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accu...An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accurate monitoring of personal dose equivalent H_p(10)parameters for radiation workers.For this reason,in this paper we propose a method of combining composite screen detection technology,multichannel measurement technology,and the channel ratio method to achieve accurate measurement of the personal dose equivalent parameters.According to China National Standard GB/T 13161-2003 and National Verification Regulation JJG 1009-2006,the instrument was tested in the energy range between 48 keV and 1.25 MeV.The experimental results showed that the difference of energy response to ^(137)C_S corrected by the new method was almost constant within ±6.0%,which fulfilled the ±30% requirement of GB/T 13161-2003 and JJG1009-2006.Meanwhile,the method proposed obtained energy information regarding the radiation field.展开更多
基金supported by the National Natural Science Foundation of China (7087111770571086)
文摘An extended compromise ratio method(CRM) based on fuzzy distances is developed to solve fuzzy multi-attribute group decision making problems in which weights of attributes and ratings of alternatives on attributes are expressed with values of linguistic variables parameterized using triangular fuzzy numbers.A compromise solution is determined by introducing the ranking index based on the concept that the chosen alternative should be as close as possible to the positive ideal solution and as far away from the negative ideal solution as possible simultaneously.This proposed method is compared with other existing methods to show its feasibility and effectiveness and illustrated with an example of the military route selection problem as one of the possible applications.
基金supported by National Natural Science Foundation of China(Nos.10975136,11035005)USTC-NSRL Association Funding of China(No.KY2090130001)
文摘A generator of the gliding arc jet (GAJ), which is driven by a transverse magnetic field, is developed to produce non-equilibrium plasma at atmospheric pressure. The gas temperature is estimated using the spectrum of OH radicals to be about 2400±400 K. The determinations of electron temperature and electron density by using a line-ratio method are elaborated for the gliding arc jet plasma. This line-ratio method is based on a collisional-radiative model. The experiment results show that electron temperature is about 1.0 eV and electron density is about 6.9×1014 cm-3 . Obviously, the plasma of GAJ is in a non-equilibrium state.
基金supported by the National Key Scientific Instruments To Develop Dedicated(2013YQ090811)
文摘An electronic personal dosimeter mainly uses a Si-PIN photodiode as X-and gamma-ray detectors.The photon energy response of this instrument is inconsistent in the case of no correction,which seriously affects the accurate monitoring of personal dose equivalent H_p(10)parameters for radiation workers.For this reason,in this paper we propose a method of combining composite screen detection technology,multichannel measurement technology,and the channel ratio method to achieve accurate measurement of the personal dose equivalent parameters.According to China National Standard GB/T 13161-2003 and National Verification Regulation JJG 1009-2006,the instrument was tested in the energy range between 48 keV and 1.25 MeV.The experimental results showed that the difference of energy response to ^(137)C_S corrected by the new method was almost constant within ±6.0%,which fulfilled the ±30% requirement of GB/T 13161-2003 and JJG1009-2006.Meanwhile,the method proposed obtained energy information regarding the radiation field.