期刊文献+
共找到92篇文章
< 1 2 5 >
每页显示 20 50 100
Weld formation and heating mechanism in ultra-narrow gap withconstricted arc by ultra-fine granular flux 被引量:6
1
作者 郑韶先 李小雷 +1 位作者 车军 李德福 《China Welding》 EI CAS 2012年第1期39-43,共5页
Ultra-narrow gap welding (UNGW) process with high stabilization, reliability and without spatter can be achieved with constricted arc by molten slag wall, which is made from melted flux. The experiments are carried ... Ultra-narrow gap welding (UNGW) process with high stabilization, reliability and without spatter can be achieved with constricted arc by molten slag wall, which is made from melted flux. The experiments are carried out by changing voltage under different currents. The results indicate voltage range being fit for UNGW is about 22 -31 V under the current range of 200 -320 A. With the increasing of voltage, weld formation of UNGW has the law of lack of fusion on sidewall, good weld and undercut in turn under a certain current. In addition, the action relationships among arc, molten slag wall and sidewalls can be improved by properly adjusting voltage and current of arc, which makes cathode spot properly distribute in ultra-narrow gap. Therefore, the effective control of weld formation of UNGW has been achieved. 展开更多
关键词 ultra-fine granular flux constricted arc ultra-narrow gap welding weld formation
下载PDF
Nuclear mechanics during constricted migration 被引量:2
2
作者 Yuntao Xia Charlotte R. Pfeifer Dennis E. Discher 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2019年第2期299-308,共10页
Cell migration through narrow interstitial space in tissues is commonly seen in both physiological and pathological conditions. For example, immune cells have to squeeze through vasculature and extracellular matrix to... Cell migration through narrow interstitial space in tissues is commonly seen in both physiological and pathological conditions. For example, immune cells have to squeeze through vasculature and extracellular matrix to reach the wound or diseased sites, and similarly cancer cells need to crawl through porous space in tissues to invade surrounding tumor-free regions. Therefore, the bulky stiff nucleus in the cell becomes a barrier during constricted migration making such process pore-size dependent with smaller pores exponentially alleviate the passage capability. However, in some cases, cells can actively deform their nuclei to squeeze through constrictions although some price needs to be paid. In this review, we focus on:(1) nuclear structures and morphological regulations,(2) proposed mechanisms that drive constricted migration,(3) short-term consequences such as nuclear envelope (NE) rupture and DNA damage during such process,(4) biophysical factors that facilitate NE rupture, and (5) long term consequences such as genomic variation caused by repetitive NE rupture. Both experimental results and modeling are provided with the intention to better understand the constricted migration. 展开更多
关键词 constricted MIGRATION NUCLEAR ENVELOPE RUPTURE DNA DAMAGE
下载PDF
Influence of magnetically constricted arc traverse speed (MCATS) on tensile properties and microstructural characteristics of welded Inconel 718 alloy sheets 被引量:1
3
作者 Tushar Sonar Visvalingam Balasubramanian +2 位作者 Sudersanan Malarvizhi Thiruvenkatam Venkateswaran Dhenuvakonda Sivakumar 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2021年第4期1395-1413,共19页
The magnetically constricted arc technique was implemented to mitigate the heat input related metallurgical problems in Gas Tungsten Arc Welding(GTAW)of Inconel 718 alloy particularly Nb segregation and subsequent lav... The magnetically constricted arc technique was implemented to mitigate the heat input related metallurgical problems in Gas Tungsten Arc Welding(GTAW)of Inconel 718 alloy particularly Nb segregation and subsequent laves phase evolution in fusion zone.This paper reports the direct effect of magnetically constricted arc traverse speed(MCATS)on bead profile,tensile properties and microstructural evolution of Inconel 718 alloy sheets joined by Gas Tungsten Constricted Arc Welding(GTCAW)process.The mechanism amenable for the microstructural modification and corresponding influence on the tensile properties of joints is investigated both in qualitative and quantitative manner related to the mechanics of arc constriction and pulsing.It is correlated to the solidification conditions during welding.The relationship between MCATS and Arc Constriction Current(ACC)was derived.Its interaction effect on the magnetic arc constriction and joint performance was analysed.Results showed that the joints fabricated using CATS of 70 mm/min exhibited superior tensile properties(98.39% of base metal strength with 31.50% elongation).It is attributed to the grain refinement in fusion zone microstructure leading to the evolution of finer,discrete laves phase in interdendritic areas. 展开更多
