Summary: Preoperative planning of corrective osteotomy with traditional radiography has limitations in regards to determining the ideal osteotomy location and orientation in three-dimensional femoral de- formities. T...Summary: Preoperative planning of corrective osteotomy with traditional radiography has limitations in regards to determining the ideal osteotomy location and orientation in three-dimensional femoral de- formities. Though a successful operation can be planned preoperatively, intraoperative contingencies might adhere to the procedural plan in the performance of operation. To efficiently perform a planned procedure, proposed is a design to implement three-dimensional reconstruction photography, based on computer-tomography (CT) scan. A custom-made guide was designed to navigate the osteotomy as planned, and additionally, a personalized intramedullary nail was used for fixation after osteotomy. Three-dimensional (3D) photography of deformed femur was established based on the CT dataset and transferred into 3D photography processing software for further planning. Osteotomy planes were de- signed and adjusted at deformity sites to correct the 3D deformities. The methodology of a custom-made osteotomy guide was introduced in femoral corrective osteotomy, for the first time, to navigate the op- eration as planned. After the virtual osteotomy and reduction of bone segments, the parameters of a custom-made intramedullary nail were measured for manufacturing. Findings Virtual operation in computer shows complete correction of the 3D deformity. The osteotomy guide, obtained by rapid-prototyping techniques, navigates mimicking surgery on rapid-prototyping model of the involved femur as planned. Internal fixation was achieved using the custom-made intramedullary nail. Interpreta- tion three-dimensional visualization introduces an advantage in preoperative planning for corrective os- teotomy of 3D femoral deformity, and the custom-made osteotomy guide is crucial to realize such a de- liberate plan during the actual procedures. The internal fixator, such as an intramedullary nail, can be modified or personalized for fixation in unique cases.展开更多
BACKGROUND Humeral shaft fractures are relatively common in adults.Rotational malalignment is reported as one complication but severe rotational deformity of the humerus is extremely rare.To our knowledge,only three c...BACKGROUND Humeral shaft fractures are relatively common in adults.Rotational malalignment is reported as one complication but severe rotational deformity of the humerus is extremely rare.To our knowledge,only three cases of symptomatic humeral malrotation have been reported.There are sparse literature reports of humeral reconstruction correction.CASE SUMMARY We present a case of extreme rotational deformity of the humerus(180°)after humeral shaft fracture.The patient complained of pain and difficulties with activities of daily living.In addition,she found the deformity cosmetically unacceptable.Therefore,she was searching for surgical correction.Neurolysis of the radial nerve followed by derotational osteotomy of the humerus and internal fixation were performed.Postoperatively,the patient demonstrated transient iatrogenic radial nerve palsy which recovered completely during postoperative follow-up.The Disabilities of the Arm,Shoulder,and Hand score improved from 55 preoperatively to 16 at the final 2-year follow-up.CONCLUSION Single-stage radial neurolysis,derotational osteotomy and stable fixation is a feasible option to improve anatomic and functional problems of severely malrotated humeral shaft fractures.展开更多
基金supported by grants from the National Natural Science Foundation of China (No. 81141022)the General Hospital of Chinese Liberation Army (No. 10KMM09)
文摘Summary: Preoperative planning of corrective osteotomy with traditional radiography has limitations in regards to determining the ideal osteotomy location and orientation in three-dimensional femoral de- formities. Though a successful operation can be planned preoperatively, intraoperative contingencies might adhere to the procedural plan in the performance of operation. To efficiently perform a planned procedure, proposed is a design to implement three-dimensional reconstruction photography, based on computer-tomography (CT) scan. A custom-made guide was designed to navigate the osteotomy as planned, and additionally, a personalized intramedullary nail was used for fixation after osteotomy. Three-dimensional (3D) photography of deformed femur was established based on the CT dataset and transferred into 3D photography processing software for further planning. Osteotomy planes were de- signed and adjusted at deformity sites to correct the 3D deformities. The methodology of a custom-made osteotomy guide was introduced in femoral corrective osteotomy, for the first time, to navigate the op- eration as planned. After the virtual osteotomy and reduction of bone segments, the parameters of a custom-made intramedullary nail were measured for manufacturing. Findings Virtual operation in computer shows complete correction of the 3D deformity. The osteotomy guide, obtained by rapid-prototyping techniques, navigates mimicking surgery on rapid-prototyping model of the involved femur as planned. Internal fixation was achieved using the custom-made intramedullary nail. Interpreta- tion three-dimensional visualization introduces an advantage in preoperative planning for corrective os- teotomy of 3D femoral deformity, and the custom-made osteotomy guide is crucial to realize such a de- liberate plan during the actual procedures. The internal fixator, such as an intramedullary nail, can be modified or personalized for fixation in unique cases.
文摘BACKGROUND Humeral shaft fractures are relatively common in adults.Rotational malalignment is reported as one complication but severe rotational deformity of the humerus is extremely rare.To our knowledge,only three cases of symptomatic humeral malrotation have been reported.There are sparse literature reports of humeral reconstruction correction.CASE SUMMARY We present a case of extreme rotational deformity of the humerus(180°)after humeral shaft fracture.The patient complained of pain and difficulties with activities of daily living.In addition,she found the deformity cosmetically unacceptable.Therefore,she was searching for surgical correction.Neurolysis of the radial nerve followed by derotational osteotomy of the humerus and internal fixation were performed.Postoperatively,the patient demonstrated transient iatrogenic radial nerve palsy which recovered completely during postoperative follow-up.The Disabilities of the Arm,Shoulder,and Hand score improved from 55 preoperatively to 16 at the final 2-year follow-up.CONCLUSION Single-stage radial neurolysis,derotational osteotomy and stable fixation is a feasible option to improve anatomic and functional problems of severely malrotated humeral shaft fractures.