The aluminum alloy parts used in airbag of car were studied with flow control forming(FCF) method, which was a good way to low forming force and better mechanical properties. The key technology of FCF was the design o...The aluminum alloy parts used in airbag of car were studied with flow control forming(FCF) method, which was a good way to low forming force and better mechanical properties. The key technology of FCF was the design of control chamber to divide metal flow. So, the design method of FCF was analyzed and two type of control chamber were put forward. According to divisional principle, calculation model of forming force and approximate formula were given. Then forming process of aluminum alloy multi-layer cylinder parts was simulated. The effect of friction factor, die radius and punch velocity on metal flow and forming force was obtained. Finally, the experiment was preformed under the direction of theory and finite element(FE) simulation results. And the qualified parts were manufactured. The simulation data and experimental results show that the forming sequence of inner wall and outer wall, and then the force step, can be controlled by adjusting the process parameters. And the FCF technology proposed has very important application value in precision forging.展开更多
To develop technically feasible and economically favorable dynamic process control(DPC)strategies for an alternating activated sludge(AAS)system,a bench-scale continuous-flow alternating aerobic and anoxic reactor,per...To develop technically feasible and economically favorable dynamic process control(DPC)strategies for an alternating activated sludge(AAS)system,a bench-scale continuous-flow alternating aerobic and anoxic reactor,performing short-cut nitrogen removal from real domestic wastewater was operated under different control strategies for more than five months.A fixed-time control(FTC) study showed that bending-points on pH and oxidation-reduction potential(ORP)profiles accurately coincided with the major biologic...展开更多
In this paper three controllers for A/O process are developed, including a DO cascade controller, an external carbon flow rate controller and an internal recycling flow rate controller. The objective of the different ...In this paper three controllers for A/O process are developed, including a DO cascade controller, an external carbon flow rate controller and an internal recycling flow rate controller. The objective of the different controllers is to control the nitrate and ammonia concentration. Simulation study demonstrated that these controllers could efficiently control nitrogen removal and meet stricter effluent quality standards at a minimum cost.展开更多
In this paper, a parallel fuzzy proportional plus fuzzy integral plus fuzzy derivative (FP+FI+FD) controller is proposed. It is derived from the conventional parallel proportional-integral-derivative (PID) contr...In this paper, a parallel fuzzy proportional plus fuzzy integral plus fuzzy derivative (FP+FI+FD) controller is proposed. It is derived from the conventional parallel proportional-integral-derivative (PID) controller. It preserves the linear structure of a conventional parallel PID controller, with analytical formulas. The final shape of the controller is a discrete-time fuzzy version of a conventional parallel PID controller. Computer simulations are performed to evaluate the performance of the FP+FI+FD controller for setpoint tracking and load-disturbance rejection for some complex processes, such as first- and second-order processes with delay, inverse response process with and without delay and higher order processes. Also, the performance of the proposed fuzzy controller is evaluated experimentally on highly nonlinear liquid-flow process with a hysteresis characteristic due to a pneumatic control valve. The simulation and real time control is done using National InstrumentTM hardware and software (LabVIEWTM). The response of the FP+FI+FD controller is compared with the conventional parallel PID controller, tuned with the Ziegler-Nichols (Z-H) and /~strSm- H^gglund (A-H) tuning technique. It is observed that the FP+FI+FD controller performed much better than the conventional PI/PID controller. Simulation and experimental results demonstrate the effectiveness of the proposed parallel FP+FI+FD controller.展开更多
Seepage flow through soils,rocks and geotechnical structures has a great influence on their stabilities and performances,and seepage control is a critical technological issue in engineering practices.The physical mech...Seepage flow through soils,rocks and geotechnical structures has a great influence on their stabilities and performances,and seepage control is a critical technological issue in engineering practices.The physical mechanisms associated with various engineering measures for seepage control are investigated from a new perspective within the framework of continuum mechanics;and an equation-based classification of seepage control mechanisms is proposed according to their roles in the mathematical models for seepage flow,including control mechanisms by coupled processes,initial states,boundary conditions and hydraulic properties.The effects of each mechanism on seepage control are illustrated with examples in hydroelectric engineering and radioactive waste disposal,and hence the reasonability of classification is demonstrated.Advice on performance assessment and optimization design of the seepage control systems in geotechnical engineering is provided,and the suggested procedure would serve as a useful guidance for cost-effective control of seepage flow in various engineering practices.展开更多
On the basis of analysis the governing process of downstream water level gates AVIO and AVIS, a mathematical model for simulation of dynamic operation process of hydraulically automated irrigation canals instalIed wit...On the basis of analysis the governing process of downstream water level gates AVIO and AVIS, a mathematical model for simulation of dynamic operation process of hydraulically automated irrigation canals instalIed with AVIO and AVIS gates is presented, the main point of this rnathematical model is firstly applying a set of unsteady flow equations (St. Venant equations here) and treating the condition of gate movement as its dynamic boundary, and then deeoupling this interaction of gate movement with the change of canal flow. In this process, it is necessary to give the gateg open-loop transfer function whose input is water level deviation and output is gate discharge. The result of this simulation for a practical reach has shown it has satisfactory accuracy.展开更多
文摘The aluminum alloy parts used in airbag of car were studied with flow control forming(FCF) method, which was a good way to low forming force and better mechanical properties. The key technology of FCF was the design of control chamber to divide metal flow. So, the design method of FCF was analyzed and two type of control chamber were put forward. According to divisional principle, calculation model of forming force and approximate formula were given. Then forming process of aluminum alloy multi-layer cylinder parts was simulated. The effect of friction factor, die radius and punch velocity on metal flow and forming force was obtained. Finally, the experiment was preformed under the direction of theory and finite element(FE) simulation results. And the qualified parts were manufactured. The simulation data and experimental results show that the forming sequence of inner wall and outer wall, and then the force step, can be controlled by adjusting the process parameters. And the FCF technology proposed has very important application value in precision forging.
