The influence of phase-change coefficients variations in the Singhal cavitation model on the calculation results has been numerically studied. By comparing the numerical results and experimental data, the relationship...The influence of phase-change coefficients variations in the Singhal cavitation model on the calculation results has been numerically studied. By comparing the numerical results and experimental data, the relationship between the coefficients and cavitation numbers is obtained. The calculation results of 2d axisymmetrical cylinder with 45-degree cone cavitator show that under different cavitation numbers, there are three typical kind of cavities, which are respectively main cavity, secondary cavity and rear cavity. The coefficients variations have a great influence respectively on the three type cavities in shape, collapse position, collapse strength, etc, and different cavitation numbers are corresponding to different phase-change coefficients. The cavitation flow field can be divided into three typical zones according to the cavitation number: weak-cavitation zone, secondary-cavitation zone and supercavitation zone. For 45-degree cone cavitator cylinder, the evaporation coefficients will firstly decrease and then increase with the decrease of cavitation numbers in secondary-cavitation zone, while the condensation coefficients keep relatively lower and almost unchanged. In weak-cavitation zone, there only exists the smaller main cavity attached to the model head or there is no obvious cavity. In supercavitation zone, the secondary cavity attached to the model will fall off and merge into the new rear cavity.展开更多
TO develop an excellent heat transfer element under the vacuum condition, experiments about the heat transfer performance of horizontal tube bundles of different materials under various vacuum conditions were carried ...TO develop an excellent heat transfer element under the vacuum condition, experiments about the heat transfer performance of horizontal tube bundles of different materials under various vacuum conditions were carried out, including the stainless steel tube, the brass tube, the Ni-based implanted steel tube and the ion implanted brass tube. The relative trends show that the condensation heat transfer coefficient and the overall heat transfer coefficient of bundles of four materials all increase with the vacuum degree, especially, those of the Ni-based implanted steel tube and the ion implanted brass tube. Under a high vacuum condition (0.07 MPa), the condensation heat transfer coefficient of the Ni-based implanted steel tube bundle is about 1.4 times of that of the stainless steel tube bundle, the condensation heat transfer coefficient of the ion implanted brass tube bundle is found to be about 1.3 times of that of the common brass tube bundle. Therefore, according to the condensation heat transfer characteristics studied under high vacuum conditions, it is believed that a dropwise condensation is partly achieved on the surface of these two implanted tube bundles, and the ion implantation is shown to be an effective method to achieve the dropwise condensation. Based on this study, it is believed that the Ni-based steel tube may replace the brass tube, which is more expensive as a heat transfer component.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.51149003)the Fundamental Research Funds for the Central Universities(Grant No.HIT.NSRIF.2013033)
文摘The influence of phase-change coefficients variations in the Singhal cavitation model on the calculation results has been numerically studied. By comparing the numerical results and experimental data, the relationship between the coefficients and cavitation numbers is obtained. The calculation results of 2d axisymmetrical cylinder with 45-degree cone cavitator show that under different cavitation numbers, there are three typical kind of cavities, which are respectively main cavity, secondary cavity and rear cavity. The coefficients variations have a great influence respectively on the three type cavities in shape, collapse position, collapse strength, etc, and different cavitation numbers are corresponding to different phase-change coefficients. The cavitation flow field can be divided into three typical zones according to the cavitation number: weak-cavitation zone, secondary-cavitation zone and supercavitation zone. For 45-degree cone cavitator cylinder, the evaporation coefficients will firstly decrease and then increase with the decrease of cavitation numbers in secondary-cavitation zone, while the condensation coefficients keep relatively lower and almost unchanged. In weak-cavitation zone, there only exists the smaller main cavity attached to the model head or there is no obvious cavity. In supercavitation zone, the secondary cavity attached to the model will fall off and merge into the new rear cavity.
基金the National Key Basic ResearchProgram of China (973 Program, Grant No. 2011CB710702)
文摘TO develop an excellent heat transfer element under the vacuum condition, experiments about the heat transfer performance of horizontal tube bundles of different materials under various vacuum conditions were carried out, including the stainless steel tube, the brass tube, the Ni-based implanted steel tube and the ion implanted brass tube. The relative trends show that the condensation heat transfer coefficient and the overall heat transfer coefficient of bundles of four materials all increase with the vacuum degree, especially, those of the Ni-based implanted steel tube and the ion implanted brass tube. Under a high vacuum condition (0.07 MPa), the condensation heat transfer coefficient of the Ni-based implanted steel tube bundle is about 1.4 times of that of the stainless steel tube bundle, the condensation heat transfer coefficient of the ion implanted brass tube bundle is found to be about 1.3 times of that of the common brass tube bundle. Therefore, according to the condensation heat transfer characteristics studied under high vacuum conditions, it is believed that a dropwise condensation is partly achieved on the surface of these two implanted tube bundles, and the ion implantation is shown to be an effective method to achieve the dropwise condensation. Based on this study, it is believed that the Ni-based steel tube may replace the brass tube, which is more expensive as a heat transfer component.