关键词 GTCA welding Inconel 718 alloy Magnetically constricted arc traverse speed Tensile properties Microstructure Laves phase
下载PDF
Transition from Spark Discharge to Constricted Glow Discharge in Atmospheric Air by Capacitor Coupled Discharge
4
作者 张禹涛 任春生 +4 位作者 徐振峰 马腾才 齐冰 王德真 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第5期591-595,共5页
The transition from a spark discharge to a constricted glow discharge in atmospheric air was studied with a capacitor coupled pin-to-water plasma reactor. The reason of the transition is considered to be of various fa... The transition from a spark discharge to a constricted glow discharge in atmospheric air was studied with a capacitor coupled pin-to-water plasma reactor. The reason of the transition is considered to be of various factors, namely the change of the air gap due to the polarization of water molecules by the electric field, the feedback effect of the capacitors, and the ion trapping mechanism. The effects of the frequency of the power supply, inter-electrode gap, and coupled capacitance on the discharge transition were also investigated. 展开更多
关键词 air plasma atmospheric pressure constricted glow discharge
下载PDF
Numerical Investigation of the Pulsatile Flow of Viscous Fluid in Constricted Wall Channel with Thermal Radiation
5
作者 Amjad Ali Zainab Bukhari +1 位作者 Hamayun Farooq Zaheer Abbas 《Advances in Applied Mathematics and Mechanics》 SCIE 2023年第4期1001-1022,共22页
The main theme of the current article is to investigate the heat transfer in the pulsatile flow of an electrically conducting viscous fluid in a constricted channel under the effect of the magnetic field and thermal r... The main theme of the current article is to investigate the heat transfer in the pulsatile flow of an electrically conducting viscous fluid in a constricted channel under the effect of the magnetic field and thermal radiation.The unsteady governing equations simplified for low conducting fluids are solved numerically by finite difference method using stream-vorticity function formulation.The influence of the flow parameters such as the Hartmann number(magnetic parameter),Strouhal number(flow pulsation parameter),Prandtl number,and radiation parameter is studied on the relevant flow profiles.The influence of different emerging parameters on the skin friction coefficient and Nusselt number are examined,as well.In general,the profiles are observed to exhibit a relatively more regular pattern upstream of the construction than that downstream of the constriction. 展开更多
关键词 constricted channel pulsatileflow thermal radiation magneticfield Strouhal number Prandtl number
原文传递
Neuralgic amyotrophy with hourglass-like constrictions:A case report
6
作者 Mi-Hyeon Bang Ha-Lim Song +2 位作者 Seok Hahn Wanil Kim Hwan-Kwon Do 《World Journal of Clinical Cases》 SCIE 2024年第34期6728-6735,共8页
BACKGROUND Neuralgic amyotrophy(NA)is a rare disease with sudden upper limb pain followed by affected muscle weakness.The most commonly affected area in NA is the upper part of the brachial plexus,and the paraspinal m... BACKGROUND Neuralgic amyotrophy(NA)is a rare disease with sudden upper limb pain followed by affected muscle weakness.The most commonly affected area in NA is the upper part of the brachial plexus,and the paraspinal muscles are rarely affected(1.5%),making these cases difficult to distinguish from cervical radiculopathy.CASE SUMMARY A 76-year-old male presented to the emergency department with left hip pain post-fall.After undergoing left femoral neck fracture surgery,he experienced sudden left shoulder pain for 10 days with subsequent left arm weakness.Cervical spine computed tomography revealed mild right asymmetric intervertebral disc bulging with a decreased C5-6disc space.Three weeks later,an electrodiagnostic study confirmed brachial plexopathy findings involving the cervical root.Magnetic resonance neurography was performed for a differential diagnosis.Contrast enhancement was identified at the upper trunk of the brachial plexus,including the C5 nerve root.A suprascapular nerve hourglass-like focal constriction(HLFC)was also identified,confirming NA.After being diagnosed with NA,the patient received 15 mg prednisolone,twice daily,for 3 weeks.Physical therapy was initiated,including left arm strengthening exercises and electrical stimulation therapy.Left shoulder muscle strength significantly improved one CONCLUSION NA's unique features like HLFC and paraspinal involvement are crucial for accurate diagnosis,avoiding confusion with cervical radiculopathy. 