期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Antibacterial Property of Martensitic Stainless Steel Generated by Cu Ion Implantation
1
作者 XUBo-fan NIHong-wei +2 位作者 DANZhi-gang XIONGJuan XIONGPing-yuan 《材料热处理学报》 EI CAS CSCD 北大核心 2004年第05B期902-904,共3页
Copper ions were implanted into a AISI420 martensitic stainless steel (SS) by metal vapor vacuum arc (MEVVA) with a dose range 0.2 xlO17 -S.OxlO17 cm"2 at the energy of lOOkeV. The Cu-implanted stainless steel wa... Copper ions were implanted into a AISI420 martensitic stainless steel (SS) by metal vapor vacuum arc (MEVVA) with a dose range 0.2 xlO17 -S.OxlO17 cm"2 at the energy of lOOkeV. The Cu-implanted stainless steel was treated by a special antibacterial treatment subsequently. The phase compositions in the implanted layer were studied by glancing X-ray diffraction ( GXRD) and changes of bacterial appearance on the surface of Cu un-implanted SS and Cu-implanted SS with antibacterial treatment SS were observed by bio-TEM (transmission electron microscopy) separately. The results showed that a suitable amount of Cu-rich phase was dispersed in the implanted layer of Cu-implanted SS that was treated by special antibacterial treatment. So the Cu-implanted martensitic stainless steel with antibacterial treatment reveals excellent antibacterial property against both E. coli and S. aureus. 展开更多
关键词 铜离子注入 不锈钢 抗菌处理 马氏体
下载PDF
Microstructure and antibacterial property of stainless steel implanted by Cu ions 被引量:2
2
作者 XU Bo-fan NI Hong-wei XIONG Ping-yuan XIONG Juan DAN Zhi-gang 《中国有色金属学会会刊:英文版》 CSCD 2004年第z1期328-331,共4页
Copper ions were implanted into AISI 304 austenitic stainless steel by metal vapor vacuum are (MEVVA) with 60 - 100 keV energy and a dose range (0.2 - 5.0) × 1017 cm-2. Then Cu-implanted stainless steel was treat... Copper ions were implanted into AISI 304 austenitic stainless steel by metal vapor vacuum are (MEVVA) with 60 - 100 keV energy and a dose range (0.2 - 5.0) × 1017 cm-2. Then Cu-implanted stainless steel was treated by a special antibacterial treatment. Antibacterial rates of Cu-implanted stainless steel, Cu-implanted stainless steel with special antibacterial treatment and un-implanted stainless steel were obtained by agar plate method. Phase composition in the implanted layer was analyzed by glancing X-ray diffraction (GXRD). Microstructure of antibacterial stainless steel was observed with transmission electron microscopy (TEM), and changes of the bacterium appearance after 24 h antibacterial action on the surface of un-implanted and Cu-implanted stainless steel with antibacterial treatment were observed with bio-TEM respectively. The results show that stainless steel obtains