To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition a...To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition and working principle are introduced. The mapping relationship between the feature image coordinates and the measuring space coordinates is established. The method of measuring path planning of small field of view (FOV) images is proposed. With the cooperation of the panoramic image of the object to be measured, the small FOV images with high object plane resolution are acquired automatically. Then, the auxiliary measuring characteristics are constructed and the parameters of the features to be measured are automatically extracted. Experimental results show that the absolute value of relative error is less than 0. 03% when applying the cooperative measurement system to gauge the hole distance of 100 mm nominal size. When the object plane resolving power of the small FOV images is 16 times that of the large FOV image, the measurement accuracy of small FOV images is improved by 14 times compared with the large FOV image. It is suitable for high-precision automatic measurement of two-dimensional complex geometric features distributed on large scale parts.展开更多
Aiming at the problem that the data-driven automatic correlation methods which are difficult to adapt to the automatic correlation of oil-bearing strata with large changes in lateral sedimentary facies and strata thic...Aiming at the problem that the data-driven automatic correlation methods which are difficult to adapt to the automatic correlation of oil-bearing strata with large changes in lateral sedimentary facies and strata thickness,an intelligent automatic correlation method of oil-bearing strata based on pattern constraints is formed.We propose to introduce knowledge-driven in automatic correlation of oil-bearing strata,constraining the correlation process by stratigraphic sedimentary patterns and improving the similarity measuring machine and conditional constraint dynamic time warping algorithm to automate the correlation of marker layers and the interfaces of each stratum.The application in Shishen 100 block in the Shinan Oilfield of the Bohai Bay Basin shows that the coincidence rate of the marker layers identified by this method is over 95.00%,and the average coincidence rate of identified oil-bearing strata reaches 90.02% compared to artificial correlation results,which is about 17 percentage points higher than that of the existing automatic correlation methods.The accuracy of the automatic correlation of oil-bearing strata has been effectively improved.展开更多
An automatic monitoring method of the 3-D deformation is presented for crustal fault based on laser and machine vision. The laser source and screen are independently set up in the headwall and footwall, the collimated...An automatic monitoring method of the 3-D deformation is presented for crustal fault based on laser and machine vision. The laser source and screen are independently set up in the headwall and footwall, the collimated laser beam creates a circular spot on the screen, meanwhile, the industrial camera captures the tiny deformation of the crustal fault by monitoring the change of the spot position. This method significantly reduces the cost of equipment and labor, provides daily sampling to ensure high continuity of data. A prototype of the automatic monitoring system is developed, and a repeatability test indicates that the error of spot jitter can be minimized by consecutive samples. Meanwhile, the environmental correction model is determined to ensure that environmental changes do not disturb the system. Furthermore, the automatic monitoring system has been applied at the deformation monitoring station(KJX02) of China Beishan underground research laboratory, where continuous deformation monitoring is underway.展开更多
With the popularity of the automatic precipitation gauges in national weather stations,testing their performance and adjusting their measurements are top priorities. Additionally,because different climatic conditions ...With the popularity of the automatic precipitation gauges in national weather stations,testing their performance and adjusting their measurements are top priorities. Additionally,because different climatic conditions may have different effects on the performance of the precipitation gauges, it is also necessary to test the gauges in different areas. This study mainly analyzed precipitation measurements from the single-Altershielded TRwS204 automatic weighing gauge(TRwS_(SA)) relative to the adjusted manual measurements(reference precipitation) from the Chinese standard precipitation gauge in a doublefence wind shield(CSPG_(DF)) in the Hulu watershed in the Qilian Mountains, China. The measurements were compared over the period from August 2014 to July2017, and the transfer function derived from the work by Kochendorfer et al.(2017 a) for correcting windinduced losses was applied to the TRwS_(SA) measurements. The results show that the average loss of TRwS_(SA) measurements relative to the reference precipitation decreased from 0.55 mm(10.7%) to 0.51 mm(9.9%) for rainfall events, from 0.35 mm(8.5%)to 0.22 mm(5.3%) for sleet events, and from 0.49 mm(18.9%) to 0.33 mm(12.7%) for snowfall events after adjustment. The uncorrected large biases of TRwS_(SA) measurements are considered to be mainly caused by specific errors of TRwS_(SA), different gauge orifice area and random errors. These types of errors must be considered when comparing precipitation measurements for different gauge types, especially in the mountains.展开更多
An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, t...An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, the location of fetal abdomen is detected by image processing. Thereafter, an active contour model is converged along the abdominal boundary for measurement purposes. The validation data set contained 310 images of fetuses with gestational age (GA) from 14 to 41 weeks. The measurement success rate was 88.1%. By manually indicating the location of the abdomen, the success rate was further improved to 95.8% for the failed cases. The correlation between manual and automatic measurements was 0.95 and the intraclass correlation coefficient (ICC) was 0.976 (95% confidence interval (CI);0.969 - 0.981). The average method execution time was 0.3 s. The mean error was lower in young fetuses (0.4%) than in older fetuses (-2.1%). The proposed cross-platform method was implemented on a portable, low-cost ultrasound machine prototype targeted for low- and middle-income countries (LMIC);the results achieved were comparable to those of other state-of-the-art automatic methods.展开更多
