期刊文献+
共找到22篇文章
< 1 2 >
每页显示 20 50 100
Two annular CsI(Tl) detector arrays for the charged particle telescopes
1
作者 Hong-Yu Zhu Jian-Ling Lou +19 位作者 Yan-Lin Ye Li-Sheng Yang Bo-Long Xia Kang Wei Ying Chen Wei-Liang Pu Zi-Yao Hu Hao-Yu Ge Jia-Hao Chen Kai Ma Wen-Wu Wan Hooi-Jin Ong Yan-Yun Yang Shi-Wei Xu Kang Wang Fang-Fang Duan Jun-Bin Ma Zhen Bai Peng Ma Ruo-Fu Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期158-165,共8页
In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a... In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method. 展开更多
关键词 Wedge-shaped csi(tl)detector Light output non-uniformity Si-csi(tl)telescope Particle identification
下载PDF
CsI(Tl)闪烁探测器脉冲形状鉴别最优积分条件的探究方法
2
作者 刘玲 王凤兰 +8 位作者 孙晓慧 李鹏程 黄年伟 刘佳丽 刘顺菊 刘丝雨 吴茂盛 池铭璇 王建松 《沈阳师范大学学报(自然科学版)》 CAS 2023年第3期261-267,共7页
介绍了脉冲波形分析中用电荷积分法鉴别带电粒子的方法,给出了CsI(Tl)脉冲波形粒子鉴别能力的评估方法。用VME(versa module eurocard)数据获取系统的电荷积分插件QDC和基于PXI(PCI extensions for Instrumentation)的XIA获取系统获取Cs... 介绍了脉冲波形分析中用电荷积分法鉴别带电粒子的方法,给出了CsI(Tl)脉冲波形粒子鉴别能力的评估方法。用VME(versa module eurocard)数据获取系统的电荷积分插件QDC和基于PXI(PCI extensions for Instrumentation)的XIA获取系统获取CsI(Tl)闪烁探测器的脉冲信号波形各有优缺点。相较于过去在实验中利用QDC电子学插件对闪烁体的脉冲波形做快、慢成分的在线积分处理,该研究在XIA获取系统采集的CsI(Tl)闪烁体真实脉冲波形基础上,利用ROOT数据分析软件,在离线数据处理过程中利用程序调整积分门的延迟和宽度,研究了积分门的延迟和宽度的变化对探测器粒子鉴别能力的影响。定义了一种简单、明了的判断方法,通过比较2种不同粒子在二维鉴别谱中的分布距离来判断在不同积分门延迟和宽度下粒子的鉴别能力并研究其变化规律,探究该方法的可行性,为以后采用电荷积分插件实验提供参考。 展开更多
关键词 csi(tl)闪烁探测器 脉冲形状分析 带电粒子鉴别 积分法
下载PDF
半导体探测器的厚度确定及CsI(Tl)的刻度 被引量:4
3
作者 魏志勇 段利敏 +9 位作者 吴和宇 靳根明 李祖玉 张保国 王宏伟 肖志刚 柳永英 王素芳 诸永泰 胡荣江 《核技术》 CAS CSCD 北大核心 2001年第6期468-472,共5页
根据核反应过程中发射带电粒子在硅半导体中的最大能量沉积 ,利用带电粒子在硅半导体中的阻止本领曲线 ,同时实现半导体探测器的厚度确定及与之组合的CsI(Tl)
关键词 能量刻度 半导体探测器 厚度 碘化铯晶体
下载PDF
中能重离子在位置灵敏CsI(Tl)探测器中能损与光输出响应的关系 被引量:4
4
