OBJECTIVE To evalu ate the role of resting magnetocardiography in identifying seve re coronary artery stenosis in patients with suspected coronary artery disease.METHODS A total of 513 patients with angina symptoms we...OBJECTIVE To evalu ate the role of resting magnetocardiography in identifying seve re coronary artery stenosis in patients with suspected coronary artery disease.METHODS A total of 513 patients with angina symptoms were included and divided into two groups based on the extent of coronary artery disease determined by angiography:the non-severe coronary stenusis group(<70% stenosis) and the severe coronary stenosis group(≥70% stenosis).The diagnostic model was constructed using magnetic field map(MFM) parameters,either individually or in combination with clinical indicators.The performance of the models was evaluated using receiver operating characteristic curves,accuracy,sensitivity,specificity,positive predictive value(PPV) and ne gative predictive value(NPV).Calibration plots and decision curve analysis were performed to investigate the clinical utility and performance of the models,respectively.RESULTS In the severe coronary stenosis group,QR_MCTDd,S_MDp,and TT_(MA)C_(50) were significantly higher than those in the non-severe coronary stenosis group(10,46±10.66 vs,5.11±6.07,P <0.001;7.2±8.64 vs.4.68±6.95,P=0.003;0.32±57.29 vs.0.26±57.29,P <0.001).While,QR_MV_(amp),R_(MA),and T_(MA) in the severe coronary stenosis group were lower(0.23±0.16 vs.0.28±0.16,P<0.001;55.06±48.68 vs.59.24±53.01,P<0.001;51.67±39.32 vs. 60.45±51.33,P <0.001).Seven MFM parameters were integrated into the model,resulting in an area under the curve of 0.810(95% CI:0.765-0.855).The sensitivity,specificity,PPV,NPV,and accurecy were 71.7%,80.4%,93.3%,42.8 %,and 73.5%;respectevely.The combined model exhibited an area under the curve of 0.845(95% CI:0.798-0.892).The sensitivity,specificity,PPV,NPV,and accuracy were 84.3%,73.8%,92.6%,54.6%,and 82.1%;respectively.Calibration curves demonstrate d excellent agreement between the nomogram prediction and actual observation.The decision curve analysis showed that the c ombine d model provided greater net benefit compared to the magnetocardingraphy model.CONCLUSIONS The novel quantitative MFM parameters,whether used individually or in combination with clinical indicators,have been shown to effectively pre dict the risk of severe coronary stenosis in patients presenting with angina-like symptoms.Magnetocardiography,an emerging non-invasive diagnostic tool,warrants further exploration for its potential in diagnosing coronary heart disease.展开更多
Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base...Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.展开更多
BACKGROUND Coronary artery stenosis(CAS)is the most common type of heart disease and the leading cause of death in both men and women globally.CAS occurs when the arteries that supply blood to the heart muscle harden ...BACKGROUND Coronary artery stenosis(CAS)is the most common type of heart disease and the leading cause of death in both men and women globally.CAS occurs when the arteries that supply blood to the heart muscle harden and become narrower due to plaque buildup-cholesterol and other material-on their inner walls.As a result,the heart muscle cannot receive the blood or oxygen it needs.Most heart attacks happen when a blood clot suddenly cuts off the hearts'blood supply,causing permanent heart damage.AIM To analyze the relationship between the left ventricular ejection fraction(LVEF),left ventricular strain(LVS),and coronary stenosis.METHODS A total of 190 participants were enrolled in this trail.The control group comprised 93 healthy individuals,and observation group comprised 97 patients with coronary heart disease who were hospitalized between July 2020 and September 2021.Coronary lesions were assessed using the Gensini score,and the LVEF and LVS were measured using magnetic resonance imaging(MRI).The interaction between the LVEF and LVS was examined using a linear regression model.The relationship between LVEF and coronary stenosis was examined using Spearman’s correlation.RESULTS The LVEF of the observation group was lower than that of the control group.The left ventricular end-systolic volume(LVESV)and left ventricular end-diastolic volume(LVEDV)of the observation group were significantly higher than those of the control group(P<0.05).The longitudinal and circumferential strains(LS,CS)of the observation group were significantly higher than those of the control group;however,the radial strain(RS)of the observation group was significantly lower than that of the control group(P<0.05).LVS,LS,and CS were significantly negatively correlated with the LVEF,and RS was positively correlated with the LVEF.There were significant differences in the LVEF,LVESV,and LVEDV of patients with different Gensini scores;the LVEF significantly decreased and the LVESV and LVEDV increased with increasing Gensini scores(P<0.05).In the observation group,the LVEF was negatively correlated and the LVESV and LVEDV were positively correlated with coronary stenosis(P<0.05).CONCLUSION The LVEF measured using MRI is significantly linearly correlated with LVS and negatively correlated with coronary stenosis.展开更多
Objective:To analyze the imaging effect and accuracy of 64-slice spiral CT in the diagnosis of coronary artery stenosis.Methods:30 patients with suspected coronary heart disease admitted to our hospital from March 202...Objective:To analyze the imaging effect and accuracy of 64-slice spiral CT in the diagnosis of coronary artery stenosis.Methods:30 patients with suspected coronary heart disease admitted to our hospital from March 2022 to March 2023 were selected.All patients underwent both 64-slice spiral CT and digital subtraction angiography(DSA).DSA is considered the gold standard for diagnosis,so it was used to analyze the diagnostic performance of 64-slice spiral CT.Results:(1)The diagnostic results of digital subtraction angiography and 64-slice spiral CT was analyzed and compared with each other.The 64-slice spiral CT had an accuracy of 96.67%(29/30),a sensitivity 96.55%(28/29),and a specificity of 100.00%(1/1)in diagnosing coronary artery stenosis.(2)There was no significant difference between 64-slice spiral CT and digital subtraction angiography in the positive detection rate of anterior descending artery lesion,the positive detection rate of left main lesion,the positive detection rate of left circumflex artery lesion and the positive detection rate of right coronary artery lesion(P>0.05).(3)There was no significant difference between 64-slice spiral CT examination and DSA examination in identifying mild stenosis,moderate stenosis,and severe stenosis of coronary arteries(P>0.05).Conclusion:64-slice spiral CT examination can accurately determine the degree of occlusion of coronary arteries,which allows for the accurate diagnosis of coronary artery stenosis.展开更多
