The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contai...The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.展开更多
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange...The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.展开更多
In order to realize the fault diagnosis of the control circuit of all-electronic computer interlocking system(ACIS)for railway signals,taking a five-wire switch electronic control module as an research object,we propo...In order to realize the fault diagnosis of the control circuit of all-electronic computer interlocking system(ACIS)for railway signals,taking a five-wire switch electronic control module as an research object,we propose a method of selecting the sample set of the basic classifier by roulette method and realizing fault diagnosis by using SVM-AdaBoost.The experimental results show that the proportion of basic classifier samples affects classification accuracy,which reaches the highest when the proportion is 85%.When selecting the sample set of basic classifier by roulette method,the fault diagnosis accuracy is generally higher than that of the maximum weight priority method.When the optimal proportion 85%is taken,the accuracy is highest up to 96.3%.More importantly,this way can better adapt to the critical data and improve the anti-interference ability of the algorithm,and therefore it provides a basis for fault diagnosis of ACIS.展开更多
This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V proces...This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load.展开更多
By means of circuit simulation, hardware of electronic control unit (ECU) of high pressure common-rail electronic control fuel system for diesel engine is designed. According to the system requirements for hardware ...By means of circuit simulation, hardware of electronic control unit (ECU) of high pressure common-rail electronic control fuel system for diesel engine is designed. According to the system requirements for hardware of ECU, signal-processing circuit of variable reluctance (VR) sensor, filter circuit for input signal, high voltage power circuit and driver and protection circuit of solenoid are simulated as emphases. Difficulties of wide scope of VR sensor output signal, efficiency of high voltage power and reliable and swift driver of solenoid are solved. The results of simulation show that the hardware meets the requirement of the fuel system. At the same time, circuit simulation can greatly increase quality of the design, alleviate design labor and shorten design time.展开更多
In this paper, a novel Voltage-Controlled Oscillator (VCO) using the harmonic control circuit based on the quad-band Composite Right/Left-Handed (CRLH) Transmission Line (TL) is presented to reduce the phase noi...In this paper, a novel Voltage-Controlled Oscillator (VCO) using the harmonic control circuit based on the quad-band Composite Right/Left-Handed (CRLH) Transmission Line (TL) is presented to reduce the phase noise without the reduction of the frequeacy tuning range and miniaturizing the circuit size. The phase noise has been reduced by the quad-band harmonic control circuit which has the short impedance for the second- and third- and fourth- and fifth-hannonic components. The CRLH TL with two Left-Handed (LH) (backward) and two Right-Handed (RH) (forward) pass bands are used to design the quad-band harmonic control circuit. The high- Q resonator has been used to reduce the phase noise, but it has the problem of the frequency timing range reduction. However, the frequency tuning range of the proposed VCO has not reduced because the phase noise has reduced without the high-Q resonator. The miniaturization of the circuit size is achieved by using the quad-band CRLH TL instead of the conventional RH TL, The phase noise of VCO is - 124.43~ - 122.67 dBc/Hz at 100 kHz in the tuning range of 5. 729 ~5.934 GHz.展开更多
Conventional moving target detection focuses on algorithms to improve detection efficiency. These algorithms pay less attention to the image acquisition means, and usually solve specific problems. This often results i...Conventional moving target detection focuses on algorithms to improve detection efficiency. These algorithms pay less attention to the image acquisition means, and usually solve specific problems. This often results in poor flexibility and reus- ability. Insect compound eyes offer unique advantages for moving target detection and these advantages have attracted the attention of many researchers in recent years. In this paper we proposed a new system for moving target detection. We used the detection mechanism of insect compound eyes for the simulation of the characteristics of structure, control, and function. We discussed the design scheme of the system, the development of the bionic control circuit, and introduced the proposed mathe- matical model of bionic cqmpound eyes for data acquisition and object detection. After this the integrated system was described and discussed. Our paper presents a novel approach for moving target detection. This approach effectively tackles some of the well-known problems in the field of view, resolution, and real-time processing problems in moving target detection.展开更多
