期刊文献+
共找到48篇文章
< 1 2 3 >
每页显示 20 50 100
Cooling rate effects on the structure and transformation behavior of Cu-Zn-Al shape memory alloys
1
作者 Nicoleta-Monica Lohan Marius-Gabriel Suru +1 位作者 Bogdan Pricop Leandru-Gheorghe Bujoreanu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2014年第11期1109-1114,共6页
Different fragments of a hot-rolled and homogenized Cu–Zn–Al shape memory alloy(SMA) were subjected to thermal cycling by means of a differential scanning calorimetric(DSC) device. During thermal cycling, heatin... Different fragments of a hot-rolled and homogenized Cu–Zn–Al shape memory alloy(SMA) were subjected to thermal cycling by means of a differential scanning calorimetric(DSC) device. During thermal cycling, heating was performed at the same constant rate of increasing temperature while cooling was carried out at different rates of decreasing temperature. For each cooling rate, the temperature decreased in the same thermal interval. During each cooling stage, an exothermic peak(maximum) was observed on the DSC thermogram. This peak was associated with forward martensitic transformation. The DSC thermograms were analyzed with PROTEUS software: the critical martensitic transformation start(Ms) and finish(Mf) temperatures were determined by means of integral and tangent methods, and the dissipated heat was evaluated by the area between the corresponding maximum plot and a sigmoid baseline. The effects of the increase in cooling rate, assessed from a calorimetric viewpoint, consisted in the augmentation of the exothermic peak and the delay of direct martensitic transformation. The latter had the tendency to move to lower critical transformation temperatures. The martensite plates changed in morphology by becoming more oriented and by an augmenting in surface relief, which corresponded with the increase in cooling rate as observed by scanning electron microscopy(SEM) and atomic force microscopy(AFM). 展开更多
关键词 copper alloys shape memory effect microstructure phase transformations martensite cooling rate differential scanning calo-rimetry
下载PDF
The cooling and moistening effect on the formation of sea fog in the Huanghai Sea 被引量:14
2
作者 HUANG Jian ZHOU Faxiu 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2006年第2期49-62,共14页
With the sea surface observations from ICOADS for the years 1960-2002, the conditions of coohng, evaporauon anu water vapol transportation are analyzed and compared for the formation of seasonal sea fog in April-July ... With the sea surface observations from ICOADS for the years 1960-2002, the conditions of coohng, evaporauon anu water vapol transportation are analyzed and compared for the formation of seasonal sea fog in April-July in the Huanghai Sea. It is found that sea surface cooling is always existent during the fog seasons while sea surface evaporation only appears in April-June in the Huanghai Sea. Local evaporation alone is not sufficient to form fogs though it may lead to light ones. Water vapor transported from the low-latitudes accomplished by specific synoptic systems is the most important condition for sea fog formation. In general, the moistening effect is more important than the cooling one. 展开更多
关键词 sea fog in Huanghai Sea cooling effect moistening effect water vapor transportation
下载PDF
Temporal Variation in Sap-Flux-Scaled Transpiration and Cooling Effect of a Subtropical Schima superba Plantation in the Urban Area of Guangzhou 被引量:6
3
作者 ZHU Li-wei ZHAO Ping 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2013年第8期1350-1356,共7页
Agriculture could suffer the water stress induced by climate change. Because climate warming affects global hydrological cycles, it is vital to explore the effect of tree transpiration, as an important component of te... Agriculture could suffer the water stress induced by climate change. Because climate warming affects global hydrological cycles, it is vital to explore the effect of tree transpiration, as an important component of terrestrial evapotranspiration, on the environment. Thermal dissipation probes were used to measure xylem sap flux density of a Schima superba plantation in the urban area of Guangzhou City, South China. Stand transpiration was calculated by mean sap flux density times total sapwood area. The occurrence of the maximum sap flux density on the daily scale was later in wet season than in dry season. The peak of daily sap flux density was the highest of 59 g m-2 s^-1 in July and August, and the lowest of 28 g m-2 s-1 in December. In the two periods (November 2007-October 2008 and November 2008-October 2009), the stand transpiration reached 263.2 and 291.6 ram, respectively. During our study period, stand transpiration in wet season (from April to September) could account for about 58.5 and 53.8% of the annual transpiration, respectively. Heat energy absorbed by tree transpiration averaged 1.4×10s and 1.6×10s kJ per month in this Schima superba plantation with the area of 2 885 m2, and temperature was reduced by 4.3 and 4.7℃ s^-1 per 10 m3 air. 展开更多