Objective To explore the safety and efficacy of FFR-guided percutaneous coronary intervention (PCI) in vessels with severe diameter stenosis. Methods & Results Of 1090 patients undergoing fractional flow reserve (...Objective To explore the safety and efficacy of FFR-guided percutaneous coronary intervention (PCI) in vessels with severe diameter stenosis. Methods & Results Of 1090 patients undergoing fractional flow reserve (FFR) assessment from 2002 to 2009,we identified 167 patients in whom FFR was measured in at least one 70%–89% stenotic lesion. These patients were subdivided into an FFR-defer group (n = 49) if PCI was deferred (FFR > 0.80),and an FFR-perform group (n = 118) if PCI was performed (FFR ≤ 0.80). Comparatively,an additional 1176 patients undergoing PCI in at least one lesion with 70%–89% stenosis but without measurement of FFR served as a control (angiography- guided) group. Clinical outcomes were compared during a median follow-up of 49.0 months. The 5-year Kaplan-Meier estimated revascularization rates were 16% in the FFR-defer group and 33% in the FFR-perform group (P = 0.046). The incidence of major adverse cardiac events were comparable in these two groups (HR = 0.82,95% CI: 0.37–1.82,P = 0.63). The number of stents placed was significantly lower in the FFR-guided group (0.9 ± 0.8 vs. 1.4 ± 0.8,P < 0.001). Conclusions Functional revascularization for lesions with visually severe stenosis is clinically safe and associated with fewer stents use. This study suggests that extending the use of FFR to more severe coronary lesions may be reasonable.展开更多
Aim:Intracoronary murmur results from turbulent flow due to coronary artery narrowing.This study evaluated the diagnostic performance of a method for acoustic analysis of turbulent murmur caused by coronary artery ste...Aim:Intracoronary murmur results from turbulent flow due to coronary artery narrowing.This study evaluated the diagnostic performance of a method for acoustic analysis of turbulent murmur caused by coronary artery stenosis in coronary artery disease(CAD)in Chinese populations.Method:Patients admitted to the cardiovascular department of the Sixth Medical Center of the Chinese People’s Liberation Army General Hospital between September 2021 and June 2022 for elective coronary angiography were prospectively enrolled.A digital electronic stethoscope was used to record heart sounds before angiography.Quantitative coronary angiography(QCA)served as the“gold standard”for CAD diagnosis to evaluate the diagnostic performance of the acoustic analysis method for CAD.Results:A total of 452 patients had complete QCA and heart sound data.The final interpretation results of the acoustic analysis method indicated 310 disease cases and 142 normal results.Increasing the cut-off values of coronary artery diameter stenosis from 30%to 50%,70%,and 90%increased the sensitivity and NPV of the acoustic analysis method;the sensitivity was 75.6%,81.9%,83.3%,and 85.7%,respectively;the NPV was 33.1%,57.0%,69.7%,and 88.0%,respectively;the specificity and PPV decreased(specificity of 75.8%,70.4%,51.0%,and 37.5%,respectively;PPV of 95.2%,89.0%,69.4%,and 32.9%,respectively);and the AUC values were 0.757,0.762,0.672,and 0.616,respectively.The sensitivity of the acoustic analysis method for one-vessel disease was 86.6%when the cut-off value was 50%.The sensitivity for identifying left anterior descending coronary artery lesions was best,at 90.7%.The sensitivity for identifying isolated coronary artery branch lesions was 66.7%,whereas the sensitivity for identifying three-vessel disease in multi-vessel coronary artery lesions was better,at 82.9%.Conclusion:Acoustic analysis of turbulent murmur caused by coronary artery stenosis for diagnosis of CAD may have favorable performance in the Chinese population.This method has good performance in CAD diagnosis with a cut-off coronary artery diameter for stenosis of 50%.展开更多
Background: The association of right coronary artery (RCA) stenosis in patients undergoing myocardial revascularization for left main coronary artery (LMCA) stenosis affects the prognosis. This study aimed to compare ...Background: The association of right coronary artery (RCA) stenosis in patients undergoing myocardial revascularization for left main coronary artery (LMCA) stenosis affects the prognosis. This study aimed to compare immediate results of patients with isolated LMCA stenosis and those with combined RCA stenosis. Patients and methods: We retrospectively evaluated 107 consecutive patients with LMCA disease who underwent coronary artery bypass grafts. The patients were divided into two groups: isolated LMCA stenosis (n = 36) and LMCA stenosis + RCA stenosis (n = 71). Different variables (preoperative, intra operative and post operative) were compared. Results: Patients with LMCA stenosis + RCA stenosis experienced higher prevalence of diabetes mellitus (p = 0.024) and smoker (p = 0.032). Also left ventricular EF was reduced (p = 0.004). Myocardial revascularization was more complete in patients with LMCA stenosis + RCA stenosis (p = 0.033), but in-hospital mortality rate was higher (12.6% vs 5.5%) in isolated LLMCA stenosis, but it did not reach statistical significance (p = 0.32). Except low output syndrome (LOS) that was frequent in presence of RCA stenosis (p = 0.026), no significant difference was found between groups for other complications. Conclusion: The presence of RCA stenosis in patients undergoing CABG for LMCA disease increases 30 day mortality but without significant impact on overall morbidities.展开更多
Objective Biochemical indicators such as N-terminal pro-brain type natriuretic peptide(NT pro-BNP)and high-sensitivity Creactive protein(hsCRP)predict mortality in acute coronary syndrome(ACS).However,little is ...Objective Biochemical indicators such as N-terminal pro-brain type natriuretic peptide(NT pro-BNP)and high-sensitivity Creactive protein(hsCRP)predict mortality in acute coronary syndrome(ACS).However,little is known about the relationship of these factors with severity of coronary artery stenosis in patients with.Methods Three hundred and thirty-one subjects including 246 unstable angina pectoris patients and 85 myocardial infarction patients were recruited and classified into two groups:single-vessel disease group(1-vessel disease,n=93)and multiple-vessel disease group(≥2-vessels disease,n=238)according to selective coronary angiography.Plasma levels of NT pro-BNP and hsCRP were measured and severity of coronary stenosis was determined by Gensini score.Results NT pro-BNP but not hsCRP level was higher in patients with myocardial infarction than in patients with unstable angina pectoris.The patients with multiple-vessel disease had significantly higher NT pro-BNP level but not hsCRP compared with those with single-vessel disease.NT pro-BNP levels increased significantly as left ventricle(LV)function decreased,and only NT proBNP but not hsCRP level was related to Gensini score of severity of coronary stenosis in ACS.Conclusion NT proBNP but not hsCRP level is related to severity of coronary artery stenosis in patients in ACS.展开更多
