期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Changes in the Vascular Cylinder of Wild Soybean Roots Under Alkaline Stress 被引量:2
1
作者 NIU Lu LU Jing-mei +2 位作者 WU Dong-mei LI Yan GAO Ting-ting 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2014年第10期2164-2169,共6页
Changes in the vascular cylinder of wild soybean (Glycine soja Sieb. et Zucc) roots under alkaline stress were investigated in an experiment that applied 90 mmol L1 alkaline stress for 10 d at the five-trifoliate pl... Changes in the vascular cylinder of wild soybean (Glycine soja Sieb. et Zucc) roots under alkaline stress were investigated in an experiment that applied 90 mmol L1 alkaline stress for 10 d at the five-trifoliate plant growth stage in Huinan County, Jilin Province, China. Root samples were collected and paraffin-cut sections were made, and the root structure was observed under an optical microscope. There were significant changes in the vascular cylinder of G. soja roots under alkaline stress. Root diameter was reduced and the vascular cylinder changed from tetrarch to triarch pattern. Alkaline stress resulted in reduced, diameters of root vessels, and a large amount of residual, alkaline solution was stained cyaneous in vessels. The paratracheal parenchymatous cells of the vessels were large and there was little secondary xylem. Thus, alkaline stress caused structural changes in the vascular cylinder of G. soja. 展开更多
关键词 Glycine soja Sieb. et Zucc alkaline stress anatomical structure tetrarch condition of vascular cylinder triarchcondition of vascular cylinder
下载PDF
DEVELOPMENT OF CALCULATING MODEL APPLICABLE FOR CYLINDER WALL DYNAMIC HEAT TRANSFER
2
作者 ZHONG Minjun SHI Tielin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第1期60-63,共4页
In the calculation of submarine air conditioning load of the early stage, the obtained heat is regarded as cooling load. The confusion of the two words causing the cooling load figured out is abnormally high, and the ... In the calculation of submarine air conditioning load of the early stage, the obtained heat is regarded as cooling load. The confusion of the two words causing the cooling load figured out is abnormally high, and the change of air conditioning cooling load can not be indicated. In accordance with submarine structure and heat transfer characteristics of its inner components, Laplace transformation to heat conduction differential equation of cylinder wall is carried out. The dynamic calculation of submarine conditioning load based on this model is also conducted, and the results of calculation are compared with those of static cooling load calculation. It is concluded that the dynamic cooling load calculation methods can illustrate the change of submarine air conditioning cooling load more accurate than the static one. 展开更多
关键词 cylinder wall Air conditioning Load calculation
下载PDF