关键词 Schima superba plantation sap flux density stand transpiration cooling effect
下载PDF
Experimental study on supersonic film cooling on the surface of a blunt body in hypersonic flow 被引量:5
4
作者 付佳 易仕和 +2 位作者 王小虎 何霖 葛勇 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期315-322,共8页
The experimental study focuses on the heat flux on a double cone blunt body in the presence of tangential-slot super- sonic injection into hypersonic flow. The tests are conducted in a contoured axisymmetric nozzle wi... The experimental study focuses on the heat flux on a double cone blunt body in the presence of tangential-slot super- sonic injection into hypersonic flow. The tests are conducted in a contoured axisymmetric nozzle with Mach numbers of 7.3 and 8.1, and the total temperature is about 900 K. The injection Mach number is 3.2, and total temperature is 300 K. A constant voltage circuit is developed to supply the temperature detectors instead of the normally used constant current circuit. The schlieren photographs are presented additionally to visualize the flow and help analyze the pressure relationship between the cooling flow and the main flow. The dependence of the film-cooling effectiveness on flow parameters, i.e. the blow ratio, the convective Mach number, and the attack angle, is determined. A semi-empirical formula is tested by the present data, and is improved for a better correlation. 展开更多
关键词 slot film cooling HYPERSONIC schlieren visualization cooling effectiveness
下载PDF
Numerical Modeling and Analysis of Grooved Surface Applied to Film Cooling 被引量:3
5
作者 L. Guo Z. C. Liu +1 位作者 Y. Y. Yan Z. W. Han 《Journal of Bionic Engineering》 SCIE EI CSCD 2011年第4期464-473,共10页
In order to improve the efficiency of film cooling, numerical investigation was carried out to study the effects of different film-cooled plates on surface heat transfer. Both grooved and non-grooved surfaces were con... In order to improve the efficiency of film cooling, numerical investigation was carried out to study the effects of different film-cooled plates on surface heat transfer. Both grooved and non-grooved surfaces were concerned. The modeling was per- formed using Fluent software with the adoption of Shear-Stress Transport (SST) k-ωmodel as the turbulence closure. The coolant was supplied by a single film cooling hole with an inclination angle of 30°. The Mach numbers for the coolant flow and the mainstream flow were fixed at 0 and 0.6, respectively. At three blowing ratios of 0.5, 1.0 and 1.5, the aerodynamic behaviour of the mixing process as well as the heat transfer performance of the film cooling were presented. The numerical results were validated using experimental data extracted from a benchmark test. Good agreements between numerical results and the ex- perimental data were observed. For the film cooling efficiency, it shows that both local and laterally averaged cooling effectiveness can be improved by the non-smooth surface at different blowing ratios. Using the grooved surface, the turbulence intensity upon the plate can be reduced notably, and the mixing between the two flows is weakened due to the reduced turbu lence level. The results indicate that the cooling effectiveness of film cooling can be enhanced by applying the grooved surface. 展开更多
关键词 film cooling non-smooth surface cooling effectiveness grooved structure blowing ratio
下载PDF
Experiment on Adiabatic Film Cooling Effectiveness in Front Zone of Effusion Cooling Configuration 被引量:3
6
作者 杨志民 张靖周 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2014年第3期338-344,共7页
Experimental investigation is performed to investigate the cooling characteristics in the front zone of effusion configuration. Effects of blowing ratio,multi-hole arrangement mode,hole-to-hole pitch and jet orientati... Experimental investigation is performed to investigate the cooling characteristics in the front zone of effusion configuration. Effects of blowing ratio,multi-hole arrangement mode,hole-to-hole pitch and jet orientation angle on the adiabatic film cooling effectiveness are concentrated on. The results show that the film layer displays an obvious"developing"feature in the front zone of effusion cooling scheme,for either the staggered or inline multi-hole arrangement. The varying gradient of the laterally-averaged adiabatic cooling effectiveness along the streamwise direction is greater for the staggered arrangement than that for the inline arrangement. The holes array arranged in staggered mode with small hole-tohole pitches is in favor of obtaining developed film coverage layer rapidly. 展开更多
