期刊文献+
共找到316篇文章
< 1 2 16 >
每页显示 20 50 100
Adult reference values of the computerized diplopia test 被引量:7
1
作者 Ling-Yun Zhou Tie-Juan Liu Xue-Mei Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第11期1646-1650,共5页
AIM: To estimate the adult reference values for measured deviations by a computerized diplopia test and testify the validity.METHODS: Totally 391 participants were recruited and taken the computerized diplopia test.... AIM: To estimate the adult reference values for measured deviations by a computerized diplopia test and testify the validity.METHODS: Totally 391 participants were recruited and taken the computerized diplopia test. The plots and amplitude of deviations were recorded. The differences in different gender, age and visual acuity groups were analyzed respectively. Of 30 subjects were enrolled to testify the interobserver reliability. Another 46 subjects(including 26 normal subjects and 20 patients) were taken the test and theirs deviations were recorded to testify the validity of the reference value.RESULTS: The max horizontal and vertical deviations were 2.55° and 0.76° with normal corrected visual acuity while 3.88° and 1.46° for subjects with poor corrected vision. The differences between age groups was insignificant(Z =3.615, 4.758; P =0.461, 0.313 for horizontal and vertical respectively). The max horizontal deviation of female was smaller than male(Z =-2.177; P =0.029),but the difference in max vertical deviation was insignificant(Z =-1.296; P =0.195). The mean difference between observers were both-0.1°, with 95% confidence limits(CI) of-1.4° and 1.6° in max horizontal deviations while-2.1° and 1.8° in max vertical deviation. The mean deviation of 26 normal subjects was 1.02° ±0.84° for horizontal and 0.47° ±0.30° for vertical which both within the range of reference values. The mean deviation of 20 patients was 13.51°±11.69° for horizontal and 8.34°±8.58°for vertical which both beyond the reference range.CONCLUSION: The max amplitude of horizontal and vertical deviation is pointed as the numerical parameters of computerized diplopia test. The reference values are different between normal corrected visual acuity and poor corrected vision. These values may useful for evaluating patients with diplopia in veriety conditions during clinical practice. 展开更多
关键词 computerized diplopia test referencevalues amplitude of deviations
下载PDF
