Complexation combined with supercritical fluid extraction was used to extract Cu2+ in this study. The effects of pressure, temperature, volume of CO2 on the efficiency of extraction were systematically investigated. A...Complexation combined with supercritical fluid extraction was used to extract Cu2+ in this study. The effects of pressure, temperature, volume of CO2 on the efficiency of extraction were systematically investigated. At the optimum condition a 57.32% recovery was achieved. Addition of suitable amount of methanol (v/v = 5%) to the supercritical CO2 can increase in the extraction of Cu2+ (72.69%, RSD = 2.12%, n = 3). And the recovery can further increase in the presence of non-ionic surfactant Triton X-100 because of its function of solubilization. Surfactant was first used in the extraction of metal ions in the present study, and the results are satisfied (90.52%, RSD = 2.20%, n = 3).展开更多
文摘Complexation combined with supercritical fluid extraction was used to extract Cu2+ in this study. The effects of pressure, temperature, volume of CO2 on the efficiency of extraction were systematically investigated. At the optimum condition a 57.32% recovery was achieved. Addition of suitable amount of methanol (v/v = 5%) to the supercritical CO2 can increase in the extraction of Cu2+ (72.69%, RSD = 2.12%, n = 3). And the recovery can further increase in the presence of non-ionic surfactant Triton X-100 because of its function of solubilization. Surfactant was first used in the extraction of metal ions in the present study, and the results are satisfied (90.52%, RSD = 2.20%, n = 3).