antibacterial property against E. coli when the Cu ions dose approaches to the saturated one. A suitable amount of Cu-rich phase uniformly disperses on the surface of Cu-implanted stainless steel that is treated by the special antibacterial treatment. The Cu-rich phase naked on the surface has a function of damage to pericellular membrane and cell wall,the pericellular membrane is thickened and the karyon degraded, and finally, bacteria die. Cu-rich phase naked on the surface endows stainless steel with best antibacterial property. 展开更多
关键词 stainless steel copper ion implantation antibacterial property
下载PDF
EFFECTS OF COPPER ION IMPLANTATION ON ANTIBACTERIAL ACTIVITY OF AISI420 STAINLESS STEEL 被引量:1
3
作者 Z.G.Dan H.W.Ni +2 位作者 B.F.Xu J.Xiong P.Y.Xiong 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2005年第2期153-158,共6页
Antibacterial activity of AISI420 stainless steel (SS) implanted by copper was investigated. Ions extracted from a metal vapor vacuum arc (MEVVA) are sourced with 100keV energy and a dose range from 0.2×1017 to 2... Antibacterial activity of AISI420 stainless steel (SS) implanted by copper was investigated. Ions extracted from a metal vapor vacuum arc (MEVVA) are sourced with 100keV energy and a dose range from 0.2×1017 to 2.0×1017ions·cm-2. The saturation dose of Cu implantation in AISI420 SS and Cu surface concentration were calculated at the energy of 100keV. The effect of dose on the antibacterial activity was analyzed. Results of antibacterial test show that the saturation dose is the optimum implantation dose for best antibacterial activity, which is above 99% against both Escherichia coli and Staphylococcus aureus. Novel phases such as Fe4Cu3 and Cu9.9Fe0.1 were found in the implanted layer by glancing angle X-ray diffraction (GXRD). The antibacterial activity of AISI420 SS attributes to Cu-contained phase. 展开更多
关键词 antibacterial stainless steel copper ion implantation saturation dose cu-contained phase
下载PDF
Antibacterial properties and corrosion resistance of AISI 420 stainless steels implanted by silver and copper ions 被引量:8
4
作者 Hong-wei Ni Han-shuang Zhang Rong-sheng Chen Wei-ting Zhan Kai-fu Huo Zhen-yu Zuo 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2012年第4期322-327,共6页
Silver or copper ions are often chosen as antibacterial agents. But a few reports are concerned with these two antibacterial agents for preparation of antibacterial stainless steel (SS). The antibacterial properties... Silver or copper ions are often chosen as antibacterial agents. But a few reports are concerned with these two antibacterial agents for preparation of antibacterial stainless steel (SS). The antibacterial properties and corrosion