Changes in reaction time, coefficient of variance of reaction time, and autonomic nerve function in the mental fatigue state caused by long-term computerized Kraepelin test workload in healthy volunteers 被引量:1
2
作者 Daisuke Kuratsune Seiki Tajima +10 位作者 Junichi Koizumi Kouzi Yamaguti Tetsuya Sasabe Kei Mizuno Masaaki Tanaka Naoko Okawa Hideki Mito Hirokazu Tsubone Yasuyoshi Watanabe Masayasu Inoue Hirohiko Kuratsune 《World Journal of Neuroscience》 2012年第2期113-118,共6页
Fatigue is a common sense caused by crushing labor, stressful social events and various illnesses. It is usually judged by their subjective symptoms, but it should be evaluated in an objective perspective. Here we sho... Fatigue is a common sense caused by crushing labor, stressful social events and various illnesses. It is usually judged by their subjective symptoms, but it should be evaluated in an objective perspective. Here we show that the decrease of working efficiency and sympathetic hyperactivity are associated with mental fatigue state caused by prolonged mental workload. Recently we made a new mental fatigue model of healthy volunteers caused by long-term computerized Kraepelin test (CKT) workload. CKT is our new software for automatically checking the calculation capability, with which it is easy to determine the reaction time (RT), coefficient of variance of reaction time (CV), and accuracy of the answers (AC) during tasks. We put 24 healthy volunteers into the fatigue state by subjecting them to 120 minutes’ CKT workload, and then studied the changes in fatigue sensation, RT, CV, and AC before and after the CKT workload. The fatigue sensation, RT, and CV were clearly increased by the fatigue-inducing task and recovered during the resting period. We also studied the changes in autonomic nerve activity by using heart rate variability analysis. The low/high frequency component ratio (LF/HF) was signifi-cantly increased by the fatigue-inducing task and decreased by resting, suggesting that mental stress causes a relatively sympathetic nerve activity-dominant state. Therefore, our new fatigue model involving a long-term CKT workload is a good mental fatigue model to provide much information about the fatigue state simultane-ously, and the increase of RT, CV, and proportion of sympathetic activity (LF/HF) are associated with mental fatigue state. These might be useful objective biomarkers or evaluating a mental fatigue state. 展开更多
关键词 Fatigue computerIZED Kraepelin test Reaction Time Accuracy of the ANSWERS AUTONOMIC NERVE Activity