The previous operation of the ZLS-Burris gravity meter using a PDA already provides a significant improvement of the operation of a metal spring gravity meter. But in the practical field work the observer usually wish...The previous operation of the ZLS-Burris gravity meter using a PDA already provides a significant improvement of the operation of a metal spring gravity meter. But in the practical field work the observer usually wishes more information about the measurement and the collected data. This situation sug- gested an improvement of the software and computer hardware. The goal was to develop a small useful PC tool that eliminates these deficits. However, it resulted in a very extensive application software, which was developed during 2011-2015. Along the way, some unwanted effects of the original control circuit were detected. Therefore as a last step a complete new control circuit for the feedback system was developed. This new circuit is fast and smooth and without resonance effects to the system. The algorithm parameters can be specifically adapted to the specific gravity meter. The software has a security system that ensures the user, depending on his level of knowledge, a limited access to the software options. Furthermore, a customer project management system is integrated. The observer, the gravity meters, the projects and maps can be assigned. Several ZLS Burris gravity meters can be managed. A large station data management is integrated. Every station has up to more than twenty parameters, such as the mandatory coordinates or supplementary pictures of the station. External storage and documentation of the measurements are possible with extra modules. In addition the maintenance of the gravity meter system is significantly improved. The motor control of the early ZLS Burris gravity meter is also improved. The complete rotation is displayed on the screen. Finally, two survey examples show the advantages of the software related to the accuracy and the time needed for a measurement.展开更多
Ferroresonance is a complex nonlinear electrotechnical phenomenon, which can result in thermal and electrical stresses on the electric power system equipments due to the over voltages and over currents it generates. T...Ferroresonance is a complex nonlinear electrotechnical phenomenon, which can result in thermal and electrical stresses on the electric power system equipments due to the over voltages and over currents it generates. The prediction or determination of ferroresonance depends mainly on the accuracy of the model used. Fractional-order models are more accurate than the integer-order models. In this paper, a fractional-order ferroresonance model is proposed. The influence of the order on the dynamic behaviors of this fractional-order system under different parameters n and F is investigated. Compared with the integral-order ferroresonance system, small change of the order not only affects the dynamic behavior of the system, but also significantly affects the harmonic components of the system. Then the fractional-order ferroresonance system is implemented by nonlinear circuit emulator. Finally, a fractional-order adaptive sliding mode control (FASMC) method is used to eliminate the abnormal operation state of power system. Since the introduction of the fractional-order sliding mode surface and the adaptive factor, the robustness and disturbance rejection of the controlled system are en- hanced. Numerical simulation results demonstrate that the proposed FASMC controller works well for suppression of ferroresonance over voltage.展开更多
The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation...The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time展开更多
Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy.A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor functio...Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy.A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method.Through a series of novel design concepts,including the integration of a detecting circuit and an analog-to-digital converter,a miniaturized functional electrical stimulation circuit technique,a low-power super-regeneration chip for wireless receiving,and two wearable armbands,a prototype system has been established with reduced size,power,and overall cost.Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects,the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy.Test results showed that wrist flexion/extension,hand grasp,and finger extension could be reproduced with high accuracy and low latency.This system can build a bridge of information transmission between healthy limbs and paralyzed limbs,effectively improve voluntary participation of hemiplegic patients,and elevate efficiency of rehabilitation training.展开更多
Cell therapy approaches that employ engineered mam-malian cells for on-demand production of therapeutic agents in the patient's body are moving beyond proof-of-concept in translational medicine.The therapeutic cel...Cell therapy approaches that employ engineered mam-malian cells for on-demand production of therapeutic agents in the patient's body are moving beyond proof-of-concept in translational medicine.The therapeutic cells can be customized to sense user-defined signals,pro-cess them,and respond in a programmable and pre-dictable way.In this paper,we introduce the available tools and strategies employed to design therapeutic cells.Then,various approaches to control cell behav-iors,including open-loop and closed-loop systems,are discussed.We also highlight therapeutic applications of engineered cells for early diagnosis and treatment of various diseases in the clinic and in experimental dis-ease models.Finally,we consider emerging technolo-gies such as digital devices and their potential for incorporation into future cell-based therapies.展开更多