展开更多
关键词 Neuralgic amyotrophy Cervical radiculopathy Hourglass-like focal constriction Paraspinal muscle Magnetic resonance neurography Case report
下载PDF
Life-threatening constrictive pericarditis accompanied by synthetic cannabinoid use:A case report and literature review
7
作者 Mahsa Behnemoon Razieh Omidvar +2 位作者 Zeinab Sadat Fattah Jahromi Alireza Salmanipour Erfan Kohansal 《Journal of Acute Disease》 2024年第3期116-120,共5页
Rationale:Synthetic cannabinoids are increasingly used as recreational drugs and have been associated with adverse cardiovascular effects.However,reports of synthetic cannabinoids accompanied by constrictive pericardi... Rationale:Synthetic cannabinoids are increasingly used as recreational drugs and have been associated with adverse cardiovascular effects.However,reports of synthetic cannabinoids accompanied by constrictive pericarditis are limited.Patient’s concern:A 28-year-old male with a history of synthetic cannabinoid(Bonzai)abuse presented with chest discomfort,dyspnea,and lower extremity edema.Investigations revealed reduced left ventricular ejection fraction,elevated inflammatory markers,low electrocardiogram voltages,and atrial fibrillation.Diagnosis:Chest spiral computerized tomography scan and chest X-ray demonstrated pericardial calcification.Cardiac magnetic resonance imaging and right heart catheterization were done to confirm the possibility of constrictive pericarditis.Based on the patient’s addiction history and exclusion of rheumatologic and infectious causes,it was supposed that constrictive pericarditis and cardiomyopathy may be accompanied by synthetic cannabinoid use.Interventions:The patient received standard medical therapy,including loop diuretics for cardiomyopathy and constrictive pericarditis.Catheter ablation was recommended for his rhythm control,and he was planned for close monitoring of clinical and echocardiographic response and evaluation of the need for surgical pericardiectomy in the future.Outcomes:After 6 months follow-up,echocardiographic exam revealed no significant improvement in ventricular function.However,due to the high surgical risk,the patient’s poor compliance,and the continuation of drug abuse,he was not a good candidate for surgery according to our heart team’s decision.Lessons:Synthetic cannabinoids can trigger constrictive pericarditis,and clinicians should consider them when evaluating patients with compatible symptoms and exposure history.Further research on the cardiovascular effects of synthetic cannabinoids is needed and public education on potential harms is warranted. 展开更多
关键词 Bonzai Constrictive pericarditis Synthetic cannabinoids CARDIOMYOPATHY MYOCARDITIS
下载PDF
Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures
8
作者 Chee Lim Jonathan Ng +4 位作者 Babak Sarraf Rhys Vaughan Marios Efthymiou Leonardo Zorron Cheng Tao Pu Sujievvan Chandran 《World Journal of Transplantation》 2024年第2期88-98,共11页
BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on s... BACKGROUND Endoscopic management is the first-line therapy for post-liver-transplant anas-tomotic strictures.Although the optimal duration of treatment with plastic stents has been reported to be 8-12 months,data on safety and duration for metal stents in this setting is scarce.Due to limited access to endoscopic retrograde cholan-giopancreatography(ERCP)during the coronavirus disease 2019 pandemic in our centre,there was a change in practice towards increased usage and length-of-stay of the Kaffes biliary intraductal self-expanding stent in patients with suitable anatomy.This was mainly due to the theoretical benefit of Kaffes stents allowing for longer indwelling periods compared to the traditional plastic stents.METHODS Adult liver transplant