期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Self-centering seismic retrofit scheme for reinforced concrete frame structures:SDOF system study 被引量:5
1
作者 Yunfeng Zhang and Xiaobin Hu Department of Civil and Environmental Engineering,University of Maryland,College Park,MD 20742,USA 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第2期271-283,共13页
This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and min... This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake. 展开更多
关键词 EARTHQUAKE reinforced concrete frame structure nonlinear analysis SDOF system seismic retrofit SELF-CENTERING
下载PDF
Seismic Performances of Large-Span Prestressed Concrete Frame Structure by Shaking Table Tests
2
作者 WEI Wenhui ZHANG Hui LI Zongsen 《Wuhan University Journal of Natural Sciences》 CAS 2012年第3期261-267,共7页
The seismic performances of the large-span prestressed concrete frame structure of bunker bay of thermal power plant under different intensity level was investigated by shaking table tests.A 1/8 microconcrete nonfull ... The seismic performances of the large-span prestressed concrete frame structure of bunker bay of thermal power plant under different intensity level was investigated by shaking table tests.A 1/8 microconcrete nonfull weight scaled model was designed according to the prototype structure and the conditions of laboratory.Three kinds of scaled ground motion accelerations were employed as seismic excitations.White noise was input in the structure through each seismic wave applied.The experimental results indicate that the structure is safe to endure seven degree intensity as required in Chinese codes.The natural vibration frequency of the structure is decreasing with the increasing of the seismic intensity,the natural vibration frequency of the structure decreases by about 24.5%,and the structural stiffness reduces by nearly 44% in seven degree intensity of seldom occurred earthquake.The damage at the top of column in the first floor is the most serious,the weak part of the structure is at the first floor,and the strong beam/weak column phenomenon appeared obviously,so this kind of large-span prestressed concrete frame should not be used in a high intensity district. 展开更多
关键词 prestressed concrete frame structure shaking tabletest seismic performance
原文传递
Research on the direct damage-based seismic design method of RC frame structures
3
作者 Lanfang LUO Jing XU 《International Journal of Technology Management》 2013年第2期65-67,共3页
Based on the existing research, this paper presents an innovative methodology to realize direct damage-based seismic design for RC frame structures by mobilizing ESDOF theory and the damage-based strength reduction fa... Based on the existing research, this paper presents an innovative methodology to realize direct damage-based seismic design for RC frame structures by mobilizing ESDOF theory and the damage-based strength reduction factor(RD factor). A design example is then followed to verify this method. 展开更多
关键词 Reinforced concrete frame structures Direct damage-based seismic design Damage-based inelastic response spectrum
下载PDF
Influence of the column-to-beam flexural strength ratio on the failure mode of beam-column connections in RC frames 被引量:1
4
作者 Gong Maosheng Zuo Zhanxuan +2 位作者 Sun Jing He Riteng Zhao Yinan 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第2期441-452,共12页
The column-to-beam flexural strength ratio(CBFSR)has been used in many seismic codes to achieve the strong column-weak beam(SCWB)failure mode in reinforced concrete(RC)frames,in which plastic hinges appear earlier in ... The column-to-beam flexural strength ratio(CBFSR)has been used in many seismic codes to achieve the strong column-weak beam(SCWB)failure mode in reinforced concrete(RC)frames,in which plastic hinges appear earlier in beams than in columns.However,seismic investigations show that the required limit of CBFSR in seismic codes usually cannot achieve the SCWB failure mode under strong earthquakes.This study investigates the failure modes of RC frames with different CBFSRs.Nine typical three-story RC frame models with different CBFSRs are designed in accordance with Chinese seismic codes.The seismic responses and failure modes of the frames are investigated through time-history analyses using 100 ground motion records.The results show that the required limit of the CBFSR that guarantees the SCWB failure mode depends on the beam-column connection type and the seismic intensity,and different types of beam-column connections exhibit different failure modes even though they are designed with the same CBFSR.Recommended CBFSRs are proposed for achieving the designed SCWB failure mode for different types of connections in RC frames under different seismic intensities.These results may provide some reference for further revisions of the SCWB design criterion in Chinese seismic codes. 展开更多
关键词 strong column-weak beam column-to-beam flexural strength ratio reinforced concrete frame structure beam-column connection failure mode
下载PDF
Realization of the global yield mechanism of RC frame structures by redesigning the columns using column tree method 被引量:2
5
作者 BAI JiuLin OU JinPing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2015年第10期1627-1637,共11页
Global failure mechanism, i.e., the strong-column weak-beam mechanism, can provide higher total energy dissipation capacity with less ductility demand on components than other failure modes, and results in a more unif... Global failure mechanism, i.e., the strong-column weak-beam mechanism, can provide higher total energy dissipation capacity with less ductility demand on components than other failure modes, and results in a more uniform story drift distribution and higher resistance to earthquake loads at the system level. However, the current code-based elastic design method cannot guarantee the global failure mechanism of frame structures under severe earthquakes. In this paper, a simple, but practical design procedure is proposed to ensure the global failure mechanism of reinforced concrete(RC) frame structures by redesigning the columns using the column tree method(CTM). CTM considers the yield limit state of all beams and column bases. The code-based design is firstly carried out to determine the section information of all beams and base columns. Then, the internal force demands applied on the column tree can be derived. Lastly, the column moments, shear forces and axial forces are determined according to the free-body diagram of CTM to finish the column redesign. Two RC frame structures with 6 and 12 stories are illustrated to verify the design procedure. The analytical results demonstrate the proposed approach can realize the global failure mechanism. 展开更多
关键词 global failure mechanism column tree method (CTM) reinforced concrete frame structures failure mode plastic hinges
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部