期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
The follow-up of 34 children with medulloblastoma who received 3-dimensional conformal radiation therapy
1
作者 Dongfeng He Siheng Ha Changsheng Wang 《The Chinese-German Journal of Clinical Oncology》 CAS 2009年第7期384-387,共4页
Objective:In our investigation,we studied the patients with medulloblastoma who received 3-dimensional conformal radiation therapy(3DCRT) and recorded their effects,side effects and failure reasons.Methods:From August... Objective:In our investigation,we studied the patients with medulloblastoma who received 3-dimensional conformal radiation therapy(3DCRT) and recorded their effects,side effects and failure reasons.Methods:From August 2001 to August 2007,34 children with medulloblastoma were treated in our hospital.The age at diagnosis was 3-16 years old,and the mean age at diagnosis was 9.5 years old.Among all the patients,16 cases were included in the high risk group and 18 cases were included in the low risk group.All the patients were performed total resection or subtotal resection and no patients received radiotherapy or chemotherapy before operation.All patients received 3DCRT within 3 weeks after resection.The dose of 30 Gy were given to the whole brain and whole spine,followed by 20-25 Gy boosted to the posterior brain fossa.The median fraction dose was 180 cGy.Every patient received the chemotherapy scheme of the Lomustine,Cisplatinum and Vincristine.Nobody received intrathecal chemotherapy.The tests of the complete blood count,blood biochemistry,hepatic and renal functions were required before every cycle of chemotherapy.Results:5-year overall survival(OS) and 5-year disease free survival(DFS) were 71% and 62% respectively.The median follow-up time was 36.5 months.The 5-year OS of the high risk group was 71% compared to 62% of the low risk group.There were significant difference between the two groups(P = 0.01).There were 13 failure cases in all the patients.Of these 13 patients,10 were dead and the other 3 were alive with tumor.The complete remission(CR) rate was 70.5% and the partial remission(PR) rate was 14%.Among the failure patients,there were 3 patients(8.8%) with the recurrences located in the brain of cribriform region.The 5-year OS of the patients with preoperative metastases was 12.5%(1/8),and which of the patients with residual tumor volume > 1.5 cm3 was 0%(0/5).Through the statistic analysis,it was found that both whether or not the metastases were found before surgery and residual tumor volume have the significant impacts on the prognosis of the children with medulloblastoma(P < 0.05).The major adverse reactions were hematological toxicity(7/34,20.6%) and gastrointestinal reaction(4/34,11.8%).Conclusion:Through the using of 3DCRT for the children with medulloblastoma,the severe side effects rate was not high.The prognosis of the patients in low risk group was satisfied which was opposite to that of the patients in high risk group.And the patients with residual tumor volume > 1.5 cm3 and preoperative metastases also had poor prognosis.It is needed to pay attention to the possible low dose of the brain of cribriform region. 展开更多
关键词 MEDULLOBLASTOMA 3-dimensional conformal radiation therapy PROGNOSIS adverse radiotherapy reaction
下载PDF
A dosimetric comparative study between conformal and intensity modulated radiation therapy in the treatment of primary nasopharyngeal carcinomas: the Egyptian experience
2
作者 Ehsan G. El-Ghoneimy Mohamed A. Hassan +2 位作者 Mahmoud F. El-Bestar Omar M. Othman Karim N. Mashhour 《The Chinese-German Journal of Clinical Oncology》 CAS 2012年第11期626-631,共6页
Objective: The study is a comparative study, the aim of which is to compare 3D conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) in treating nasopharyngeal carcinomas; dosimetricall... Objective: The study is a comparative study, the aim of which is to compare 3D conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) in treating nasopharyngeal carcinomas; dosimetrically evaluating and comparing both techniques as regard target coverage and doses to organs at risk (OAR). Methods: Twenty patients with nasopharyngeal carcinoma were treated by 3D-CRT technique and another 20 patients were treated by IMRT. A dosimetric comparison was done by performing two plans for the same patient using Eclipse planning system (version 8.6). Results: IMRT had a better tumor coverage and conformity index compared to 3D-CRT plans (P value of 0.001 and 0.004), respectively. As for the dose homogeneity it was also better in the IMRT plans and the reason for this was attributed to the dose inhomogeneity at the photon/electron junction in the 3D-CRT plans (P value 0.032). Also, doses received by the risk structures, particularly parotids, was significantly less in the IMRT plans than those of 3D-CRT (P value 0.001). Conclusion: IMRT technique was clearly able to increase the dose delivery to the target volume, improve conformity and homogeneity index and spare the parotid glands in comparison to 3D-CRT technique. 展开更多
关键词 3D conformal radiation therapy (3D-CRT) intensity-modulated radiotherapy (IMRT) nasopharyngeal carcinoma XEROSTOMIA
下载PDF
Role of radiation therapy in gastric adenocarcinoma 被引量:15
3
作者 Lisa Hazard John O'Connor Courtney Scaife 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第10期1511-1520,共10页
Outcomes in patients with gastric cancer in the United States remain disappointing, with a five-year overall survival rate of approximately 23%. Given high rates of local-regional control following surgery, a strong r... Outcomes in patients with gastric cancer in the United States remain disappointing, with a five-year overall survival rate of approximately 23%. Given high rates of local-regional control following surgery, a strong rationale exists for the use of adjuvant radiation therapy. Randomized trials have shown superior local control with adjuvant radiotherapy and improved overall survival with adjuvant chemoradiation. The benefit of adjuvant chemoradiation in patients who have undergone D2 lymph node dissection by an experienced surgeon is not known, and the benefit of adjuvant radiation therapy in addition to adjuvant chemotherapy continues to be defined. In unresectable disease, chemoradiation allows long-term survival in a small number of patients and provides effective palliation. Most trials show a benefit to combined modality therapy compared to chemotherapy or radiation therapy alone. The use of pre-operative, intra-operative, 3D conformal, and intensity modulated radiation therapy in gastric cancer is promising but requires further study. The current article reviews the role of radiation therapy in the treatment of resectable and unresectable gastric carcinoma, focusing on current recommendations in the United States. 展开更多
关键词 radiation therapy Gastric cancer Stomach cancer CHEMOradiation Adjuvant therapy Neoadjuvant therapy Intra-operative radiation therapy 3D conformal radiation therapy Intensity modulated radiation therapy
下载PDF
Clinical observation of gemcitabine and concomitant three-dimensional conformal radiotherapy in the treatment of locally advanced non-small cell lung cancer 被引量:4
4
作者 Jing Cheng Gang Wu Hongge Wu Jun Xue 《The Chinese-German Journal of Clinical Oncology》 CAS 2008年第6期311-314,共4页
Objective: To evaluate the clinical effect of gemcitabine and concurrent three-dimensional conformal radiation therapy (3D-CRT) for locally advanced non-small cell lung cancer (NSCLC). Methods: From April 2002 t... Objective: To evaluate the clinical effect of gemcitabine and concurrent three-dimensional conformal radiation therapy (3D-CRT) for locally advanced non-small cell lung cancer (NSCLC). Methods: From April 2002 to June 2005, 38 patients with inoperable stage Ⅲ NSCLC were treated with gemcitabine and 3D-CRT simultaneously. Chemotherapy consisted of intravenously gemcitabine 350 mg/m^2 on days 1, 8, 15, 22, 29, 36.3D-CRT was delivered up to a total dose of 60-64 Gy with a 2.0 Gy dose fraction per day, 5 days per week. Results: The overall response rates of primary tumor and mediastinum metastatic node were 86.8% (33/38) and 90.6% (29/32) respectively, and 91.7% (22/24) and 78.6% (11/14) for squamous cell carcinoma and adenocarcinoma respectively. The acute side effects of patients were mostly myelosuppression, nausea, vomiting, radiation-induced esophagitis and pneumonitis (RTOG 1/11), however, all of them were cured. Conclusion: Concurrent application of gemcitabine and 3D-CRT can improve the overall response rate for locally advanced NSCLC without aggravating the side effects. 展开更多
关键词 non-small cell lung cancer three-dimensional conformal radiation therapy CHEMOtherapy concurrent chemoradiotherapy GEMCITABINE
下载PDF