recipients aged 18 years and above who underwent ERCP were retrospectively identified during a 10-year period through a database query.Unplanned admissions post-Kaffes stent insertion were identified manually through electronic and scanned medical records.The main outcome was the incidence of complications when stents were left indwelling for 3 months vs 6 months.Stent efficacy was calculated via rates of stricture recurrence between patients that had stenting courses for≤120 d or>120 d.RESULTS During the study period,a total of 66 ERCPs with Kaffes insertion were performed in 54 patients throughout their stenting course.In 33 ERCPs,the stent was removed or exchanged on a 3-month interval.No pancreatitis,perfor-ations or deaths occurred.Minor post-ERCP complications were similar between the 3-month(abdominal pain and intraductal migration)and 6-month(abdominal pain,septic shower and embedded stent)groups-6.1%vs 9.1%respectively,P=0.40.All strictures resolved at the end of the stenting course,but the stenting course was variable from 3 to 22 months.The recurrence rate for stenting courses lasting for up to 120 d was 71.4%and 21.4%for stenting courses of 121 d or over(P=0.03).There were 28 patients that were treated with a single ERCP with Kaffes,21 with removal after 120 d and 7 within 120 d.There was a significant improvement in stricture recurrence when the Kaffes was removed after 120 d when a single ERCP was used for the entire stenting course(71.0%vs 10.0%,P=0.01).CONCLUSION Utilising a single Kaffes intraductal fully-covered metal stent for at least 4 months is safe and efficacious for the management of post-transplant anastomotic strictures. 展开更多
关键词 Liver transplantation CHOLANGIOPANCREATOGRAPHY Endoscopic retrograde CONSTRICTION PATHOLOGIC Self expandable metallic stents Bile duct diseases CHOLESTASIS
下载PDF
A Lattice Boltzmann and Immersed Boundary Scheme for Model Blood Flow in Constricted Pipes:Part 2-Pulsatile Flow
9
作者 S.C.Fu R.M.C.So W.W.F.Leung 《Communications in Computational Physics》 SCIE 2013年第6期153-173,共21页
One viable approach to the study of haemodynamics is to numerically model this flow behavior in normal and stenosed arteries.The blood is either treated as Newtonian or non-Newtonian fluid and the flow is assumed to b... One viable approach to the study of haemodynamics is to numerically model this flow behavior in normal and stenosed arteries.The blood is either treated as Newtonian or non-Newtonian fluid and the flow is assumed to be pulsating,while the arteries can be modeled by constricted tubes with rigid or elastic wall.Such a task involves formulation and development of a numerical method that could at least handle pulsating flow of Newtonian and non-Newtonian fluid through tubes with and without constrictions where the boundary is assumed to be inelastic or elastic.As a first attempt,the present paper explores and develops a time-accurate finite difference lattice Boltzmann method(FDLBM)equipped with an immersed boundary(IB)scheme to simulate pulsating flow in constricted tube with rigid walls at different Reynolds numbers.The unsteady flow simulations using a time-accurate FDLBM/IB numerical scheme is validated against theoretical solutions and other known numerical data.In the process,the performance of the time-accurate FDLBM/IB for a model blood flow problem and the ease with which the no-slip boundary condition can be correctly implemented is successfully demonstrated. 展开更多
关键词 Finite difference method lattice Boltzmann method immersed boundary method blood flow constricted pipe
原文传递
A Lattice Boltzmann and Immersed Boundary Scheme for Model Blood Flow in Constricted Pipes:Part 1-Steady Flow
10
作者 S.C.Fu W.W.F.Leung R.M.C.So 《Communications in Computational Physics》 SCIE 2013年第6期126-152,共27页
