期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Determination the content of gypsum fibrosum in Xiaokening tablets by powder X ray diffraction method 被引量:2
1
作者 Jianping Zhang Xinxin Feng Dong Wang 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2019年第3期186-194,共9页
The research on the application of X-ray diffraction in the quantitative analysis of Chinese medicines is rare. The main reason is that the technical problems related to the internal standard and the selection of quan... The research on the application of X-ray diffraction in the quantitative analysis of Chinese medicines is rare. The main reason is that the technical problems related to the internal standard and the selection of quantitative peaks are not well solved, and the accuracy and precision of the results are not satisfactory. This study employed the concept of mass absorption coefficient based on the internal standard method, and the full spectrum fitting and quantitative methods were used to solve the above technical problems. The sample was blended. the internal standard substance of zinc oxide was fully ground, and tablets were prepared by positive pressure method. Under certain instrumental conditions, the PXRD pattern was obtained by scanning. The percentage of gypsum fibrosum in Xiaokening tablet was obtained by quantitative analysis of full spectrum fitting internal standard by TOPAS software. The method was investigated by methodology. At the same time, the method was compared by ion chromatography, and SPSS software was used to make a significant t test on the results of the two methods. After the investigation, the average standard recovery rate of CaSO4-2H2O was 99.06%(RSD = 3.02%);and the recovery rate for simulated samples was 96.7%. The method had good specificity. After statistical analysis, there was no significant difference between the new PXRD method and the traditional method of ion chromatography. 展开更多
关键词 Powder X ray diffraction Full spectrum fitting internal standard quantitative method Xiaokening tablet Gypsum fibrosum
原文传递
On the Error Characteristics in Analyzing theRadiated Fields from Gaussian DistributedAperture by the Complex Ray Method
2
作者 DuHuiping RuanYingzheng 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 1995年第2期24-27,共4页
The radiated fields from Gaussian Distributed Aperture (GDA) can be approaximately analyzed bythe Complex Ray Method (CRM). In this article, the radiated fields derived in terms of plana wave spectrumintegral are us... The radiated fields from Gaussian Distributed Aperture (GDA) can be approaximately analyzed bythe Complex Ray Method (CRM). In this article, the radiated fields derived in terms of plana wave spectrumintegral are used as standard, and the error source of the replacement by complex ray fields is found. Withdiscussions on the error characteristics of this CIUN approximation, conclusions are drawn which are expected to be helpful in applications of CRM. 展开更多
关键词 complex ray method (CRM) plane-wave spectrum integral Gaussian beam
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部