A new experiment was made on the developing of bed separations and mining subsidence from Tangshan T2192 working face by equivalent materials simulation.The overburden deformation and the developing of bed separations...A new experiment was made on the developing of bed separations and mining subsidence from Tangshan T2192 working face by equivalent materials simulation.The overburden deformation and the developing of bed separations with working face advanc- ing was simulated by a new model.The results show that the maximum value of bed separations moved forward gradually along with the working face advancing;the maxi- mum value of bed separations is 0.31~0.50 times of mining thickness.The key strata have a great influence upon surface subsidence during the overburden movement process.The mechanics parameters of new experiment are fitted with results in fields perfectly.展开更多
Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single co...Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single coil VAV AC system,conventional proportional-integral(PI)control algorithm is usually adopted to track the set-points of the room temperature and humidity by regulating the supply air flow rate and the chilled water flow rate,respectively.However,the control performance is usually not good due to the high coupling of the heat and mass transfer in the air-handling unit(AHU).A model-based control method is developed to realize the decoupling control of the room temperature and humidity according to the bilinear characteristics of the temperature and humidity variation.In this control method,a bilinear room temperature controller is used to track the room temperature set-point based on the real-time cooling load,while a room humidity controller is used to track the room humidity set-point depending on the real-time humidity load.The control performance was validated in a simulated VAV AC system.The test results show that comparing with the conventional PI control,the room temperature and humidity are controlled much more robustly and accurately by using the proposed model-based control method.展开更多
基金The National Natural Science Funds Committee(50174035)
文摘A new experiment was made on the developing of bed separations and mining subsidence from Tangshan T2192 working face by equivalent materials simulation.The overburden deformation and the developing of bed separations with working face advanc- ing was simulated by a new model.The results show that the maximum value of bed separations moved forward gradually along with the working face advancing;the maxi- mum value of bed separations is 0.31~0.50 times of mining thickness.The key strata have a great influence upon surface subsidence during the overburden movement process.The mechanics parameters of new experiment are fitted with results in fields perfectly.
基金This work presented in this paper is financially supported by a grant(No.51678263)of National Science Foundation of China.
文摘Variable air volume(VAV)air-conditioning(AC)systems are widely employed to achieve a comfortable room thermal and humid environment depending on its better regulation performance and energy efficiency.In the single coil VAV AC system,conventional proportional-integral(PI)control algorithm is usually adopted to track the set-points of the room temperature and humidity by regulating the supply air flow rate and the chilled water flow rate,respectively.However,the control performance is usually not good due to the high coupling of the heat and mass transfer in the air-handling unit(AHU).A model-based control method is developed to realize the decoupling control of the room temperature and humidity according to the bilinear characteristics of the temperature and humidity variation.In this control method,a bilinear room temperature controller is used to track the room temperature set-point based on the real-time cooling load,while a room humidity controller is used to track the room humidity set-point depending on the real-time humidity load.The control performance was validated in a simulated VAV AC system.The test results show that comparing with the conventional PI control,the room temperature and humidity are controlled much more robustly and accurately by using the proposed model-based control method.