resistance of AISI 420 stainless steel implanted by silver and copper ions were investigated. Due to the cooperative antibacterial effect of silver and copper ions, the Ag/Cu implanted SS showed excellent antibacterial activities against both Gram-negative Escherichia coli (E. coli) and Gram-positive Staphylococcus aureus (S. aureus) at a total implantation dose of 2~ 1017 ions/cm2. Electrochemical polarization curves revealed that the corrosion resistance of Ag/Cu implanted SS was slightly enhanced as compared with that of un-implanted SS, The implanted layer was characterized by X-ray photoelec- tron spectroscopy (XPS). Core level XPS spectra indicate that the implanted silver and copper ions exist in metallic state in the implanted layer. 展开更多
关键词 ion implantation antibacterial properties stainless steel Escherichia coli Staphylococcus aureus corrosion resistance
下载PDF
Antibacterial and corrosive properties of copper implanted austenitic stainless steel 被引量:5
5
作者 Juan Xiong Bo-fan Xu Hong-wei Ni 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2009年第3期293-298,共6页
Copper ions were implanted into austenitic stainless steel (SS) by metal vapor vacuum arc with a energy of 100 keV and an ions dose range of (0.5-8.0)× 10^17 cm^-2. The Cu-implanted SS was annealed in an Ar a... Copper ions were implanted into austenitic stainless steel (SS) by metal vapor vacuum arc with a energy of 100 keV and an ions dose range of (0.5-8.0)× 10^17 cm^-2. The Cu-implanted SS was annealed in an Ar atmosphere furnace. Glancing X-ray diffraction (GXRD), transmission electron microscopy (TEM) and Auger electron spectroscopy (AES) were used to reveal the phase compositions, microstructures, and concentration profiles of copper ions in the implanted layer. The results show that the antibacterial property of Cu-implanted SS is attributed to Cu9.9Fe0.1, which precipitated as needles. The depth of copper in Cu-implanted SS with annealing treatment is greater than that in Cu-implanted SS without annealing treatment, which improves the antibacterial property against S. aureus. The salt wetting-drying combined cyclic test was used to evaluate the corrosion-resistance of antibacterial SS, and the results reveal that the antibacterial SS has a level of corrosion-resistance equivalent to that of un-implanted SS. 展开更多
关键词 copper ion implantation stainless steel antibacterial property corrosion resistance
下载PDF
Cu离子注入不锈钢的分子动力学模拟研究 被引量:1
6
作者 高晓晋 陈敬超 +1 位作者 于杰 邹妤 《昆明冶金高等专科学校学报》 CAS 2009年第5期1-4,共4页
采用Lennard-Jones和Morse势函数对Cu离子溅射不锈钢进行了溅射过程与饱和溅射剂量的分子动力学模拟。模拟结果表明:在溅射过程中,Cu将铁从其位置替换,或者在其间隙位置存在;表层Fe发生了晶格损伤,以一种无定型态存在;而扩散模型中,材... 采用Lennard-Jones和Morse势函数对Cu离子溅射不锈钢进行了溅射过程与饱和溅射剂量的分子动力学模拟。模拟结果表明:在溅射过程中,Cu将铁从其位置替换,或者在其间隙位置存在;表层Fe发生了晶格损伤,以一种无定型态存在;而扩散模型中,材料的表层发生了Cu的富集现象,X射线检测表明,该富集相为Cu3Fe4和Cu4Fe。 展开更多
