期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Development of x-ray scintillator functioning also as an analyser grating used in grating-based x-ray differential phase contrast imaging 被引量:4
1
作者 雷耀虎 刘鑫 +2 位作者 郭金川 赵志刚 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第4期222-227,共6页
In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating,... In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating, which has been proposed for grating-based x-ray differential phase contrast imaging. According to this design, the scintillator should have a periodical structure in one dimension with the pitch equaling the period of self-image of the phase grating at the Talbot distance, where one half of the pitch is pixellated and is made of x-ray sensitive fluorescent material, such as CsI(T1), and the remaining part of the pitch is made of x-ray insensitive material, such as silicon. To realize the design, a deep pore array with a high aspect ratio and specially designed grating pattern are successfully manufactured on 5 inch silicon wafer by the photo-assisted electrochemical etching method. The related other problems, such as oxidation-caused geometrical distortion, the filling of CsI(T1) into deep pores and the removal of inside bubbles, have been overcome. Its pixel size, depth and grating pitch are 3 p.m^7.5 ~m, 150 p^m and 3 Ixm, respectively. The microstructure of the scintillator has been examined microscopically and macroscopically by scanning electron microscope and x-ray resolution chart testing, respectively. The preliminary measurements have shown that the proposed scintillator, also functioning as an analyser grating, has been successfully designed and developed. 展开更多
关键词 scintillator screen pore arrays oxidation csi(t1) analyser grating
下载PDF
Measurement of intrinsic radioactive backgrounds from the ^(137)Cs and U/Th chains in CsI(Tl) crystals
2
作者 刘书魁 岳骞 +7 位作者 林兴德 李元景 唐昌建 王子敬 幸浩洋 杨朝文 赵伟 朱敬军 《Chinese Physics C》 SCIE CAS CSCD 2015年第4期55-62,共8页
The inorganic CsI(Tl) crystal scintillator is a candidate anti-compton detector for the China Dark matter Experiment. Studying the intrinsic radiopurity of the CsI(Tl) crystal is an issue of major importance. The ... The inorganic CsI(Tl) crystal scintillator is a candidate anti-compton detector for the China Dark matter Experiment. Studying the intrinsic radiopurity of the CsI(Tl) crystal is an issue of major importance. The timing, energy and spatial correlations, as well as the capability of pulse shape discrimination provide powerful methods for the measurement of intrinsic radiopurities. The experimental design, detector performance and event-selection algorithms are described. A total of 359×3 kg-days data from three prototypes of CsI(Tl) crystals were taken at China Jinping Underground Laboratory (CJPL), which offers a good shielding environment. The contamination levels of internal isotopes from 137Cs, 232Th and 238U series, as well as the upper bounds of 235U series are reported. Identification of the whole α peaks from U/Th decay chains and derivation of those corresponding quenching factors are achieved. 展开更多
关键词 scintillation detector csi(t1) crystal intrinsic radiopurity alpha
原文传递
Performance evaluation of CsI screens for X-ray imaging
3
作者 赵博震 秦秀波 +4 位作者 冯召东 魏存峰 陈研 王宝义 魏龙 《Chinese Physics C》 SCIE CAS CSCD 2014年第11期39-44,共6页
CsI film has been one of the most extensively used scintillators for indirect X-ray imaging because of its needle-like micro-structure. The purpose of this paper is to investigate the imaging performance of CsI screen... CsI film has been one of the most extensively used scintillators for indirect X-ray imaging because of its needle-like micro-structure. The purpose of this paper is to investigate the imaging performance of CsI screen as a function of thickness and radiation quality. Four multilayer scintillation screens with microcolumnar CsI:T1 film (thicknesses of 50 μm, 100 μm, 200μm and 300 μm) included were prepared and coupled to an optical imaging sensor. The modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of these screens were evaluated based on the standard IEC 62220-1, and the results indicated that, in the medium spatial frequency range (1-6 lp/mm), the MTF of CsI screens with the same thickness was lower when the incident X-ray photon energy was higher, possibly owing to scattering and K-fluorescence re-absorption effects. The NNPS in the higher spatial frequency range (above 8 lp/mm) is dominated by stochastic noise while the entrance surface air Kerma (ESAK) decreases. For 100 μm, 200 μm and 300 μm thick CsI screens, the DQE under RQA7 and RQA9 is lower than that under RQA3 and RQA5 due to low absorption efficiency. 展开更多
关键词 microcolumnar csit1 film scintillation screen DQE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部