Design and calibration of an elliptical crystal spectrometer for the diagnosis of proton-induced x-ray emission(PIXE)
1
作者 方言律 李东彧 +9 位作者 程浩 高原 申泽清 杨童 李昱泽 夏亚东 晏炀 颜莎 林晨 颜学庆 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期220-225,共6页
Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spur... Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9. 展开更多
关键词 elliptical crystal spectrometer proton-induced x-ray emission applications of laser ion accelera-tion
下载PDF
Test of a High Throughput Detector on the X-ray Crystal Spectrometer of the EAST 被引量:1
2
作者 吕波 石跃江 +9 位作者 王福地 万宝年 Manfred BITTER Kenneth W. HILL Sang-gon LEE 李颖颖 符佳 张继宗 徐经翠 沈永才 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期97-100,共4页
An attempt was made to improve the spatio-temporal resolution of the tangen- tial X-ray crystal spectrometer (XCS) on the Experimental Advanced Superconducting Tokamak (EAST) by evaluating experimentally the appli... An attempt was made to improve the spatio-temporal resolution of the tangen- tial X-ray crystal spectrometer (XCS) on the Experimental Advanced Superconducting Tokamak (EAST) by evaluating experimentally the applicability of a novel X-ray photon detection tech- nology for measuring the satellite spectra of Ar XVII with a high counting rate. High-resolution experimental data on the profiles of ion temperature and plasma rotation velocity facilitate the studies of the mechanisms underlining important physical phenomena, such as plasma heating, L-H transition and momentum transport. Based on silicon diode array and single-photon counting technology, a relatively small area (83.8 x 33.5 mm~) two-dimensional detector was successfully in- stalled and tested in the recent EAST campaign. X-ray photon counting rate higher than 20 MHz was observed for the first time, and high quality satellite spectra were recorded for ion temperature and plasma rotation measurement, indicating that the new technology is suitable for the next-step high-resolution XCS on EAST, and the deployment of a detector array with a much larger X-ray sensing area is planned for better plasma coverage. 展开更多
关键词 X-ray crystal spectrometer high resolution ion temperature plasma rotation
下载PDF
A High-Efficiency X-Ray Crystal Spectrometer for X-Ray Thomson Scattering
3
作者 张小丁 张继彦 +4 位作者 杨国洪 韦敏习 胡广月 赵斌 郑坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第8期755-759,共5页
Highly oriented pyrolitic graphite (HOPG) has high X-ray diffraction efficiency due to its unique mosaic crystal structure, and thus is very suitable for its application to X-ray Thomson scattering measurement of so... Highly oriented pyrolitic graphite (HOPG) has high X-ray diffraction efficiency due to its unique mosaic crystal structure, and thus is very suitable for its application to X-ray Thomson scattering measurement of solid-density plasmas. In this article, by using the K-shell X-ray source from laser-produced Ti plasma, the properties of the HOPG spectrometer are characterized and compared with those of the flat Pentaerythritol (PET) spectrometer. The results show that the diffraction efficiency of the HOPG spectrometer under focusing condition is an order higher than that of the PET spectrometer, while the spectral resolution of the HOPG is about 320, high enough to be used in the measurement of X-ray Thomson scattering spectra. 展开更多
关键词 crystal spectrometer highly oriented pyrolytic graphite X-ray Thomson scattering
下载PDF
A New Method for Measurements of the Poloidal Rotation Velocities and Wavelength Calibration of X-ray Imaging Crystal Spectrometer in Magnetic Fusion Devices
4
作者 石跃江 吕波 +3 位作者 王福地 M.BITTER K.W.HILL 叶民友 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第4期265-267,共3页
A new simple method is presented for the wavelength calibration and measurement of poloidal rotation velocities with X-ray imaging crystal spectrometer(XICS)in magnetic fusion devices.In this method,the toroidal rot... A new simple method is presented for the wavelength calibration and measurement of poloidal rotation velocities with X-ray imaging crystal spectrometer(XICS)in magnetic fusion devices.In this method,the toroidal rotation of plasma is applied for high precise alignment and wavelength calibration of the poloidal XICS.The measurement threshold of poloidal rotation velocity can be lowered to 1-3 km/s with this method. 展开更多
