期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Comparison of the treatment duration and nursing requirements of the EarWell infant ear correction system for different types of auricle deformities
1
作者 Wei Wei Chang-Zhi Sun +4 位作者 Xiao-Ya Wang Jie Zhong Qian-Jun Liao Yan-Ying Cai Rui Mi 《Frontiers of Nursing》 2023年第3期357-362,共6页
Objective:To observe whether the Ear Well infant ear correction system makes any difference in terms of the treatment effect,duration,complication rate,and nursing care requirements in different types of infant auricl... Objective:To observe whether the Ear Well infant ear correction system makes any difference in terms of the treatment effect,duration,complication rate,and nursing care requirements in different types of infant auricle deformities.Methods:A total of 93 infant patients with auricular deformity(age:<3 months of age)who were diagnosed and treated in Guangzhou Children and Women’s Medical Center from April 2018 to September 2020 were selected and treated with the Ear Well infant ear correction system.We observed and recorded the effects of the Ear Well infant ear correction system,the treatment duration,the number of rebound cases,and complications that are likely to occur during treatment,and noted the related factors causing complications and the relative requirements for nursing care.Results:The Earwell infant ear correction system could effectively correct infant auricle deformities.Among the 93 cases,90 cases had positive therapeutical outcome and the effective rate was 96.77%.The treatment duration for lop ear and protruding ear was longer than for other auricle deformities;the deformity recoil and the treatment compilation rates were much higher for these 2 deformity types,and the difference was statistically significant(P<0.05).Conclusions:The treatment suggestion for the wearing duration of the Ear Well infant ear correction system for lop ear and protruding ear is a prolonged duration compared with that for other infant auricle deformities.Fur ther,the requirements for nursing care intensity and infant patient’s guardian’s nursing knowledge and skill are obviously increased for these 2 types of auricle deformities. 展开更多
关键词 complication rate correction effect EarWell infant ear correction system infant auricle deformities nursing care and patient guardian education treatment duration
下载PDF
Edge Effect Correction in the S-A Method for Geochemical Anomaly Separation 被引量:30
2
作者 Ge Yong Department of Earth and Atmospheric Science, York University, Toronto, ON, M3J 1P3, Canada State Key Laboratory of Resources and Environmental Information System, Institute of Geographic Sciences & Natural Resources Research, Chinese Academy of Sciences, Beijing 100101, China Cheng Qiuming Department of Earth and Atmospheric Science, York University, Toronto, ON, M3J 1P3, Canada +1 位作者 Earth Systems and Mineral Resource Engineering Lab, China University of Geosciences, Wuhan 430074, China Zhang Shenyuan Department of Earth and Atmospheric Science, York University, Toronto, ON, M3J 1P3, Canada Department of Resource and Earth Science, China University of Mining & Technology, Beijing 100083, China 《Journal of China University of Geosciences》 SCIE CSCD 2004年第4期379-387,共9页
Anomaly separation using geochemical data often involves operations in the frequency domain, such as filtering and reducing noise/signal ratios. Unfortunately, the abrupt edge truncation of an image along edges and ho... Anomaly separation using geochemical data often involves operations in the frequency domain, such as filtering and reducing noise/signal ratios. Unfortunately, the abrupt edge truncation of an image along edges and holes (with missing data) often causes frequency distribution distortion in the frequency domain. For example, bright strips are commonly seen in frequency distribution when using a Fourier transform. Such edge effect distortion may affect information extraction results; sometimes severely, depending on the edge abruptness of the image. Traditionally, edge effects are reduced by smoothing the image boundary prior to applying a Fourier transform. Zero-padding is one of the most commonly used smoothing methods. This simple method can reduce the edge effect to some degree but still distorts the image in some cases. Moreover, due to the complexity of geoscience images, which can include irregular shapes and holes with missing data, zero-padding does not always give satisfactory results. This paper proposes the use of decay functions to handle edge effects when extracting information from geoscience images. As an application, this method has been used in a newly developed multifractal method (S-A) for separating geochemical anomalies from background patterns. A geochemical dataset chosen from a mineral district in Nova Scotia, Canada was used to validate the method. 展开更多
关键词 edge effect correction fractal modeling spatial information extraction zero-padding decay functions.