下载PDF
Designing of A Computerized Cognitive Adaptive Testing Model
3
作者 He Lianzhen 《现代外语》 CSSCI 北大核心 1999年第2期169-171,共3页
Therecouldbenoscienceasweknowitwithoutmeasurement.Testing,includingallformsoflanguagetestingandpsychometricsitself,isoneformofmeasurement.Alanguagetestmaybedefinedasaprocedureforelicitinglanguageperformanceandaprocedu... Therecouldbenoscienceasweknowitwithoutmeasurement.Testing,includingallformsoflanguagetestingandpsychometricsitself,isoneformofmeasurement.Alanguagetestmaybedefinedasaprocedureforelicitinglanguageperformanceandaprocedureforassessingthatperformance.How... 展开更多
关键词 Item Response Theory (IRT) computerIZED ADAPTIVE testING (CAT ) COGNITIVE PSYCHOLOGY (CP) computerIZED COGNITIVE ADAPTIVE testing(CCAT)
下载PDF
The Differences of Interstitial Lung Diseases in High-Resolution Computerized Tomography and Pulmonary Function Test among Different Connective Tissue Diseases, and the Correlated Factors 被引量:1
4
作者 Zhen Jiang Wenyou Pan +1 位作者 Jinhui Tao Xiangpei Li 《Open Journal of Rheumatology and Autoimmune Diseases》 2018年第2期53-65,共13页
Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients w... Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis. 展开更多
关键词 CONNECTIVE Tissue Diseases INTERSTITIAL lung Disease HIGH-RESOLUTION computerIZED Tomography PULMONARY Function test Inflammation
下载PDF
A computerized resolution visual acuity test in preschool and school age children
5
作者 Ying-Yan Qin Zhen-Zhen Liu +5 位作者 Li-Yuan Zhu Xuan Bao Fu-Rong Luo Yi-Zhi Liu Young Tsau Ming-Xing Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第2期284-291,共8页
●AIM:To develop a novel approach called the Autoacuity Tester,and to evaluate its validity,especially the sensitivity and specificity for detecting amblyopia.●METHODS:Children aged from 3 to 12 y(n=552)were enrolled... ●AIM:To develop a novel approach called the Autoacuity Tester,and to evaluate its validity,especially the sensitivity and specificity for detecting amblyopia.●METHODS:Children aged from 3 to 12 y(n=552)were enrolled in the study.The validity of the Autoacuity Tester was evaluated by comparing it to the Tumbling E Early Treatment Diabetic Retinopathy Study(ETDRS)acuity chart for school age children,and Lea Symbols and Teller acuity card(TAC)for preschool children.The repeatability was assessed by coefficient of repeatability(COR).The sensitivity and specificity for detecting amblyopia were calculated.