关键词 effusion cooling adiabatic film cooling effectiveness front zone cooling film development
下载PDF
The cooling effect of crushed rock structures on permafrost under an embankment 被引量:5
7
作者 QingBai Wu MingYong Li YongZhi Liu 《Research in Cold and Arid Regions》 2009年第1期39-50,共12页
Based on the analysis and comparison of soil temperature, thermal regime and permafrost table under the experimental embankment of crushed rock structures in Beiluhe, results show that crushed rock structures provide ... Based on the analysis and comparison of soil temperature, thermal regime and permafrost table under the experimental embankment of crushed rock structures in Beiluhe, results show that crushed rock structures provide an extensive cooling effect, which produces a rising permafrost table and decreasing soil temperatures. The rise of the permafrost table under the embankment ranges from an increase of 1.08 m to 1.67 m, with an average of 1.27 m from 2004 to 2007. Mean annual soil temperatures under the crushed rock layer embankment decreased significantly from 2005 to 2007, with average decreases of ?1.03 °C at the depth of 0.5 m, ?1.14 °C at the depth of 1.5 m, and ?0.5 °C at the depth of 5 m. During this period, mean annual soil temperatures under the crushed rock cover embankment showed a slight decrease at shallow depths, with an average decrease of ?0.2 °C at the depth of 0.5 m and 1.5 m, but a slight rise at the depth of 5 m. After the crushed rock structures were closed or crammed with sand, the cooling effect of the crushed rock layer embankment was greatly reduced and that of the crushed rock cover embankment was just slightly reduced. 展开更多
关键词 cooling effect crushed rock structure PERMAFROST
下载PDF
Laboratory test on the combined cooling effect of L-shaped thermosyphons and thermal insulation on high-grade roadway construction in permafrost regions 被引量:3
8
作者 YuanHong Dong,YuanMing Lai,MingYi Zhang,ShuangYang Li State Key Laboratory of Frozen Soil Engineering,Cold and Arid Regions Environmental and Engineering Research Institute,Chinese Academy of Sciences,Lanzhou,Gansu 730000,China. 《Research in Cold and Arid Regions》 2009年第4期307-315,共9页
With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold... With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold regions,the thawing of permafrost can induce settlement damage of and even failure to railway (or roadway) embankments.Thermosyphons (self-powered refrigera-tion devices that are used to help keep the permafrost cool) have proved effective in mitigating thaw settlement by maintaining the thermal stability of the embankments.However,for high-grade roadway embankments of great width,stabilizing or cooling ef-fects of traditional geotechnological measures may be limited.To enhance the cooling effect of thermosyphons,an L-shaped thermosyphon was designed.A laboratory test was carried out to study the combined cooling effect of the L-shaped thermosyphon and thermal insulation applying to roadbed construction.The angle between the evaporator and condenser sections of the L-shaped thermosyphon is 134 degrees,and the L-shaped thermosyphon was inserted into the soil at an angle of 5 degrees with the road surface.The tested results show that the L-shaped thermosyphon is effective in removing heat from a roadway in winter.When the ambient air temperature is lower than the soil temperature,the thermosyphon is active and extracts the heat in the soil around it.When the ambient air temperature is higher than the soil temperature,the thermosyphon is inactive,and no heat is in-jected into the soil through the L-shaped thermosyphon.Compared to embankments with straight thermosyphons,the inner parts of the embankments with L-shaped thermosyphons were significantly cooled.It is hoped that the present study would be useful to the application of L-shaped thermosyphons in the construction of high-grade roadways in cold regions. 展开更多
关键词 L-shaped thermosyphon thermal insulation cooling effect foundation soils high-grade roadway
下载PDF
Cooling effect of convection-intensifying composite embankment with air doors on permafrost
9
作者 Hong Sun XiuRun Ge +2 位作者 FuJun Niu Ge Liu JinZhao Zhang 《Research in Cold and Arid Regions》 CSCD 2014年第4期372-377,共6页
