With Pueraria edulis from different habitats in Yunnan Province,Guangdong Province and Guangxi Zhuang autonomous region as materials,the medicinal materials of P.edulis were extracted by ethanol condensation reflux ex...With Pueraria edulis from different habitats in Yunnan Province,Guangdong Province and Guangxi Zhuang autonomous region as materials,the medicinal materials of P.edulis were extracted by ethanol condensation reflux extraction and ultrasound-assisted extraction,and the effects of different extraction methods the contents of total flavonoids in P.edulis from different areas were compared.The results showed that the best extraction time for P.edulis in Yunnan Province was 20 min,and that for Guangdong and Guangxi Zhuang Autonomous Region was 30 min.The yield of total flavonoids from P.edulis extracted by the condensation reflux extraction method was relatively better.The content of total flavonoids in P.edulis in Yunnan was the highest with an average content of 0.2557%,while the average content of total flavonoids in P.edulis in Guangdong was the lowest with an average content of 0.2108%.展开更多
The Global Navigation Satellite System(GNSS)positioning method has been significantly developed in geodetic surveying.However,the height obtained through GNSS observations is given in a geodetic height system that nee...The Global Navigation Satellite System(GNSS)positioning method has been significantly developed in geodetic surveying.However,the height obtained through GNSS observations is given in a geodetic height system that needs to be converted to orthometric height for engineering applications.Information on geoid height,which can be calculated using the global geopotential mode,is required to convert such GNSS observations into orthometric height.However,its accuracy is still insufficient for most engineering purposes.Therefore,a reliable geoid model is essential,especially in areas growing fast,e.g.,the central part of Java,Indonesia.In this study,we modeled the local geoid model in the central part of Java,Indonesia,using terrestrial-based gravity observations.The Stokes'formula with the second Helmert's condensation method under the Remove-Compute-Restore approach was implemented to model the geoid.The comparison between our best-performing geoid model and GNSS/leveling observations showed that the standard deviation of the geoid height differences was estimated to be 4.4 cm.This geoid result outperformed the commonly adopted global model of EGM2008 with the estimated standard deviation of geoid height differences of 10.7 cm.展开更多
The discretization size is limited by the sampling theorem, and the limit is one half of the wavelength of the highest frequency of the problem. However, one half of the wavelength is an ideal value. In general, the d...The discretization size is limited by the sampling theorem, and the limit is one half of the wavelength of the highest frequency of the problem. However, one half of the wavelength is an ideal value. In general, the discretization size that can ensure the accuracy of the simulation is much smaller than this value in the traditional finite element method. The possible reason of this phenomenon is analyzed in this paper, and an efficient method is given to improve the simulation accuracy.展开更多
With the wide use of light steel structure in industrial buildings, some problems such as air leakage, water dripping and condensation and so forth occur during the construction and operation phases. Through the onsit...With the wide use of light steel structure in industrial buildings, some problems such as air leakage, water dripping and condensation and so forth occur during the construction and operation phases. Through the onsite testing of a winery building in Huailai County, Hebei Province in China, the influence of infiltration on energy consumption in industrial buildings was studied. The pressurization test method and moisture condensation method were used to test the infiltration rates. The results show that the winery building is twice as leaky as normal Chinese buildings and five times as leaky as Canadian buildings. The energy use simulation demonstrates that the reduction of the infiltration rate of the exterior rooms to 1/3 and the interior rooms to 1/2 could help decrease a total energy consumption of approximately 20% and reduce a total energy cost of approximately $ 225000. Therefore, it has a great potential to reduce the energy consumption in this type of buildings. Enforcement of the appropriate design, construction and installation would play a significant role in improving the overall performance of the building.展开更多
基金Supported by Hunan Provincial University Innovation Platform Open Fund Project(19K049)。
文摘With Pueraria edulis from different habitats in Yunnan Province,Guangdong Province and Guangxi Zhuang autonomous region as materials,the medicinal materials of P.edulis were extracted by ethanol condensation reflux extraction and ultrasound-assisted extraction,and the effects of different extraction methods the contents of total flavonoids in P.edulis from different areas were compared.The results showed that the best extraction time for P.edulis in Yunnan Province was 20 min,and that for Guangdong and Guangxi Zhuang Autonomous Region was 30 min.The yield of total flavonoids from P.edulis extracted by the condensation reflux extraction method was relatively better.The content of total flavonoids in P.edulis in Yunnan was the highest with an average content of 0.2557%,while the average content of total flavonoids in P.edulis in Guangdong was the lowest with an average content of 0.2108%.
文摘The Global Navigation Satellite System(GNSS)positioning method has been significantly developed in geodetic surveying.However,the height obtained through GNSS observations is given in a geodetic height system that needs to be converted to orthometric height for engineering applications.Information on geoid height,which can be calculated using the global geopotential mode,is required to convert such GNSS observations into orthometric height.However,its accuracy is still insufficient for most engineering purposes.Therefore,a reliable geoid model is essential,especially in areas growing fast,e.g.,the central part of Java,Indonesia.In this study,we modeled the local geoid model in the central part of Java,Indonesia,using terrestrial-based gravity observations.The Stokes'formula with the second Helmert's condensation method under the Remove-Compute-Restore approach was implemented to model the geoid.The comparison between our best-performing geoid model and GNSS/leveling observations showed that the standard deviation of the geoid height differences was estimated to be 4.4 cm.This geoid result outperformed the commonly adopted global model of EGM2008 with the estimated standard deviation of geoid height differences of 10.7 cm.
文摘The discretization size is limited by the sampling theorem, and the limit is one half of the wavelength of the highest frequency of the problem. However, one half of the wavelength is an ideal value. In general, the discretization size that can ensure the accuracy of the simulation is much smaller than this value in the traditional finite element method. The possible reason of this phenomenon is analyzed in this paper, and an efficient method is given to improve the simulation accuracy.
文摘With the wide use of light steel structure in industrial buildings, some problems such as air leakage, water dripping and condensation and so forth occur during the construction and operation phases. Through the onsite testing of a winery building in Huailai County, Hebei Province in China, the influence of infiltration on energy consumption in industrial buildings was studied. The pressurization test method and moisture condensation method were used to test the infiltration rates. The results show that the winery building is twice as leaky as normal Chinese buildings and five times as leaky as Canadian buildings. The energy use simulation demonstrates that the reduction of the infiltration rate of the exterior rooms to 1/3 and the interior rooms to 1/2 could help decrease a total energy consumption of approximately 20% and reduce a total energy cost of approximately $ 225000. Therefore, it has a great potential to reduce the energy consumption in this type of buildings. Enforcement of the appropriate design, construction and installation would play a significant role in improving the overall performance of the building.