Coronary angiography is considered to be the gold standard in the morphological evaluation of coronary artery stenosis. The morphological assessment of the severity of a coronary lesion is very subjective. Thus, the i...Coronary angiography is considered to be the gold standard in the morphological evaluation of coronary artery stenosis. The morphological assessment of the severity of a coronary lesion is very subjective. Thus, the invasive fractional flow reserve(FFR) measurement represents the current standard for estimation of the hemodynamic significance of coronary artery stenosis. The FFR-guided revascularization strategy was initially classified as a Class-IA-recommendation in the 2014 European Society of Cardiology/European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. Both the Deferral vs Performance of Percutaneous Coronary Intervention of Functionally Non-Significant Coronary Stenosis and Flow Reserve vs Angiography for Multivessel Evaluation studies showed no treatment advantage for hemodynamically insignificant stenoses. With the help of FFR(and targeted interventions), clinical results could be improved; however, the use in clinical practice is still limited due to the need of adenosine administration and a significant prolongation of the length of the procedure. Instantaneous wave-free ratio(iFR~) is a new innovative approach for the determination of the hemodynamic significance of coronary stenosis, which can be obtained at rest without the use of vasodilators. Regarding the periprocedural complications as well as prognosis, iFR~ showed non-inferiority to FFR in the SWEDEHEART and DEFINE-FLAIR trials. Furthermore, iFR~, enhanced by iFR~-pullback, provides the possibility to display the iFR~-change over the course of the vessel to create a hemodynamic map.展开更多
AIM To investigate the relationship between coronary calcium score(CCS) and vulnerable plaque/significant stenosis using coronary computed tomographic angiography(CCTA). METHODS CCTA was performed in 651 patients and ...AIM To investigate the relationship between coronary calcium score(CCS) and vulnerable plaque/significant stenosis using coronary computed tomographic angiography(CCTA). METHODS CCTA was performed in 651 patients and these patients were divided into the four groups(CCS 0, 1-100, 101-400 and > 400). We studied the incidence of high-risk plaque, including positive remodeling, low attenuation plaque, spotty calcification, and napkin-ring sign, and significant stenosis in each group. RESULTS High-risk plaque was found in 1.3%, 10.1%, 13.3% and 13.4% of patients with CCS 0, 1-100, 101-400 and > 400, respectively(P < 0.001). The difference was only significant for patients with zero CCS. The incidence of significant stenosis was 0.6%, 7.6%, 13.3% and 26.9% for each patient group, respectively(P < 0.001), which represented a significant stepwise increase as CCS increased. The combined incidence of high-risk plaque and significant stenosis was 1.9%, 17.7%, 26.9% and 40.3% in each patient group, respectively(P < 0.001), again representing a significant stepwise increase with CCS. The rate of major coronary event was 0%, 4.0%, 7.9% and 17.2% in each patient group, respectively(P < 0.001), another significant stepwise increase as CCS increased. CONCLUSION Stepwise increased risk of coronary events associated with increasing CCS is caused by increasing incidence of significant stenosis, while that of high-risk plaque remains the same.展开更多
The purpose of this paper is to study the changes of deformabilityof erythrocytes and 2.3-DPG(2.3-diphosphoglycerate acid)in the patients with coro-nary artery stenosis and the effects of some factors on them.It is sh...The purpose of this paper is to study the changes of deformabilityof erythrocytes and 2.3-DPG(2.3-diphosphoglycerate acid)in the patients with coro-nary artery stenosis and the effects of some factors on them.It is showed that:de-formability of crythrocyte and 2.3-DPG were inversely proportional to the degreeof the lesions of coronary vessels(P【0.01);there was a significant decrease of de-formability of erythrocytes after using contract agents(P【0.01);Salvia increaseddeformability and 2.3-DPG significantly(P【0.01).In conclusion,our data suggestthat the possible existence of microcirculation dysfunction in coronary artery dis-eases with parallelism to the impairement deformability of erythrocytcs and Salviabca good drug to action in deformability and 2.3 DPG in patients.展开更多
The role of 16-slice spiral CT was selective X-ray coronary angiography (SCA) who were suspected of having coronary heart evaluated in the diagnosis of coronary stenosis, with serving as the reference standard. Sixt...The role of 16-slice spiral CT was selective X-ray coronary angiography (SCA) who were suspected of having coronary heart evaluated in the diagnosis of coronary stenosis, with serving as the reference standard. Sixty-five patients disease, without percutaneous transluminal coronary angioplasty or coronary bypass-grafting, were investigated using 16-slice CT. Eight patients with pre-scan heart rate of more than 80 beats/min were given β-blockers. After the retrospectively ECG-gated axial imaging reconstruction, volume redering (VR), multi-planar reconstruction (MPR), curved MPR and maximum intensity projection (MIP) were used to reconstruct. Every segment of coronary artery with a diameter ≥1.5 mm was assessed, and the presence on CT with a stenosis exceeding 50 % diameter reduction was compared with that on SCA. The reasons which lead to some segments unevaluable were analysed. Compared with SCA, 93 % coronary segments and 94 % main branches were evaluable. Residual cardiac motion artifacts, severe calcification and poor opacification made 58 %, 28 % and 14 % of the remaining 60 segments unevaluable respectively. Without routine administration of β-blockers, good coronary imaging quality can be acquired using 16-slice spiral CT. It is a reliable noninvasive method for detection of obstructive coronary artery disease.展开更多
Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left...Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery.展开更多
BACKGROUND Intermediate coronary lesions(ICLs)are highly prevalent but ported mixed prognosis.Radial strain has been associated with plaque vulnerability,yet its role in predicting lesion progression is largely unknow...BACKGROUND Intermediate coronary lesions(ICLs)are highly prevalent but ported mixed prognosis.Radial strain has been associated with plaque vulnerability,yet its role in predicting lesion progression is largely unknown.The purpose of this study was to determine the predictive value of angiography-derived radial wall strain(RWS)for progression of untreated non-culprit ICLs.METHODS Post-hoc analysis was conducted in a study cohort including 603 consecutive patients with 808 ICLs identified at index procedure with angiographic follow-up of up to two years.RWS analysis was performed on selected angiographic frames with minimal foreshortening and vessel overlap.Lesion progression was defined as≥20%increase in percent diameter stenosis.RESULTS Lesion progression occurred in 49 ICLs(6.1%)with a median follow-up period of 16.8 months.Maximal RWS(RWSmax),frequently located at the proximal and throat plaque regions,distinguished progressive ICLs from silent ones.The largest area under the curve value of 0.75(95%CI:0.67–0.82,P<0.001)was reached at the optimal RWSmax cutoff value of>12.6%.According to this threshold,178 ICLs were classified as having a high strain pattern.Exposure to a high strain amplitude with RWS_(max)>12.6%was independently associated with an increased risk of lesion progression(adjusted HR=6.82,95%CI:3.67–12.66,P<0.001).CONCLUSIONS Assessment of RWS from coronary angiography is feasible and provides independent prognostic value in patients with untreated ICLs.展开更多