One of the main construction problems in permafrost regions is protecting permafrost thermal stability. Although ventilating ducts and crushed-rock layers were successfully used in railway embankment construction, the... One of the main construction problems in permafrost regions is protecting permafrost thermal stability. Although ventilating ducts and crushed-rock layers were successfully used in railway embankment construction, their effects might not meet large-width expressway requirements. The convection-intensifying composite embankment composed of perforated ventilation ducts and crushed-rock layers was numerically studied to investigate its cooling effects. Adopting a numerical model, the temperature fields for two kinds of composite embankment with and without air doors were analyzed considering air flow and heat transfer characteristics in porous media. The results show that wind velocity in the crushed-rock zone is intensified by the perforated ventilation duct. The underlying permafrost temperature obviously decreases, and the 0 °C isotherm position rises significantly due to composite embankment. The composite embankment with air doors is more effective than that without air doors. Therefore, the new convection-intensifying composite embankment is potentially a highly efficient cooling measure for construction in permafrost regions. 展开更多
关键词 cooling effect composite embankment PERMAFROST convection-intensifying air doors
下载PDF
Hybrid RANS-LES of Shaped Hole Film Cooling on an Adiabatic Flat Plate at Low Reynolds Number
10
作者 Michael Boehler Akshay Sudesh Mark Turner 《Open Journal of Fluid Dynamics》 2020年第4期317-341,共25页
Hybrid RANS-LES methods offer a means of reducing computational cost and setup time to simulate transitional flows. Several methods are evaluated in ANSYS CFX, including Scale-Adaptive Simulation (SAS), Shielded Detac... Hybrid RANS-LES methods offer a means of reducing computational cost and setup time to simulate transitional flows. Several methods are evaluated in ANSYS CFX, including Scale-Adaptive Simulation (SAS), Shielded Detached Eddy Simulation (SDES), Stress-Blended Eddy Simulation (SBES), and Zonal Large Eddy Simulation (ZLES), along with a no-model laminar simulation. Each is used to simulate an adiabatic flat plate film cooling experiment of a shaped hole at low Reynolds number. Adiabatic effectiveness is calculated for Blowing Ratio (BR) = 1.5 and Density Ratio (DR) = 1.5. The ZLES method and laminar simulation most accurately match experimental lateral-average adiabatic effectiveness along the streamwise direction from the trailing edge of the hole to 35 hole diameters downstream of the hole (X/D = 0 to X/D = 35), with RMS deviations of 5.1% and 4.2%, and maximum deviations of 8% and 11%, respectively. The accuracy of these models is attributed to the resolution of turbulent structures in not only the mixing region but in the upstream boundary layer as well, where the other methods utilize RANS and do not switch to LES. 展开更多
关键词 Film cooling Large Eddy Simulation Detached-Eddy Simulation Stress-Blended Eddy Simulation Laidback Fan-Shaped cooling Hole Film cooling Effectiveness
下载PDF
Analysis of Film Cooling Effectiveness on Shaped Hole and Antivortex Hole
11
作者 MAY Kyu Kyu Soe 《Computer Aided Drafting,Design and Manufacturing》 2010年第2期30-35,共6页
Film cooling is introduction of a secondary fluid (coolant or injected fluid) at one or more discrete locations along a surface exposed to a high temperature environment to protect that surface not only in the immed... Film cooling is introduction of a secondary fluid (coolant or injected fluid) at one or more discrete locations along a surface exposed to a high temperature environment to protect that surface not only in the immediate region of injection but also downstream region. This paper numerically investigated the film cooling effectiveness on two types of hole geometries which are cut-shaped hole and antivortex hole. The 3D computational geometries are modeled with a single 30 deg angled hole on a flat surface. The different blowing ratios of 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5,5 and k-Epsilon turbulence model are used in this study. A two dimensional distribution of film cooling effectiveness in the downstream region of the cooling hole is performed. A comparison of spanwise averaged effectiveness is also performed in the field starts from center point of hole to X/D=-30. 展开更多
关键词 turbine blade film cooling shaped hole antivortex hole film cooling effectiveness blowing ratio k-Epsilon turbulence model.