A design of a replica bit line control circuit to optimize power for SRAM is proposed. The proposed design overcomes the limitations of the traditional replica bit line control circuit, which cannot shut off the word ...A design of a replica bit line control circuit to optimize power for SRAM is proposed. The proposed design overcomes the limitations of the traditional replica bit line control circuit, which cannot shut off the word line in time. In the novel design, the delay of word line enable and disable paths are balanced. Thus, the word line can be opened and shut off in time. Moreover, the chip select signal is decomposed, which prevents feedback oscillations caused by the replica bit line and the replica word line. As a result, the switch power caused by unnec- essary discharging of the bit line is reduced. A 2-kb SRAM is fully custom designed in an SMIC 65-nm CMOS process. The traditional replica bit line control circuit and the new replica bit line control circuit are used in the designed SRAM, and their performances are compared with each other. The experimental results show that at a supply voltage of 1.2 V, the switch power consumption of the memory array can be reduced by 53.7%.展开更多
This paper describes using a high-speed continuous-time analog adaptive equalizer as the front-end of a receiver for a high-speed serial interface,which is compliant with many serial communication specifications such ...This paper describes using a high-speed continuous-time analog adaptive equalizer as the front-end of a receiver for a high-speed serial interface,which is compliant with many serial communication specifications such as USB2.0,PCI-E2.0 and Rapid 10.The low and high frequency loops are merged to decrease the effect of delay between the two paths,in addition,the infinite input impedance facilitates the cascade stages in order to improve the high frequency boosting gain.The implemented circuit architecture could facilitate the wide frequency range from 1 to 3.3 Gbps with different length FR4-PCB traces,which brings as much as 25 dB loss.The replica control circuits are injected to provide a convenient way to regulate common-mode voltage for full differential operation.In addition,AC coupling is adopted to suppress the common input from the forward stage.A prototype chip was fabricated in 0.18-μm 1P6M mixed-signal CMOS technology.The actual area is 0.6×0.57 mm;and the analog equalizer operates up to 3.3 Gbps over FR4-PCB trace with 25 dB loss.The overall power dissipation is approximately 23.4 mW.展开更多
文摘The article designs a new type of bridge circuit with a controlled source—when the resistance on the bridge arm of the controlled source bridge circuit meets the bridge balance condition, and the bridge branch contains only one Current-Controlled Current Source (CCCS), a Voltage-Controlled Current Source (VCCS), a Current-Controlled Voltage Source (CCVS), or a Voltage-Controlled Voltage Source (VCVS), the circuit is called a controlled bridge circuit, which has the characteristics of bridge balance. Due to the relationship between the controlled source and the bridge arm, the sensitivity of the components on the bridge is higher mathematically and logically. When applied to measurement, engineering, automatic control, and other fields, the controlled bridge circuit has higher control ac-curacy. Mathematical derivation and simulation results prove the correctness of the bridge balance conclusion and the special properties of this bridge when applied to the measurement field.
文摘The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.
基金Natural Science Foundation of Gansu Province(Nos.18JR3RA130,2018C-11,2018A-022)Science Fund of Lanzhou Jiaotong University(No.2017022)。
文摘In order to realize the fault diagnosis of the control circuit of all-electronic computer interlocking system(ACIS)for railway signals,taking a five-wire switch electronic control module as an research object,we propose a method of selecting the sample set of the basic classifier by roulette method and realizing fault diagnosis by using SVM-AdaBoost.The experimental results show that the proportion of basic classifier samples affects classification accuracy,which reaches the highest when the proportion is 85%.When selecting the sample set of basic classifier by roulette method,the fault diagnosis accuracy is generally higher than that of the maximum weight priority method.When the optimal proportion 85%is taken,the accuracy is highest up to 96.3%.More importantly,this way can better adapt to the critical data and improve the anti-interference ability of the algorithm,and therefore it provides a basis for fault diagnosis of ACIS.
文摘This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load.
文摘By means of circuit simulation, hardware of electronic control unit (ECU) of high pressure common-rail electronic control fuel system for diesel engine is designed. According to the system requirements for hardware of ECU, signal-processing circuit of variable reluctance (VR) sensor, filter circuit for input signal, high voltage power circuit and driver and protection circuit of solenoid are simulated as emphases. Difficulties of wide scope of VR sensor output signal, efficiency of high voltage power and reliable and swift driver of solenoid are solved. The results of simulation show that the hardware meets the requirement of the fuel system. At the same time, circuit simulation can greatly increase quality of the design, alleviate design labor and shorten design time.
