Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us...Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections.展开更多
Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular c...Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections.展开更多
A 9-story concrete-filled steel tubular frame model is used to analyze the response of joints due to sudden column loss. Three different models are developed and compared to study the efficiency and feasibility of sim...A 9-story concrete-filled steel tubular frame model is used to analyze the response of joints due to sudden column loss. Three different models are developed and compared to study the efficiency and feasibility of simulation, which include substructure model, beam element model and solid element model. The comparison results show that the substructure model has a satisfying capability, calculation efficiency and accuracy to predict the concerned joints as well as the overall framework. Based on the substructure model and a kind of semi-rigid connection for concretefilled square hollow section steel column proposed in this paper, the nonlinear dynamic analyses are conducted by the alternate path method. It is found that the removal of the ground inner column brings high-level joint moments and comparatively low-level axial tension forces. The initial stiffness and transmitted ultimate moment of the semi-rigid connection are the main factors that influence the frame behavior, and their lower limit should be guaranteed to resist collapse. Reduced ultimate moment results in drastic displacement and axial force development, which may bring progressive collapse. The higher initial stiffness ensures that the structure has a stronger capacity to resist progressive collapse.展开更多
A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concre...A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concrete (RC) at the ends of columns andwelding steel plates at the ends of beams was presented. Based on the current design specifications, one half scaled models of 4lateral joints in composite frame consisting of CFSST columns and steel beams were designed and manufactured. One model wasoriginal control specimen, one was strengthened by enclosed RC, and the others were strengthened after pre-damage. The destructiontests under lateral cyclic load on the models were carried. The effectiveness of seismic-damaged joints strengthened with enclosedRC and the reinforcement effect on different levels of seismic damage were studied. The test results show that seismic- damagedjoints in composite frame consisting of CFSST columns and steel beams strengthened with enclosed RC meets the strongcolumn-weak beam joints requirement of seismic design, and the failure modes are of all joints are the bending failure of steel beam.The reinforcement with enclosed RC has a significant on increasing the ultimate capacity and the seismic behaviors of joints. Thestudy indicated the rehabilitated joints recover the level of their original seismic performances before seismic damage in a certainextent damage level. Based on the test data, namely the ultimate capacity, limit displacement, ductility, the energy consumptioncoefficient, limit displacementthe strengthening method of seismic-damaged joints by strengthened with enclosed RC is an effectivemethod for seismic strengthening.展开更多
基金Supported by National Natural Science Foundation of China(No.51268054)Natural Science Foundation of Tianjin(No.13JCQNJC07300)the foundation of Key Laboratory of Coast Civil Structure Safety(Tianjin University),Ministry of Education of China(No.2011-1)
文摘Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections.
基金Supported by the National Natural Science Foundation of China(No.51268054 and No.51468061)the Natural Science Foundation of Tianjin(No.13JCQNJC07300)Foundation of Xinjiang University(No.XY110137)
文摘Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections.
基金Supported by National Natural Science Foundation of China (No.50878066)Natural Science Foundation of Heilongjiang Province (No.ZJG0701)Heilongjiang Postdoctoral Science Foundation
文摘A 9-story concrete-filled steel tubular frame model is used to analyze the response of joints due to sudden column loss. Three different models are developed and compared to study the efficiency and feasibility of simulation, which include substructure model, beam element model and solid element model. The comparison results show that the substructure model has a satisfying capability, calculation efficiency and accuracy to predict the concerned joints as well as the overall framework. Based on the substructure model and a kind of semi-rigid connection for concretefilled square hollow section steel column proposed in this paper, the nonlinear dynamic analyses are conducted by the alternate path method. It is found that the removal of the ground inner column brings high-level joint moments and comparatively low-level axial tension forces. The initial stiffness and transmitted ultimate moment of the semi-rigid connection are the main factors that influence the frame behavior, and their lower limit should be guaranteed to resist collapse. Reduced ultimate moment results in drastic displacement and axial force development, which may bring progressive collapse. The higher initial stiffness ensures that the structure has a stronger capacity to resist progressive collapse.
文摘A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concrete (RC) at the ends of columns andwelding steel plates at the ends of beams was presented. Based on the current design specifications, one half scaled models of 4lateral joints in composite frame consisting of CFSST columns and steel beams were designed and manufactured. One model wasoriginal control specimen, one was strengthened by enclosed RC, and the others were strengthened after pre-damage. The destructiontests under lateral cyclic load on the models were carried. The effectiveness of seismic-damaged joints strengthened with enclosedRC and the reinforcement effect on different levels of seismic damage were studied. The test results show that seismic- damagedjoints in composite frame consisting of CFSST columns and steel beams strengthened with enclosed RC meets the strongcolumn-weak beam joints requirement of seismic design, and the failure modes are of all joints are the bending failure of steel beam.The reinforcement with enclosed RC has a significant on increasing the ultimate capacity and the seismic behaviors of joints. Thestudy indicated the rehabilitated joints recover the level of their original seismic performances before seismic damage in a certainextent damage level. Based on the test data, namely the ultimate capacity, limit displacement, ductility, the energy consumptioncoefficient, limit displacementthe strengthening method of seismic-damaged joints by strengthened with enclosed RC is an effectivemethod for seismic strengthening.