An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for...An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for measurement is identified by the machine, the placement of the measurement calipers is automatically determined by fitting an active contour model to the structure of interest. The fetal biparietal diameter (BPD) and femur length (FL) are then measured automatically. The validation data set contained 167 and 197 B-mode images for BPD and FL measurements, respectively. The images were acquired using 4 different ultrasound scanners, which resulted in varied image quality and gain settings. The mean gestational age (GA) of the fetuses was 19.4 weeks, range 16 to 41 weeks. A measurement success rate of 90% was achieved for both BPD and FL. The correlation coefficients between the manual and automatic measurements were 0.995 (BPD) and 0.967 (FL), mean errors were 0.5 mm (BPD) and -1.7 mm (FL) and error range with 95% confidence interval (CI) were ﹣3.8 - 4.8 mm (BPD) and ﹣11.4 - 8.1 mm (FL). The automatic measurement results were consistent in both high and low gain settings. The intraclass correlation coefficients between manual and automatic measurements were 0.995 (95% CI;0.981 - 0.999) for BPD in high gain, 1.0 (95% CI;0.998 - 1.0) for BPD in low gain, 0.998 (95% CI;0.991 - 0.999) for FL in high gain and 0.999 (95% CI;0.996 - 1.0) for FL in low gain settings. The method was implemented on a prototype, portable ultrasound machine designed to be used in low- and middle-income countries (LMIC). The overall performance of the method supports our hypothesis that automated methods can be used and are beneficial in a clinical setting.展开更多
To measure the performance of high precision air-pressure sensors in below normal pressure,an automatic measurement instrument has been designed and implemented.It can simulate environment of low pressure from 300hPa ...To measure the performance of high precision air-pressure sensors in below normal pressure,an automatic measurement instrument has been designed and implemented.It can simulate environment of low pressure from 300hPa to 1 000hPa with high accuracy by proportional-integral-derivative(PID)control quickly,and it can also generate various relative humidity by two-pressure control.The results show that this instrument can reach controlled pressure quickly.And it works well with the minimum average pressure difference,and the fluctuation is±0.02hPa at 500hPa.And it can keep in a stable status for a long time.It works well in performance testing of pressure sensors.The structure of the system is simple,takes small investment,and can be operated conveniently.展开更多
In order to improve the compatibility of laser-induced breakdown spectroscopy( LIBS) instrument for different types of parts and optimize the analysis and testing processes,a modularized automatic measurement and cont...In order to improve the compatibility of laser-induced breakdown spectroscopy( LIBS) instrument for different types of parts and optimize the analysis and testing processes,a modularized automatic measurement and control system was developed. Based on the characteristics of each LIBS component, the following development steps have been performed:( 1) a summary of characteristic parameters of the component are established;( 2) the integration mechanism of multiple electrical interfaces is designed;( 3) the component control instruction library is developed. The experimental results indicate that the measurement and control system is compatible with most LIBS parts in the market.Spectrometer and laser can be compatible with at least three different types of parts. In addition,a multilayer iterative testing process is designed to improve the efficiency of optimization process of LIBS parameters. The experimental results have shown that the automatic optimization of the delay time compared to the manual testing provides significant gain in testing efficiency. The range of delay time in the experiments is 1. 28 to 10. 28 μs and the step value is 1,0. 5,0. 2 and 0. 1 μs. The gain in testing efficiency has been found to be increased by 73. 76%,75. 93%,78. 81% and 80. 42%,respectively.展开更多
Background: Complications after endoscopic retrieval of kidney and ureter stones are obviously related to the size of the stones as well as the experience of the surgeon and other factors. During the procedure it is s...Background: Complications after endoscopic retrieval of kidney and ureter stones are obviously related to the size of the stones as well as the experience of the surgeon and other factors. During the procedure it is sometimes difficult for surgeons to estimate stone size and therefore give prognostic advises. The visual perception of the stone size depends on the shape, colour, distance to the renoscope and dilatation of the ureter. This is the so-called binding problem, because shape, color and direction of motion are processed separately by different population of optical neurons. In order to establish a better prognostic rational especially for less experienced surgeons, we established an intra operative semi-quantitative measurement of the stone size supported by a stone basket. Materials and Methods: We modified the tipped, nitinol stone baskets from the company Urotech with diameters of 2.5, 3.0 and 4 FR. The handle of this basket has a spring mechanism, which automatically closes the basket and provides a predefined fixation force of the stones within the basket. On the handle we established a non-linear scale in mm by grabbing standardized balls or standardized screws. Result: The scales are nonlinear because of the nonlinear relation between the diameter of the stone and the distance of the slider. Also the scales differ in between the basket size, because of the different strain conditions due to the different wire sizes and materials or the spring and basket. Conclusion: This scale could be an important orientation for a surgeon during endourological procedures to estimate stone sizes. After further clinical experience a semi-quantitative visualization like green, yellow and red colors could help to predict potential complications due to large stone sizes. Finally it could bevery interesting for other disciplines like gastroenterology.展开更多