作者 武大鹏 章学恒 +13 位作者 杨彦云 姚向武 王建松 胡正国 陈金达 唐彬 臧永东 岳珂 涂小林 徐治国 陈若富 付芬 徐瑚珊 詹文龙 《核技术》 CAS CSCD 北大核心 2009年第7期550-555,共6页
描述了一种双维位置灵敏CsI(Tl)探测器的结构及其读出系统,用中能次级束研究其能损与光输出关系。使用Bρ+(ΔE-TOF)方法鉴别次级束,刻度了CsI(Tl)探测器位置信号的线性,并用其光输出与入射粒子的A、Z关系刻度其能量。结果表明,CsI(Tl)... 描述了一种双维位置灵敏CsI(Tl)探测器的结构及其读出系统,用中能次级束研究其能损与光输出关系。使用Bρ+(ΔE-TOF)方法鉴别次级束,刻度了CsI(Tl)探测器位置信号的线性,并用其光输出与入射粒子的A、Z关系刻度其能量。结果表明,CsI(Tl)探测器输出信号的ADC读出与QDC读出(即其光输出)有很好的线性关系。 展开更多
关键词 csi(tl)探测器 光输出 能损 能量刻度
下载PDF
HIRFL-CSRm内靶实验终端CsI(Tl)电磁量能器性能模拟 被引量:3
5
作者 李文飞 徐瑚珊 +12 位作者 孙志宇 肖国青 詹文龙 郭忠言 段利敏 李加兴 徐华根 陈若富 张雪荧 贾飞 祁辉荣 马越 张宏斌 《原子核物理评论》 CAS CSCD 北大核心 2004年第4期309-311,共3页
基于GEANT4模拟了HIRFL CSRm内靶实验终端的CsI(Tl)电磁量能器系统,给出了CsI电磁量能器的最佳设计参数及可能达到的性能.结果表明,设计的CsI(Tl)电磁量能器系统能够满足所研究的物理要求.
关键词 电磁量能器 HIRFL CSR GEANT4 实验 系统 物理
下载PDF
CsI(Tl)闪烁探测器读出电路设计 被引量:1
6
作者 李元东 葛良全 +5 位作者 张开琪 侯铁钢 邱腾 刘毅 孙坤 盛磊 《核电子学与探测技术》 CAS 北大核心 2016年第11期1138-1141,共4页
介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的... 介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的线性度并增强了系统的稳定性。实验表明:读出电路噪声为51.08 f C+1.97 f C/p F,时间漂移为0.112%,探头对137Cs源γ射线的输出信号信噪比可达23:1,能量分辨率可达4.98%。 展开更多
关键词 csi(tl)探测器 读出电路 能谱响应 输出波形 能量分辨率
下载PDF
双维位置灵敏CsI(Tl)闪烁探测器 被引量:2
7
作者 胡强 李加兴 《原子核物理评论》 CAS CSCD 北大核心 2008年第1期52-55,共4页
介绍了一种双维位置灵敏CsI(Tl)闪烁探测器,利用GEANT4对它进行了蒙特卡罗模拟,得到了RIB17N的位置分布谱及探测器的空间位置分辨,模拟结果与实验测量值很好地吻合。给出了影响探测器分辨的主要因素及改进方案。
关键词 GEANT4 csi(tl)闪烁探测器 位置分辨 反射系数
下载PDF
高温气冷堆球流检测系统中CsI(Tl)探测器温度影响研究 被引量:1
8
作者 卢建超 刘锡明 +1 位作者 万欣 吴志芳 《原子能科学技术》 EI CAS CSCD 北大核心 2018年第3期533-538,共6页
为保证球床式高温气冷堆(PB-HTGR)球流检测系统投影数据获取过程中输出信号的稳定性,需对探测模块输出暗电流的稳定性进行分析。本文随机选取了2组CsI(Tl)探测器模块作为研究对象,并专门设计了温度及暗电流的控制和测量装置,分析了模块... 为保证球床式高温气冷堆(PB-HTGR)球流检测系统投影数据获取过程中输出信号的稳定性,需对探测模块输出暗电流的稳定性进行分析。本文随机选取了2组CsI(Tl)探测器模块作为研究对象,并专门设计了温度及暗电流的控制和测量装置,分析了模块暗电流的输出特性及其控制要求。实验结果表明:各探测单元输出暗电流随温度的变化呈近似指数变化,且室温下温度波动±2℃时第32路单元的暗电流波动达8pA。因此需对探测系统进行温度控制,同时分析实验数据并结合暗电流稳定性的控制要求,提出检测系统的最佳温控范围为(18~22)℃,对应的温控精度为(±0.92~±0.21)℃。 展开更多