Study of the impact of CT/CT image fusion radiotherapy on V_(20) and radiation pneumonitis of non-small cell lung cancer 被引量:2
5
作者 Liang Liu Jinzhong Zhang +4 位作者 Changhu Li Wei Ge Shunxiang Luo Yu Huang Yongfa Zheng 《The Chinese-German Journal of Clinical Oncology》 CAS 2012年第2期72-75,共4页
Objective:The aim of our study was to investigate the value of CT/CT image fusion radiation treatment planning in non-small cell lung cancer(NSCLC) and the impact on V20 and radiation pneumonitis(RP).Methods:Patients ... Objective:The aim of our study was to investigate the value of CT/CT image fusion radiation treatment planning in non-small cell lung cancer(NSCLC) and the impact on V20 and radiation pneumonitis(RP).Methods:Patients who were pathologically or cytologically diagnosed of stage IIIA and IIIB NSCLC were treated with three-dimensional conformal radiation therapy(4000 cGy).Forty patients got at least 25% tumor reduction were randomly divided into two groups:group A of regular shrink field radiotherapy(20 cases) and group B of CT/CT image fused shrink field radiotherapy(20 cases).Dosage reached 6600 cGy.Clinical data,V20 and RP were observed within 3 months after radiotherapy.Statistical analysis was conducted for the NSCLC patients.Results:22.5%(9/40) patients got RP during follow-up.Group A accounted for 6 cases(30%),and group B had 3 cases(15%).There was no marked difference between the two groups(P = 0.256),univariate analysis revealed that the IV20 of A and B groups,and IV20 and CV20 of all patients were statistically related to the incidence of RP(P < 0.05).With Wilcoxon method assay,the ipsilateral lung V20 and contralateral lung V20 had statistical significance between the two groups(P < 0.05).Conclusion:The CT/CT image infusion treatment planning could increase the radical dosage with better tumor control probability but won't increase adverse reaction. 展开更多
关键词 non-small cell lung cancer three-dimensional conformal radiation therapy radiation pneumonitis CT/CT image fusion V20
下载PDF
Influences of Motion Artifacts on Three-Dimensional Reconstruction Volume and Conformal Radiotherapy Planning 被引量:9
6
作者 ZHANG Shu-xu CHEN Guang-jie +2 位作者 ZHOU Ling-hong YANG Ke-cheng LIN Sheng-qu 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第3期123-130,共8页
Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor al... Objective :To investigate the influences of motion artifacts on three-dimensional (3D) reconstruction volume and conformal radiotherapy planning. Methods: A phantom which can mimic the clip motion of lung tumor along the cranial-caudal direction is constructed by step motor, small ball of polyethylene and potato. Ten different scan protocols were set and CT data of the phantom were acquired by using a commercial GE LightSpeedl6 CT scanner. The 3D reconstruction of the CT data was implemented by adopting volume-rendering technology of GE AdvantageSim 6.0 system. The reconstructed volumes of each target in different scan protocols were measured through 3D measuring tools. Thus, relative deviations of the reconstruction volumes between moving targets and static ones were determined. The three-dimensional conformal radiation therapy (3D- CRT) plans and conformal fields were created and compared for a static/moving target with the WiMRT treatment planning system (TPS). Results:For a static target, there was no obvious difference among the 3D reconstruction volumes when the CT data were acquired with different pitches and slices. The appearance of 3D reconstruction volume and 3D conformal field of a moving target was quite different from that of static one. The maximum relative deviation is nearly 90% for a moving target scanned with different scan protocols. The relative deviations are variable among the different targets, about from -39.8% to 89.5% for a smaller target and from - 18.4% to 20.5% for a larger one. Conclusion :The motion artifacts have great effects on 3 D-CRT planning and reconstruction volume, which will greatly induce distorted conformal radiation fields and false DVHs for a moving target. 展开更多
关键词 motion artifact PHANTOM three-dimensional conformal radiation therapy 3 D-CRT) four-dimensional computed tomography 4 D-CT)
下载PDF
The impact of intensity modulated radiotherapy on the skin dose for deep seated tumors
7