A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measur...A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.展开更多
Based on mobile devices as a solution for measurement faces interesting challenges, which involve poor human- computer interaction and limited computer capability. In this paper, we present the mobile sensing system ...Based on mobile devices as a solution for measurement faces interesting challenges, which involve poor human- computer interaction and limited computer capability. In this paper, we present the mobile sensing system (MSS) with func- tions of constructing, configuring and implementing measurement applications. MSS consists of a mobile device and a sensor probe, In the mobile device we install a pocket virtual instrument platform (PVIP), which has object-oriented software ar- chitecture and can be configured through extensible markup language (XML) files. And these configuration files can be written to the probe. Therefore, the probe can produce the measurement of APP in the mobile device. This infrastructure has been illustrated by a sound signal acquisition task and a flexible force measurement task which are finished with an android smartphone and a probe. These examples suggest that MSS is reconfigurable, highly automatical and flexible.展开更多
Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope(UTM) lens view image as an example, ...Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope(UTM) lens view image as an example, a 2-layer automatic recognition model for data reading is established after adopting a series of pre-processing algorithms. This model is an optimal combination of the correlation-based template matching method and a concurrent back propagation(BP) neural network. Multiple complementary feature extraction is used in generating the eigenvectors of the concurrent network. In order to improve fault-tolerance capacity, rotation invariant features based on Zernike moments are extracted from digit characters and a 4-dimensional group of the outline features is also obtained. Moreover, the operating time and reading accuracy can be adjusted dy-namically by setting the threshold value. The experimental result indicates that the newly developed algorithm has optimal recognition precision and working speed. The average reading ratio can achieve 97.23%. The recognition method can automatically obtain the results of optical measuring instruments rapidly and stably without modifying their original structure, which meets the application requirements.展开更多
Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error...Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error of water content in crude oil proposed in this paper is based on switching measuring ranges of on-line water content analyzer automatically.Measuring precision on data collected from oil field and analyzed by in-field operators can be impressively improved by using back propogation (BP) neural network to predict water content in output crude oil.Application results show that the difficulty in accurately measuring water-oil content ratio can be solved effectively through this combination of on-line measuring range automatic switching and real time prediction,as this method has been tested repeatedly on-site in oil fields with satisfactory prediction results.展开更多
An automatic heat flux-temperature measuring system can be used to measure local body heat flux, local skin temperature, body core temperature, and ambient temperature, as well as mean body heat flux, mean skin temper...An automatic heat flux-temperature measuring system can be used to measure local body heat flux, local skin temperature, body core temperature, and ambient temperature, as well as mean body heat flux, mean skin temperature, physiological shell thermal insulation and suit thermal insulation. This paper describes the measuring principle, hardware construction, software program and the application in thermal measurements on divers.展开更多
A mobile system comprising of a Geiger-Muller (GM) dosimeter connected with a smart phone was used for ambient gamma dose rate survey within the districts and on the roads within the state of Kuwait. While the dosimet...A mobile system comprising of a Geiger-Muller (GM) dosimeter connected with a smart phone was used for ambient gamma dose rate survey within the districts and on the roads within the state of Kuwait. While the dosimeter provides data on gamma dose rates, the smart phone provides the GPS navigation information and saves the data for subsequent analysis and mapping. The survey covered a total distance of about 2300 km within the country and 3117 data points were recorded to show the dose rate distribution on the map of Kuwait. The results show that the ambient dose rates in Kuwait range from 40 to 180 nSv.h-1 with a mean value of 103 nSv.h-1. The dosimetric system described has good potential as a tool for determining baseline background radiation dose rates in an area.展开更多
Automatic monitoring data of pollution sources is an important basis for environmental supervision and management.At present,it is difficult to guarantee the quality of automatic monitoring data of pollution sources,a...Automatic monitoring data of pollution sources is an important basis for environmental supervision and management.At present,it is difficult to guarantee the quality of automatic monitoring data of pollution sources,and it is difficult to play the role of the monitoring data.In response to this problem,the factors influencing the quality of automatic monitoring data of pollution sources were analyzed in detail,and technical assurance measures for the quality of automatic monitoring data of pollution sources in Shandong Province were studied.Besides,the dynamic management and control idea of automatic monitoring of pollution sources was proposed,and specific technical measures were analyzed from five aspects of standardizing automatic monitoring equipment of pollution sources,improving the data collection and transmission system,establishing a mechanism for reporting operating status information of monitoring equipment,setting alarm rules and alarm processing procedures,and statistically analyzing the operating status of the equipment.Practice has proved that the dynamic management and control system can effectively ensure the quality of automatic monitoring data of pollution sources.展开更多
