Constructed wetlands(CWs) have been successfully used for treating various wastewaters for decades and have been identified as a sustainable wastewater management option worldwide.However,the application of CW for w...Constructed wetlands(CWs) have been successfully used for treating various wastewaters for decades and have been identified as a sustainable wastewater management option worldwide.However,the application of CW for wastewater treatment in frigid climate presents special challenges.Wetland treatment of wastewater relies largely on biological processes,and reliable treatment is often a function of climate conditions.To date,the rate of adoption of wetland technology for wastewater treatment in cold regions has been slow and there are relatively few published reports on CW applications in cold climate.This paper therefore highlights the practice and applications of treatment wetlands in cold climate.A comprehensive review of the effectiveness of contaminant removal in different wetland systems including:(1) free water surface(FWS) CWs;(2) subsurface flow(SSF) CWs;and(3) hybrid wetland systems,is presented.The emphasis of this review is also placed on the influence of cold weather conditions on the removal efficacies of different contaminants.The strategies of wetland design and operation for performance intensification,such as the presence of plant,operational mode,effluent recirculation,artificial aeration and in-series design,which are crucial to achieve the sustainable treatment performance in cold climate,are also discussed.This study is conducive to further research for the understanding of CW design and treatment performance in cold climate.展开更多
This study assessed the performance and diversity of microbial communities in multi-stage sub-surface flow constructed wetland systems(CWs). Our aim was to assess the impact of configuration on treatment performance...This study assessed the performance and diversity of microbial communities in multi-stage sub-surface flow constructed wetland systems(CWs). Our aim was to assess the impact of configuration on treatment performance and microbial diversity in the systems. Results indicate that at loading rates up to 100 g BOD5/(m2·day), similar treatment performances can be achieved using either a 3 or 4 stage configuration. In the case of phosphorus(P), the impact of configuration was less obvious and a minimum of 80% P removal can be expected for loadings up to 10 g P/(m2·day) based on the performance results obtained within the first16 months of operation. Microbial analysis showed an increased bacterial diversity in stage four compared to the first stage. These results indicate that the design and configuration of multi-stage constructed wetland systems may have an impact on the treatment performance and the composition of the microbial community in the systems, and such knowledge can be used to improve their design and performance.展开更多
文摘Constructed wetlands(CWs) have been successfully used for treating various wastewaters for decades and have been identified as a sustainable wastewater management option worldwide.However,the application of CW for wastewater treatment in frigid climate presents special challenges.Wetland treatment of wastewater relies largely on biological processes,and reliable treatment is often a function of climate conditions.To date,the rate of adoption of wetland technology for wastewater treatment in cold regions has been slow and there are relatively few published reports on CW applications in cold climate.This paper therefore highlights the practice and applications of treatment wetlands in cold climate.A comprehensive review of the effectiveness of contaminant removal in different wetland systems including:(1) free water surface(FWS) CWs;(2) subsurface flow(SSF) CWs;and(3) hybrid wetland systems,is presented.The emphasis of this review is also placed on the influence of cold weather conditions on the removal efficacies of different contaminants.The strategies of wetland design and operation for performance intensification,such as the presence of plant,operational mode,effluent recirculation,artificial aeration and in-series design,which are crucial to achieve the sustainable treatment performance in cold climate,are also discussed.This study is conducive to further research for the understanding of CW design and treatment performance in cold climate.
文摘This study assessed the performance and diversity of microbial communities in multi-stage sub-surface flow constructed wetland systems(CWs). Our aim was to assess the impact of configuration on treatment performance and microbial diversity in the systems. Results indicate that at loading rates up to 100 g BOD5/(m2·day), similar treatment performances can be achieved using either a 3 or 4 stage configuration. In the case of phosphorus(P), the impact of configuration was less obvious and a minimum of 80% P removal can be expected for loadings up to 10 g P/(m2·day) based on the performance results obtained within the first16 months of operation. Microbial analysis showed an increased bacterial diversity in stage four compared to the first stage. These results indicate that the design and configuration of multi-stage constructed wetland systems may have an impact on the treatment performance and the composition of the microbial community in the systems, and such knowledge can be used to improve their design and performance.