●RESULTS:The mean difference(95%limits of agreement)between the Autoacuity Tester and the ETDRS tests were-0.03(-0.24,0.19)logMAR for the school age group.In preschool children,the mean difference was 0.04(-0.14,0.21)logMAR between the Autoacuity Tester and the TAC and 0.00(-0.17,0.18)logMAR between the Autoacuity Tester and the Lea Symbols.For the school age group,the COR was 0.20 logMAR for the Autoacuity Tester and 0.18 logMAR for the ETDRS.For the preschool group,the COR was 0.13 logMAR for the Autoacuity Tester and 0.21 logMAR for TAC.The Autoacuity Tester(88%)is more sensitive than TAC(72%)in detecting amblyopia(P=0.04),while had similar specificity(92%vs 90%,P=0.20).●CONCLUSION:The Autoacuity Tester provides a reliable alternative for assessing visual acuity,and offers advantage of higher testability and repeatability for preschool children. 展开更多
关键词 visual ACUITY test computerIZED CHILDREN sensitivity AMBLYOPIA
下载PDF
CD-CAT中基于SCAD惩罚和EM视角的在线标定方法开发——G-DINA模型
6
作者 谭青蓉 蔡艳 +2 位作者 汪大勋 罗芬 涂冬波 《心理学报》 CSSCI CSCD 北大核心 2024年第5期670-688,I0005-I0007,共22页
G-DINA(the generalizeddeterministic input,noisy and gate)模型限制条件少,应用范围广,满足大量心理与教育评估测验数据的要求。研究提出一种适用于G-DINA等模型的同时标定新题Q矩阵与项目参数的认知诊断计算机化自适应测验(CD-CAT)... G-DINA(the generalizeddeterministic input,noisy and gate)模型限制条件少,应用范围广,满足大量心理与教育评估测验数据的要求。研究提出一种适用于G-DINA等模型的同时标定新题Q矩阵与项目参数的认知诊断计算机化自适应测验(CD-CAT)在线标定新方法SCADOCM,以期促进CD-CAT在实践中的推广与应用。本研究分别基于模拟题库以及真实题库进行研究,结果表明:相比传统的SIE方法,SCADOCM在各实验条件下均具有较为理想的标定精度与标定效率,应用前景较好;SIE方法不适用于饱和的G-DINA等模型,其各实验条件下的Q矩阵标定精度均较低。 展开更多
关键词 认知诊断计算机化自适应测验 在线标定 Q矩阵 G-DINA模型 SCAD惩罚
下载PDF
面向序列诊断的强化计算机自适应测验方法
7
作者 刘子瑞 吴金泽 +5 位作者 姚方舟 刘淇 陈恩红 沙晶 王士进 苏喻 《模式识别与人工智能》 EI CSCD 北大核心 2024年第1期13-26,共14页
计算机自适应测验旨在根据学生历史表现为学生选择合适的题目,快速有效地测量学生的真实能力.然而在智能教育场景下,现有自适应测验策略仍存在目标复杂和知识稀疏等问题.为此,文中构建用于智能场景的可精准测评学生知识能力的面向序列... 计算机自适应测验旨在根据学生历史表现为学生选择合适的题目,快速有效地测量学生的真实能力.然而在智能教育场景下,现有自适应测验策略仍存在目标复杂和知识稀疏等问题.为此,文中构建用于智能场景的可精准测评学生知识能力的面向序列诊断的强化计算机自适应测验方法,包括基于序列诊断的学生模拟器和学生画像模型,并针对真实场景中自适应测验的目标复杂性,设计薄弱点准确率、预测表现耦合、自适应测验时长、测验异常率和测验的难度结构这5个评价指标.进一步地,提出基于强化学习的计算机自适应测验选题策略,利用双通道自注意力学习及矛盾学习模块缓解知识稀疏的问题.真实数据上的实验表明,文中选题策略不仅可高效测量学生真实能力,还可优化学生的作答体验,同时选择的题目也具有一定的可解释性,从而为智能教育场景下的计算机自适应测验提供一个可行方案. 展开更多
关键词 智能教育 个性化教育 计算机自适应测验 强化学习 Q 学习
下载PDF
结合作答时间的自适应测验组卷方法
8
作者 李弘 罗照盛 喻晓锋 《南昌大学学报(理科版)》 CAS 2024年第4期384-395,共12页
