Structure of main air discharging switch and a crowbar TVS (triggered vacuum switch) are designed and their triggering characteristics are investigated. The experimental results showed that for TVS the operating vol...Structure of main air discharging switch and a crowbar TVS (triggered vacuum switch) are designed and their triggering characteristics are investigated. The experimental results showed that for TVS the operating voltage range is from 1.3 kV to 120 kV, its maximum delay time is 400 ns and its jitter is 4-10 ns. Based on these results the crowbar 10/350μs (i.e., with a front time of 10μs and a duration of 350 μs) pulse current circuit and its controlling circuit are designed. With a 10μF stored capacitor C and a 6 μF waveform forming induction, a pulse current is generated with a maximum of 100 kA, front time of 10 ns and duration of 350μs. This pulse waveform can be used for testing SPD (surge protective devices).展开更多
A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main dischar...A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main discharging switch, and a crowbar pseudospark switch. The active trigger technology was studied in the crowbar impulse current circuit. The circuit monitors the main discharging current and generates a trigger signal at a proper time for the crowbar pseudospark switch operation. The trigger characteristics of the main discharge switch and the crowbar pseu- dospark switch were investigated. By monitoring the preset applied capacitor voltage, the gap distance of the main discharging switch could be adjusted to ensure a discharging delay time less than 2 μs. Equipped with a surface ttashover trigger device made of high relative perimittivity dielectric material BaTiO3 (εr = 3460), the discharge delay time of the crowbar pseudospark switch is less than 85 ns, and the minimum operating voltage is less than 1% of its self-breakdown voltage. With a storage capacitor of 9 μF , an inductor of 18 μH and a crowbar pseudospark switch, a load of 30 mΩ and an applied capacitor voltage of 40 kV, an impulse current waveform of maximum 25 kA was generated with a rise time and time to half peak value of 17.2 μs and 336μs respectively.展开更多
'并网难'已成为风电发展的瓶颈,而低电压穿越(Low Voltage Ride Through,LVRT)是风电并网中的核心技术,目前主要采用Crowbar保护电路实现风电机组在大干扰下也具有LVRT能力,而Crowbar电路退出时间对电网故障恢复有很大的影响。...'并网难'已成为风电发展的瓶颈,而低电压穿越(Low Voltage Ride Through,LVRT)是风电并网中的核心技术,目前主要采用Crowbar保护电路实现风电机组在大干扰下也具有LVRT能力,而Crowbar电路退出时间对电网故障恢复有很大的影响。根据我国风电大规模远距离的特点,在DIgSILENT中建立了双馈风力发电机组(Doubly-Fed Induction Generator,DFIG)的动态模型,并经过远距离输电线与IEEE9节点电力系统相连,仿真分析了DFIG在各种短路故障条件下的运行特性,提出一种基于无功功率判定的Crowbar退出控制方法,能实现Crowbar电路在故障切除后立刻退出,提高了DFIG的LVRT能力。展开更多
基金supported by the New Century Talent Foundation of Ministry of Education of China (NCET-08-0438)
文摘Structure of main air discharging switch and a crowbar TVS (triggered vacuum switch) are designed and their triggering characteristics are investigated. The experimental results showed that for TVS the operating voltage range is from 1.3 kV to 120 kV, its maximum delay time is 400 ns and its jitter is 4-10 ns. Based on these results the crowbar 10/350μs (i.e., with a front time of 10μs and a duration of 350 μs) pulse current circuit and its controlling circuit are designed. With a 10μF stored capacitor C and a 6 μF waveform forming induction, a pulse current is generated with a maximum of 100 kA, front time of 10 ns and duration of 350μs. This pulse waveform can be used for testing SPD (surge protective devices).
文摘A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main discharging switch, and a crowbar pseudospark switch. The active trigger technology was studied in the crowbar impulse current circuit. The circuit monitors the main discharging current and generates a trigger signal at a proper time for the crowbar pseudospark switch operation. The trigger characteristics of the main discharge switch and the crowbar pseu- dospark switch were investigated. By monitoring the preset applied capacitor voltage, the gap distance of the main discharging switch could be adjusted to ensure a discharging delay time less than 2 μs. Equipped with a surface ttashover trigger device made of high relative perimittivity dielectric material BaTiO3 (εr = 3460), the discharge delay time of the crowbar pseudospark switch is less than 85 ns, and the minimum operating voltage is less than 1% of its self-breakdown voltage. With a storage capacitor of 9 μF , an inductor of 18 μH and a crowbar pseudospark switch, a load of 30 mΩ and an applied capacitor voltage of 40 kV, an impulse current waveform of maximum 25 kA was generated with a rise time and time to half peak value of 17.2 μs and 336μs respectively.