Nowadays, asphalt road has dominated highways around the world. Among various defects of asphalt road, crackshave been paid more attention, since cracks often cause major engineering and personnel safety incidents. Cu...Nowadays, asphalt road has dominated highways around the world. Among various defects of asphalt road, crackshave been paid more attention, since cracks often cause major engineering and personnel safety incidents. Currentmanual crack inspection methods are time-consuming and labor-intensive, and most segmentation methods cannot detect cracks at the pixel level. This paper proposes an intelligent segmentation and measurement model basedon the modified Mask R-CNN algorithm to automatically and accurately detect asphalt road cracks. The modelproposed in this paper mainly includes a convolutional neural network (CNN), an optimized region proposalnetwork (RPN), a region of interest (RoI) Align layer, a candidate area classification network and a Mask branch offully convolutional network (FCN). The ratio and size of anchors in the RPN are adjusted to improve the accuracyand efficiency of segmentation. Soft non-maximum suppression (Soft-NMS) algorithm is developed to improvethe segmentation accuracy. A dataset including 8,689 images (512× 512 pixels) of asphalt cracks is established andthe road crack is manually marked. Transfer learning is used to initialize the model parameters in the trainingprocess. To optimize the model training parameters, multiple comparison experiments are performed, and the testresults show that the mean average precision (mAP) value and F1-score of the optimal trained model are 0.952 and0.949. Subsequently, the robustness verification test and comparative test of the trained model are conducted andthe topological features of the crack are extracted. Then, the damage area, length and average width of the crackare measured automatically and accurately at pixel level. More importantly, this paper develops an automatic crackdetection platform for asphalt roads to automatically extract the number, area, length and average width of cracks,which can significantly improve the crack detection efficiency for the road maintenance industry.展开更多
Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (O...Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.展开更多
Automatic partition of Chinese sentence group is very important to the statistical machine translation system based on discourse. This paper presents an approach to this issue: first, each sentence in a discourse is ...Automatic partition of Chinese sentence group is very important to the statistical machine translation system based on discourse. This paper presents an approach to this issue: first, each sentence in a discourse is expressed as a feature vector; second, a special hierarchical clustering algorithm is applied to present a discourse as a sentence group tree. In this paper, local reoccurrence measure is proposed to the selection of key phras and the evaluation of the weight of key phrases. Experimental results show our approach promising.展开更多
The gel dosimeter has the uniquely capacity in recording radiation dose distribution in three dimensions(3D), which has the specific advantages in dosimetry measurements where steep dose gradients exist. In this study...The gel dosimeter has the uniquely capacity in recording radiation dose distribution in three dimensions(3D), which has the specific advantages in dosimetry measurements where steep dose gradients exist. In this study, a novel radiochromic gel dosimeter was developed by dispersing nanovesicles self-assembled by 10,12-pentacosadiynoic acid(PCDA) into the tissue equivalence gel matrix. The characteristics of radiochromic PCDA vesicle gel dosimeters were evaluated. Results indicate that these radiochromic gel dosimeters have good linear response to 1.7 Me V electron beam irradiation in the dose range of 0.32–6.36 k Gy. In addition,the radiochromic gel dosimeters overcome the limitations of the existing gel dosimeters such as diffusion effect,post-radiation effect, and poor forming ability. Hence, the radiochromic PCDA vesicle gel dosimeters developed could be generally applied to 3D dose distribution measurement with optical readout.展开更多
基金The National Natural Science Foundation of China(No.51175267)the Natural Science Foundation of Jiangsu Province(No.BK2010481)+2 种基金the Ph.D.Programs Foundation of Ministry of Education of China(No.20113219120004)China Postdoctoral Science Foundation(No.20100481148)the Postdoctoral Science Foundation of Jiangsu Province(No.1001004B)
文摘To realize high-precision automatic measurement of two-dimensional geometric features on parts, a cooperative measurement system based on machine vision is constructed. Its hardware structure, functional composition and working principle are introduced. The mapping relationship between the feature image coordinates and the measuring space coordinates is established. The method of measuring path planning of small field of view (FOV) images is proposed. With the cooperation of the panoramic image of the object to be measured, the small FOV images with high object plane resolution are acquired automatically. Then, the auxiliary measuring characteristics are constructed and the parameters of the features to be measured are automatically extracted. Experimental results show that the absolute value of relative error is less than 0. 03% when applying the cooperative measurement system to gauge the hole distance of 100 mm nominal size. When the object plane resolving power of the small FOV images is 16 times that of the large FOV image, the measurement accuracy of small FOV images is improved by 14 times compared with the large FOV image. It is suitable for high-precision automatic measurement of two-dimensional complex geometric features distributed on large scale parts.