下载PDF
A Thermal Analogue of the Zel’Dovich Effect
12
作者 Gianpaolo Bei 《Journal of Applied Mathematics and Physics》 2023年第12期3970-3983,共14页
We analyze in this work anisotropic heat conduction induced by a harmonically oscillating laser source incident on rotating conductors, exploiting an analogy with an effect discovered long ago, called the Zel’dovich ... We analyze in this work anisotropic heat conduction induced by a harmonically oscillating laser source incident on rotating conductors, exploiting an analogy with an effect discovered long ago, called the Zel’dovich effect. We re-covered the main results of a recently published paper that predicts the translational Doppler frequency shift of a thermal wave induced on a sample moving with uniform rectilinear motion. We extend then this framework to take into account the frequency shift of a thermal field propagating on a rotating platform. We show that it coincides with the rotational frequency shift which has been recently observed on surface acoustic waves and hydrodynamic surface waves, called rotational superradiance. Finally, we use an analogy with the Tolman effect to deduce a simple estimate of the average temperature gradient induced by rotation, showing the existence of a new cooling effect associated with heat torque transfer. 展开更多
关键词 Anisotropic Heat Diffusion Chiral Spinning Thermal Waves Heat Vortex Beams Thermal Doppler Effect Thermal Zel’dovich Effect Thermal Polarization Vector Rotation Induced Tolman cooling Effect
下载PDF
二氧化碳射流下孔型对气膜冷却特性影响的实验研究(英文) 被引量:1
13
作者 李广超 朱惠人 樊慧明 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2008年第5期393-401,共9页
This article presents the data about heat transfer coefficient ratios, film cooling effectiveness and heat loads for the injection through cylindrical holes, 3-in-1 holes and fanned holes in order to characterize the ... This article presents the data about heat transfer coefficient ratios, film cooling effectiveness and heat loads for the injection through cylindrical holes, 3-in-1 holes and fanned holes in order to characterize the film cooling performance downstream of a row of holes with 45° inclination and 3 hole spacing apart. The trip wire is placed upstream at a distance of 10 times diameter of the cooling hole from the hole center to keep mainstream fully turbulent. Both inlet and outlet of 3-in-1 holes have a 15° lateral expansion. The outlet of fanned holes has a lateral expansion. CO2 is applied for secondary injection to obtain a density ratio of 1.5. Momentum flux ratio varies from 1 to 4. The results indicate that the increased momentum flux ratio significantly increases heat transfer coefficient and slightly improve film cooling effectiveness for the injection through cylindrical holes. A weak dependence of heat transfer coefficient and film cooling effectiveness, respectively, on momentum flux ratio has been identified for the injection through 3-in-1 holes. The in- crease of the momentum flux ratio decreases heat transfer coefficient and significantly increases film cooling effectiveness for the injection through fanned holes. In terms of the film cooling performance, the fanned holes are the best while the cylindrical holes are the worst among the three hole shapes under study. 展开更多
关键词 aerospace propulsion system gas turbine film cooling effectiveness heat transfer coefficient
下载PDF
Characteristics of the Heat Island Effect in Shanghai and Its Possible Mechanism 被引量:17
14
作者 陈隆勋 朱文琴 +1 位作者 周秀骥 周自江 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2003年第6期991-1001,共11页