作者 H. S. Abou-Elenein Ehab M. Attalla +3 位作者 Hany Ammar Ismail Eldesoky Mohamed Farouk Shaimaa Shoer 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第4期194-198,共5页
Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate... Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well. 展开更多
关键词 skin dose intensity modulated radiotherapy (IMRT) three-dimensional conformal radiation therapy (3DCRT) thermoluminescent dosimeter (TLD) dose calculation
下载PDF
Comparative study of IORT and 3D-CRT for hepato-cellular carcinoma
8
作者 Lu Jinli Yang Fang Wang Zuoren 《Journal of Medical Colleges of PLA(China)》 CAS 2009年第6期354-359,共6页
Objective: To investigate the feasibility of intra-operative radiation therapy (IORT) in hepato-cellular carcinoma (HCC). Methods: Based on the dosage distribution of tumor and adjacent sensitive organs, and dose-volu... Objective: To investigate the feasibility of intra-operative radiation therapy (IORT) in hepato-cellular carcinoma (HCC). Methods: Based on the dosage distribution of tumor and adjacent sensitive organs, and dose-volume histogram (DVH), Topslane three-dimensional therapy plan was used to compare IORT and three-dimensional conformal radiation therapy (3D-CRT) in 12 cases of HCC. Results: Taking the center of tumors as the isodose center, the V90 (volume of 90% dose distribution) of IORT was significantly better than that of 3D-CRT, and median absorbed doses of normal organs in IORT was significantly lower than that in 3D-CRT. Conclusion: The V90 of IORT is better than that of 3D-CRT in HCC, and neighboring sensitive organs were effectively protected by IORT. The tumors absorbed dose and local control rate are improved in IORT. 展开更多
关键词 Hepato-cellular carcinoma (HCC) Intra-operative radiotherapy Three-dimensional conformal radiation therapy
下载PDF
Dosimetric evaluation of CR, 3DCRT and two types of IMRT for breast cancer after conservative surgery
9
作者 Fuli Zhang Yongqian Zhang Yadi Wang 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第4期153-158,共6页
Objective: The purpose of this study was to compare the dose distribution and dose volume histogram (DVH) of the planning target volume (PTV) and organs at risk (OARs) among conventional radiation therapy (CR), three-... Objective: The purpose of this study was to compare the dose distribution and dose volume histogram (DVH) of the planning target volume (PTV) and organs at risk (OARs) among conventional radiation therapy (CR), three-dimensional conformal radiation therapy (3DCRT), two-step intensity-modulated radiation therapy (TS-IMRT) and direct machine parameter optimization intensity-modulated radiation therapy (DMPO-IMRT) after breast-conserving surgery. Methods: For each of 20 randomly chosen patients, 4 plans were designed using 4 irradiation techniques. The prescribed dose was 50 Gy/2 Gy/25 f, 95% of the planning target volume received this dose. The cumulated DVHs and 3D dose distributions of CR, 3DCRT, TS-IMRT and DMPO-IMRT plans were compared. Results: For the homogeneity indices, no statistically significant difference was observed among CR, 3DCRT, TS-IMRT and DMPO-IMRT while the difference of the conformality indices were statistically significant. With regard to the organs at risk, IMRT and 3DCRT showed a significantly fewer exposure dose to the ipsilateral lung than CR in the high-dose area while in the low-dose area, IMRT demonstrated a significant increase of exposure dose to ipsilateral lung, heart and contralateral breast compared with 3DCRT and CR. In addition, the monitor units (MUs) for DMPO-IMRT were approximately 26% more than those of TS-IMRT and the segments of the former were approximately 24% less than those of the latter. Conclusion: Compared with CR, 3DCRT and IMRT improved the homogeneity and conformity of PTV, reduced the irradiated volume of OARs in high dose area but IMRT increased the irradiated volume of OARs in low dose area. DMPO-IMRT plan has fewer delivery time but more MUs than TS-IMRT. 展开更多
关键词 breast cancer conventional radiation therapy (CR) three-dimensional conformal radiation therapy (3DCRT) two-step intensity-modulated radiation therapy (TS-IMRT) direct machine parameter optimization intensity-modulated radiation therapy (DMPO-IMRT)
下载PDF
Treatment of Non-Small Cell Lung Cancer (NSCLC) Using CT in Combination with a PET Examination to Minimize the Clinical Target Volume of the Mediastinum
10
作者 Yusheng Shi Xiaogang Deng Longhua Chen 《Chinese Journal of Clinical Oncology》 CSCD 2007年第3期189-194,共6页