基金Supported by the National Natural Science Foundation of China(42272110)CNPC-China University of Petroleum(Beijing)Strategic Cooperation Project(ZLZX2020-02).
文摘Aiming at the problem that the data-driven automatic correlation methods which are difficult to adapt to the automatic correlation of oil-bearing strata with large changes in lateral sedimentary facies and strata thickness,an intelligent automatic correlation method of oil-bearing strata based on pattern constraints is formed.We propose to introduce knowledge-driven in automatic correlation of oil-bearing strata,constraining the correlation process by stratigraphic sedimentary patterns and improving the similarity measuring machine and conditional constraint dynamic time warping algorithm to automate the correlation of marker layers and the interfaces of each stratum.The application in Shishen 100 block in the Shinan Oilfield of the Bohai Bay Basin shows that the coincidence rate of the marker layers identified by this method is over 95.00%,and the average coincidence rate of identified oil-bearing strata reaches 90.02% compared to artificial correlation results,which is about 17 percentage points higher than that of the existing automatic correlation methods.The accuracy of the automatic correlation of oil-bearing strata has been effectively improved.
基金supported by Earthquake Sciences Spark Programs of China Earthquake Administration(No.XH22020YA)Science Innovation Fund granted by the First Monitoring and Application Center of China Earthquake Administration(No.FMC202309).
文摘An automatic monitoring method of the 3-D deformation is presented for crustal fault based on laser and machine vision. The laser source and screen are independently set up in the headwall and footwall, the collimated laser beam creates a circular spot on the screen, meanwhile, the industrial camera captures the tiny deformation of the crustal fault by monitoring the change of the spot position. This method significantly reduces the cost of equipment and labor, provides daily sampling to ensure high continuity of data. A prototype of the automatic monitoring system is developed, and a repeatability test indicates that the error of spot jitter can be minimized by consecutive samples. Meanwhile, the environmental correction model is determined to ensure that environmental changes do not disturb the system. Furthermore, the automatic monitoring system has been applied at the deformation monitoring station(KJX02) of China Beishan underground research laboratory, where continuous deformation monitoring is underway.
基金supported primarily by the National Basic Research Program of China (2013CBA01806)the National Natural Sciences Foundation of China (41671029, 41690141, 41401040 and 41501040)
文摘With the popularity of the automatic precipitation gauges in national weather stations,testing their performance and adjusting their measurements are top priorities. Additionally,because different climatic conditions may have different effects on the performance of the precipitation gauges, it is also necessary to test the gauges in different areas. This study mainly analyzed precipitation measurements from the single-Altershielded TRwS204 automatic weighing gauge(TRwS_(SA)) relative to the adjusted manual measurements(reference precipitation) from the Chinese standard precipitation gauge in a doublefence wind shield(CSPG_(DF)) in the Hulu watershed in the Qilian Mountains, China. The measurements were compared over the period from August 2014 to July2017, and the transfer function derived from the work by Kochendorfer et al.(2017 a) for correcting windinduced losses was applied to the TRwS_(SA) measurements. The results show that the average loss of TRwS_(SA) measurements relative to the reference precipitation decreased from 0.55 mm(10.7%) to 0.51 mm(9.9%) for rainfall events, from 0.35 mm(8.5%)to 0.22 mm(5.3%) for sleet events, and from 0.49 mm(18.9%) to 0.33 mm(12.7%) for snowfall events after adjustment. The uncorrected large biases of TRwS_(SA) measurements are considered to be mainly caused by specific errors of TRwS_(SA), different gauge orifice area and random errors. These types of errors must be considered when comparing precipitation measurements for different gauge types, especially in the mountains.
文摘An automatic method for measuring the fetal mean abdominal diameter (MAD) or abdominal circumference (AC) with ultrasound is proposed. From a correctly presented abdominal section suitable for MAD or AC measurement, the location of fetal abdomen is detected by image processing. Thereafter, an active contour model is converged along the abdominal boundary for measurement purposes. The validation data set contained 310 images of fetuses with gestational age (GA) from 14 to 41 weeks. The measurement success rate was 88.1%. By manually indicating the location of the abdomen, the success rate was further improved to 95.8% for the failed cases. The correlation between manual and automatic measurements was 0.95 and the intraclass correlation coefficient (ICC) was 0.976 (95% confidence interval (CI);0.969 - 0.981). The average method execution time was 0.3 s. The mean error was lower in young fetuses (0.4%) than in older fetuses (-2.1%). The proposed cross-platform method was implemented on a portable, low-cost ultrasound machine prototype targeted for low- and middle-income countries (LMIC);the results achieved were comparable to those of other state-of-the-art automatic methods.