The characteristics of the urban heat island effect and the climate change in Shanghai and its possible mechanism are analyzed based on monthly meteorological data from 1961 to 1997 at 16 stations in Shanghai and its ... The characteristics of the urban heat island effect and the climate change in Shanghai and its possible mechanism are analyzed based on monthly meteorological data from 1961 to 1997 at 16 stations in Shanghai and its adjacent areas. The results indicate that Shanghai City has the characteristics of a heat island of air temperature and maximum and minimum air temperature, a cold island of surface soil temperature, a weak rainy island of precipitation, and a turbid island of minimum visibility and aerosols, with centers at or near Longhua station (the urban station of Shanghai). Besides theses, the characteristics of a cloudy island and sunshine duration island are also obvious, but their centers are located in the southern part of the urban area and in the southern suburbs. A linear trend analysis suggests that all of the above urban effects intensified from 1961 to 1997. So far as the heat island effect is concerned, the heat island index (difference of annual temperature between Longhua and Songjiang s 展开更多
关键词 Shanghai heat island climate change due to economic development cooling effect due to clouds and aerosols rainy island turbid island
下载PDF
In-situ testing study on convection and temperature characteristics of a new crushed-rock slope embankment design in a permafrost region 被引量:4
15
作者 MingHao Liu FuJun Niu +3 位作者 JianHong Fang ZhanJu Lin Jing Luo GuoAn Yin 《Research in Cold and Arid Regions》 CSCD 2014年第4期378-387,共10页
For the purpose of enhancing air convection and controlling solar radiation, a new crushed-rock slope embankment design combined with a sun-shade measure is proposed. A newly designed embankment was constructed in the... For the purpose of enhancing air convection and controlling solar radiation, a new crushed-rock slope embankment design combined with a sun-shade measure is proposed. A newly designed embankment was constructed in the Tuotuohe section of the Qinghai-Tibet Railway and a field-testing experiment was carried out to determine its convection and temperature characteristics. The results show that distinct air convection occurred in the crushed-rock layer of the new embankment, especially in cold seasons, which was enhanced when it flowed upwards along the slope. This preliminarily indicated that the new design of the embankment slope was good for reinforcing air convection in the crushed-rock layer. The frequent fluctuations of the convection speed and the environmental wind speed were in good agreement, suggesting that the convection in the crushed rock primarily came from the ambient wind. It was also preliminarily determined that the new embankment had a better cooling effect and sun-shade effect for decreasing the temperature of the embankment slope compared with a traditional crushed-rock slope embankment, and the mean temperature difference between them was up to 1.7 °C. The mean annual temperature at the bottom boundary of the crushed-rock layer was obviously lower than that at the top boundary, and heat flux calculation showed that the shallow soil beneath the embankment slope was weakly releasing heat, all of which indicated that the new embankment slope design was beneficial to the thermal stability of the embankment. This study is helpful in providing some references for improved engineering design and maintenance of roadbeds in permafrost regions. 展开更多
关键词 permafrost region railway embankment slope structure air convection characteristics cooling effect
下载PDF
Effects of Injection Angles and Aperture Ratios on Film Cooling Performance of Sister Holes 被引量:2
16
作者 LI Mingchun HE Yeguang +1 位作者 LI Rundong YANG Tianhua 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第2期716-728,共13页
In this paper,to analyze the influences of the injection angles and aperture ratios (AR) of the primary hole and the side hole on the film cooling performance of a flat plate model,pressure sensitive paint (PSP) techn... In this paper,to analyze the influences of the injection angles and aperture ratios (AR) of the primary hole and the side hole on the film cooling performance of a flat plate model,pressure sensitive paint (PSP) technology was used to study the forward and backward jet of a single hole and four sister holes,and a numerical simulation was supplemented to explore the flow structure of the sister holes.The sister holes had a better film cooling performance than the cylindrical hole at all blowing ratios (BR).The backward