关键词 高温气冷堆球流检测系统 csi(tl)探测器模块 暗电流 温度影响
下载PDF
CsI(Tl)闪烁晶体研究进展 被引量:13
9
作者 郭亚军 杨春晖 《人工晶体学报》 EI CAS CSCD 北大核心 2004年第1期77-80,共4页
CsI(Tl)闪烁晶体光产额高于BGO晶体4倍多,辐照长度较NaI(Tl)晶体短,机械性能好,是一种优良实用的闪烁晶体材料。CsI(Tl)晶体的发光中心包括激活剂发光中心[Tl(Ⅰ)和Tl(Ⅱ)]和辐照诱导缺陷发光中心。CsI(Tl)晶体的发射谱峰值位于550nm,... CsI(Tl)闪烁晶体光产额高于BGO晶体4倍多,辐照长度较NaI(Tl)晶体短,机械性能好,是一种优良实用的闪烁晶体材料。CsI(Tl)晶体的发光中心包括激活剂发光中心[Tl(Ⅰ)和Tl(Ⅱ)]和辐照诱导缺陷发光中心。CsI(Tl)晶体的发射谱峰值位于550nm,能与硅光二极管配合组成性能优良的探测器,广泛应用于核技术和高能物理等领域。目前主要采用坩埚下降法和连续加料法生长。本文综述了CsI(Tl)闪烁晶体的生长、缺陷、闪烁性能及其应用领域的研究与发展趋势。 展开更多
关键词 闪烁晶体 探测器 csi(tl) 晶体生长 闪烁性能 激活剂 探测器 核技术 中微子探测
下载PDF
Study on the performance of a large-size CsI detector for high energy γ-rays 被引量:4
10
作者 He Dong De-Qing Fang Chen Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第1期58-64,共7页
The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for cr... The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for crays detection is studied by comparison between the experimental measurements and GEANT4 simulation. The reliability of the simulated efficiency for low-energy γ-rays is verified by comparing with the experimental data. The efficiency of the Cs I detector for high-energy γ-rays was obtained by the GEANT4 simulation. The simulation shows that the detection efficiency of 20 Me V γ-rays can reach 3.8%. 展开更多
关键词 csi:tl Scintillation detector Full ABSORPTION efficiency Energy RESOLUTION GEANT4 simulation
下载PDF
CsI(Tl)探测阵列的升级及测试
11
作者 万文武 楼建玲 +3 位作者 朱宏渝 夏博龙 葛浩煜 叶沿林 《原子核物理评论》 CAS CSCD 北大核心 2024年第1期445-452,共8页