Enhanced external counterpulsation(EECP)is able to treat myocardial ischemia,which is usually caused by coronary artery stenosis.However,the underlying mechanisms regarding why this technique is effective in treating ...Enhanced external counterpulsation(EECP)is able to treat myocardial ischemia,which is usually caused by coronary artery stenosis.However,the underlying mechanisms regarding why this technique is effective in treating myocardial ischemia remains unclear and there is no patient-specific counterpulsation mode for different rates of coronary artery stenosis in clinic.This study sought to investigate the hemodynamic effect of varied coronary artery stenosis rates when using EECP and the necessity of adopting targeted counterpulsation mode to consider different rates of coronary artery stenosis.Three 3-dimensional(3D)coronary models with different stenosis rates,including 55%(Model 1),65%(Model 2),and 75%(Model 3),were generated,then coupled with a 0-dimensional(0D)lumped parametric model of the blood circulatory system.EECP was applied to the 0D/3D coupled models to study the hemodynamic response of the coronary artery.Under the same counterpulsation mode,the ratio of diastolic blood pressure to systolic blood pressure of 3 models during counterpulsation was 1.4,and the cardiac output and coronary artery flow rate increased significantly.The low wall shear stress(WSS)and high oscillatory shear index(OSI)areas were mainly located at the posterior end of the stenosis and coronary artery bifurcation.Moreover,with an increase in the rate of coronary artery stenosis,the increased percentage of flow rate through the coronary artery stenosis and area-averaged WSS decreased.The geometric multiscale model in this study can be used to effectively simulate the hemodynamic characteristics of cardiovascular system following the application of EECP.Local precise hemodynamic effect of the coronary artery stenosis can be observed.It was found from the hemodynamic factors that the coronary artery with lower stenosis rate more likely led to better vascular endothelial remodeling.Thus,it is necessary to adopt patient-specific counterpulsation mode accounting for different condition of coronary artery stenosis.展开更多
The coronary arteries diseases are one of the most causes of mortality and morbidity worldwide, particularly in the developing countries. Coronary obstructions are generally described by location and severity of steno...The coronary arteries diseases are one of the most causes of mortality and morbidity worldwide, particularly in the developing countries. Coronary obstructions are generally described by location and severity of stenosis. Manual tracing and measurement of the stenosis vessel in comparison to reference location of stenosis can be helpful to classify whether a lesion is significant or not. The aim of this study is to identify the dominant type of circulation carried out in patients presented in heart institute and associated with degree of stenosis in RCA and LAD artery. Materials and Methods: This was a retrospective study carried out on patients reporting to Heart Institute from June 2013 to August 2013 (311 patients records as a total coverage were collected as sample) whose coronary artery angiography revealed pathology in coronary arteries. Result: The findings were 71.7% right dominant, 23.5% left dominant and 4.8% co-dominant;LAD tends to be stricture with right dominant circulation type. LAD artery tends to be stenosis at proximal and mid segment while in the RCA tends to be stenosis in mid and distal segments. The right dominant artery is popular type of circulation in Sudanese people reported in Sudan Heart Institute;there is no significance association between gender and arterial type of circulation and also degree stenosis in LAD degree of stenosis in RCA. I observed that the site of stenosis in LAD artery was proximal and mid (P value < 0.05 significance association). Conclusion: Patients present at the heart institute are right dominant mostly coming with proximal and middle LAD stenosis unlike RCA which commonly presents with distal and middle stenosis, so the middle segment of coronary artery is stenosis in both situations. There are wild variations in dominance artery in relation to reduction of diameter in deferent ethic group. There are no significant associations between the gender and dominant artery.展开更多
A single coronary artery is a very rare condition,commonly associated with other congenital anomalies.It could be generally considered as neither benign nor malignant form of congenital coronary artery anomalies since...A single coronary artery is a very rare condition,commonly associated with other congenital anomalies.It could be generally considered as neither benign nor malignant form of congenital coronary artery anomalies since its pathophysiological and clinical implications grossly depend on different anatomical patterns defined by the site of origin and distribution of the branches.By presenting the patient who underwent successful coronary artery bypass grafting and aortic valve replacement surgery in a presence of isolated single coronary artery,we intend to emphasize natural and procedural risks and distinguish casual from causal in this extremely rare clinical and surgical scenario.展开更多
Objective To compare coronary angiography(CAG) and optical coherence tomography(OCT) findings in stenosis and culprit lesion morphology assessment in coronary artery disease patients with moderate stenosis(50%~70%).M...Objective To compare coronary angiography(CAG) and optical coherence tomography(OCT) findings in stenosis and culprit lesion morphology assessment in coronary artery disease patients with moderate stenosis(50%~70%).Methods 23 CAD patients with moderate stenosis(50%~70%) were enrolled in the study.These patients then underwent OCT analysis.CAG and OCT stenosis results were compared for conformity.OCT images of the culprit lesions were analyzed for more details about the morphological characteristics of the plaques in relation with the clinical diagnosis.Results Evaluation of stenosis of coronary lesions by Quantitative Coronary Angiography(QCA) corresponds approximately with OCT analysis estimation:CAG stenosis was 57.26% ±5.05,whereas the same OCT stenosis analysis reached a value of 61.17%±11.36,(P=0.032).From OCT image analysis,the vulnerable plaque was detected more in the culprit lesions of patients with a clinical diagnosis of unstable angina,than in stable angina pectoris patients(61.5%vs10%;P=0.012).展开更多
