Based on CAN calibration protocol, a new calibration and monitoring system was developed for the GD-1 high pressure common rail diesel engine. CAN driver block, monitoring program and calibration program for this syst...Based on CAN calibration protocol, a new calibration and monitoring system was developed for the GD-1 high pressure common rail diesel engine. CAN driver block, monitoring program and calibration program for this system were designed respectively. The inquiry mode was used in the monitoring program and the interrupt mode was used in calibration program. The calibration program was designed in structural programming model. This system provides a reliable, accurate and quick CAN bus between ECU and PC, with baud rate up to 500Kbit/s. The implementation of the compatible and universal CAN calibration protocol makes it easy to displace the system and its function modules. It also provides friendly, compatible and flexible calibration interface, and the functions of online calibration and real-time monitoring. This system was successfully used in a GD-1 high pressure common rail diesel engine and the engine performance and exhaust emissions were significantly improved.展开更多
Intrapartum maternal normoglycemia seems to play an important role in the prevention of adverse perinatal, maternal and neonatal outcomes. Several glucose monitoring protocols have been developed, aiming to achieve a ...Intrapartum maternal normoglycemia seems to play an important role in the prevention of adverse perinatal, maternal and neonatal outcomes. Several glucose monitoring protocols have been developed, aiming to achieve a tight glucose monitoring and control. Depending on the type of diabetes and the optimal or suboptimal glycemic control, the treatment options include fasting status of the parturient, frequent monitoring of capillary blood glucose, intravenous dextrose infusion and subcutaneous or intravenous use of insulin. Continuous glucose monitoring system(CGMS) is a relatively new technology that measures interstitial glucose at very short time intervals over a specifi c period of time. The resulting profi le provides a more comprehensive measure of glycemic excursions than intermittent home blood glucose monitoring. Results of studies applying the CGMS technology in patients with or without diabetes mellitus(DM) have revealed new insights in glucose metabolism. Moreover, CGMS have a potential role in the improvement of glycemic control during pregnancy and labor, which may lead to a decrease in perinatal morbidity and mortality. In conclusion, the use of CGMS, with its important technical advantages compared to the conventional way of monitoring, may lead into a more etiological intrapartum management of both the mother and her fetus/infant in pregnancies complicated with DM.展开更多
In order to improve the management and control requirements of small electric kilns in ceramic production field.According to the excessive dispersion of electric kilns in porcelain production field,a remote monitoring...In order to improve the management and control requirements of small electric kilns in ceramic production field.According to the excessive dispersion of electric kilns in porcelain production field,a remote monitoring system based on RS485 bus and Modbus protocol is designed.The system consists of data acquisition,field control,cloud monitoring and communication protocol.MCGS is used as the master station to communicate with the temperature controller,collect and transmit the internal data to Siemens PLC.Through the communication between Siemens PLC and IOT gateway,the kiln working data is uploaded to the cloud platform to realize the remote monitoring for ceramic electric kiln.The experimental results showed this system can accurately collect the working temperature and parameters of the kiln in real time,and can remotely cortrol the kiln.展开更多