在中低能放射性核束物理实验中,硅和CsI(Tl)探测器通常组成Si-CsI(Tl)望远镜,利用ΔE-E方法鉴别带电粒子。CsI(Tl)探测器的光输出大小、光输出均匀度以及配套的获取系统等对其性能和望远镜的粒子鉴别能力有重要影响。本工作尝试从改换Cs... 在中低能放射性核束物理实验中,硅和CsI(Tl)探测器通常组成Si-CsI(Tl)望远镜,利用ΔE-E方法鉴别带电粒子。CsI(Tl)探测器的光输出大小、光输出均匀度以及配套的获取系统等对其性能和望远镜的粒子鉴别能力有重要影响。本工作尝试从改换CsI(Tl)晶体的包装材料、光电转换设备等方面提高光输出,改善探测器的长期稳定性和楔形探测器的光输出不均匀度;还测试对比了不同获取系统对CsI(Tl)探测器性能的影响,结果表明,最优参数下的数字化获取系统在能量分辨率和获取效率方面优于传统获取系统。 展开更多
关键词 csi(tl)探测器 光输出 能量分辨率 数字化获取系统 梯形滤波
原文传递
LaBr_(3)(Ce)-CsI(Tl)紧凑式叠层反康伽马探测器研制
12
作者 李天晓 吴鸿毅 +8 位作者 郑云 李聪博 竺礼华 吴晓光 陆景彬 郑敏 赵子豪 陈若富 魏建德 《原子核物理评论》 CAS CSCD 北大核心 2023年第1期73-77,共5页
本工作研制了一套由圆柱形LaBr_(3)(Ce)主晶体和井形CsI(Tl)次晶体组成的叠层伽马探测器,该探测器主要用于鉴别来自LaBr_(3)(Ce)主晶体的康普顿散射光子并进行反符合测量。两种不同的晶体耦合到同一个光电倍增管上。入射辐射沉积在每一... 本工作研制了一套由圆柱形LaBr_(3)(Ce)主晶体和井形CsI(Tl)次晶体组成的叠层伽马探测器,该探测器主要用于鉴别来自LaBr_(3)(Ce)主晶体的康普顿散射光子并进行反符合测量。两种不同的晶体耦合到同一个光电倍增管上。入射辐射沉积在每一层探测器的能量,可以通过PMT给出的信号脉冲形状差异进行识别。利用Geant4模拟结果,验证了脉冲形状甄别性能和康普顿散射抑制效果。利用^(60)Co伽马源对探测器进行了实验测试,测试结果表明,该探测器本底抑制系数为2.33(1),达到了康普顿本底抑制两倍以上的预期目标。 展开更多
关键词 紧凑式叠层伽马探测器 LaBr_(3)(Ce) csi(tl) 脉冲形状甄别 蒙特卡罗模拟
原文传递
硅PIN光敏二极管探测X、γ射线的性能及应用 被引量:7
13
作者 任雪光 宁传刚 +3 位作者 邓景康 卢杰 王延峰 郑晓超 《核电子学与探测技术》 CAS CSCD 北大核心 2003年第1期30-32,29,共4页
介绍了硅PIN光敏二极管和电荷灵敏前放组成的X射线探测器和配合CsI(Tl)晶体构成的γ射线探测器的性能和测量结果,同时研究了光敏二极管探测器能量分辨率的温度特性。测量X射线时,在-10℃下对241Am的59.5keV射线的能量分辨率为4.8%;用PI... 介绍了硅PIN光敏二极管和电荷灵敏前放组成的X射线探测器和配合CsI(Tl)晶体构成的γ射线探测器的性能和测量结果,同时研究了光敏二极管探测器能量分辨率的温度特性。测量X射线时,在-10℃下对241Am的59.5keV射线的能量分辨率为4.8%;用PIN光敏二极管配合10mm×10mm×10mm的CsI(Tl)晶体测量γ射线时,在20℃下对137Cs0.662MeVγ射线的能量分辨率为9.9%,60Co的1.332MeVγ射线的能量分辨率为6.4%,-10℃下的能量分辨率分别为8.7%和6.3%。 展开更多
关键词 PIN光敏二极管探测器 csi(tl)晶体 温度特性
下载PDF
ΔE-E望远镜在~9C碎裂反应上的应用 被引量:4
14
作者 金仕纶 王建松 +14 位作者 王猛 胡正国 张雪荧 陈若富 王琦 陈志强 黄美容 郑川 杨彦云 严鑫帅 袁小华 韩建龙 马朋 付芬 胡强 《原子能科学技术》 EI CAS CSCD 北大核心 2012年第4期385-389,共5页