Objective To observe the relationship between serum creatine kinase isoenzyme MM sub-bands (CKMM3/MM1 ratio) and the gradation of coronary stenosis and provide a simple, reliable, and economical method for identifying...Objective To observe the relationship between serum creatine kinase isoenzyme MM sub-bands (CKMM3/MM1 ratio) and the gradation of coronary stenosis and provide a simple, reliable, and economical method for identifying high-risk unstable angina pectoris (UAP). Mehtods Blood samples were drawn at different time after onset of chest pain in 21 patients with UAP and only once in 20 each volunteers for control. CKMM3/MM1 ratio was detected by nonserial buffer agarose gel electrophoresis. CKMB and CK were observed by velocity method. An emergent coronary arteriography was performed as soon as patients were admitted into hospital. Results Patients with UAP were divided into two subgroups: patients with elevated serum enzyme [P( + )] and patients with normal serum enzyme [P( - ) ] according to CKMM3/MM1 ratio < 0. 5. Patients with UAP( + ) had higher serum CKMM3/MM1 ratios from 0.5 to 12hrs and serum CKMB from 2 to 12 hrs than those with UAP( - ) and control ( P < 0. 05) . Serum enzyme concentrations of patients with UAP whose coronary lumen had 90% or more than 90% stenosis were significantly higher than those whose coronary lumen had less than 90% stenosis ( P <0. 01) . Any CK-MM3/MM1 ratio was less than 1. 0 and CK within the normal range in patients with UAP( + ) group. Conclusions CKMM3/MM1 ratios in patients with UAP can reflect severity of myocardial ischemia. SerumCKMM3/MM1 ratio provides a simple, reliable, and economical method for identifying high-risk UAP.展开更多
基金supported by the National Key Research and Development Program (No.2022YFC2407001)。
文摘OBJECTIVE To evalu ate the role of resting magnetocardiography in identifying seve re coronary artery stenosis in patients with suspected coronary artery disease.METHODS A total of 513 patients with angina symptoms were included and divided into two groups based on the extent of coronary artery disease determined by angiography:the non-severe coronary stenusis group(<70% stenosis) and the severe coronary stenosis group(≥70% stenosis).The diagnostic model was constructed using magnetic field map(MFM) parameters,either individually or in combination with clinical indicators.The performance of the models was evaluated using receiver operating characteristic curves,accuracy,sensitivity,specificity,positive predictive value(PPV) and ne gative predictive value(NPV).Calibration plots and decision curve analysis were performed to investigate the clinical utility and performance of the models,respectively.RESULTS In the severe coronary stenosis group,QR_MCTDd,S_MDp,and TT_(MA)C_(50) were significantly higher than those in the non-severe coronary stenosis group(10,46±10.66 vs,5.11±6.07,P <0.001;7.2±8.64 vs.4.68±6.95,P=0.003;0.32±57.29 vs.0.26±57.29,P <0.001).While,QR_MV_(amp),R_(MA),and T_(MA) in the severe coronary stenosis group were lower(0.23±0.16 vs.0.28±0.16,P<0.001;55.06±48.68 vs.59.24±53.01,P<0.001;51.67±39.32 vs. 60.45±51.33,P <0.001).Seven MFM parameters were integrated into the model,resulting in an area under the curve of 0.810(95% CI:0.765-0.855).The sensitivity,specificity,PPV,NPV,and accurecy were 71.7%,80.4%,93.3%,42.8 %,and 73.5%;respectevely.The combined model exhibited an area under the curve of 0.845(95% CI:0.798-0.892).The sensitivity,specificity,PPV,NPV,and accuracy were 84.3%,73.8%,92.6%,54.6%,and 82.1%;respectively.Calibration curves demonstrate d excellent agreement between the nomogram prediction and actual observation.The decision curve analysis showed that the c ombine d model provided greater net benefit compared to the magnetocardingraphy model.CONCLUSIONS The novel quantitative MFM parameters,whether used individually or in combination with clinical indicators,have been shown to effectively pre dict the risk of severe coronary stenosis in patients presenting with angina-like symptoms.Magnetocardiography,an emerging non-invasive diagnostic tool,warrants further exploration for its potential in diagnosing coronary heart disease.
文摘Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
文摘BACKGROUND Coronary artery stenosis(CAS)is the most common type of heart disease and the leading cause of death in both men and women globally.CAS occurs when the arteries that supply blood to the heart muscle harden and become narrower due to plaque buildup-cholesterol and other material-on their inner walls.As a result,the heart muscle cannot receive the blood or oxygen it needs.Most heart attacks happen when a blood clot suddenly cuts off the hearts'blood supply,causing permanent heart damage.AIM To analyze the relationship between the left ventricular ejection fraction(LVEF),left ventricular strain(LVS),and coronary stenosis.METHODS A total of 190 participants were enrolled in this trail.The control group comprised 93 healthy individuals,and observation group comprised 97 patients with coronary heart disease who were hospitalized between July 2020 and September 2021.Coronary lesions were assessed using the Gensini score,and the LVEF and LVS were measured using magnetic resonance imaging(MRI).The interaction between the LVEF and LVS was examined using a linear regression model.The relationship between LVEF and coronary stenosis was examined using Spearman’s correlation.RESULTS The LVEF of the observation group was lower than that of the control group.The left ventricular end-systolic volume(LVESV)and left ventricular end-diastolic volume(LVEDV)of the observation group were significantly higher than those of the control group(P<0.05).The longitudinal and circumferential strains(LS,CS)of the observation group were significantly higher than those of the control group;however,the radial strain(RS)of the observation group was significantly lower than that of the control group(P<0.05).LVS,LS,and CS were significantly negatively correlated with the LVEF,and RS was positively correlated with the LVEF.There were significant differences in the LVEF,LVESV,and LVEDV of patients with different Gensini scores;the LVEF significantly decreased and the LVESV and LVEDV increased with increasing Gensini scores(P<0.05).In the observation group,the LVEF was negatively correlated and the LVESV and LVEDV were positively correlated with coronary stenosis(P<0.05).CONCLUSION The LVEF measured using MRI is significantly linearly correlated with LVS and negatively correlated with coronary stenosis.
文摘Objective:To analyze the imaging effect and accuracy of 64-slice spiral CT in the diagnosis of coronary artery stenosis.Methods:30 patients with suspected coronary heart disease admitted to our hospital from March 2022 to March 2023 were selected.All patients underwent both 64-slice spiral CT and digital subtraction angiography(DSA).DSA is considered the gold standard for diagnosis,so it was used to analyze the diagnostic performance of 64-slice spiral CT.Results:(1)The diagnostic results of digital subtraction angiography and 64-slice spiral CT was analyzed and compared with each other.The 64-slice spiral CT had an accuracy of 96.67%(29/30),a sensitivity 96.55%(28/29),and a specificity of 100.00%(1/1)in diagnosing coronary artery stenosis.(2)There was no significant difference between 64-slice spiral CT and digital subtraction angiography in the positive detection rate of anterior descending artery lesion,the positive detection rate of left main lesion,the positive detection rate of left circumflex artery lesion and the positive detection rate of right coronary artery lesion(P>0.05).(3)There was no significant difference between 64-slice spiral CT examination and DSA examination in identifying mild stenosis,moderate stenosis,and severe stenosis of coronary arteries(P>0.05).Conclusion:64-slice spiral CT examination can accurately determine the degree of occlusion of coronary arteries,which allows for the accurate diagnosis of coronary artery stenosis.