Hemodynamics is a complex problem with several distinct characteristics;fluid is non-Newtonian,flow is pulsatile in nature,flow is three-dimensional due to cholesterol/plague built up,and blood vessel wall is elastic.... Hemodynamics is a complex problem with several distinct characteristics;fluid is non-Newtonian,flow is pulsatile in nature,flow is three-dimensional due to cholesterol/plague built up,and blood vessel wall is elastic.In order to simulate this type of flows accurately,any proposed numerical scheme has to be able to replicate these characteristics correctly,efficiently,as well as individually and collectively.Since the equations of the finite difference lattice Boltzmann method(FDLBM)are hyperbolic,and can be solved using Cartesian grids locally,explicitly and efficiently on parallel computers,a program of study to develop a viable FDLBM numerical scheme that can mimic these characteristics individually in any model blood flow problem was initiated.The present objective is to first develop a steady FDLBM with an immersed boundary(IB)method to model blood flow in stenoic artery over a range of Reynolds numbers.The resulting equations in the FDLBM/IB numerical scheme can still be solved using Cartesian grids;thus,changing complex artery geometry can be treated without resorting to grid generation.The FDLBM/IB numerical scheme is validated against known data and is then used to study Newtonian and non-Newtonian fluid flow through constricted tubes.The investigation aims to gain insight into the constricted flow behavior and the non-Newtonian fluid effect on this behavior. 展开更多
关键词 Finite difference method lattice Boltzmann method immersed boundary method blood flow constricted pipe
原文传递
Construction of EMS-Induced Peanut Mutant Libraries and Identification of Pod-Related Traits Mutant Lines
11
作者 Hao Chen Faqian Xiong +9 位作者 Rilong Xu Xiangyu Chen Haifeng Zhong Yumei Zhang Xinlong Lan Hong Zhang Yuhua Chen Runfang Hu Guoqiang Lin Zhaoxiu Tang 《Phyton-International Journal of Experimental Botany》 SCIE 2023年第2期537-557,共21页
Peanut(Arachis hypogaea L.)is an oil and economic crop of vital importance,and peanut pod is the key organ influencing the yield and processing quality.Hence,the Pod-related traits(PRTs)are considered as important agr... Peanut(Arachis hypogaea L.)is an oil and economic crop of vital importance,and peanut pod is the key organ influencing the yield and processing quality.Hence,the Pod-related traits(PRTs)are considered as important agronomic traits in peanut breeding.To broaden the variability of PRTs in current peanut germplasms,three elite peanut cultivars were used to construct Ethyl methane sulfonate(EMS)-induced mutant libraries in this study.The optimal EMS treatment conditions for the three peanut varieties were determined.It was found that the median lethal dose(LD50)of EMS treatment varied greatly among different genotypes.Finally,the EMS-induced peanut mutant libraries were constructed and a total of 124 mutant lines for PRTs were identified and evaluated.Furthermore,“M-8070”,one of the mutant lines for pod constriction,was re-sequenced via high-throughput sequencing technology.The genome-wide variations between“M-8070”and its wild parent“Fuhua 8”(FH 8)were detected.2994 EMS-induced single nucleotide polymorphisms(SNPs)and 1188 insertion-deletions(InDels)between“M-8070”and its wild parent were identified.The predominant SNP mutation type was C/G to T/A transitions,while the predominant InDel mutation type was“1-bp”.We analyzed the distribution of identified mutations and annotated their functions.Most of the mutations(91.68%of the SNPs and 77.69%of the InDels)were located in the intergenic region.72 SNPs were identified in the exonic region,leading to 27 synonymous,43 nonsynonymous and 2 stop-gain variation for gene structure.13 Indels were identified in the exonic region,leading to 4 frame-shift,8 non-frame-shift and 1 stop-gain variations of genes.These mutations may lead to the phenotypic variation of“M-8070”.Our study provided valuable resources for peanut improvement and functional genomic research. 展开更多
关键词 PEANUT EMS-induced mutant line pod-related traits RE-SEQUENCING pod constriction
下载PDF
Safety and efficacy of balloon angioplasty compared to stent-basedstrategies with pulmonary vein stenosis:A systematic review and meta-analysis
12
作者 Pradyumna Agasthi Srilekha Sridhara +14 位作者 Pattara Rattanawong Nithin Venepally Chieh-Ju Chao Hasan Ashraf Sai Harika Pujari Mohamed Allam Diana Almader-Douglas Yamini Alla Amit Kumar Farouk Mookadam Douglas L Packer David R Holmes Jr Donald J Hagler Floyd David Fortuin Reza Arsanjani 《World Journal of Cardiology》 2023年第2期64-75,共12页
BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angio... BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angioplasty(PBA)or pulmonary vein stent implantation(PSI).AIM To study the safety and efficacy outcomes of PBA vs PSI in all patient categories with PVS.METHODS We performed a literature search of all studies comparing outcomes of patients evaluated by PBA vs PSI for PVS.We selected all published studies comparing PBA vs PSI for PVS with reported outcomes of restenosis and procedure-related complications in all patient categories.In adults,PVS following atrial fibrillation ablation and in children PVS related to congenital etiology or post-procedural PVS following total or partial anomalous pulmonary venous return repair were included.The patient-centered outcomes were risk of restenosis requiring re-intervention and procedural-related complications.The metaanalysis was performed by computing odds ratios(ORs)using the random effects model based on underlying statistical heterogeneity.RESULTS Eight observational studies treating 768 severe PVS in 487 patients met our inclusion criteria.The age range of patients was 6 months to 70 years and 67%were males.The primary outcome of the re-stenosis requiring re-intervention occurred in 196 of 325 veins in the PBA group and 111 of 443 veins in the PSI group.Compared to PSI,PBA was associated with a significantly increased risk of re-stenosis(OR 2.91,95%CI:1.15-7.37,P=0.025,I2=79.2%).Secondary outcomes of the procedurerelated complications occurred in 7 of 122 patients in the PBA group and 6 of 69 in the PSI group.There were no statistically significant differences in the safety outcomes between the two groups(OR:0.94,95%CI:0.23-3.76,P=0.929,I^(2)=0.0%).CONCLUSION Across all patient categories with PVS,PSI is associated with reduced risk of re-intervention and is as safe as PBA and should be considered first-line therapy for PVS. 展开更多
关键词 Pulmonary veins Pulmonary vein stenosis CONSTRICTION Balloon angioplasty STENTS Drugeluting stents
下载PDF
Hourglass-like constriction of the anterior interosseous nerve in the left forearm:A case report
13
作者 Rong He Jian-Long Yu +6 位作者 Hai-Long Jin Liqi Ng Jin-Chao Wang Xin Li Ting-Ting Gai Yu Zhou Da-Peng Li 《World Journal of Clinical Cases》 SCIE 2023年第17期4194-4201,共8页
BACKGROUND Hourglass-like constriction neuropathy is a rare neurological disorder.The main clinical manifestation is peripheral nerve injury with no apparent cause,and the pathomorphological change is an unexplained n... BACKGROUND Hourglass-like constriction neuropathy is a rare neurological disorder.The main clinical manifestation is peripheral nerve injury with no apparent cause,and the pathomorphological change is an unexplained narrowing of the diseased nerve.The diagnosis and treatment of the disease are challenging and there is no accepted diagnostic or therapeutic approach.CASE SUMMARY This report describes a rare hourglass constriction of the anterior interosseous nerve in the left forearm in a 47-year-old healthy male who was treated surgically and gradually recovered function over a 6-mo follow-up period.CONCLUSION Hourglass-like constriction neuropathy is a rare disorder.With the development of medical technology,more examinations are now available for diagnosis.This case aims to highlight the rare manifestations of Hourglass-like constriction neuropathy and provides a reference for enriching the clinical diagnosis and treatment experience. 展开更多
关键词 Hourglass-like constriction neuropathy Anterior interosseous nerve of the forearm Nerve Surgery Literature review Case report
下载PDF
膨胀海绵地塞米松填塞治疗外耳道狭窄 被引量:4
14
作者 康琦 赵宇 《中国耳鼻咽喉头颈外科》 北大核心 2011年第8期410-410,共1页
目前外耳道狭窄以手术治疗为主。对于外耳道成形术后及慢性中耳炎术后瘢痕形成初期(术后2~4周)和继发于外耳道炎症、肉芽组织增生所致的狭窄,我们用膨胀海绵配合地塞米松治疗,取得满意疗效,现报道如下。
关键词 耳道(Ear Canal) 耳疾病(Ear Diseases) 缩窄 病理性(Constriction Pathologic) 地塞米松 (Dexamethasone) 膨胀海绵(expansive sponge)
下载PDF
Influence of arc constriction current frequency on tensile properties and microstructural evolution of tungsten inert gas welded thin sheets of aerospace alloy 被引量:2
15
作者 Tushar SONAR Sudersanan MALARVIZHI Visvalingam BALASUBRAMANIAN 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2021年第2期456-474,共19页