为研究9 C的晕核结构,一套ΔE-E望远镜探测器应用在兰州放射性次级束流线(RIBLL)上进行的9 C碎裂反应实验中,用来测量反应中产生的碎片。为解决ΔE-E望远镜中硅条的干扰问题及硅条和CsI的能量刻度,利用硅条的感应信号对重离子在硅条上... 为研究9 C的晕核结构,一套ΔE-E望远镜探测器应用在兰州放射性次级束流线(RIBLL)上进行的9 C碎裂反应实验中,用来测量反应中产生的碎片。为解决ΔE-E望远镜中硅条的干扰问题及硅条和CsI的能量刻度,利用硅条的感应信号对重离子在硅条上产生的饱和信号进行能量刻度,并通过模拟程序与事例得到的刻度点对CsI(Tl)晶体进行能量刻度。同时使用在硅条和CsI(Tl)晶体上的位置信息对反应物径迹进行重建,从而得到同一离子在硅条与CsI(Tl)晶体上信号的符合,并得到了最终的有效物理事件。 展开更多
关键词 ΔE-E望远镜 硅条饱和信号 csi(tl)晶体刻度 径迹拟合
下载PDF
双维位置灵敏CsI(Tl)探测器 被引量:1
15
作者 李琛 詹文龙 +10 位作者 肖国青 郭忠言 孙志宇 李加兴 陈志强 王猛 王武生 毛瑞士 陈立新 白洁 胡正国 《高能物理与核物理》 EI CSCD 北大核心 2005年第3期278-281,共4页
描述了一种双维位置灵敏CsI(Tl)探测器 .用 3组分α源测量该探测器得到的位置分辨为0 .81mm(FWHM) ,对于 6 9MeV/u36 Ar能量分辨为 0 .9% (FWHM) .在RIBLL的ΔE E粒子鉴别望远镜中常常作为E探测器 .由于CsI(Tl)晶体对不同的粒子的能损 ... 描述了一种双维位置灵敏CsI(Tl)探测器 .用 3组分α源测量该探测器得到的位置分辨为0 .81mm(FWHM) ,对于 6 9MeV/u36 Ar能量分辨为 0 .9% (FWHM) .在RIBLL的ΔE E粒子鉴别望远镜中常常作为E探测器 .由于CsI(Tl)晶体对不同的粒子的能损 -光输出的非线性 ,需要针对不同离子对CsI探测器作能量 光输出校正曲线 . 展开更多
关键词 重离子加速器 放射性物理 探测器 粒子鉴别望远镜
原文传递
工业CT阵列探测器串扰率的蒙卡模拟 被引量:2
16
作者 林俏露 李公平 +1 位作者 王玮 刘星 《甘肃科学学报》 2012年第4期29-31,共3页
阵列探测器的串扰率对工业CT系统图像重建有重要影响,通过构建W金属隔板的X射线阵列探测器的物理模型,用蒙特卡罗法模拟了阵列探测的串扰率.结果表明:在X射线能量分别为60keV、100keV、140keV时,W金属隔板能有效降低串扰率.结合MTF函数... 阵列探测器的串扰率对工业CT系统图像重建有重要影响,通过构建W金属隔板的X射线阵列探测器的物理模型,用蒙特卡罗法模拟了阵列探测的串扰率.结果表明:在X射线能量分别为60keV、100keV、140keV时,W金属隔板能有效降低串扰率.结合MTF函数分析,得出射线能量小于140keV的最佳W金属隔板的厚度为0.3mm. 展开更多
关键词 csi(tl)阵列探测器 蒙卡模拟 串扰率 金属隔板
下载PDF
研制一个用于研究(中子,带电粒子)反应的望远镜系统
17
作者 范扬眉 王书富 +3 位作者 叶邦角 韩荣典 翁惠民 肖振喜 《原子能科学技术》 EI CAS CSCD 北大核心 1992年第1期21-25,共5页
文章讨论了一个研究(中子,带电粒子)反应双微分截面多路望远镜系统中△E和E探测器的选择、制作、刻度及性能测试。对CsI(Tl)探测器的非线性能量响应关系进行了精心刻度。研制的CsI(Tl)探测器,其性能达到国外同类装置的水平。
关键词 望远镜 中子 带电粒子 探测器
下载PDF
大面积高灵敏度编码相机探测器的设计与性能测试 被引量:2
18
作者 李岩 王强 +9 位作者 黄先超 帅磊 曹大泉 张译文 杨曜 胡选侯 梁秀佐 吴俊 曾国强 章志明 《核技术》 CAS CSCD 北大核心 2020年第5期31-36,共6页