基金supported by the National Institute of Health (NIH Grant HL-92954 and AG-31750 to A.L)supported by an unrestricted grant from St Jude Medical+1 种基金supported by the National Natural Science Foundation of China (No.81470491)the Beijing Municipal Natural Science Foundation (No. 7192078)
文摘Objective To explore the safety and efficacy of FFR-guided percutaneous coronary intervention (PCI) in vessels with severe diameter stenosis. Methods & Results Of 1090 patients undergoing fractional flow reserve (FFR) assessment from 2002 to 2009,we identified 167 patients in whom FFR was measured in at least one 70%–89% stenotic lesion. These patients were subdivided into an FFR-defer group (n = 49) if PCI was deferred (FFR > 0.80),and an FFR-perform group (n = 118) if PCI was performed (FFR ≤ 0.80). Comparatively,an additional 1176 patients undergoing PCI in at least one lesion with 70%–89% stenosis but without measurement of FFR served as a control (angiography- guided) group. Clinical outcomes were compared during a median follow-up of 49.0 months. The 5-year Kaplan-Meier estimated revascularization rates were 16% in the FFR-defer group and 33% in the FFR-perform group (P = 0.046). The incidence of major adverse cardiac events were comparable in these two groups (HR = 0.82,95% CI: 0.37–1.82,P = 0.63). The number of stents placed was significantly lower in the FFR-guided group (0.9 ± 0.8 vs. 1.4 ± 0.8,P < 0.001). Conclusions Functional revascularization for lesions with visually severe stenosis is clinically safe and associated with fewer stents use. This study suggests that extending the use of FFR to more severe coronary lesions may be reasonable.
基金supported by research grants from the Innovation and Cultivation Fund of the Sixth Medical Center of Chinese People’s Liberation Army General Hospital(grant number:CXPY201925).
文摘Aim:Intracoronary murmur results from turbulent flow due to coronary artery narrowing.This study evaluated the diagnostic performance of a method for acoustic analysis of turbulent murmur caused by coronary artery stenosis in coronary artery disease(CAD)in Chinese populations.Method:Patients admitted to the cardiovascular department of the Sixth Medical Center of the Chinese People’s Liberation Army General Hospital between September 2021 and June 2022 for elective coronary angiography were prospectively enrolled.A digital electronic stethoscope was used to record heart sounds before angiography.Quantitative coronary angiography(QCA)served as the“gold standard”for CAD diagnosis to evaluate the diagnostic performance of the acoustic analysis method for CAD.Results:A total of 452 patients had complete QCA and heart sound data.The final interpretation results of the acoustic analysis method indicated 310 disease cases and 142 normal results.Increasing the cut-off values of coronary artery diameter stenosis from 30%to 50%,70%,and 90%increased the sensitivity and NPV of the acoustic analysis method;the sensitivity was 75.6%,81.9%,83.3%,and 85.7%,respectively;the NPV was 33.1%,57.0%,69.7%,and 88.0%,respectively;the specificity and PPV decreased(specificity of 75.8%,70.4%,51.0%,and 37.5%,respectively;PPV of 95.2%,89.0%,69.4%,and 32.9%,respectively);and the AUC values were 0.757,0.762,0.672,and 0.616,respectively.The sensitivity of the acoustic analysis method for one-vessel disease was 86.6%when the cut-off value was 50%.The sensitivity for identifying left anterior descending coronary artery lesions was best,at 90.7%.The sensitivity for identifying isolated coronary artery branch lesions was 66.7%,whereas the sensitivity for identifying three-vessel disease in multi-vessel coronary artery lesions was better,at 82.9%.Conclusion:Acoustic analysis of turbulent murmur caused by coronary artery stenosis for diagnosis of CAD may have favorable performance in the Chinese population.This method has good performance in CAD diagnosis with a cut-off coronary artery diameter for stenosis of 50%.
文摘Background: The association of right coronary artery (RCA) stenosis in patients undergoing myocardial revascularization for left main coronary artery (LMCA) stenosis affects the prognosis. This study aimed to compare immediate results of patients with isolated LMCA stenosis and those with combined RCA stenosis. Patients and methods: We retrospectively evaluated 107 consecutive patients with LMCA disease who underwent coronary artery bypass grafts. The patients were divided into two groups: isolated LMCA stenosis (n = 36) and LMCA stenosis + RCA stenosis (n = 71). Different variables (preoperative, intra operative and post operative) were compared. Results: Patients with LMCA stenosis + RCA stenosis experienced higher prevalence of diabetes mellitus (p = 0.024) and smoker (p = 0.032). Also left ventricular EF was reduced (p = 0.004). Myocardial revascularization was more complete in patients with LMCA stenosis + RCA stenosis (p = 0.033), but in-hospital mortality rate was higher (12.6% vs 5.5%) in isolated LLMCA stenosis, but it did not reach statistical significance (p = 0.32). Except low output syndrome (LOS) that was frequent in presence of RCA stenosis (p = 0.026), no significant difference was found between groups for other complications. Conclusion: The presence of RCA stenosis in patients undergoing CABG for LMCA disease increases 30 day mortality but without significant impact on overall morbidities.
文摘Objective Biochemical indicators such as N-terminal pro-brain type natriuretic peptide(NT pro-BNP)and high-sensitivity Creactive protein(hsCRP)predict mortality in acute coronary syndrome(ACS).However,little is known about the relationship of these factors with severity of coronary artery stenosis in patients with.Methods Three hundred and thirty-one subjects including 246 unstable angina pectoris patients and 85 myocardial infarction patients were recruited and classified into two groups:single-vessel disease group(1-vessel disease,n=93)and multiple-vessel disease group(≥2-vessels disease,n=238)according to selective coronary angiography.Plasma levels of NT pro-BNP and hsCRP were measured and severity of coronary stenosis was determined by Gensini score.Results NT pro-BNP but not hsCRP level was higher in patients with myocardial infarction than in patients with unstable angina pectoris.The patients with multiple-vessel disease had significantly higher NT pro-BNP level but not hsCRP compared with those with single-vessel disease.NT pro-BNP levels increased significantly as left ventricle(LV)function decreased,and only NT proBNP but not hsCRP level was related to Gensini score of severity of coronary stenosis in ACS.Conclusion NT proBNP but not hsCRP level is related to severity of coronary artery stenosis in patients in ACS.