jet of the primary hole or the side hole could increase the spanwise film coverage of the sister hole.In this study,with the primary hole featuring a backward jet and the side hole featuring a forward jet,the film cooling performance was the best,11.9 times higher than the areal mean film cooling efficiency of the cylindrical hole when AR=1 and BR=1.5.At a low blowing ratio,the counter-rotating vortex pair (CRVP) of the side hole could suppress the strength of the CRVP of the primary hole.At a high blowing ratio,when the primary hole featured a backward jet and the side hole featured a forward jet,the CRVP of the side hole had the optimal performance for suppressing the CRVP of the primary hole. 展开更多
关键词 sister hole injection angle aperture ratio film cooling effectiveness vorticity distribution
原文传递
Interannual Weakening of the Tropical Pacific Walker Circulation Due to Strong Tropical Volcanism 被引量:1
17
作者 Jiapeng MIAO Tao WANG +1 位作者 Huijun WANG Jianqi SUN 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2018年第6期645-658,共14页
In order to examine the response of the tropical Pacific Walker circulation(PWC) to strong tropical volcanic eruptions(SVEs), we analyzed a three-member long-term simulation performed with Had CM3, and carried out... In order to examine the response of the tropical Pacific Walker circulation(PWC) to strong tropical volcanic eruptions(SVEs), we analyzed a three-member long-term simulation performed with Had CM3, and carried out four additional CAM4 experiments. We found that the PWC shows a significant interannual weakening after SVEs. The cooling effect from SVEs is able to cool the entire tropics. However, cooling over the Maritime Continent is stronger than that over the central-eastern tropical Pacific. Thus, non-uniform zonal temperature anomalies can be seen following SVEs. As a result, the sea level pressure gradient between the tropical Pacific and the Maritime Continent is reduced, which weakens trade winds over the tropical Pacific. Therefore, the PWC is weakened during this period. At the same time, due to the cooling subtropical and midlatitude Pacific, the Intertropical Convergence Zone(ITCZ) and South Pacific convergence zone(SPCZ) are weakened and shift to the equator. These changes also contribute to the weakened PWC. Meanwhile, through the positive Bjerknes feedback, weakened trade winds cause El Nino-like SST anomalies over the tropical Pacific, which in turn further influence the PWC. Therefore, the PWC significantly weakens after SVEs. The CAM4 experiments further confirm the influences from surface cooling over the Maritime Continent and subtropical/midlatitude Pacific on the PWC. Moreover, they indicate that the stronger cooling over the Maritime Continent plays a dominant role in weakening the PWC after SVEs. In the observations,a weakened PWC and a related El Nino-like SST pattern can be found following SVEs. 展开更多
关键词 Pacific Walker circulation strong tropical volcanic eruptions cooling effect trade winds
下载PDF
Experimental Study of Heat Transfer and Film Cooling Performance of Upstream Ejected Coolant on a Turbine Endwall 被引量:1
18
作者 ZHANG Jie LIU Cunliang +2 位作者 ZHANG Li YAO Chunyi LI Lin 《Journal of Thermal Science》 SCIE EI CAS CSCD 2023年第2期718-728,共11页
An upstream coolant injection that is different from the known leakage flow was introduced to protect the turbine endwall.This coolant is ejected tangentially from a row of cylindrical holes situated at the side of a ... An upstream coolant injection that is different from the known leakage flow was introduced to protect the turbine endwall.This coolant is ejected tangentially from a row of cylindrical holes situated at the side of a backward-facing step.In this experiment,the effects of mass flow ratio and leakage slot width on the endwall heat transfer characteristics were investigated.The dimensionless heat transfer coefficient(Nu)and adiabatic film cooling effectiveness(η)on an axisymmetric turbine endwall were measured by the stable-state thermochromic liquid crystal(TLC)technique and the pressure sensitive paint(PSP)technique,respectively.Three