In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a...In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.展开更多
NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution ...NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution of these detectors,which detracts from an accurate analysis of the instrument spectra obtained,remains a crucial need.Based on the physical properties and spectrum formation processes of NaI(T1) scintillation detectors,the detector response to gamma photons with different energies is represented by photopeaks that are approximately Gaussian in shape with unique full-width-at-half-maximum(FWHM) values.The FWHM is established as a detector parameter based on resolution calibrations and is used in the construction of a general Gaussian response matrix,which is employed for the inverse decomposition of gamma spectra obtained from the detector.The Gold and Boosted Gold iterative algorithms are employed to accelerate the decomposition of the measured spectrum.Tests of the inverse decomposition method on multiple simulated overlapping peaks and on experimentally obtained U and Th radionuclide series spectra verify the practicability of the method,particularly in the low-energy region of the spectrum,providing for the accurate qualitative and quantitative analysis of radionuclides.展开更多
The Na I(Tl) scintillation detector has a number of unique advantages, including wide use, high light yield,and its low price. It is difficult to obtain the decomposition of instrument response spectrum because of lim...The Na I(Tl) scintillation detector has a number of unique advantages, including wide use, high light yield,and its low price. It is difficult to obtain the decomposition of instrument response spectrum because of limitations associated with the Na I(Tl) scintillation detector's energy resolution. This paper, based on the physical process of c photons released from decay nuclides, generating an instrument response spectrum, uses the Monte Carlo method to simulate c photons with Na I(Tl) scintillation detector interaction. The Monte Carlo response matrix is established by different single energy γ-rays with detector effects. The Gold and the improved Boosted-Gold iterative algorithms have also been used in this paper to solve the response matrix parameters through decomposing tests,such as simulating a multi-characteristic energy c-ray spectrum and simulating synthesized overlapping peaks cray spectrum. An inversion decomposition of the c instrument response spectrum for measured samples(U series, Th series and U–Th mixed sources, among others)can be achieved under the response matrix. The decomposing spectrum can be better distinguished between the similar energy characteristic peaks, which improve the error levels of activity analysis caused by the overlapping peak with significant effects.展开更多
由闪烁体和光电转换器件构成的闪烁体探测器是工业CT系统中最常用的探测器,其中闪烁体负责将X射线转换为可见光信号,再经过光电转换器件转换为电信号进行探测.闪烁体作为探测器的一部分,其厚度直接影响发光效率和探测分辨性能.本文基于...由闪烁体和光电转换器件构成的闪烁体探测器是工业CT系统中最常用的探测器,其中闪烁体负责将X射线转换为可见光信号,再经过光电转换器件转换为电信号进行探测.闪烁体作为探测器的一部分,其厚度直接影响发光效率和探测分辨性能.本文基于蒙特卡罗仿真平台Geant4建立仿真模型,对碘化铯Cs I(Tl)闪烁体在不同厚度、不同X射线能量(20~80 ke V)下的特性进行模拟,分析闪烁体厚度对闪烁体转换效率以及分辨力的影响.通过仿真获了特定输入能量下对应的闪烁体的理想厚度值.仿真结果可以为闪烁体参数设计和优化提供参考.展开更多
介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的...介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的线性度并增强了系统的稳定性。实验表明:读出电路噪声为51.08 f C+1.97 f C/p F,时间漂移为0.112%,探头对137Cs源γ射线的输出信号信噪比可达23:1,能量分辨率可达4.98%。展开更多
The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for cr...The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for crays detection is studied by comparison between the experimental measurements and GEANT4 simulation. The reliability of the simulated efficiency for low-energy γ-rays is verified by comparing with the experimental data. The efficiency of the Cs I detector for high-energy γ-rays was obtained by the GEANT4 simulation. The simulation shows that the detection efficiency of 20 Me V γ-rays can reach 3.8%.展开更多
In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating...In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.展开更多
基金supported by the National Natural Science Foundation of China (Nos.12275007, U1867214, 11775004)the funding from the State Key Laboratory of Nuclear Physics and Technology,Peking University,China (No. NPT2021ZZ01)funding from heavy Ion Research Facility,Lanzhou,China (No. HIR2021PY002)。
文摘In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method.
