期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
The first localized back-to-back converter station started expansion
1
《Electricity》 2008年第2期40-,共1页
The first fully localized back-to-back DC intercon-nection project which connects Northwest and CentralChina power grids, 330-kV Lingbao Converter Stationhas now started construction for expansion.Lingbao back-to-back... The first fully localized back-to-back DC intercon-nection project which connects Northwest and CentralChina power grids, 330-kV Lingbao Converter Stationhas now started construction for expansion.Lingbao back-to-back converter station situated inLingbao City of Henan Province is the first DC intercon- 展开更多
关键词 DC KV The first localized back-to-back converter station started expansion
下载PDF
Electromagnetic interference and shielding of valve hall in HVDC converter station
2
作者 Changzheng GAO Lin LI +1 位作者 Zhibin ZHAO Yang LIU 《Frontiers of Electrical and Electronic Engineering in China》 CSCD 2010年第1期100-105,共6页
The electromagnetic interference(EMI)from the valve hall as an important consideration in the design of high voltage direct current(HVDC)converter stations is analyzed by electromagnetic field numerical method and mea... The electromagnetic interference(EMI)from the valve hall as an important consideration in the design of high voltage direct current(HVDC)converter stations is analyzed by electromagnetic field numerical method and measurements.By using moment method,the EMI filed strength level as well as radio interference level(RIL)of the valve hall during the normal operation are computed after an antenna model is built for the valve tower.According to the character of EMI obtained,the practical shielding measures for valve hall are discussed to satisfy the relative standards.The test results for the500 kV converter station show that both the numerical method and shielding technique used in this paper are practical. 展开更多
关键词 electromagnetic interference(EMI) valve hall high voltage direct current(HVDC) converter station SHIELDING
原文传递
高压直流换流站中滤波电容器的振动与可听噪声(英文) 被引量:8
3
作者 祝令瑜 汲胜昌 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2849-2856,共8页
The filter capacitor stack is one of the main acoustic noise sources in high-voltage DC(HVDC) converter stations.As HVDC systems are built more and more recently,it is significant to research the audible noise of filt... The filter capacitor stack is one of the main acoustic noise sources in high-voltage DC(HVDC) converter stations.As HVDC systems are built more and more recently,it is significant to research the audible noise of filter capacitors.In this paper,the current situation of research on vibration and audible noise of filter capacitors in HVDC converter stations,which is departed into three parts—generation mechanism,prediction methods,and reduction measures,is presented and the research achievements are discussed.Scholars have built the model that the alternating electric force caused by the voltage conduces to the vibration,which propagates to the enclosure and radiates audible noise.As a result,the parts contributing most to the generation of audible noise are the top and the bottom of capacitors. In the noise level prediction respect,several methods have been prospected including impact hammer,sweep frequency, impact current,monopole and Kirchhoff formula method,which are suitable for single capacitors or capacitors stacks individually.However,the sweep frequency method is restricted by experiment condition,and the impact current method needs further research and verified.On the other hand,CIGRE WG14.26 provides three sound reduction measures,but all of them are not so practicable,while MPP absorber and compressible space absorber prospected by Dr.Wu Peng are proved to be effective.The sound barriers are also considered by scholars,and the acoustic directivity performance of capacitors is also researched.Besides,the developing direction of each research field is prospected in corresponding part. 展开更多
关键词 audible noise filter capacitor generation mechanism HVDC converter stations prediction method reduction measure VIBRATION
下载PDF
An improved prediction method of subsequent commutation failure of an LCC-HVDC considering sequential control response
4
作者 Jinxin Ouyang Xinyu Pan +3 位作者 Junjun Ye Chao Xiao Yanbo Diao Qingwu Zhang 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第3期173-183,共11页
Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threa... Subsequent commutation failure(SCF)can be easily generated during the first commutation failure(CF)recovery process in a line-commutated converter-based high voltage direct-current system.SCF poses a significant threat to the safe and stable operation of power systems,and accurate prediction of CF is thus important.However,SCF is affected by the operating characteristics of the main circuit and the coupling effects of sequential control response in the inverter station.These are difficult to predict accurately.In this paper,a new SCF prediction method considering the control response is proposed based on the physical principle of SCF.The time sequence and switching conditions of the controllers at different stages of the first CF recovery process are described,and the corresponding equations of commutation voltage affected by different controllers are derived.The calculation method of the SCF threshold voltage is proposed,and the prediction method is established.Simulations show that the proposed method can predict SCF accurately and provide useful tools to suppress SCF. 展开更多
关键词 Line-commutated converter based high-voltage direct-current(LCC-HVDC) Subsequent commutation failure(SCF) converter station PREDICTION
原文传递
Economy Analysis of Flexible LCC-HVDC Systems with Controllable Capacitors 被引量:3
5
作者 Nan Chen Kunpeng Zha +3 位作者 Haitao Qu Fangling Li Ying Xue Xiao-Ping Zhang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2022年第6期1708-1719,共12页
Commutation failure(CF)is a frequent dynamic event at inverter of LCC-HVDC systems caused by AC side faults which can lead to inverter blocking,interruption of active power transfer,and even system blackout.To elimina... Commutation failure(CF)is a frequent dynamic event at inverter of LCC-HVDC systems caused by AC side faults which can lead to inverter blocking,interruption of active power transfer,and even system blackout.To eliminate CFs and improve system performance,new Flexible LCC-HVDC topologies have been proposed in previous research but with limited analysis on its economic performance.Therefore,to further validate the applicability of Flexible LCC-HVDC topologies,this paper utilizes Life-Cycle Cost Analysis model to analyze the life-cycle cost of inverter stations for conventional LCCHVDC,Capacitor Commutated Converter based HVDC(CCCHVDC)topology and Flexible LCC-HVDC topologies including Controllable Capacitor based Flexible LCC-HVDC,AC Filterless Controllable Capacitor based Flexible LCC-HVDC and improved Flexible LCC-HVDC.Through a case study based on a 500 kV,1000 MW LCC-HVDC scheme,comparison results show that the AC Filterless Controllable Capacitor based Flexible LCCHVDC topology and the improved Flexible LCC-HVDC topology have lower cost than the conventional LCC-HVDC and CCCHVDC topologies,which proves that the elimination of CFs can be achieved with reduced cost. 展开更多
关键词 LCC-HVDC Flexible LCC-HVDC controllable capacitor based(CC)LCC-HVDC AC Filterless CC(ACFL-CC)LCC-HVDC improved ACFL-CC LCC-HVDC CCC-HVDC commutation failure converter station economic analysis life-cycle cost LCC controllable capacitor AC filterless
原文传递
Experimental Analysis on Influence of Temperature and Bolted Torque to DC Contact Resistance of Terminal Connector in UHV Valve Hall
6
作者 Jiajun Si Xiaoming Rui +2 位作者 Jingchao Wang Bin Liu Shengchun Liu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第4期858-866,共9页
The overheating problems of terminal connectors severely threaten the operation of ultra-high voltage projects and cause enormous losses of economy,so a higher currentcarrying reliability of the connectors has an impo... The overheating problems of terminal connectors severely threaten the operation of ultra-high voltage projects and cause enormous losses of economy,so a higher currentcarrying reliability of the connectors has an important engineering significance with the development of transmission capacity.In this paper,a bivariate mathematical model of contact resistance as functions of temperature and tightening torque was deduced based on the large current temperature rise tests.To perform such analysis,four typical terminal connectors,namely:overlapping terminal of aluminum plates,overlapping terminal of copper plates,overlapping terminal of plates with clad layer and overlapping terminal of copper rod with aluminum clamp,were chosen for the experiments.The changing rules of DC resistance with different tightening torques and different currents were studied.Then the empirical formula of contact resistance was deduced.Finally,temperature calculations of different terminal connectors were realized to verify the effectiveness of the bivariate mathematical model. 展开更多
关键词 DC contact resistance empirical parameter large current temperature rise test terminal connector UHV converter station
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部