Background: Studies have shown a strong correlation between the growth of E2 in serum and estrone-3-glucuronide (E1-3G) in urine during ovarian stimulation. Thus, we developed theoretical models for using urinary E1-3...Background: Studies have shown a strong correlation between the growth of E2 in serum and estrone-3-glucuronide (E1-3G) in urine during ovarian stimulation. Thus, we developed theoretical models for using urinary E1-3G in ovarian stimulation and focused on their experimental verification and analysis. Methods: A prospective, observational pilot study was conducted involving 54 patients who underwent 54 cycles of ovarian stimulation. The goal was to establish the growth rate of urinary E1-3G during the course of stimulation and to determine the daily upper and lower limits of growth rates at which stimulation is appropriate and safe. Controlled ovarian stimulation was performed using two different stimulation protocols—an antagonist protocol in 25 cases and a progestin-primed ovarian stimulation protocol (PPOS) in 29 cases, with fixed doses of gonadotropins. From the second day of stimulation, patients self-measured their daily urine E1-3G levels at home using a portable analyzer. In parallel, a standard ultrasound follow-up protocol accompanied by a determination of E2, LH, and P levels was applied to optimally control stimulation. Results: The average daily growth rates in both groups were about 50%. The daily increase in E1-3G for the antagonist protocol ranged from 14% to 79%, while they were 28% to 79% for the PPOS protocol. Conclusion: This is the first study to analyze the dynamics of E1-3G in two different protocols and to estimate the limits of its increase during the entire course of the stimulation. The results confirm our theoretical model for the viability of using urinary E1-3G for monitoring ovarian stimulation.展开更多
This paper describes a hierarchical architecture and a high-performance and interoperability protocol for centralized monitoring and controlling systems (CMCS) . The protocol we proposed can interoperate different mon...This paper describes a hierarchical architecture and a high-performance and interoperability protocol for centralized monitoring and controlling systems (CMCS) . The protocol we proposed can interoperate different monitoring and controlling systems constructed by different companies, each with different functions and communication protocols. The protocol reduces the amount of traffic and has real-time and high-perfor-mance advantages. The protocol was implemented in CMCS for telecommunication power supply and air-condi-tioner used by the Telecommunication Bureau of Zhejiang Province. This paper deals with the hierarchical architecture and function of CMCS and packet format, command ID, and SDL description of its protocol. We also discuss the properties of the interoperability and performance of the protocol in this paper.展开更多
This paper presents a multi-interface embedded server architecture for remote real-time monitoring system and distributed monitoring applications. In the scheme,an embedded microprocessor( LPC3250 from NXP) is chosen ...This paper presents a multi-interface embedded server architecture for remote real-time monitoring system and distributed monitoring applications. In the scheme,an embedded microprocessor( LPC3250 from NXP) is chosen as the CPU of the embedded server with a linux operation system( OS) environment. The embedded server provides multiple interfaces for supporting various application scenarios. The whole network is based on local area network and adopts the Browser / Server( B / S) model. The monitoring and control node is as a browser endpoint and the remote node with an embedded server is as a server endpoint. Users can easily acquire various sensors information through writing Internet protocol address of remote node on the computer browser. Compared with client / server( C / S) mode,B / S model needs less maintain and can be applicable to large user group. In addition,a simple network management protocol( SNMP) is used for management of devices in Internet protocol( IP) networks. The results of the demonstration experiment show that the proposed system gives good support to manage the network from different user terminals and allows the users to better interact with the ambient environment.展开更多