文摘In this paper, a novel Voltage-Controlled Oscillator (VCO) using the harmonic control circuit based on the quad-band Composite Right/Left-Handed (CRLH) Transmission Line (TL) is presented to reduce the phase noise without the reduction of the frequeacy tuning range and miniaturizing the circuit size. The phase noise has been reduced by the quad-band harmonic control circuit which has the short impedance for the second- and third- and fourth- and fifth-hannonic components. The CRLH TL with two Left-Handed (LH) (backward) and two Right-Handed (RH) (forward) pass bands are used to design the quad-band harmonic control circuit. The high- Q resonator has been used to reduce the phase noise, but it has the problem of the frequency timing range reduction. However, the frequency tuning range of the proposed VCO has not reduced because the phase noise has reduced without the high-Q resonator. The miniaturization of the circuit size is achieved by using the quad-band CRLH TL instead of the conventional RH TL, The phase noise of VCO is - 124.43~ - 122.67 dBc/Hz at 100 kHz in the tuning range of 5. 729 ~5.934 GHz.
基金The work presented in this paper is supported by the Scholarship for International Young Scientists of NSFC (National Natural Science Foundation of China) (1D: 41050110441).
文摘Conventional moving target detection focuses on algorithms to improve detection efficiency. These algorithms pay less attention to the image acquisition means, and usually solve specific problems. This often results in poor flexibility and reus- ability. Insect compound eyes offer unique advantages for moving target detection and these advantages have attracted the attention of many researchers in recent years. In this paper we proposed a new system for moving target detection. We used the detection mechanism of insect compound eyes for the simulation of the characteristics of structure, control, and function. We discussed the design scheme of the system, the development of the bionic control circuit, and introduced the proposed mathe- matical model of bionic cqmpound eyes for data acquisition and object detection. After this the integrated system was described and discussed. Our paper presents a novel approach for moving target detection. This approach effectively tackles some of the well-known problems in the field of view, resolution, and real-time processing problems in moving target detection.
文摘The previous operation of the ZLS-Burris gravity meter using a PDA already provides a significant improvement of the operation of a metal spring gravity meter. But in the practical field work the observer usually wishes more information about the measurement and the collected data. This situation sug- gested an improvement of the software and computer hardware. The goal was to develop a small useful PC tool that eliminates these deficits. However, it resulted in a very extensive application software, which was developed during 2011-2015. Along the way, some unwanted effects of the original control circuit were detected. Therefore as a last step a complete new control circuit for the feedback system was developed. This new circuit is fast and smooth and without resonance effects to the system. The algorithm parameters can be specifically adapted to the specific gravity meter. The software has a security system that ensures the user, depending on his level of knowledge, a limited access to the software options. Furthermore, a customer project management system is integrated. The observer, the gravity meters, the projects and maps can be assigned. Several ZLS Burris gravity meters can be managed. A large station data management is integrated. Every station has up to more than twenty parameters, such as the mandatory coordinates or supplementary pictures of the station. External storage and documentation of the measurements are possible with extra modules. In addition the maintenance of the gravity meter system is significantly improved. The motor control of the early ZLS Burris gravity meter is also improved. The complete rotation is displayed on the screen. Finally, two survey examples show the advantages of the software related to the accuracy and the time needed for a measurement.
基金supported by the National Natural Science Foundation of China(Grant No.51507134)the Science Fund from the Education Department of Shaanxi Province,China(Grant No.15JK1537)
文摘Ferroresonance is a complex nonlinear electrotechnical phenomenon, which can result in thermal and electrical stresses on the electric power system equipments due to the over voltages and over currents it generates. The prediction or determination of ferroresonance depends mainly on the accuracy of the model used. Fractional-order models are more accurate than the integer-order models. In this paper, a fractional-order ferroresonance model is proposed. The influence of the order on the dynamic behaviors of this fractional-order system under different parameters n and F is investigated. Compared with the integral-order ferroresonance system, small change of the order not only affects the dynamic behavior of the system, but also significantly affects the harmonic components of the system. Then the fractional-order ferroresonance system is implemented by nonlinear circuit emulator. Finally, a fractional-order adaptive sliding mode control (FASMC) method is used to eliminate the abnormal operation state of power system. Since the introduction of the fractional-order sliding mode surface and the adaptive factor, the robustness and disturbance rejection of the controlled system are en- hanced. Numerical simulation results demonstrate that the proposed FASMC controller works well for suppression of ferroresonance over voltage.