The main objective of this investigation is to study the influence of arc constriction current frequency(ACCF)on tensile properties and microstructural evolution of aerospace Alloy 718 sheets(2 mm in thickness)joined ... The main objective of this investigation is to study the influence of arc constriction current frequency(ACCF)on tensile properties and microstructural evolution of aerospace Alloy 718 sheets(2 mm in thickness)joined by constricted arc TIG(CA-TIG)welding process.One variable at a time approach of design of experiments(DOE)was used,in which ACCF was varied from 4 to 20 kHz at an interval of 5 levels while other parameters were kept constant.The joints welded using ACCF of 4 kHz exhibited superior tensile properties extending joint efficiency up to 99.20%.It is attributed to the grain refinement in fusion zone leading to the evolution of finer,discrete Laves phase in interdendritic areas.An increase of ACCF above 12 kHz caused severe grain growth and evolution of coarser Laves phase in fusion zone.Alloy 718 welds showed more obvious tendency for Nb segregation and Laves phase formation at higher levels of ACCF due to the slower cooling rate.The volume fraction of Laves phase was increased by 62.31%at ACCF of 20 kHz compared to that at 4 kHz,thereby reducing the tensile properties of joints.This is mainly due to the stacking of heat input in weld thermal cycles at increased levels of ACCF. 展开更多
关键词 constricted arc TIG welding arc constriction current frequency Alloy 718 sheet tensile properties microstructural evolution Laves phase
下载PDF
Effect of porosity on active damping of geometrically nonlinear vibrations of a functionally graded magneto-electro-elastic plate
16
作者 L.Sh Esayas Subhaschandra Kattimani 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第6期891-906,共16页
This paper investigates the effect of porosity on active damping of geometrically nonlinear vibrations(GNLV)of the magneto-electro-elastic(MEE)functionally graded(FG)plates incorporated with active treatment constrict... This paper investigates the effect of porosity on active damping of geometrically nonlinear vibrations(GNLV)of the magneto-electro-elastic(MEE)functionally graded(FG)plates incorporated with active treatment constricted layer damping(ATCLD)patches.The perpendicularly/slanted reinforced 1-3 piezoelectric composite(1-3 PZC)constricting layer.The constricted viscoelastic layer of the ATCLD is modeled in the time-domain using Golla-Hughes-Mc Tavish(GHM)technique.Different types of porosity distribution in the porous magneto-electro-elastic functionally graded PMEE-FG plate graded in the thickness direction.Considering the coupling effects among elasticity,electrical,and magnetic fields,a three-dimensional finite element(FE)model for the smart PMEE-FG plate is obtained by incorporating the theory of layer-wise shear deformation.The geometric nonlinearity adopts the von K arm an principle.The study presents the effects of a variant of a power-law index,porosity index,the material gradation,three types of porosity distribution,boundary conditions,and the piezoelectric fiber’s orientation angle on the control of GNLV of the PMEE-FG plates.The results reveal that the FG substrate layers’porosity significantly impacts the nonlinear behavior and damping performance of the PMEE-FG plates. 展开更多
关键词 Nonlinear vibration Magneto-electro-elastic(MEE)plates Active treatment constricted layer damping(ATCLD) Porosity distribution Porous functionally graded
下载PDF
Optimal choice of parameters for particle swarm optimization 被引量:14
17
作者 张丽平 俞欢军 胡上序 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第6期528-534,共7页
The constriction factor method (CFM) is a new variation of the basic particle swarm optimization (PSO), which has relatively better convergent nature. The effects of the major parameters on CFM were systematically inv... The constriction factor method (CFM) is a new variation of the basic particle swarm optimization (PSO), which has relatively better convergent nature. The effects of the major parameters on CFM were systematically investigated based on some benchmark functions. The constriction factor, velocity constraint, and population size all have significant impact on the per- formance of CFM for PSO. The constriction factor and velocity constraint have optimal values in practical application, and im- proper choice of these factors will lead to bad results. Increasing population size can improve the solution quality, although the computing time will be longer. The characteristics of CFM parameters are described and guidelines for determining parameter values are given in this paper. 展开更多
关键词 Particle swarm optimization (PSO) Constriction factor method (CFM) Parameter selection
下载PDF
Molecular mechanisms underlying the effects of acupuncture on neuropathic pain 被引量:9
18