电力监控系统环境中存在过多噪声因素干扰,导致通信效率和质量低。为此,提出一种基于传输控制协议/网际协议(transmission control protocol/internet protocol,TCP/IP)与关联规则的多线程通信算法。将背景噪声看作电力监控信号的突变现...电力监控系统环境中存在过多噪声因素干扰,导致通信效率和质量低。为此,提出一种基于传输控制协议/网际协议(transmission control protocol/internet protocol,TCP/IP)与关联规则的多线程通信算法。将背景噪声看作电力监控信号的突变现象,查找回应突变函数的信号值,利用谐波分离算法,去除背景噪声。根据不同线程的传输特点,采用TCP/IP协议建立通信程序包,分别设置句柄、终止、挂起以及执行函数,为不同线程的通信数据,匹配不同的通信协议。试验结果证明:对电力监控系统源设备的传输信号多线程通信时,通信信号波频变化最为平稳,在0~2000 s的采样区间内,未出现传输为0现象;对背景噪声去噪后,波形相比原始信号变化明显较为稳定,没有出现过高或过低的幅值变化。所提方法通信信号表达平稳、效率较高,对原始信号的保留效果较好,去噪能力很强。展开更多
时间同步技术作为无线微震传感器网络的核心技术之一,是网络协调运行的关键。首先研究了无线传感器网络时间同步原理及影响同步精度的因素;其次研究了经典无线时间同步协的实现方法;然后仿真对比了传感器网络时间同步协议(Timing-sync P...时间同步技术作为无线微震传感器网络的核心技术之一,是网络协调运行的关键。首先研究了无线传感器网络时间同步原理及影响同步精度的因素;其次研究了经典无线时间同步协的实现方法;然后仿真对比了传感器网络时间同步协议(Timing-sync Protocol for Sensor Networks,TPSN)和泛洪式时间同步协议(Flooding Time Synchronization Protocol,FTSP)的同步精度;再针对FTSP协议的不足提出一种改进的G-FTSP协议,能有效提高无线传感器网络时间同步精度;最后估算由时间同步误差造成的微震震源定位误差,验证G-FTSP协议满足实际生产需求。展开更多
文摘Based on CAN calibration protocol, a new calibration and monitoring system was developed for the GD-1 high pressure common rail diesel engine. CAN driver block, monitoring program and calibration program for this system were designed respectively. The inquiry mode was used in the monitoring program and the interrupt mode was used in calibration program. The calibration program was designed in structural programming model. This system provides a reliable, accurate and quick CAN bus between ECU and PC, with baud rate up to 500Kbit/s. The implementation of the compatible and universal CAN calibration protocol makes it easy to displace the system and its function modules. It also provides friendly, compatible and flexible calibration interface, and the functions of online calibration and real-time monitoring. This system was successfully used in a GD-1 high pressure common rail diesel engine and the engine performance and exhaust emissions were significantly improved.
文摘Intrapartum maternal normoglycemia seems to play an important role in the prevention of adverse perinatal, maternal and neonatal outcomes. Several glucose monitoring protocols have been developed, aiming to achieve a tight glucose monitoring and control. Depending on the type of diabetes and the optimal or suboptimal glycemic control, the treatment options include fasting status of the parturient, frequent monitoring of capillary blood glucose, intravenous dextrose infusion and subcutaneous or intravenous use of insulin. Continuous glucose monitoring system(CGMS) is a relatively new technology that measures interstitial glucose at very short time intervals over a specifi c period of time. The resulting profi le provides a more comprehensive measure of glycemic excursions than intermittent home blood glucose monitoring. Results of studies applying the CGMS technology in patients with or without diabetes mellitus(DM) have revealed new insights in glucose metabolism. Moreover, CGMS have a potential role in the improvement of glycemic control during pregnancy and labor, which may lead to a decrease in perinatal morbidity and mortality. In conclusion, the use of CGMS, with its important technical advantages compared to the conventional way of monitoring, may lead into a more etiological intrapartum management of both the mother and her fetus/infant in pregnancies complicated with DM.
基金This paper was supported by Jiangxi Province Key Research and Development Program(202003BBG73071)。
文摘In order to improve the management and control requirements of small electric kilns in ceramic production field.According to the excessive dispersion of electric kilns in porcelain production field,a remote monitoring system based on RS485 bus and Modbus protocol is designed.The system consists of data acquisition,field control,cloud monitoring and communication protocol.MCGS is used as the master station to communicate with the temperature controller,collect and transmit the internal data to Siemens PLC.Through the communication between Siemens PLC and IOT gateway,the kiln working data is uploaded to the cloud platform to realize the remote monitoring for ceramic electric kiln.The experimental results showed this system can accurately collect the working temperature and parameters of the kiln in real time,and can remotely cortrol the kiln.