文摘The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time
基金supported by the National Natural Science Foundation of China,No.90307013,90707005,61534003the Science&Technology Pillar Program of Jiangsu Province in China,No.BE2013706
文摘Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy.A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method.Through a series of novel design concepts,including the integration of a detecting circuit and an analog-to-digital converter,a miniaturized functional electrical stimulation circuit technique,a low-power super-regeneration chip for wireless receiving,and two wearable armbands,a prototype system has been established with reduced size,power,and overall cost.Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects,the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy.Test results showed that wrist flexion/extension,hand grasp,and finger extension could be reproduced with high accuracy and low latency.This system can build a bridge of information transmission between healthy limbs and paralyzed limbs,effectively improve voluntary participation of hemiplegic patients,and elevate efficiency of rehabilitation training.
文摘Cell therapy approaches that employ engineered mam-malian cells for on-demand production of therapeutic agents in the patient's body are moving beyond proof-of-concept in translational medicine.The therapeutic cells can be customized to sense user-defined signals,pro-cess them,and respond in a programmable and pre-dictable way.In this paper,we introduce the available tools and strategies employed to design therapeutic cells.Then,various approaches to control cell behav-iors,including open-loop and closed-loop systems,are discussed.We also highlight therapeutic applications of engineered cells for early diagnosis and treatment of various diseases in the clinic and in experimental dis-ease models.Finally,we consider emerging technolo-gies such as digital devices and their potential for incorporation into future cell-based therapies.
基金Project supported by the Zhejiang Provincial Natural Science Foundation of China(No.LQ14F040001)the National Natural Science Foundation of China(Nos.61274132,61234002,61474068)the K.C.Wong Magna Fund in Ningbo University
文摘A design of a replica bit line control circuit to optimize power for SRAM is proposed. The proposed design overcomes the limitations of the traditional replica bit line control circuit, which cannot shut off the word line in time. In the novel design, the delay of word line enable and disable paths are balanced. Thus, the word line can be opened and shut off in time. Moreover, the chip select signal is decomposed, which prevents feedback oscillations caused by the replica bit line and the replica word line. As a result, the switch power caused by unnec- essary discharging of the bit line is reduced. A 2-kb SRAM is fully custom designed in an SMIC 65-nm CMOS process. The traditional replica bit line control circuit and the new replica bit line control circuit are used in the designed SRAM, and their performances are compared with each other. The experimental results show that at a supply voltage of 1.2 V, the switch power consumption of the memory array can be reduced by 53.7%.
基金Project supported by the National Key Program of China(No.2009ZX03007-002-03)
文摘This paper describes using a high-speed continuous-time analog adaptive equalizer as the front-end of a receiver for a high-speed serial interface,which is compliant with many serial communication specifications such as USB2.0,PCI-E2.0 and Rapid 10.The low and high frequency loops are merged to decrease the effect of delay between the two paths,in addition,the infinite input impedance facilitates the cascade stages in order to improve the high frequency boosting gain.The implemented circuit architecture could facilitate the wide frequency range from 1 to 3.3 Gbps with different length FR4-PCB traces,which brings as much as 25 dB loss.The replica control circuits are injected to provide a convenient way to regulate common-mode voltage for full differential operation.In addition,AC coupling is adopted to suppress the common input from the forward stage.A prototype chip was fabricated in 0.18-μm 1P6M mixed-signal CMOS technology.The actual area is 0.6×0.57 mm;and the analog equalizer operates up to 3.3 Gbps over FR4-PCB trace with 25 dB loss.The overall power dissipation is approximately 23.4 mW.