文摘An automatic method able to recognize a presented section through the biparietal plane of the fetal head and a section through the fetal femur in ultrasound images is developed. Once the correct anatomical section for measurement is identified by the machine, the placement of the measurement calipers is automatically determined by fitting an active contour model to the structure of interest. The fetal biparietal diameter (BPD) and femur length (FL) are then measured automatically. The validation data set contained 167 and 197 B-mode images for BPD and FL measurements, respectively. The images were acquired using 4 different ultrasound scanners, which resulted in varied image quality and gain settings. The mean gestational age (GA) of the fetuses was 19.4 weeks, range 16 to 41 weeks. A measurement success rate of 90% was achieved for both BPD and FL. The correlation coefficients between the manual and automatic measurements were 0.995 (BPD) and 0.967 (FL), mean errors were 0.5 mm (BPD) and -1.7 mm (FL) and error range with 95% confidence interval (CI) were ﹣3.8 - 4.8 mm (BPD) and ﹣11.4 - 8.1 mm (FL). The automatic measurement results were consistent in both high and low gain settings. The intraclass correlation coefficients between manual and automatic measurements were 0.995 (95% CI;0.981 - 0.999) for BPD in high gain, 1.0 (95% CI;0.998 - 1.0) for BPD in low gain, 0.998 (95% CI;0.991 - 0.999) for FL in high gain and 0.999 (95% CI;0.996 - 1.0) for FL in low gain settings. The method was implemented on a prototype, portable ultrasound machine designed to be used in low- and middle-income countries (LMIC). The overall performance of the method supports our hypothesis that automated methods can be used and are beneficial in a clinical setting.
基金National Basic Research Program of China(No.2011CB302104)Special Fund for Public Welfare(No.GYHY201004004)
文摘To measure the performance of high precision air-pressure sensors in below normal pressure,an automatic measurement instrument has been designed and implemented.It can simulate environment of low pressure from 300hPa to 1 000hPa with high accuracy by proportional-integral-derivative(PID)control quickly,and it can also generate various relative humidity by two-pressure control.The results show that this instrument can reach controlled pressure quickly.And it works well with the minimum average pressure difference,and the fluctuation is±0.02hPa at 500hPa.And it can keep in a stable status for a long time.It works well in performance testing of pressure sensors.The structure of the system is simple,takes small investment,and can be operated conveniently.
基金National M ajor Scientific Instruments and Equipment Development Special Funds,China(No.2011YQ030113)
文摘In order to improve the compatibility of laser-induced breakdown spectroscopy( LIBS) instrument for different types of parts and optimize the analysis and testing processes,a modularized automatic measurement and control system was developed. Based on the characteristics of each LIBS component, the following development steps have been performed:( 1) a summary of characteristic parameters of the component are established;( 2) the integration mechanism of multiple electrical interfaces is designed;( 3) the component control instruction library is developed. The experimental results indicate that the measurement and control system is compatible with most LIBS parts in the market.Spectrometer and laser can be compatible with at least three different types of parts. In addition,a multilayer iterative testing process is designed to improve the efficiency of optimization process of LIBS parameters. The experimental results have shown that the automatic optimization of the delay time compared to the manual testing provides significant gain in testing efficiency. The range of delay time in the experiments is 1. 28 to 10. 28 μs and the step value is 1,0. 5,0. 2 and 0. 1 μs. The gain in testing efficiency has been found to be increased by 73. 76%,75. 93%,78. 81% and 80. 42%,respectively.
文摘Background: Complications after endoscopic retrieval of kidney and ureter stones are obviously related to the size of the stones as well as the experience of the surgeon and other factors. During the procedure it is sometimes difficult for surgeons to estimate stone size and therefore give prognostic advises. The visual perception of the stone size depends on the shape, colour, distance to the renoscope and dilatation of the ureter. This is the so-called binding problem, because shape, color and direction of motion are processed separately by different population of optical neurons. In order to establish a better prognostic rational especially for less experienced surgeons, we established an intra operative semi-quantitative measurement of the stone size supported by a stone basket. Materials and Methods: We modified the tipped, nitinol stone baskets from the company Urotech with diameters of 2.5, 3.0 and 4 FR. The handle of this basket has a spring mechanism, which automatically closes the basket and provides a predefined fixation force of the stones within the basket. On the handle we established a non-linear scale in mm by grabbing standardized balls or standardized screws. Result: The scales are nonlinear because of the nonlinear relation between the diameter of the stone and the distance of the slider. Also the scales differ in between the basket size, because of the different strain conditions due to the different wire sizes and materials or the spring and basket. Conclusion: This scale could be an important orientation for a surgeon during endourological procedures to estimate stone sizes. After further clinical experience a semi-quantitative visualization like green, yellow and red colors could help to predict potential complications due to large stone sizes. Finally it could bevery interesting for other disciplines like gastroenterology.