文摘Coronary angiography is considered to be the gold standard in the morphological evaluation of coronary artery stenosis. The morphological assessment of the severity of a coronary lesion is very subjective. Thus, the invasive fractional flow reserve(FFR) measurement represents the current standard for estimation of the hemodynamic significance of coronary artery stenosis. The FFR-guided revascularization strategy was initially classified as a Class-IA-recommendation in the 2014 European Society of Cardiology/European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. Both the Deferral vs Performance of Percutaneous Coronary Intervention of Functionally Non-Significant Coronary Stenosis and Flow Reserve vs Angiography for Multivessel Evaluation studies showed no treatment advantage for hemodynamically insignificant stenoses. With the help of FFR(and targeted interventions), clinical results could be improved; however, the use in clinical practice is still limited due to the need of adenosine administration and a significant prolongation of the length of the procedure. Instantaneous wave-free ratio(iFR~) is a new innovative approach for the determination of the hemodynamic significance of coronary stenosis, which can be obtained at rest without the use of vasodilators. Regarding the periprocedural complications as well as prognosis, iFR~ showed non-inferiority to FFR in the SWEDEHEART and DEFINE-FLAIR trials. Furthermore, iFR~, enhanced by iFR~-pullback, provides the possibility to display the iFR~-change over the course of the vessel to create a hemodynamic map.
文摘AIM To investigate the relationship between coronary calcium score(CCS) and vulnerable plaque/significant stenosis using coronary computed tomographic angiography(CCTA). METHODS CCTA was performed in 651 patients and these patients were divided into the four groups(CCS 0, 1-100, 101-400 and > 400). We studied the incidence of high-risk plaque, including positive remodeling, low attenuation plaque, spotty calcification, and napkin-ring sign, and significant stenosis in each group. RESULTS High-risk plaque was found in 1.3%, 10.1%, 13.3% and 13.4% of patients with CCS 0, 1-100, 101-400 and > 400, respectively(P < 0.001). The difference was only significant for patients with zero CCS. The incidence of significant stenosis was 0.6%, 7.6%, 13.3% and 26.9% for each patient group, respectively(P < 0.001), which represented a significant stepwise increase as CCS increased. The combined incidence of high-risk plaque and significant stenosis was 1.9%, 17.7%, 26.9% and 40.3% in each patient group, respectively(P < 0.001), again representing a significant stepwise increase with CCS. The rate of major coronary event was 0%, 4.0%, 7.9% and 17.2% in each patient group, respectively(P < 0.001), another significant stepwise increase as CCS increased. CONCLUSION Stepwise increased risk of coronary events associated with increasing CCS is caused by increasing incidence of significant stenosis, while that of high-risk plaque remains the same.
文摘The purpose of this paper is to study the changes of deformabilityof erythrocytes and 2.3-DPG(2.3-diphosphoglycerate acid)in the patients with coro-nary artery stenosis and the effects of some factors on them.It is showed that:de-formability of crythrocyte and 2.3-DPG were inversely proportional to the degreeof the lesions of coronary vessels(P【0.01);there was a significant decrease of de-formability of erythrocytes after using contract agents(P【0.01);Salvia increaseddeformability and 2.3-DPG significantly(P【0.01).In conclusion,our data suggestthat the possible existence of microcirculation dysfunction in coronary artery dis-eases with parallelism to the impairement deformability of erythrocytcs and Salviabca good drug to action in deformability and 2.3 DPG in patients.
文摘The role of 16-slice spiral CT was selective X-ray coronary angiography (SCA) who were suspected of having coronary heart evaluated in the diagnosis of coronary stenosis, with serving as the reference standard. Sixty-five patients disease, without percutaneous transluminal coronary angioplasty or coronary bypass-grafting, were investigated using 16-slice CT. Eight patients with pre-scan heart rate of more than 80 beats/min were given β-blockers. After the retrospectively ECG-gated axial imaging reconstruction, volume redering (VR), multi-planar reconstruction (MPR), curved MPR and maximum intensity projection (MIP) were used to reconstruct. Every segment of coronary artery with a diameter ≥1.5 mm was assessed, and the presence on CT with a stenosis exceeding 50 % diameter reduction was compared with that on SCA. The reasons which lead to some segments unevaluable were analysed. Compared with SCA, 93 % coronary segments and 94 % main branches were evaluable. Residual cardiac motion artifacts, severe calcification and poor opacification made 58 %, 28 % and 14 % of the remaining 60 segments unevaluable respectively. Without routine administration of β-blockers, good coronary imaging quality can be acquired using 16-slice spiral CT. It is a reliable noninvasive method for detection of obstructive coronary artery disease.
文摘Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery.
基金supported by the National Natural Science Foundation of China(No.82020108015&No.81871460&No.82170333)。
文摘BACKGROUND Intermediate coronary lesions(ICLs)are highly prevalent but ported mixed prognosis.Radial strain has been associated with plaque vulnerability,yet its role in predicting lesion progression is largely unknown.The purpose of this study was to determine the predictive value of angiography-derived radial wall strain(RWS)for progression of untreated non-culprit ICLs.METHODS Post-hoc analysis was conducted in a study cohort including 603 consecutive patients with 808 ICLs identified at index procedure with angiographic follow-up of up to two years.RWS analysis was performed on selected angiographic frames with minimal foreshortening and vessel overlap.Lesion progression was defined as≥20%increase in percent diameter stenosis.RESULTS Lesion progression occurred in 49 ICLs(6.1%)with a median follow-up period of 16.8 months.Maximal RWS(RWSmax),frequently located at the proximal and throat plaque regions,distinguished progressive ICLs from silent ones.The largest area under the curve value of 0.75(95%CI:0.67–0.82,P<0.001)was reached at the optimal RWSmax cutoff value of>12.6%.According to this threshold,178 ICLs were classified as having a high strain pattern.Exposure to a high strain amplitude with RWS_(max)>12.6%was independently associated with an increased risk of lesion progression(adjusted HR=6.82,95%CI:3.67–12.66,P<0.001).CONCLUSIONS Assessment of RWS from coronary angiography is feasible and provides independent prognostic value in patients with untreated ICLs.