关键词 cu离子注入 抗菌 不锈钢 分子动力学
下载PDF
抗菌处理对含Cu奥氏体抗菌不锈钢组织和性能的影响 被引量:3
7
作者 冯晓钰 程晓英 《上海金属》 CAS 2007年第6期15-18,共4页
研究了含Cu奥氏体抗菌不锈钢的两种抗菌处理方法对其组织、抗菌性能、机械性能和耐腐蚀性能的影响。结果表明:不同的抗菌处理影响了抗菌不锈钢基体中富Cu相的析出,低温长时间抗菌处理得到的组织中富Cu相比高温短时间抗菌处理得到的富Cu... 研究了含Cu奥氏体抗菌不锈钢的两种抗菌处理方法对其组织、抗菌性能、机械性能和耐腐蚀性能的影响。结果表明:不同的抗菌处理影响了抗菌不锈钢基体中富Cu相的析出,低温长时间抗菌处理得到的组织中富Cu相比高温短时间抗菌处理得到的富Cu相更细密,细密的富Cu相对大肠杆菌和金黄色葡萄球菌的抗菌性更好。与304不锈钢相比,含Cu奥氏体抗菌不锈钢经抗菌处理后对机械性能没有产生明显的影响,耐腐蚀性也没有明显的下降。 展开更多
关键词 含铜奥氏体抗菌不锈钢 抗菌处理 富铜相析出 抗菌性能 机械性能 耐腐蚀性能
下载PDF
铜离子注入AISI304不锈钢的抗菌性能研究 被引量:20
8
作者 倪红卫 但智钢 +2 位作者 许伯藩 熊娟 熊平源 《功能材料》 EI CAS CSCD 北大核心 2005年第12期1906-1908,共3页
铜离子由金属蒸汽真空弧(MEVVA)离子注入机引出注入AISI 304不锈钢,采用100keV的能量、(1.0~8.0)×1017ions/cm2的注入剂量.抗菌实验结果表明,铜离子注入试样具有良好的抗大肠杆菌的效果,抗菌处理使得试样具有优良的抗大肠杆菌和... 铜离子由金属蒸汽真空弧(MEVVA)离子注入机引出注入AISI 304不锈钢,采用100keV的能量、(1.0~8.0)×1017ions/cm2的注入剂量.抗菌实验结果表明,铜离子注入试样具有良好的抗大肠杆菌的效果,抗菌处理使得试样具有优良的抗大肠杆菌和金黄色葡萄球菌的效果,且注入量接近饱和注入量时,样品具有最佳的抗菌性能.用小掠射角X射线衍射(GXRD)和透射电镜(TEM)分析了注入层相组成和微观组织,结果表明铜离子注入样品经特殊抗菌处理后,注入层生成了细小分散的富铜相,析出的富铜相使得试样具有优良的抗菌效果. 展开更多
关键词 不锈钢 铜离子注入 抗菌性能
下载PDF
银离子注入剂量对2Cr13Ni2不锈钢耐蚀性能的影响研究 被引量:3
9
作者 倪红卫 詹玮婷 +3 位作者 墙蔷 陈荣生 霍开富 付继江 《功能材料》 EI CAS CSCD 北大核心 2008年第11期1897-1899,共3页
通过测定试样的电化学极化曲线研究了银离子注入2Cr13Ni2不锈钢后的耐蚀性能。采用AES测定了试样注入层中各元素含量沿深度方向的变化规律。研究结果表明:银离子注入2Cr13Ni2不锈钢后,其耐蚀性能与注入前相近。在一定范围内,随注入... 通过测定试样的电化学极化曲线研究了银离子注入2Cr13Ni2不锈钢后的耐蚀性能。采用AES测定了试样注入层中各元素含量沿深度方向的变化规律。研究结果表明:银离子注入2Cr13Ni2不锈钢后,其耐蚀性能与注入前相近。在一定范围内,随注入剂量的增大,不锈钢的耐蚀性能逐步改善。当2×10^17~4×10^17ions/cm^2剂量的银离子注入不锈钢后。其耐蚀性能优于未注入银离子的不锈钢。不锈钢表面及注入层内铬含量的降低是大剂量银离子注入后造成不锈钢耐蚀性能下降的主要原因。 展开更多
关键词 银离子注入 抗菌不锈钢 耐蚀性能
下载PDF
Ag/N离子复合注入刀具不锈钢(AISI420)的表面性能研究 被引量:3
10
作者 王紫阳 倪红卫 +4 位作者 陈荣生 詹玮婷 张超 李有维 李积回 《材料导报(纳米与新材料专辑)》 EI CAS 2014年第1期383-385,共3页
采用MEVVA源和高能气体离子源对刀具不锈钢(AISI420)分别进行N离子、Ag离子和Ag/N离子复合注入,并对注入后的试样进行了硬度、耐磨及抗菌性能的研究。结果表明,N离子的注入能提高不锈钢的硬度和耐磨性能,Ag离子的注入使不锈钢具有优异... 采用MEVVA源和高能气体离子源对刀具不锈钢(AISI420)分别进行N离子、Ag离子和Ag/N离子复合注入,并对注入后的试样进行了硬度、耐磨及抗菌性能的研究。结果表明,N离子的注入能提高不锈钢的硬度和耐磨性能,Ag离子的注入使不锈钢具有优异的抗菌性能,Ag/N离子复合注入使刀具不锈钢的硬度提高了57%,摩擦系数减小了25%,而且具有良好的抗菌性能,对大肠杆菌的杀菌率为95%。 展开更多
关键词 AG N离子注入 刀具不锈钢 抗菌性 表面硬度 耐磨性
下载PDF
银离子注入马氏体不锈钢表面改性研究 被引量:3
11
作者 倪红卫 詹玮婷 +1 位作者 墙蔷 幸伟 《材料热处理学报》 EI CAS CSCD 北大核心 2009年第1期123-126,144,共5页
利用MEVVA源强流离子注入机将银离子注入到马氏体不锈钢表面,注入能量和注入剂量分别为100keV和(0.1~8)×1017ions/cm2。选用革兰氏阳性金黄色葡萄球菌和革兰氏阴性大肠杆菌研究了银离子注入不锈钢的抗菌性能,电化学法测定了其... 利用MEVVA源强流离子注入机将银离子注入到马氏体不锈钢表面,注入能量和注入剂量分别为100keV和(0.1~8)×1017ions/cm2。选用革兰氏阳性金黄色葡萄球菌和革兰氏阴性大肠杆菌研究了银离子注入不锈钢的抗菌性能,电化学法测定了其耐蚀性能,AES分析了不锈钢注入层中主要元素的浓度分布,讨论了注入剂量与不锈钢抗菌性能及耐蚀性能的关系。研究表明:随银离子注入剂量的增加,银在注入层中的峰值浓度变化不大,但分布深度增加,马氏体不锈钢抗菌性能显著提高。在100keV注入能量、8×1017ions/cm2注入剂量条件下,银离子注入马氏体不锈钢后可以使其具有最佳的抗菌性能,但耐蚀性能略有下降。 展开更多
关键词 离子注入 不锈钢 抗菌性能 耐蚀性能
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部