OBJECTIVE To decrease radiation injury of the esophagus and lungs by utilizing a CT scan in combination with PET tumor imaging in order to minimize the clinical target area of locally advanced non-small cell lung can-... OBJECTIVE To decrease radiation injury of the esophagus and lungs by utilizing a CT scan in combination with PET tumor imaging in order to minimize the clinical target area of locally advanced non-small cell lung can-cer, without preventive radiation on the lymphatic drainage area. METHODS Of 76 patients with locally advanced non-small cell lung cancer (NSCLC), 32 received a PET examination before radiotherapy. Preventive radiation was not conducted in the mediastinum area without lymphatic metastasis, which was confirmed by CT and PET. For the other 44 patients, preventive radiation was performed in the lymphatic drainage area. PET examinations showed that the clinical target volume of the patients was decreased on average to about one third. The radiation therapy for patients of the two groups was the same, i.e. the dose for accelerated fractionated irradiation was 3 Gy/time and 5 time/week. The preventive dose was 42 to 45 Gy/time, 14 to 15 time/week, with 3-week treatment, and the therapeu- tic dose was 60 to 63 Gy/time, 20 to 21 time/week, with a period of 4 to 5 weeks. RESULTS The rate of missed lymph nodes beyond the irradiation field was 6.3% and 4.5% respectively in the group with and without PET exami- nation (P = 0.831). The incidence of acute radioactive esophagitis was 15.6 % and 45.5% in the two groups respectively (P = 0.006). The incidence of acute radiation pneumonia and long-term pulmonary fibrosis in the two groups was 6.3% and 9.1%, and 68.8% and 75.0%, respectively (P = 0.982 and P = 0.547). CONCLUSION The recurrence rate in the lymph nodes beyond the tar-get area was not increased after minimizing the clinical target volume (CTV), whereas radioactive injury to the lungs and esophageal injury was reduced, and especially with a significant decrease in the rate of acute radioactive esophagitis. The method of CT in combination with PET for minimizing the mediastinal CTV is superior to the conventional preventive radiation of the mediastinum. 展开更多
关键词 non-small cell lung cancer three dimentional conformal radiation therapy computerized tomography (CT) positron emission computerized tomographical scanning.
下载PDF
Uncertainties of "in v/vo" Dosimetry Using Semiconductors
11
作者 Zeina Al Kattar Hanna El Balaa Saeed Zahran 《Journal of Life Sciences》 2015年第3期120-126,共7页
The purpose of the present study is to evaluate the uncertainties of in vivo dosimetry measured with diode detectors for conformal radiation therapy techniques in order to define appropriate tolerance levels for pelvi... The purpose of the present study is to evaluate the uncertainties of in vivo dosimetry measured with diode detectors for conformal radiation therapy techniques in order to define appropriate tolerance levels for pelvis and breast treatment in MEIH (Middle East Institute of Health). The present work is carried out on 30-472 and 30-473 diode detectors irradiated by 4 and 15MV photon beams of a medical linear accelerator Synergy from ELEKTA. Dose computation is performed with Pinnacle 7.4 k treatment planning system. First, an estimation of the uncertainties in a simple geometric case, using a water-equivalent solid phantom is done. Secondly, each treatment parameter such as field size, beam angle, beam modifiers and source-skin distance is evaluated in order to simulate the conformal radiation treatments used in the present institution for the main anatomical sites. Interpretation of entrance dose in-vivo measurements requires the determination of appropriate tolerance levels. Indeed, the authors found that the 5% action level proposed in the literature underestimates the uncertainties in the treatment process. A method for the evaluation of tolerance/action levels related to the different anatomical sites is developed. By the end of the present study the authors have developed an integrated monitoring system that offers accurate information about the dose received by patients. 展开更多
关键词 In vivo dosimetry conformal radiation therapy entrance dose diode detectors UNCERTAINTIES tolerance levels integratedsystem.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部