文摘A fast automatic AC-DC switch is designed and fabricated mainly by a microcontroller and three double poles single throw reed relays.This new switch is introduced to establish a fully automated system for AC-DC measurements through ACDC transfer standards for the first time at the National Institute for standards(N IS)in Egypt.The implemented circuit of theautomatic AC-DC switch and its protection are presented in details.An AC voltage source is calibrated against DC voltagesource by using the demonstrated automatic switch as an application The calibrated voltage ranges are2V,6V,20V and60V as examples.The uncertainty budget is also evaluated for the calibrated values.
基金The Ministry of Science and Technology of the People's Republic of China,Within the Framework of the Project the CNC Products innovation demonstration(No.2012BAF13B06)
文摘Based on mobile devices as a solution for measurement faces interesting challenges, which involve poor human- computer interaction and limited computer capability. In this paper, we present the mobile sensing system (MSS) with func- tions of constructing, configuring and implementing measurement applications. MSS consists of a mobile device and a sensor probe, In the mobile device we install a pocket virtual instrument platform (PVIP), which has object-oriented software ar- chitecture and can be configured through extensible markup language (XML) files. And these configuration files can be written to the probe. Therefore, the probe can produce the measurement of APP in the mobile device. This infrastructure has been illustrated by a sound signal acquisition task and a flexible force measurement task which are finished with an android smartphone and a probe. These examples suggest that MSS is reconfigurable, highly automatical and flexible.
文摘Based on a comprehensive study of various algorithms, the automatic recognition of traditional ocular optical measuring instruments is realized. Taking a universal tools microscope(UTM) lens view image as an example, a 2-layer automatic recognition model for data reading is established after adopting a series of pre-processing algorithms. This model is an optimal combination of the correlation-based template matching method and a concurrent back propagation(BP) neural network. Multiple complementary feature extraction is used in generating the eigenvectors of the concurrent network. In order to improve fault-tolerance capacity, rotation invariant features based on Zernike moments are extracted from digit characters and a 4-dimensional group of the outline features is also obtained. Moreover, the operating time and reading accuracy can be adjusted dy-namically by setting the threshold value. The experimental result indicates that the newly developed algorithm has optimal recognition precision and working speed. The average reading ratio can achieve 97.23%. The recognition method can automatically obtain the results of optical measuring instruments rapidly and stably without modifying their original structure, which meets the application requirements.
基金Sponsored by the Basic Research Fundation of Beijing Institute of Technology (200705422009)
文摘Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error of water content in crude oil proposed in this paper is based on switching measuring ranges of on-line water content analyzer automatically.Measuring precision on data collected from oil field and analyzed by in-field operators can be impressively improved by using back propogation (BP) neural network to predict water content in output crude oil.Application results show that the difficulty in accurately measuring water-oil content ratio can be solved effectively through this combination of on-line measuring range automatic switching and real time prediction,as this method has been tested repeatedly on-site in oil fields with satisfactory prediction results.
文摘An automatic heat flux-temperature measuring system can be used to measure local body heat flux, local skin temperature, body core temperature, and ambient temperature, as well as mean body heat flux, mean skin temperature, physiological shell thermal insulation and suit thermal insulation. This paper describes the measuring principle, hardware construction, software program and the application in thermal measurements on divers.
文摘A mobile system comprising of a Geiger-Muller (GM) dosimeter connected with a smart phone was used for ambient gamma dose rate survey within the districts and on the roads within the state of Kuwait. While the dosimeter provides data on gamma dose rates, the smart phone provides the GPS navigation information and saves the data for subsequent analysis and mapping. The survey covered a total distance of about 2300 km within the country and 3117 data points were recorded to show the dose rate distribution on the map of Kuwait. The results show that the ambient dose rates in Kuwait range from 40 to 180 nSv.h-1 with a mean value of 103 nSv.h-1. The dosimetric system described has good potential as a tool for determining baseline background radiation dose rates in an area.