关键词 X-ray imaging crystal spectrometer wavelength calibration poloidal rotation velocity
下载PDF
High efficiency X-ray diffraction diagnostic spectrometer with multi-curvature bent crystal 被引量:3
5
作者 Jun Shi Tong Yao +4 位作者 Miao Li Guohong Yang Minxi Wei Wanli Shang Feng Wang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2020年第11期77-81,共5页
In spectral diagnostic physics experiments of inertial confinement fusion, the spectral signal is weak due to the low diffraction efficiency when using bent crystals. A spectral diagnostic instrument with high efficie... In spectral diagnostic physics experiments of inertial confinement fusion, the spectral signal is weak due to the low diffraction efficiency when using bent crystals. A spectral diagnostic instrument with high efficiency and wide spectral range is urgently needed. A multi-curvature bent crystal with multi-energy focusing ability is proposed based on the traditional conical crystal geometry. It has advantages of wide spectral range, strong focusing ability, and high spectral resolution. It also can eliminate the imaging aberration in principle due to rotational symmetry for the incoming X rays. A spectral diagnostic experiment based on a fabricated multi-curvatureα-quartz crystal was accomplished using a titanium X-ray tube of the bent crystal, and the corresponding experimental data using a plane α-quartz crystal was also acquired to demonstrate the strong focusing ability.The result shows that the Kα intensity of the multi-curvature α-quartz crystal is 157 times greater than that of the plane crystal, and the corresponding energy range is about 4.51–5.14 keV. This diagnostic instrument could be combined with a streak camera at a vertical direction so as to intensify the diffracted X-ray signal with a wide spectral range. 展开更多
关键词 inertial confinement fusion X-ray crystal spectrometer multi-curvature bent crystal X-ray diffraction
原文传递
Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility 被引量:2
6
作者 李沫 吴坚 +4 位作者 王亮平 吴刚 韩娟娟 郭宁 邱孟通 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第12期322-326,共5页
Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are emp... Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility. 展开更多
关键词 electron temperature CONTINUUM curved crystal spectrometer Z-PINCH
下载PDF
Spatially-resolved spectroscopic diagnosing of aluminum wire array Z-pinch plasmas on QiangGuang-I facility 被引量:1
7
作者 叶凡 李正宏 +5 位作者 秦义 蒋树庆 薛飞彪 杨建伦 徐荣昆 金永杰 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期377-381,共5页
Spatially-resolved crystal spectrometers with a high spectral resolution are developed to diagnose K-shell x-ray radiation from Z-pinch plasmas. These diagnostic apparatuses are successfully applied to aluminum wire a... Spatially-resolved crystal spectrometers with a high spectral resolution are developed to diagnose K-shell x-ray radiation from Z-pinch plasmas. These diagnostic apparatuses are successfully applied to aluminum wire array Z-pinch experiments on QiangGuang-I facility, a driver with a pulsed current up to about 1.5 MA in 80 ns. Time-integrated experimental results show that the K-shell x-ray emission lines of aluminum Z-pinch plasmas are dominated by line emissions from helium-like ionisation state. Bright spots that might have higher electron temperature or density are produced randomly in location and size along the z-axis during implosions. According to the experimental data, the electron temperature and the ion density are estimated to be between 250 eV and 310 eV, and between 7.0× 10^19 cm-3 and 4.0 ×10^19 cm-3 respectively, while the ion temperature is inferred to be about 10.2 keV, which is much higher than the electron temperature. 展开更多
关键词 Z-PINCH wire array x-ray spectroscopy spatially-resolved crystal spectrometer
下载PDF
Observation and characterization of the effect of electron cyclotron waves on toroidal rotation in EAST L-mode discharges 被引量:2
8