作者 Ziyong Ju Huashun Cui +3 位作者 Xiaohui Guo Huayuan Yang Jinsen He Ke Wang 《Neural Regeneration Research》 SCIE CAS CSCD 2013年第25期2350-2359,共10页
Acupuncture has been used to treat neuropathic pain for a long time, but its mechanisms of action remain unknown. In this study, we observed the effects of electroacupuncture and manual acu- puncture on neuropathic pa... Acupuncture has been used to treat neuropathic pain for a long time, but its mechanisms of action remain unknown. In this study, we observed the effects of electroacupuncture and manual acu- puncture on neuropathic pain and on ephrin-B/EphB signaling in rats models of chronic constriction injury-induced neuropathic pain. The results showed that manual acupuncture and electroacu- puncture significantly reduced mechanical hypersensitivity following chronic constriction injury, es- pecially electroacupuncture treatment. Real-time PCR results revealed that ephrin-B1/B3 and EphB1/B2 mRNA expression levels were significantly increased in the spinal dorsal horns of chronic constriction injury rats. Electroacupuncture and manual acupuncture suppressed the high expres- sion of ephrin-B1 mRNA, and elevated EphB3/B4 mRNA expression. Electroacupuncture signifi- cantly enhanced the mRNA expression of ephrin-B3 and EphB3/B6 in the dorsal horns of neuro- pathic pain rats. Western blot results revealed that electroacupuncture in particular, and manual acupuncture, significantly up-regulated ephrin-B3 protein levels in rat spinal dorsal horns. The re- sults of this study suggest that acupuncture could activate ephrin-B/EphB signaling in neuropathic pain rats and improve neurological function. 展开更多
关键词 neural regeneration ACUPUNCTURE neuropathic pain chronic constriction injury ELECTROACUPUNCTURE spinal dorsal horn ephrin-B/EphB signaling nerve repair grants-supported paper NEUROREGENERATION
下载PDF
Three-dimensional virtual operations can facilitate complicated surgical planning for the treatment of patients with jaw deformities associated with facial asymmetry: a case report 被引量:6
19
作者 Shingo Hara Masaharu Mitsugi +3 位作者 Takahiro Kanno Akihiko Nomachi Takehiko Wajima Yukihiro Tatemoto 《International Journal of Oral Science》 SCIE CAS CSCD 2013年第3期176-182,共7页
This article describes a case we experienced in which good postsurgical facial profiles were obtained for a patient with jaw deformities associated with facial asymmetry,by implementing surgical planning with SimPlant... This article describes a case we experienced in which good postsurgical facial profiles were obtained for a patient with jaw deformities associated with facial asymmetry,by implementing surgical planning with SimPlant OMS.Using this method,we conducted LF1 osteotomy,intraoral vertical ramus osteotomy(IVRO),sagittal split ramus osteotomy(SSRO),mandibular constriction and mandibular border genioplasty.Not only did we obtain a class I occlusal relationship,but the complicated surgery also improved the asymmetry of the frontal view,as well as of the profile view,of the patient.The virtual operation using three-dimensional computed tomography(3D-CT)could be especially useful for the treatment of patients with jaw deformities associated with facial asymmetry. 展开更多
关键词 facial asymmetry mnandibular constriction transverse discrepancy of the dental arch width virtual operation
下载PDF
Experimental study on sliding shaft lining mechanical mechanisms under ground subsidence conditions 被引量:11
20
作者 姚直书 杨俊杰 孙文若 《Journal of Coal Science & Engineering(China)》 2003年第1期95-99,共5页
Aimed at more than 60 shaft linings damaged in Huaibei, Datun, Xuzhou and Yanzhou mine areas, this paper presents a new type of sliding shaft lining with asphalt blocks sliding layer. By model test, it is obtained tha... Aimed at more than 60 shaft linings damaged in Huaibei, Datun, Xuzhou and Yanzhou mine areas, this paper presents a new type of sliding shaft lining with asphalt blocks sliding layer. By model test, it is obtained that the deformation characteristics and the mechanical mechanisms of the sliding shaft lining under the condition of ground subsidence. The research results provide a testing basis for the sliding shaft lining design. By now, this kind of sliding shaft lining had been applied in 9 shafts in China and Bangladesh. 展开更多
关键词 shaft lining asphalt blocks sliding layer constrictive layer model test
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部