随着信息技术发展和计算机化自适应测验应用的普及,作答时间数据作为测验过程信息越来越容易获得,在心理测量领域的应用越来越广泛。将作答时间及模型应用于自动化组卷,对提高测验效率、被试能力估计精度乃至教育公平都有非常重要的意... 随着信息技术发展和计算机化自适应测验应用的普及,作答时间数据作为测验过程信息越来越容易获得,在心理测量领域的应用越来越广泛。将作答时间及模型应用于自动化组卷,对提高测验效率、被试能力估计精度乃至教育公平都有非常重要的意义。本文通过对自适应测验中组卷方法及研究结果进行系统梳理,全面展示结合作答时间数据的组卷方法,探究该类组卷方法对测验总时间约束、测验效率、题库安全、被试作答时间差异等问题的解决方案。对结合作答时间数据的组卷方法进行拓展,以及将研究成果应用于我国的大规模测评项目,都是未来需要探索的重要研究方向。 展开更多
关键词 作答时间 自动化组卷 计算机化自适应测验 曝光控制 终止规则
下载PDF
非参数CD-CAT题库Q矩阵优化设计
9
作者 黄涛 汪文义 宋丽红 《江西师范大学学报(自然科学版)》 CAS 北大核心 2024年第3期276-285,共10页
开展非参数CD-CAT题库Q矩阵的优化设计,并将它用于指导题库题目编制或选择,且它无需模型参数估计,这对于促进非参数CD-CAT进入课堂评价至关重要.受p-优化的启发,该文提出比例法生成优化Q矩阵,同时将已有的参数化模型题库设计方法推广到... 开展非参数CD-CAT题库Q矩阵的优化设计,并将它用于指导题库题目编制或选择,且它无需模型参数估计,这对于促进非参数CD-CAT进入课堂评价至关重要.受p-优化的启发,该文提出比例法生成优化Q矩阵,同时将已有的参数化模型题库设计方法推广到非参数化题库Q矩阵的优化设计.模拟研究结果显示:比例法和推广的融合法都有较好表现,而且当题库量较少时比例法更有优势. 展开更多
关键词 计算机化自适应测验 非参数选题策略 认知诊断模型 判准率 优化设计
下载PDF
基于IRT的计算机化适应性测验的概念、类型及特征
10
作者 简小珠 张敏强 《中国考试》 CSSCI 北大核心 2024年第9期66-75,共10页
近年来,适应测验实践的需要,计算机化适应性测验(CAT)呈现多类型、多方向的发展态势。本文在总结梳理国内外相关文献基础上,讨论了基于项目反应理论(IRT)的CAT概念内涵,指出CAT的关键特征是试题难度参数与被试能力参数建立在同一量尺上... 近年来,适应测验实践的需要,计算机化适应性测验(CAT)呈现多类型、多方向的发展态势。本文在总结梳理国内外相关文献基础上,讨论了基于项目反应理论(IRT)的CAT概念内涵,指出CAT的关键特征是试题难度参数与被试能力参数建立在同一量尺上;并依据概念内涵,将目前CAT多样化测验形式归纳为三个大类,包括基于IRT的认知诊断计算机化适应性测验、计算机化多阶段适应性测验、计算机化分类测验。CAT测验的三大类型各有其测量技术特点与实践应用优势,均具有良好的发展前景。 展开更多
关键词 计算机化适应性测验 认知诊断计算机化适应性测验 计算机化多阶段适应性测验 计算机化分类测验
下载PDF
CAT分层类曝光控制策略研究新进展
11
作者 刘海东 虞芷筠 +3 位作者 李浩 秦春影 杨建芹 喻晓锋 《江西师范大学学报(自然科学版)》 CAS 北大核心 2024年第2期139-146,共8页
计算机化自适应测验(computerized adaptive testing,CAT)可以根据每一名考生的不同作答进行自适应选题,提高了测验精度.但高精度也伴随着高曝光风险,分层类项目曝光控制策略作为项目曝光控制的方法之一,是近年来曝光控制研究领域的热点... 计算机化自适应测验(computerized adaptive testing,CAT)可以根据每一名考生的不同作答进行自适应选题,提高了测验精度.但高精度也伴随着高曝光风险,分层类项目曝光控制策略作为项目曝光控制的方法之一,是近年来曝光控制研究领域的热点.同时,反应时(RT)的收集是CAT的一大优势,RT对于测验的实施具有重要价值.该文综合介绍了传统的分层策略,并结合RT的分层策略探讨当前分层策略应用于CAT项目曝光控制中存在的问题及其未来研究方向. 展开更多
关键词 计算机化自适应测验 反应时 项目曝光控制 分层策略 测验时间 选题策略
下载PDF
计算机自适应测验有效性检验的探索与优化
12
作者 李心钰 王超 陆宏 《现代教育技术》 CSSCI 2024年第6期123-132,共10页
计算机自适应测验(Computerized Adaptive Testing,CAT)的有效性检验是评定测验生成过程以及解释测验结果是否恰当、合理的必要步骤,然而系统性探讨CAT有效性检验的研究相对较少。为弥补其不足,文章在剖析CAT有效性检验内涵的基础上,首... 计算机自适应测验(Computerized Adaptive Testing,CAT)的有效性检验是评定测验生成过程以及解释测验结果是否恰当、合理的必要步骤,然而系统性探讨CAT有效性检验的研究相对较少。为弥补其不足,文章在剖析CAT有效性检验内涵的基础上,首先梳理了基于IRT的题库、模拟CAT与真实CAT有效性检验的基本内容。然后,文章针对题库中试题逐渐向多维度和多模态转变的特点,提出利用高阶因子模型与多质多法模型对多维度与多模态试题进行有效性检验的方法;同时建议从测验公平性的角度,检验CLT与CAT中个体人格特质对被试作答表现的影响是否具有跨组不变性,最终形成了一套符合时代发展的CAT有效性检验的完整流程,以期为CAT的持续改进及其在教育实践中的普及推广提供助力。 展开更多
关键词 计算机自适应测验 有效性检验 多维度与多模态试题 测验公平性
下载PDF
RompecPC: A computerized program to create and solve jigsaw puzzles
13
作者 Miguel Angel Guevara Marai Pérez Hernández +2 位作者 Marisela Hernández González Araceli Sanz-Martin Sonia Ramírez Zapata 《Journal of Biomedical Science and Engineering》 2013年第7期717-721,共5页
