The commercially available inbred obesity-prone C57BL/6J (B6) and outbred stock ICR mice (3-week old) purchased from a breeder of Beijing were weaned onto high-fat diet (HFD), HFD-3% fructose water (HFDF) and ...The commercially available inbred obesity-prone C57BL/6J (B6) and outbred stock ICR mice (3-week old) purchased from a breeder of Beijing were weaned onto high-fat diet (HFD), HFD-3% fructose water (HFDF) and standard rodent chow, respectively. After exposure to the diets for six weeks, HFD and HFDF fed mice were injected intraperitoneally with streptozotocin (STZ, 100mg/kg body weight) and kept on the same diet for next four weeks. Body weight was recorded weekly. Non-fasting blood glucose levels of HFD and HFDF fed mice were measured before and after STZ injections. The body weight of HFD-fed and HFDF-fed B6 mice were significantly lower than that of the control, but body weight of HFD-fed and HFDF-fed ICR mice were significantly higher than that of the control. After injection of STZ, blood glucose levels were above the stardardized criterion (11 mmol/L) for the diabetes mouse model in both HFD and HFDF fed ICR mice, but reverse in B6 mice. The type 2 diabetes model was generated successfully in ICR but not in B6 mice, regardless of whether fructose was supplied. The current results indicated that ICR mouse is still a useful and economical strain for HFD-induced/STZ-treated type 2 diabetes model, and that some variation may occur in the genetic composition among B6 mice bred by different breeders.展开更多
BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2...BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2)MX experiments utilizing high-flux tunable X-rays with energies from 7 to 18 keV,providing a beam spot size of 20μm(horizontal)×10μm(vertical)at the sample point.Certification by the Shanghai Pudong Municipal Health Commission confirmed the capability to perform BSL-2 MX experiments.The beamline is currently equipped with an Eiger X 16 M detector and two newly developed in-house high-precision diffractometers that can be switched to perform conventional or in situ crystal diffraction experiments.An automatic sample changer developed in-house allows fast sample exchange in less than 30 s,supporting high-throughput MX experimentation and rapid crystal screening.Data collection from both the diffractometer and detector was controlled by an in-house developed data collection software(Finback)with a user-friendly interface for convenient operation.This study presents a comprehensive overview of the facilities,experimental methods,and performance characteristics of the BL10U2 beamline.展开更多
文摘The commercially available inbred obesity-prone C57BL/6J (B6) and outbred stock ICR mice (3-week old) purchased from a breeder of Beijing were weaned onto high-fat diet (HFD), HFD-3% fructose water (HFDF) and standard rodent chow, respectively. After exposure to the diets for six weeks, HFD and HFDF fed mice were injected intraperitoneally with streptozotocin (STZ, 100mg/kg body weight) and kept on the same diet for next four weeks. Body weight was recorded weekly. Non-fasting blood glucose levels of HFD and HFDF fed mice were measured before and after STZ injections. The body weight of HFD-fed and HFDF-fed B6 mice were significantly lower than that of the control, but body weight of HFD-fed and HFDF-fed ICR mice were significantly higher than that of the control. After injection of STZ, blood glucose levels were above the stardardized criterion (11 mmol/L) for the diabetes mouse model in both HFD and HFDF fed ICR mice, but reverse in B6 mice. The type 2 diabetes model was generated successfully in ICR but not in B6 mice, regardless of whether fructose was supplied. The current results indicated that ICR mouse is still a useful and economical strain for HFD-induced/STZ-treated type 2 diabetes model, and that some variation may occur in the genetic composition among B6 mice bred by different breeders.
基金supported by the SSRF Phase-II projectNatural Science Foundation of Shanghai(Nos.21ZR1471800 and 23ZR1471200)National Natural Science Foundation of China(No.12005281)。
文摘BL10U2 is an undulator-based macromolecular crystallography(MX)beamline located at the 3.5-GeV Shanghai Synchrotron Radiation Facility.BL10U2 is specifically designed for conducting routine and biosafety level-2(BSL-2)MX experiments utilizing high-flux tunable X-rays with energies from 7 to 18 keV,providing a beam spot size of 20μm(horizontal)×10μm(vertical)at the sample point.Certification by the Shanghai Pudong Municipal Health Commission confirmed the capability to perform BSL-2 MX experiments.The beamline is currently equipped with an Eiger X 16 M detector and two newly developed in-house high-precision diffractometers that can be switched to perform conventional or in situ crystal diffraction experiments.An automatic sample changer developed in-house allows fast sample exchange in less than 30 s,supporting high-throughput MX experimentation and rapid crystal screening.Data collection from both the diffractometer and detector was controlled by an in-house developed data collection software(Finback)with a user-friendly interface for convenient operation.This study presents a comprehensive overview of the facilities,experimental methods,and performance characteristics of the BL10U2 beamline.