作者 Jun CHEN Ruiji HU +17 位作者 Bo LYU Fudi WANG Xiaojie WANG Handong XU Yingying LI Jia FU Xianghui YIN Dajun WU Fukun LIU Qing ZANG Haiqing LIU Yuejiang SHI Shifeng MAO Yi YU Baonian WAN Minyou YE Yongcai SHEN EAST team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第10期14-19,共6页
The change in the toroidal rotation of plasma caused by electron cyclotron wave(ECW) injection has been observed in EAST. It is found that the response of the rotation is similar for all possible ECW toroidal inject... The change in the toroidal rotation of plasma caused by electron cyclotron wave(ECW) injection has been observed in EAST. It is found that the response of the rotation is similar for all possible ECW toroidal injection angles. The core toroidal rotation velocity increases in the co-current direction along with a rise in the plasma temperature and stored energy. The profile of the electron temperature, ion temperature and toroidal rotation velocity gradually become peaked.The change in toroidal rotation in the core increases with the ECW injection power. Different behavior is observed when the ECWs are injected into low hybrid current drive(LHCD) target plasmas, where the electron temperature and rotation profile become peaked, while the ion temperature profile flattens after ECW injection, suggesting different transport characteristics in energy and momentum. 展开更多
关键词 ECW plasma toroidal rotation LHCD x-ray crystal spectrometer
下载PDF
Observation of Central Toroidal Rotation Induced by ICRF on EAST
9
作者 潘夏云 王福地 +8 位作者 张新军 吕波 陈俊 李颖颖 符佳 石跃江 余羿 叶民友 万宝年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第2期114-119,共6页
Core plasma rotation of both L-mode and H-mode discharges with ion cyclotron range of frequency(ICRF) minority heating(MH) scheme was measured with a tangential X-ray imaging crystal spectrometer on EAST(Experime... Core plasma rotation of both L-mode and H-mode discharges with ion cyclotron range of frequency(ICRF) minority heating(MH) scheme was measured with a tangential X-ray imaging crystal spectrometer on EAST(Experimental Advanced Superconducting Tokamak).Cocurrent central impurity toroidal rotation change was observed in ICRF-heated L-and H-mode plasmas.Rotation increment as high as 30 km/s was generated at ~1.7 MW ICRF power.Scaling results showed similar trend as the Rice scaling but with significant scattering,especially in L-mode plasmas.We varied the plasma current,toroidal field and magnetic configuration individually to study their effect on L-mode plasma rotation,while keeping the other major plasma parameters and heating unchanged during the scanning.It was found that larger plasma current could induce plasma rotation more efficiently.A scan of the toroidal magnetic field indicated that the largest rotation was obtained for on-axis ICRF heating.A comparison between lower-single-null(LSN)and double-null(DN) configurations showed that LSN discharges rendered a larger rotation change for the same power input and plasma parameters. 展开更多
关键词 central toroidal rotation ICRF flow drive minority heating X-ray imaging crystal spectrometer
下载PDF
The optimum scheme of a static Fourier-transform spectrometer based on birefringent crystal 被引量:2
10
作者 张冬青 吴福全 范树海 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第6期326-328,共3页
An optimum design of static Fourier-transform spectrometer based on Savert prisms is presented in this paper. A new method of increasing path difference and resolution of spectrometer is given. When the angle between ... An optimum design of static Fourier-transform spectrometer based on Savert prisms is presented in this paper. A new method of increasing path difference and resolution of spectrometer is given. When the angle between the crystal optical axis of the first Savert prism and the incident interface is 58° and the angle between the crystal optical axis of the second Savert prism and the incident interface is 28°, the maximum path difference will be 0.63 mm, the maximum resolution will be 15.8 cm-1, and the whole field-of-view will reach 6°. 展开更多
关键词 of de it In The optimum scheme of a static Fourier-transform spectrometer based on birefringent crystal VIEW into on BE from
原文传递