文摘To develop technically feasible and economically favorable dynamic process control(DPC)strategies for an alternating activated sludge(AAS)system,a bench-scale continuous-flow alternating aerobic and anoxic reactor,performing short-cut nitrogen removal from real domestic wastewater was operated under different control strategies for more than five months.A fixed-time control(FTC) study showed that bending-points on pH and oxidation-reduction potential(ORP)profiles accurately coincided with the major biologic...
基金This work was supported by"863"Program of China (2004AA601020),The Project of Beijing Science and technology Committee(H020620010120) and the project of Beijing city key laboratory
文摘In this paper three controllers for A/O process are developed, including a DO cascade controller, an external carbon flow rate controller and an internal recycling flow rate controller. The objective of the different controllers is to control the nitrate and ammonia concentration. Simulation study demonstrated that these controllers could efficiently control nitrogen removal and meet stricter effluent quality standards at a minimum cost.
文摘In this paper, a parallel fuzzy proportional plus fuzzy integral plus fuzzy derivative (FP+FI+FD) controller is proposed. It is derived from the conventional parallel proportional-integral-derivative (PID) controller. It preserves the linear structure of a conventional parallel PID controller, with analytical formulas. The final shape of the controller is a discrete-time fuzzy version of a conventional parallel PID controller. Computer simulations are performed to evaluate the performance of the FP+FI+FD controller for setpoint tracking and load-disturbance rejection for some complex processes, such as first- and second-order processes with delay, inverse response process with and without delay and higher order processes. Also, the performance of the proposed fuzzy controller is evaluated experimentally on highly nonlinear liquid-flow process with a hysteresis characteristic due to a pneumatic control valve. The simulation and real time control is done using National InstrumentTM hardware and software (LabVIEWTM). The response of the FP+FI+FD controller is compared with the conventional parallel PID controller, tuned with the Ziegler-Nichols (Z-H) and /~strSm- H^gglund (A-H) tuning technique. It is observed that the FP+FI+FD controller performed much better than the conventional PI/PID controller. Simulation and experimental results demonstrate the effectiveness of the proposed parallel FP+FI+FD controller.
基金Supported by the National Natural Science Foundation of China(51079107,50839004)the Program for New Century Excellent Talents in University(NCET-09-0610)
文摘Seepage flow through soils,rocks and geotechnical structures has a great influence on their stabilities and performances,and seepage control is a critical technological issue in engineering practices.The physical mechanisms associated with various engineering measures for seepage control are investigated from a new perspective within the framework of continuum mechanics;and an equation-based classification of seepage control mechanisms is proposed according to their roles in the mathematical models for seepage flow,including control mechanisms by coupled processes,initial states,boundary conditions and hydraulic properties.The effects of each mechanism on seepage control are illustrated with examples in hydroelectric engineering and radioactive waste disposal,and hence the reasonability of classification is demonstrated.Advice on performance assessment and optimization design of the seepage control systems in geotechnical engineering is provided,and the suggested procedure would serve as a useful guidance for cost-effective control of seepage flow in various engineering practices.
基金Supported by the 863 Programof China (2001AA242111)
文摘On the basis of analysis the governing process of downstream water level gates AVIO and AVIS, a mathematical model for simulation of dynamic operation process of hydraulically automated irrigation canals instalIed with AVIO and AVIS gates is presented, the main point of this rnathematical model is firstly applying a set of unsteady flow equations (St. Venant equations here) and treating the condition of gate movement as its dynamic boundary, and then deeoupling this interaction of gate movement with the change of canal flow. In this process, it is necessary to give the gateg open-loop transfer function whose input is water level deviation and output is gate discharge. The result of this simulation for a practical reach has shown it has satisfactory accuracy.