基金This research was supported by National Natural Science Foundation of China(11772016,11472022,11702008)Key Project of Science and Technology of Beijing Municipal Education Commission and Support Plan for High-level Faculties in Beijing Municipal Universities(CIT&TCD201804011).
文摘Enhanced external counterpulsation(EECP)is able to treat myocardial ischemia,which is usually caused by coronary artery stenosis.However,the underlying mechanisms regarding why this technique is effective in treating myocardial ischemia remains unclear and there is no patient-specific counterpulsation mode for different rates of coronary artery stenosis in clinic.This study sought to investigate the hemodynamic effect of varied coronary artery stenosis rates when using EECP and the necessity of adopting targeted counterpulsation mode to consider different rates of coronary artery stenosis.Three 3-dimensional(3D)coronary models with different stenosis rates,including 55%(Model 1),65%(Model 2),and 75%(Model 3),were generated,then coupled with a 0-dimensional(0D)lumped parametric model of the blood circulatory system.EECP was applied to the 0D/3D coupled models to study the hemodynamic response of the coronary artery.Under the same counterpulsation mode,the ratio of diastolic blood pressure to systolic blood pressure of 3 models during counterpulsation was 1.4,and the cardiac output and coronary artery flow rate increased significantly.The low wall shear stress(WSS)and high oscillatory shear index(OSI)areas were mainly located at the posterior end of the stenosis and coronary artery bifurcation.Moreover,with an increase in the rate of coronary artery stenosis,the increased percentage of flow rate through the coronary artery stenosis and area-averaged WSS decreased.The geometric multiscale model in this study can be used to effectively simulate the hemodynamic characteristics of cardiovascular system following the application of EECP.Local precise hemodynamic effect of the coronary artery stenosis can be observed.It was found from the hemodynamic factors that the coronary artery with lower stenosis rate more likely led to better vascular endothelial remodeling.Thus,it is necessary to adopt patient-specific counterpulsation mode accounting for different condition of coronary artery stenosis.
文摘The coronary arteries diseases are one of the most causes of mortality and morbidity worldwide, particularly in the developing countries. Coronary obstructions are generally described by location and severity of stenosis. Manual tracing and measurement of the stenosis vessel in comparison to reference location of stenosis can be helpful to classify whether a lesion is significant or not. The aim of this study is to identify the dominant type of circulation carried out in patients presented in heart institute and associated with degree of stenosis in RCA and LAD artery. Materials and Methods: This was a retrospective study carried out on patients reporting to Heart Institute from June 2013 to August 2013 (311 patients records as a total coverage were collected as sample) whose coronary artery angiography revealed pathology in coronary arteries. Result: The findings were 71.7% right dominant, 23.5% left dominant and 4.8% co-dominant;LAD tends to be stricture with right dominant circulation type. LAD artery tends to be stenosis at proximal and mid segment while in the RCA tends to be stenosis in mid and distal segments. The right dominant artery is popular type of circulation in Sudanese people reported in Sudan Heart Institute;there is no significance association between gender and arterial type of circulation and also degree stenosis in LAD degree of stenosis in RCA. I observed that the site of stenosis in LAD artery was proximal and mid (P value < 0.05 significance association). Conclusion: Patients present at the heart institute are right dominant mostly coming with proximal and middle LAD stenosis unlike RCA which commonly presents with distal and middle stenosis, so the middle segment of coronary artery is stenosis in both situations. There are wild variations in dominance artery in relation to reduction of diameter in deferent ethic group. There are no significant associations between the gender and dominant artery.
文摘A single coronary artery is a very rare condition,commonly associated with other congenital anomalies.It could be generally considered as neither benign nor malignant form of congenital coronary artery anomalies since its pathophysiological and clinical implications grossly depend on different anatomical patterns defined by the site of origin and distribution of the branches.By presenting the patient who underwent successful coronary artery bypass grafting and aortic valve replacement surgery in a presence of isolated single coronary artery,we intend to emphasize natural and procedural risks and distinguish casual from causal in this extremely rare clinical and surgical scenario.
文摘Objective To compare coronary angiography(CAG) and optical coherence tomography(OCT) findings in stenosis and culprit lesion morphology assessment in coronary artery disease patients with moderate stenosis(50%~70%).Methods 23 CAD patients with moderate stenosis(50%~70%) were enrolled in the study.These patients then underwent OCT analysis.CAG and OCT stenosis results were compared for conformity.OCT images of the culprit lesions were analyzed for more details about the morphological characteristics of the plaques in relation with the clinical diagnosis.Results Evaluation of stenosis of coronary lesions by Quantitative Coronary Angiography(QCA) corresponds approximately with OCT analysis estimation:CAG stenosis was 57.26% ±5.05,whereas the same OCT stenosis analysis reached a value of 61.17%±11.36,(P=0.032).From OCT image analysis,the vulnerable plaque was detected more in the culprit lesions of patients with a clinical diagnosis of unstable angina,than in stable angina pectoris patients(61.5%vs10%;P=0.012).
文摘Objective To observe the relationship between serum creatine kinase isoenzyme MM sub-bands (CKMM3/MM1 ratio) and the gradation of coronary stenosis and provide a simple, reliable, and economical method for identifying high-risk unstable angina pectoris (UAP). Mehtods Blood samples were drawn at different time after onset of chest pain in 21 patients with UAP and only once in 20 each volunteers for control. CKMM3/MM1 ratio was detected by nonserial buffer agarose gel electrophoresis. CKMB and CK were observed by velocity method. An emergent coronary arteriography was performed as soon as patients were admitted into hospital. Results Patients with UAP were divided into two subgroups: patients with elevated serum enzyme [P( + )] and patients with normal serum enzyme [P( - ) ] according to CKMM3/MM1 ratio < 0. 5. Patients with UAP( + ) had higher serum CKMM3/MM1 ratios from 0.5 to 12hrs and serum CKMB from 2 to 12 hrs than those with UAP( - ) and control ( P < 0. 05) . Serum enzyme concentrations of patients with UAP whose coronary lumen had 90% or more than 90% stenosis were significantly higher than those whose coronary lumen had less than 90% stenosis ( P <0. 01) . Any CK-MM3/MM1 ratio was less than 1. 0 and CK within the normal range in patients with UAP( + ) group. Conclusions CKMM3/MM1 ratios in patients with UAP can reflect severity of myocardial ischemia. SerumCKMM3/MM1 ratio provides a simple, reliable, and economical method for identifying high-risk UAP.