基金supported by the National Natural Science Foundation of China(Grant No.11365001)National Major Scientific Equipment Development Projects(Grant No.041514065)+2 种基金the Educational Commission of Jiangxi Province of China(Grant No.GJJ13464)Plan of Science and Technology of Jiangxi Province(Grant No.20141BBE50024)the Fundamental Science on Radioactive Geology and Exploration Technology Laboratory,East China Institute of Technology(Grant No.RGET1316)
文摘NaI(T1) scintillation detectors have been widely applied for gamma-ray spectrum measurements owing to advantages such as high detection efficiency and low price.However,the mitigation of the limited energy resolution of these detectors,which detracts from an accurate analysis of the instrument spectra obtained,remains a crucial need.Based on the physical properties and spectrum formation processes of NaI(T1) scintillation detectors,the detector response to gamma photons with different energies is represented by photopeaks that are approximately Gaussian in shape with unique full-width-at-half-maximum(FWHM) values.The FWHM is established as a detector parameter based on resolution calibrations and is used in the construction of a general Gaussian response matrix,which is employed for the inverse decomposition of gamma spectra obtained from the detector.The Gold and Boosted Gold iterative algorithms are employed to accelerate the decomposition of the measured spectrum.Tests of the inverse decomposition method on multiple simulated overlapping peaks and on experimentally obtained U and Th radionuclide series spectra verify the practicability of the method,particularly in the low-energy region of the spectrum,providing for the accurate qualitative and quantitative analysis of radionuclides.
基金supported by National Natural Science Foundation of China(No.11365001)National Major Scientific Equipment Development Projects(No.041514065)+1 种基金Natural Science Foundation of Jiangxi(No.20161BAB201035)Fundamental Science on Radioactive Geology and Exploration Technology Laboratory,East China Institute of Technology(No.RGET1316)
文摘The Na I(Tl) scintillation detector has a number of unique advantages, including wide use, high light yield,and its low price. It is difficult to obtain the decomposition of instrument response spectrum because of limitations associated with the Na I(Tl) scintillation detector's energy resolution. This paper, based on the physical process of c photons released from decay nuclides, generating an instrument response spectrum, uses the Monte Carlo method to simulate c photons with Na I(Tl) scintillation detector interaction. The Monte Carlo response matrix is established by different single energy γ-rays with detector effects. The Gold and the improved Boosted-Gold iterative algorithms have also been used in this paper to solve the response matrix parameters through decomposing tests,such as simulating a multi-characteristic energy c-ray spectrum and simulating synthesized overlapping peaks cray spectrum. An inversion decomposition of the c instrument response spectrum for measured samples(U series, Th series and U–Th mixed sources, among others)can be achieved under the response matrix. The decomposing spectrum can be better distinguished between the similar energy characteristic peaks, which improve the error levels of activity analysis caused by the overlapping peak with significant effects.
文摘由闪烁体和光电转换器件构成的闪烁体探测器是工业CT系统中最常用的探测器,其中闪烁体负责将X射线转换为可见光信号,再经过光电转换器件转换为电信号进行探测.闪烁体作为探测器的一部分,其厚度直接影响发光效率和探测分辨性能.本文基于蒙特卡罗仿真平台Geant4建立仿真模型,对碘化铯Cs I(Tl)闪烁体在不同厚度、不同X射线能量(20~80 ke V)下的特性进行模拟,分析闪烁体厚度对闪烁体转换效率以及分辨力的影响.通过仿真获了特定输入能量下对应的闪烁体的理想厚度值.仿真结果可以为闪烁体参数设计和优化提供参考.
文摘介绍了配置于新型γ能谱仪的CsI(Tl)闪烁探测器的读出电路设计。输入缓冲级采用折叠嵌位电路,改善了系统频率特性并提高了输入阻抗;放大级采用自举电路,改善了系统动态性能并提高了开环增益;输出级采用电流源负载电路,改善了输出信号的线性度并增强了系统的稳定性。实验表明:读出电路噪声为51.08 f C+1.97 f C/p F,时间漂移为0.112%,探头对137Cs源γ射线的输出信号信噪比可达23:1,能量分辨率可达4.98%。
基金supported by the Major State Basic Research Development Program of China(No.2013CB834405)the National Natural Science Foundation of China(Nos.11421505,11475244,and 11175231)
文摘The measurement of high-energy γ-rays is an important experimental method to study the giant resonance in a nucleus, c reaction in nuclear astrophysics, and so on. The performance of a large-size Cs I detector for crays detection is studied by comparison between the experimental measurements and GEANT4 simulation. The reliability of the simulated efficiency for low-energy γ-rays is verified by comparing with the experimental data. The efficiency of the Cs I detector for high-energy γ-rays was obtained by the GEANT4 simulation. The simulation shows that the detection efficiency of 20 Me V γ-rays can reach 3.8%.
文摘In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.