This report presents a design system based on the use of CsI(TI) detectors to search for lost radioactive sources that are dangerous and harmful to individuals, including searching persons. For this purpose, the GEANT...This report presents a design system based on the use of CsI(TI) detectors to search for lost radioactive sources that are dangerous and harmful to individuals, including searching persons. For this purpose, the GEANT4 simulation toolkit was utilized to develop a system based on three detectors. Various simulated analyses were performed on the dose rates of the three detectors using different source–detector distances and detector separation. There were good agreement between the simulated results and the experimentally measured data. A new method was discussed to detect and search for radioactive sources based only on the dose rates in detectors with source activity. Numerical analyses were performed based on the measured dose rates and the difference of distances to determine the actual location of the lost single or multiple γ-ray sources at a specific angle. The detection limit was calculated from the background radiation to establish the sensitivity and capability of the proposed detector system. This system can be applied in fields in which it is necessary to locate unknown radioactive sources.展开更多
The performance test of a CsI(Tl) crystal (70×27×23 mm3) was performed by applying the pulse shape discrimination technique for identification of light charged particles .The crystal is coupled to a photomul...The performance test of a CsI(Tl) crystal (70×27×23 mm3) was performed by applying the pulse shape discrimination technique for identification of light charged particles .The crystal is coupled to a photomultiplier tube during an experiment with 6He beam.The pulse waveform is fully recorded by employing a high precision digital oscilloscope.The fast and slow gates are used for the pulse shape discrimination and the best values for the gate widths were determined to be 0.5 μs and 1.67 μs,respectively.The 6He,4He and 3He are successfully discriminated with this technique.展开更多
In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a...In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.展开更多
介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的...介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的线性度并增强了系统的稳定性。实验表明:读出电路噪声为51.08 f C+1.97 f C/p F,时间漂移为0.112%,探头对137Cs源γ射线的输出信号信噪比可达23:1,能量分辨率可达4.98%。展开更多
The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for cr...The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for crays detection is studied by comparison between the experimental measurements and GEANT4 simulation. The reliability of the simulated efficiency for low-energy γ-rays is verified by comparing with the experimental data. The efficiency of the Cs I detector for high-energy γ-rays was obtained by the GEANT4 simulation. The simulation shows that the detection efficiency of 20 Me V γ-rays can reach 3.8%.展开更多
基金Xi’an Jiaotong University and was fully supported by key research and development plan of Shandong Province(No.2017CXGC0916)and the Chinese government
文摘This report presents a design system based on the use of CsI(TI) detectors to search for lost radioactive sources that are dangerous and harmful to individuals, including searching persons. For this purpose, the GEANT4 simulation toolkit was utilized to develop a system based on three detectors. Various simulated analyses were performed on the dose rates of the three detectors using different source–detector distances and detector separation. There were good agreement between the simulated results and the experimentally measured data. A new method was discussed to detect and search for radioactive sources based only on the dose rates in detectors with source activity. Numerical analyses were performed based on the measured dose rates and the difference of distances to determine the actual location of the lost single or multiple γ-ray sources at a specific angle. The detection limit was calculated from the background radiation to establish the sensitivity and capability of the proposed detector system. This system can be applied in fields in which it is necessary to locate unknown radioactive sources.
基金Supported by National Basic Research Program (973 Program) of China (2007CB815002)NSFC (10775003,10827505)
文摘The performance test of a CsI(Tl) crystal (70×27×23 mm3) was performed by applying the pulse shape discrimination technique for identification of light charged particles .The crystal is coupled to a photomultiplier tube during an experiment with 6He beam.The pulse waveform is fully recorded by employing a high precision digital oscilloscope.The fast and slow gates are used for the pulse shape discrimination and the best values for the gate widths were determined to be 0.5 μs and 1.67 μs,respectively.The 6He,4He and 3He are successfully discriminated with this technique.
基金supported by the National Natural Science Foundation of China (Nos.12275007, U1867214, 11775004)the funding from the State Key Laboratory of Nuclear Physics and Technology,Peking University,China (No. NPT2021ZZ01)funding from heavy Ion Research Facility,Lanzhou,China (No. HIR2021PY002)。
文摘In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.
文摘介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的线性度并增强了系统的稳定性。实验表明:读出电路噪声为51.08 f C+1.97 f C/p F,时间漂移为0.112%,探头对137Cs源γ射线的输出信号信噪比可达23:1,能量分辨率可达4.98%。
文摘研究了封装反射层材料对GAGG:Ce探测器光收集的影响,同时与Na I(TI)闪烁体探测器进行了详细的对比性实验,用137Cs、60Co标准源测量了γ能谱,对GAGG:Ce与Na I(TI)闪烁体探测器的温漂、能量线性及能量分辨率等性能指标重点进行了讨论。结果表明:GAGG:Ce探测器随温度漂移变化程度较大;能量线性好,线性相关度r为0.9999;对662 ke V的γ射线能量分辨率为7.8~8.0%。
基金supported by the Major State Basic Research Development Program of China(No.2013CB834405)the National Natural Science Foundation of China(Nos.11421505,11475244,and 11175231)
文摘The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for crays detection is studied by comparison between the experimental measurements and GEANT4 simulation. The reliability of the simulated efficiency for low-energy γ-rays is verified by comparing with the experimental data. The efficiency of the Cs I detector for high-energy γ-rays was obtained by the GEANT4 simulation. The simulation shows that the detection efficiency of 20 Me V γ-rays can reach 3.8%.