Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera...Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.展开更多
The gas-kinetic theory based flux splitting method has been successfully proposed for solving one-and two-dimensional ideal magnetohydrodynamics by Xu et al. [J.Comput.Phys.,1999;2000],respectively.This paper extends ...The gas-kinetic theory based flux splitting method has been successfully proposed for solving one-and two-dimensional ideal magnetohydrodynamics by Xu et al. [J.Comput.Phys.,1999;2000],respectively.This paper extends the kinetic method to solve three-dimensional ideal magnetohydrodynamics equations,where an adaptive parameter 17 is used to control the numerical dissipation in the flux splitting method. Several numerical examples are given to demonstrate that the proposed method can achieve high numerical accuracy and resolve strong discontinuous waves in three dimensional ideal MHD problems.展开更多
Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categor...Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.展开更多
A Fourier pseudospectral-finue difference scheme is proposed for three-dimensional vorticity. equalion with unilalerally periodic boundary. condilion. Thegeneralized stability. and conrergence are analyzed. The nunier...A Fourier pseudospectral-finue difference scheme is proposed for three-dimensional vorticity. equalion with unilalerally periodic boundary. condilion. Thegeneralized stability. and conrergence are analyzed. The nunierical results show. theadvantage of this method.展开更多
This paper is concerned with the general study in the existence,uniqueness and error estimationof finite element solutions for a larger class of 'saddle-point' schemes. The established theory inthe form of Lax...This paper is concerned with the general study in the existence,uniqueness and error estimationof finite element solutions for a larger class of 'saddle-point' schemes. The established theory inthe form of Lax-like equivalency theorem includes Brezzi’s theory that has been treated as a specialcase.Two criteria are presented so as to help the practical verification of S-Babuska condition.展开更多
文摘Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.
基金supported by the National Basic Research Program under the Grant 2005CB321703the National Natural Science Foundation of China(No.10925101 and No.10828101)+4 种基金the Doctoral Program of the Education Ministry of China(No.20070001036)the Program for New Century Excellent Talents in University(No.NCET-07-0022)supported by Hong Kong Research Grant Council 621709National Natural Science Foundation of China(Project No.10928205)National Key Basic Research Program(2009CB724101)
文摘The gas-kinetic theory based flux splitting method has been successfully proposed for solving one-and two-dimensional ideal magnetohydrodynamics by Xu et al. [J.Comput.Phys.,1999;2000],respectively.This paper extends the kinetic method to solve three-dimensional ideal magnetohydrodynamics equations,where an adaptive parameter 17 is used to control the numerical dissipation in the flux splitting method. Several numerical examples are given to demonstrate that the proposed method can achieve high numerical accuracy and resolve strong discontinuous waves in three dimensional ideal MHD problems.
文摘Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.
文摘A Fourier pseudospectral-finue difference scheme is proposed for three-dimensional vorticity. equalion with unilalerally periodic boundary. condilion. Thegeneralized stability. and conrergence are analyzed. The nunierical results show. theadvantage of this method.
文摘This paper is concerned with the general study in the existence,uniqueness and error estimationof finite element solutions for a larger class of 'saddle-point' schemes. The established theory inthe form of Lax-like equivalency theorem includes Brezzi’s theory that has been treated as a specialcase.Two criteria are presented so as to help the practical verification of S-Babuska condition.