RompecPC is a computerized program designed to create and assemble jigsaw puzzles. The program automatically records the solver’s responses as the number of pieces positioned correctly, the number of correct and inco... RompecPC is a computerized program designed to create and assemble jigsaw puzzles. The program automatically records the solver’s responses as the number of pieces positioned correctly, the number of correct and incorrect movements, the number of times that she/he attempts to move a piece to the same place (perseverations), and the latency and place to which each piece is moved or attempted to be moved. These features facilitate the implementation and evaluation of puzzles while also reducing human error. Therefore, RompePC is a useful tool for the neuropsychological assessment of visuospatial skills in both clinical and experimental research. 展开更多
关键词 computerIZED testing NEUROPSYCHOLOGICAL test JIGSAW PUZZLES VISUOSPATIAL ABILITIES
下载PDF
计算机化神经认知评估工具预测老年患者早期术后认知功能障碍的价值 被引量:1
14
作者 汤昕宇 杨立状 +4 位作者 张慕春 黄孝慈 邵艳梅 杨梦思 胡宪文 《医学研究与战创伤救治》 CAS 北大核心 2023年第2期165-170,共6页
目的探讨计算机化神经认知评估工具预测老年患者早期术后认知功能障碍(POCD)的价值。方法选择2021年7月至2022年7月安徽医科大学第二附属医院骨科行初次单侧髋关节置换的65~85岁患者70例,于术前1 d和术后一周进行神经心理学测试和计算... 目的探讨计算机化神经认知评估工具预测老年患者早期术后认知功能障碍(POCD)的价值。方法选择2021年7月至2022年7月安徽医科大学第二附属医院骨科行初次单侧髋关节置换的65~85岁患者70例,于术前1 d和术后一周进行神经心理学测试和计算机化测试。神经心理学的测试内容包括简易智力量表(MMSE)、修订韦氏记忆量表和连线测试。计算机化神经认知评估工具主要包括诱饵辨别指数(LDI)和识别记忆分数(REC)。根据Z计分法判定是否发生POCD,进一步将患者分为POCD组(n=16)和非POCD组(n=54),借助受试者工作特征曲线(ROC)分析LDI和REC值预测及筛查早期POCD的效能。结果POCD组术前术后LDI均明显低于非POCD组(P<0.05),POCD组术后REC明显低于非POCD组(P<0.05)。POCD组术前计算机化神经认知评估工具诊断的准确率为67.2%,截断值为0.1567,敏感度为87.5%,特异度为44.4%,约登指数为0.319;POCD组术后计算机化神经认知评估工具诊断的准确率为69.8%,截断值为0.0917,敏感度为81.3%,特异度为59.3%,约登指数为0.406。结论计算机化神经认知评估工具有助于预测和筛查老年患者早期POCD的发生。 展开更多
关键词 认知功能评估 计算机化神经认知评估工具 神经心理学测试 术后认知功能障碍 髋关节置换术
下载PDF
多值评分CD-CAT的选题策略研究
15
作者 高旭亮 王芳 赵鹏娟 《心理科学》 CSSCI CSCD 北大核心 2023年第2期461-469,共9页
认知诊断计算机化自适应测验(Cognitive diagnosis computerized adaptive testing, CD-CAT)为心理和教育评估测验的发展提供了新的视角。目前,关于CD-CAT的研究主要是基于二值评分的模型展开,但是,在实际应用领域,存在很多多值评分数... 认知诊断计算机化自适应测验(Cognitive diagnosis computerized adaptive testing, CD-CAT)为心理和教育评估测验的发展提供了新的视角。目前,关于CD-CAT的研究主要是基于二值评分的模型展开,但是,在实际应用领域,存在很多多值评分数据。高效的选题方法是CD-CAT程序成功的核心要素,本研究提出了两种新的多值评分CD-CAT(polytomous CDCAT, PCD-CAT)的选题方法,期望后验方差(expected posterior variance, EPV)和最大期望距离(maximum expected distance,MED)。通过模拟实验比较了EPV和MED在PCD-CAT的效果。实验结果表明,与传统的选题方法相比,EPV和MED具有更高的测验精度和测验效率。最后,通过一个PISA数据分析检验了PCD-CAT在实际应用中的效果及其优势。 展开更多