文摘Automatic monitoring data of pollution sources is an important basis for environmental supervision and management.At present,it is difficult to guarantee the quality of automatic monitoring data of pollution sources,and it is difficult to play the role of the monitoring data.In response to this problem,the factors influencing the quality of automatic monitoring data of pollution sources were analyzed in detail,and technical assurance measures for the quality of automatic monitoring data of pollution sources in Shandong Province were studied.Besides,the dynamic management and control idea of automatic monitoring of pollution sources was proposed,and specific technical measures were analyzed from five aspects of standardizing automatic monitoring equipment of pollution sources,improving the data collection and transmission system,establishing a mechanism for reporting operating status information of monitoring equipment,setting alarm rules and alarm processing procedures,and statistically analyzing the operating status of the equipment.Practice has proved that the dynamic management and control system can effectively ensure the quality of automatic monitoring data of pollution sources.
基金This research was funded by the National Key Research and Development Program of China(No.2017YFC1501204)the National Natural Science Foundation of China(No.51678536)+4 种基金the Guangdong Innovative and Entrepreneurial Research Team Program(2016ZT06N340)the Program for Science and Technology Innovation Talents in Universities of Henan Province(Grant No.19HASTIT043)the Outstanding Young Talent Research Fund of Zhengzhou University(1621323001)the Program for Innovative Research Team(in Science and Technology)in University of Henan Province(18IRTSTHN007)the Research on NonDestructive Testing(NDT)and Rapid Evaluation Technology for Grouting Quality of Prestressed Ducts(Contract No.HG-GCKY-01-002).The authors would like to thank for these financial supports.
文摘Nowadays, asphalt road has dominated highways around the world. Among various defects of asphalt road, crackshave been paid more attention, since cracks often cause major engineering and personnel safety incidents. Currentmanual crack inspection methods are time-consuming and labor-intensive, and most segmentation methods cannot detect cracks at the pixel level. This paper proposes an intelligent segmentation and measurement model basedon the modified Mask R-CNN algorithm to automatically and accurately detect asphalt road cracks. The modelproposed in this paper mainly includes a convolutional neural network (CNN), an optimized region proposalnetwork (RPN), a region of interest (RoI) Align layer, a candidate area classification network and a Mask branch offully convolutional network (FCN). The ratio and size of anchors in the RPN are adjusted to improve the accuracyand efficiency of segmentation. Soft non-maximum suppression (Soft-NMS) algorithm is developed to improvethe segmentation accuracy. A dataset including 8,689 images (512× 512 pixels) of asphalt cracks is established andthe road crack is manually marked. Transfer learning is used to initialize the model parameters in the trainingprocess. To optimize the model training parameters, multiple comparison experiments are performed, and the testresults show that the mean average precision (mAP) value and F1-score of the optimal trained model are 0.952 and0.949. Subsequently, the robustness verification test and comparative test of the trained model are conducted andthe topological features of the crack are extracted. Then, the damage area, length and average width of the crackare measured automatically and accurately at pixel level. More importantly, this paper develops an automatic crackdetection platform for asphalt roads to automatically extract the number, area, length and average width of cracks,which can significantly improve the crack detection efficiency for the road maintenance industry.
基金National Natural Science Foundation of China (10475112)Western Light Foundation of 2005 years
文摘Alkaline earth sulfides (MgS,CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity,short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation.In this paper,an OSL dosimeter is described.It has linear dose response from 0.01 to 1000 Gy.The equipment,relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.
基金National High Technology Research and Development Program of China ( No.2006AA01Z139)Young NaturalScience Foundation of Fujian Province of China ( No.2008F3105)+1 种基金Natural Science Foundation of Fujian Province of China ( No.2006J0043)Fund of Key Research Project of Fujian Province of China (No.2006H0038)
文摘Automatic partition of Chinese sentence group is very important to the statistical machine translation system based on discourse. This paper presents an approach to this issue: first, each sentence in a discourse is expressed as a feature vector; second, a special hierarchical clustering algorithm is applied to present a discourse as a sentence group tree. In this paper, local reoccurrence measure is proposed to the selection of key phras and the evaluation of the weight of key phrases. Experimental results show our approach promising.
基金Supported by National Natural Science Foundation of China(No.81301934)the Science and Technology Development Foundation of China Academy of Engineering Physics(No.2013B0301035)
文摘The gel dosimeter has the uniquely capacity in recording radiation dose distribution in three dimensions(3D), which has the specific advantages in dosimetry measurements where steep dose gradients exist. In this study, a novel radiochromic gel dosimeter was developed by dispersing nanovesicles self-assembled by 10,12-pentacosadiynoic acid(PCDA) into the tissue equivalence gel matrix. The characteristics of radiochromic PCDA vesicle gel dosimeters were evaluated. Results indicate that these radiochromic gel dosimeters have good linear response to 1.7 Me V electron beam irradiation in the dose range of 0.32–6.36 k Gy. In addition,the radiochromic gel dosimeters overcome the limitations of the existing gel dosimeters such as diffusion effect,post-radiation effect, and poor forming ability. Hence, the radiochromic PCDA vesicle gel dosimeters developed could be generally applied to 3D dose distribution measurement with optical readout.