编码孔径相机是一种定位放射性物质的设备,对丢失放射性物质的寻找以及监测具有重要的意义。为了满足编码孔径相机对核突发事故的污染区进行实时定位,并获得污染面积和污染程度等信息,采用大面积CsI(Tl)晶体阵列与光电倍增管(PhotoMulti... 编码孔径相机是一种定位放射性物质的设备,对丢失放射性物质的寻找以及监测具有重要的意义。为了满足编码孔径相机对核突发事故的污染区进行实时定位,并获得污染面积和污染程度等信息,采用大面积CsI(Tl)晶体阵列与光电倍增管(PhotoMultiplier Tube,PMT)阵列耦合的方式构建高灵敏度编码相机的探测器,以此提高探测效率并减少探测时间。该探测器由121根CsI(Tl)晶体构成11×11的阵列,每根晶体的尺寸为15 mm×15 mm×15 mm,通过光导与3×3的光电倍增管阵列耦合为一个探测器模块;由4个探测器模块组成2×2的阵列作为探头部件,采用自主设计的放大滤波成型以及单端转差分电路实现探测器信号的读出处理。通过测试发现,该探测器模块在662 keV的γ射线激发下,能很好地实现各个晶体条的位置分辨,且其平均能量分辨率为9.4%。测试结果表明:该探测器在位置分辨、能量分辨率、峰位一致性以及探测效率一致性等性能方面均能够满足高灵敏度编码相机成像的设计要求。 展开更多
关键词 位置灵敏探测器 csi (tl)晶体阵列 光电倍增管 编码孔径γ 相机
下载PDF
基于硅光二极管阵列的X射线探测器的研制 被引量:2
19
作者 武志宗 江美玲 梁平治 《核技术》 EI CAS CSCD 北大核心 2005年第11期884-888,共5页
介绍了10元CsI(Tl)闪烁晶体与10元硅光二极管阵列耦合而成的X射线探测器的设计制造过程。其中,二极管光敏元为0.75mm×1.25mm的窄条形,中心距为1.25mm,外观尺寸为12.5mm×1.25mm;闪烁体单元为1.0mm×1.5mm的窄条形,中心距为... 介绍了10元CsI(Tl)闪烁晶体与10元硅光二极管阵列耦合而成的X射线探测器的设计制造过程。其中,二极管光敏元为0.75mm×1.25mm的窄条形,中心距为1.25mm,外观尺寸为12.5mm×1.25mm;闪烁体单元为1.0mm×1.5mm的窄条形,中心距为1.25mm,外观尺寸为12.5mm×1.9mm。对该探测器的硅光二极管进行了光谱测试和噪声测试,对射线探测器进行了串音和均匀性等性能测试。二极管的噪声为10?4V,射线探测器的非均匀性为0.08,有串音现象发生。对存在的问题进行了分析讨论并提出了改进方案。 展开更多
关键词 光敏二极管 csi(T1)闪烁晶体 X射线探测器
下载PDF
暗物质寻找实验中CsI(Tl)晶体反符合探测器实验研究(英文)
20
作者 何道 李玉兰 +7 位作者 岳骞 李元景 李金 程建平 KWAK J W KIM S K 李昕 王子敬 《高能物理与核物理》 CSCD 北大核心 2006年第6期548-553,共6页
一个正在建设的位于韩国Y2L地下实验室的低能暗物质探测实验中,采用了CsI(Tl)晶体反符合探测器作为主动屏蔽体.本工作对CsI(Tl)晶体反符合探测器的实验性能进行了研究.通过FADC系统记录的脉冲波形数据,研究了探测器的能量分辨率和波... 一个正在建设的位于韩国Y2L地下实验室的低能暗物质探测实验中,采用了CsI(Tl)晶体反符合探测器作为主动屏蔽体.本工作对CsI(Tl)晶体反符合探测器的实验性能进行了研究.通过FADC系统记录的脉冲波形数据,研究了探测器的能量分辨率和波形甄别的能力;研究相同能量γ射线入射到反符合探测器不同位置的相对光输出将有助于选择探测器的工作参数;为了解晶体自身放射性对暗物质测量的影响,利用低本底HPGe探测器对CsI(Tl)晶体内部的放射性进行了测量,得到晶体内部Cs同位素的放射性活度.探测器系统进行了约18d的试运行取数.实验数据表明,CsI(Tl)晶体探测器的反符合效率约为31%,HPGe探测器的本底计数率水平约为 133cpd.为了进行暗物质探测研究,需要采取有效的方法进一步降低探测器的本底水平. 展开更多
关键词 暗物质 csi(tl)探测器 脉冲形状甄别 内部本底
原文传递
上一页 1 2 下一页 到第