文摘Background: Studies have shown a strong correlation between the growth of E2 in serum and estrone-3-glucuronide (E1-3G) in urine during ovarian stimulation. Thus, we developed theoretical models for using urinary E1-3G in ovarian stimulation and focused on their experimental verification and analysis. Methods: A prospective, observational pilot study was conducted involving 54 patients who underwent 54 cycles of ovarian stimulation. The goal was to establish the growth rate of urinary E1-3G during the course of stimulation and to determine the daily upper and lower limits of growth rates at which stimulation is appropriate and safe. Controlled ovarian stimulation was performed using two different stimulation protocols—an antagonist protocol in 25 cases and a progestin-primed ovarian stimulation protocol (PPOS) in 29 cases, with fixed doses of gonadotropins. From the second day of stimulation, patients self-measured their daily urine E1-3G levels at home using a portable analyzer. In parallel, a standard ultrasound follow-up protocol accompanied by a determination of E2, LH, and P levels was applied to optimally control stimulation. Results: The average daily growth rates in both groups were about 50%. The daily increase in E1-3G for the antagonist protocol ranged from 14% to 79%, while they were 28% to 79% for the PPOS protocol. Conclusion: This is the first study to analyze the dynamics of E1-3G in two different protocols and to estimate the limits of its increase during the entire course of the stimulation. The results confirm our theoretical model for the viability of using urinary E1-3G for monitoring ovarian stimulation.
文摘This paper describes a hierarchical architecture and a high-performance and interoperability protocol for centralized monitoring and controlling systems (CMCS) . The protocol we proposed can interoperate different monitoring and controlling systems constructed by different companies, each with different functions and communication protocols. The protocol reduces the amount of traffic and has real-time and high-perfor-mance advantages. The protocol was implemented in CMCS for telecommunication power supply and air-condi-tioner used by the Telecommunication Bureau of Zhejiang Province. This paper deals with the hierarchical architecture and function of CMCS and packet format, command ID, and SDL description of its protocol. We also discuss the properties of the interoperability and performance of the protocol in this paper.
基金Sponsored by the National High Technology Research and Development Program(Grant No.2012AA02A604)
文摘This paper presents a multi-interface embedded server architecture for remote real-time monitoring system and distributed monitoring applications. In the scheme,an embedded microprocessor( LPC3250 from NXP) is chosen as the CPU of the embedded server with a linux operation system( OS) environment. The embedded server provides multiple interfaces for supporting various application scenarios. The whole network is based on local area network and adopts the Browser / Server( B / S) model. The monitoring and control node is as a browser endpoint and the remote node with an embedded server is as a server endpoint. Users can easily acquire various sensors information through writing Internet protocol address of remote node on the computer browser. Compared with client / server( C / S) mode,B / S model needs less maintain and can be applicable to large user group. In addition,a simple network management protocol( SNMP) is used for management of devices in Internet protocol( IP) networks. The results of the demonstration experiment show that the proposed system gives good support to manage the network from different user terminals and allows the users to better interact with the ambient environment.
文摘电力监控系统环境中存在过多噪声因素干扰,导致通信效率和质量低。为此,提出一种基于传输控制协议/网际协议(transmission control protocol/internet protocol,TCP/IP)与关联规则的多线程通信算法。将背景噪声看作电力监控信号的突变现象,查找回应突变函数的信号值,利用谐波分离算法,去除背景噪声。根据不同线程的传输特点,采用TCP/IP协议建立通信程序包,分别设置句柄、终止、挂起以及执行函数,为不同线程的通信数据,匹配不同的通信协议。试验结果证明:对电力监控系统源设备的传输信号多线程通信时,通信信号波频变化最为平稳,在0~2000 s的采样区间内,未出现传输为0现象;对背景噪声去噪后,波形相比原始信号变化明显较为稳定,没有出现过高或过低的幅值变化。所提方法通信信号表达平稳、效率较高,对原始信号的保留效果较好,去噪能力很强。
文摘时间同步技术作为无线微震传感器网络的核心技术之一,是网络协调运行的关键。首先研究了无线传感器网络时间同步原理及影响同步精度的因素;其次研究了经典无线时间同步协的实现方法;然后仿真对比了传感器网络时间同步协议(Timing-sync Protocol for Sensor Networks,TPSN)和泛洪式时间同步协议(Flooding Time Synchronization Protocol,FTSP)的同步精度;再针对FTSP协议的不足提出一种改进的G-FTSP协议,能有效提高无线传感器网络时间同步精度;最后估算由时间同步误差造成的微震震源定位误差,验证G-FTSP协议满足实际生产需求。