关键词 认知诊断 计算机化自适应测验 多值评分
下载PDF
无损检测用工业CT几何尺寸校准方法的研究 被引量:1
16
作者 张健 唐莹 +3 位作者 曹丛 胡安继 武春利 王传海 《仪器仪表标准化与计量》 2023年第1期18-20,26,共4页
文章对工业CT几何参数校准方法,2D、3D模式下探测误差和长度测量误差的校准方法进行了研究,并采用不同标准器进行校准,克服了不同测量模式间的差异。项目成果对于规范工业CT几何参数校准工作,提升无损检测的评价质量,促进汽车、新材料... 文章对工业CT几何参数校准方法,2D、3D模式下探测误差和长度测量误差的校准方法进行了研究,并采用不同标准器进行校准,克服了不同测量模式间的差异。项目成果对于规范工业CT几何参数校准工作,提升无损检测的评价质量,促进汽车、新材料、装备制造、航空航天、国防领域高质量发展具有重要意义。 展开更多
关键词 工业CT 无损检测 几何参数 校准
下载PDF
基于用户体验与自适应的风景园林简史教育游戏小程序设计研究
17
作者 于冰沁 穆振宇 +3 位作者 张刘心 周帅 张政霖 叶子多 《园林》 2023年第5期24-32,共9页
在数字化赋能高等教育高质量发展的大背景下,以新媒体和移动终端为媒介的知识信息的快速传播方式广泛应用于教学的全周期过程中。以学生学习的痛点问题和学习体验为出发点,以“风景园林简史”课程为例,前端基于上瘾模型、正负反馈循环系... 在数字化赋能高等教育高质量发展的大背景下,以新媒体和移动终端为媒介的知识信息的快速传播方式广泛应用于教学的全周期过程中。以学生学习的痛点问题和学习体验为出发点,以“风景园林简史”课程为例,前端基于上瘾模型、正负反馈循环系统,设计用于课后知识点考核的教育游戏机制,并采用扁平化插画的方式,形成适用于移动端技术支持下小体量、简单、有趣的小程序游戏的视觉、触觉、听觉等多感官的体验。同时,后端依托JavaScript、WXML、WXSS等语言,基于计算机自适应测试技术,实现课程知识点测试游戏小程序的设计研发。该教育游戏可以有效激发学生的学习兴趣,提高知识巩固的效率,并通过人工智能算法为学生制定更加个性化的能力测试,对于专业教育、美育教育与人工智能技术融合方面的教学创新与资源迭代具有积极意义。 展开更多
关键词 教学游戏 用户体验 计算机自适应测试 微信小程序 风景园林简史
下载PDF
认知诊断测验蓝图的设计 被引量:70
18
作者 丁树良 汪文义 杨淑群 《心理科学》 CSSCI CSCD 北大核心 2011年第2期258-265,共8页
通常认为由属性和项目关联阵(即Q矩阵)的列对应的项目充任认知诊断测验中行为样本,其实这种做法不能有效防止理想反应模式的误判。如在测验之前便可确定欲测之属性及层级关系,找到可达阵,可证明可达阵的各个列对应的项目类在认知诊断测... 通常认为由属性和项目关联阵(即Q矩阵)的列对应的项目充任认知诊断测验中行为样本,其实这种做法不能有效防止理想反应模式的误判。如在测验之前便可确定欲测之属性及层级关系,找到可达阵,可证明可达阵的各个列对应的项目类在认知诊断测验中必不可少,否则在理想反应模式下就一定有一些被试会被误判。本文给出充分必要Q矩阵的概念,以区别Tatsuoka(1995,2009)讨论过的充分Q矩阵概念。充分必要Q矩阵才能有效指导测验的编制。 展开更多
关键词 测验蓝图 认知诊断 可达矩阵 理想反应模式 计算机化自适应测验
下载PDF
计算机网络实验课程考试系统设计及实现 被引量:10
19
作者 朱小明 张弘 +1 位作者 王兵 杨续业 《实验技术与管理》 CAS 北大核心 2013年第1期101-104,共4页
基于计算机技术、网络技术和多媒体技术的相关理论,介绍了一个专用的考试系统———计算机网络考试系统。该系统主要应用于计算机网络课程的在线考试,其有别于其他的考试系统,主要体现在以下几方面:有独立的知识体系,涵盖面广,考试系统... 基于计算机技术、网络技术和多媒体技术的相关理论,介绍了一个专用的考试系统———计算机网络考试系统。该系统主要应用于计算机网络课程的在线考试,其有别于其他的考试系统,主要体现在以下几方面:有独立的知识体系,涵盖面广,考试系统可以在不同的操作系统下运行。 展开更多
关键词 考试系统 计算机化自适应测试 题库 计算机网络 交换机 路由器
下载PDF
等级反应模型下计算机化自适应测验选题策略 被引量:38
20
作者 陈平 丁树良 +1 位作者 林海菁 周婕 《心理学报》 CSSCI CSCD 北大核心 2006年第3期461-467,共7页
计算机化自适应测验(CAT)中的选题策略,一直是国内外相关学者关注的问题。然而对多级评分的CAT的选题策略的研究却很少报导。本研究采用计算机模拟程序对等级反应模型(G raded Response Model)下CAT的四种选题策略进行研究。研究表明:... 计算机化自适应测验(CAT)中的选题策略,一直是国内外相关学者关注的问题。然而对多级评分的CAT的选题策略的研究却很少报导。本研究采用计算机模拟程序对等级反应模型(G raded Response Model)下CAT的四种选题策略进行研究。研究表明:等级难度值与当前能力估计值匹配选题策略的综合评价最高;在选题策略中增设“影子题库”可以明显提高项目调用的均匀性;并且不同的项目参数分布或不同的能力估计方法都对CAT评价指标有影响。 展开更多
关键词 等级反应模型 计算机化自适应测验 选题策略 影子题库
下载PDF
上一页 1 2 16 下一页 到第
使用帮助 返回顶部