下载PDF
Types and Correction Methods of Matrix Effect during Zircon LA-ICP-MS U-Pb Dating 被引量:1
3
作者 WANG Jiasong PENG Lina +2 位作者 XU Yawen ZHANG Nan LI Guozhan 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2015年第6期2099-2100,共2页
Matrix effect primarily impacts the accuracy and precision of zircon LA-ICP-MS U-Pb data.This paper describes three types of matrix effect in zircon LA-ICPMS U-Pb dating,i.e.,the element matrix effect,high Ddpa or ura... Matrix effect primarily impacts the accuracy and precision of zircon LA-ICP-MS U-Pb data.This paper describes three types of matrix effect in zircon LA-ICPMS U-Pb dating,i.e.,the element matrix effect,high Ddpa or uranium matrix effect and alpha dose matrix effect,and illustrates the correction of these three effects.In addition,we point out the limitation and possible problems of the existing correction methods. 展开更多
关键词 PB Types and correction Methods of Matrix effect during Zircon LA-ICP-MS U-Pb Dating ICP MS
下载PDF
Effects of Gravitational Correction on Neutrino Emission from Neutron Stars
4
作者 丁文波 鄂姗姗 +2 位作者 喻孜 张齐 戚湛强 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第5期178-182,共5页
Considering the gravitational correction through introduction of weakly interacting light vector U bosons, not only the equation of state (EoS) of the neutron star matter, but also the cooling properties of neutron ... Considering the gravitational correction through introduction of weakly interacting light vector U bosons, not only the equation of state (EoS) of the neutron star matter, but also the cooling properties of neutron stars may be changed. In this work, effects of gravitational correction on neutrino emission and cooling of neutron stars in the matter with neutrons, protons, electrons, muons, △- and △0 are studied by the relativistic mean field theory and the related cooling theory. The results show that the effects are sensitive to the ratio of coupling strength to mass squared of U bosons, defined as gu. With increasing gu, the radial region where direct Urca process of nucleons can be allowed in a neutron star with the fixed mass becomes narrower, while the neutrino emissivity is somewhat higher. Moreover, the gravitational correction suppresses the effects of △- on neutrino emission. The gravitational correction leads the star to cool faster, and the higher the gu is, the faster the star cools. 展开更多
关键词 effects of Gravitational correction on Neutrino Emission from Neutron Stars
下载PDF
Plastic scintillation detectors for precision Time-of-Flight measurements of relativistic heavy ions 被引量:2
5
作者 林文健 赵建伟 +22 位作者 孙保华 何鎏春 林炜平 刘传业 谷畑勇夫 寺嶋知 田怡 王枫 王萌 张广鑫 章学恒 竺礼华 段利敏 胡荣江 刘忠 鲁辰桂 任培培 盛丽娜 孙志宇 王世陶 王涛峰 徐治国 郑勇 《Chinese Physics C》 SCIE CAS CSCD 2017年第6期128-133,共6页
Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of di... Plastic scintillation detectors for Time-of-Flight(TOF) measurements are almost essential for event-byevent identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of dimensions50×50×3^t mm^3and 80×100×3^t mm^3have been set up at the External Target Facility(ETF), Institute of Modern Physics(IMP). Their time, energy and position responses are measured with the^(18)O primary beam at 400 Me V/nucleon. After off-line corrections for walk effect and position, the time resolutions of the two detectors are determined to be 27 ps(σ) and 36 ps(σ), respectively. Both detectors have nearly the same energy resolution of3.1%(σ) and position resolution of about 3.4 mm(σ). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading the RIBLL2 beam line at IMP as well as for the high energy branch at HIAF. 展开更多
关键词 plastic scintillator TIME-OF-FLIGHT time resolution walk effect correction
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部