mass flow ratios(MFR)of 0.64%,0.85%,and 1.07%,as well as two leakage slot widths(W)of 3.93 mm,and 7.86 mm were considered.Results indicate that the injection film suppresses the strength of the passage vortex,which leads to the coolant covering almost the entire endwall.This result is more evident for the higher MFR cases,meanwhile,the corresponding averaged film cooling effectiveness is increased with the enhancement of the MFR.However,the case with a higher MFR produces a higher heat transfer coefficient distribution,especially in the region close to the leakage slot edge.Besides,when the W is lower,the endwall presents a higherηand a lower Nu for all the cases,which can guide the optimal design of the endwall. 展开更多
关键词 axisymmetric turbine endwall film cooling effectiveness heat transfer coefficient coolant injection leakage slot
原文传递
Optimization of the Water-Cooled Structure for the Divertor Plates in EAST Based on an Orthogonal Theory
19
作者 李磊 姚达毛 +3 位作者 刘常乐 周自波 曹磊 梁超 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第5期435-440,共6页
An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and ... An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and L3. The influence rule of different factors on the cooling effect and thermal stress of the plate were studied, for which the influence rank was respectively R 〉 L1 〉 L3 and L3 〉 R 〉 L1. The highest temperature value decreased when R and L1 increased~ and the maximum thermal stress value dropped when R, L1 and L3 increased. The final optimized results can be summarized as: R equals 6 mm or 7 mm, L1 equals 19 mm, and L3 equals 20 mm. Compared with the initial design, the highest temperature value had a small decline~ and the maximum thermal stress value dropped by 19~ to 24~. So it was not ideal to improve the cooling effect by optimizing the geometry sizes of the water-cooled structure, even worse than increasing the flow speed, but it was very effective for dropping the maximum thermal stress value. The orthogoaal experimental method reduces the number of experiments by 80%, and thus it is feasible and effective to optimize the water-cooled structure of the divertor plate with the orthogonal theory. 展开更多
关键词 orthogonal theory divertor plate water-cooled structure cooling effect thermal stress OPTIMIZATION
下载PDF
Mesoscale wind stress-SST coupling induced feedback to the ocean in the western coast of South America
20
作者 Chaoran CUI Rong-Hua ZHANG +1 位作者 Yanzhou WEI Hongna WANG 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2021年第3期785-799,共15页
The feedback induced by mesoscale wind stress-SST coupling to the ocean in the western coast of South America was studied using the Regional Ocean Modeling System(ROMS).To represent the feedback,an empirical mesoscale... The feedback induced by mesoscale wind stress-SST coupling to the ocean in the western coast of South America was studied using the Regional Ocean Modeling System(ROMS).To represent the feedback,an empirical mesoscale wind stress perturbation model was constructed from satellite observations,and was incorporated into the ocean model.Comparing two experiments with and without the mesoscale wind stress-SST coupling,it was found that SST in the mesoscale coupling experiment was reduced in the western coast of South America,with the maximum values of 0.5℃in the Peru Sea and 0.7℃in the Chile Sea.A mixed layer heat budget analysis indicates that horizontal advection is the main term that explains the reduction in SST.Specifically,the feedback induced by mesoscale wind stress-SST coupling to the ocean can enhance vertical velocity in the nearshore area through the Ekman pumping,which brings subsurface cold water to the sea surface.These results indicate that the feedback due to the mesoscale wind stress-SST coupling to the ocean has the potential for reducing the warm SST bias often seen in the large-scale climate model simulations in this region. 展开更多
关键词 mesoscale air-sea coupling western coast of South America ocean model simulations cooling effect warm bias
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部