期刊文献+
共找到7,107篇文章
< 1 2 250 >
每页显示 20 50 100
Nonlinear Auto-Companding Method for Behavioral Modeling of Switched-Current Circuits
1
作者 王伟 曾璇 +2 位作者 陶俊 苏仰峰 唐璞山 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2002年第12期1254-1261,共8页
A wavelet collocation method with nonlinear auto companding is proposed for behavioral modeling of switched current circuits.The companding function is automatically constructed according to the initial error distri... A wavelet collocation method with nonlinear auto companding is proposed for behavioral modeling of switched current circuits.The companding function is automatically constructed according to the initial error distribution obtained through approximating the input output function of the SI circuit by conventional wavelet collocation method.In practical applications,the proposed method is a general purpose approach,by which both the small signal effect and the large signal effect are modeled in a unified formulation to ease the process of modeling and simulation.Compared with the published modeling approaches,the proposed nonlinear auto companding method works more efficiently not only in controlling the error distribution but also in reducing the modeling errors.To demonstrate the promising features of the proposed method,several SI circuits are employed as examples to be modeled and simulated. 展开更多
关键词 wavelet collocation method behavioral modeling switched current circuits nonlinear auto companding
下载PDF
A Novel Crowbar Impulse Current Circuit for Testing the Switch-Type SPD 被引量:1
2
作者 姚学玲 陈景亮 孙伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期221-226,共6页
A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main dischar... A crowbar impulse current circuit for testing the switch-type surge protective device (SPD) is presented. The crowbar circuit consists of a computer control circuit, a trigger voltage pulse generator, a main discharging switch, and a crowbar pseudospark switch. The active trigger technology was studied in the crowbar impulse current circuit. The circuit monitors the main discharging current and generates a trigger signal at a proper time for the crowbar pseudospark switch operation. The trigger characteristics of the main discharge switch and the crowbar pseu- dospark switch were investigated. By monitoring the preset applied capacitor voltage, the gap distance of the main discharging switch could be adjusted to ensure a discharging delay time less than 2 μs. Equipped with a surface ttashover trigger device made of high relative perimittivity dielectric material BaTiO3 (εr = 3460), the discharge delay time of the crowbar pseudospark switch is less than 85 ns, and the minimum operating voltage is less than 1% of its self-breakdown voltage. With a storage capacitor of 9 μF , an inductor of 18 μH and a crowbar pseudospark switch, a load of 30 mΩ and an applied capacitor voltage of 40 kV, an impulse current waveform of maximum 25 kA was generated with a rise time and time to half peak value of 17.2 μs and 336μs respectively. 展开更多
关键词 crowbar impulse current circuit triggered crowbar pseudospark switch activetrigger technology switch-type surge protective device
下载PDF
Direct Current Circuit Breaker in EAST
3
作者 宋执权 傅鹏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第4期481-484,共4页
This paper introduces the configuration and the operation principles of a high power direct current circuit breaker (DCCB). The commutating current principle of the breaker is described in details with its theory an... This paper introduces the configuration and the operation principles of a high power direct current circuit breaker (DCCB). The commutating current principle of the breaker is described in details with its theory and simulation analysis. The test results presented show that the DCCB meets the requirements for quenching protection. It will be used as the main breaker for quench protection in EAST. 展开更多
关键词 direct current circuit breaker insulator recovery time commutating current contact
下载PDF
Full Graph Methods of Switched Current Circuit Solution
4
作者 Bohumil Brtnik 《Computer Technology and Application》 2011年第6期471-478,共8页
Circuits with switched current are described by an admittance matrix and seeking current transfers then means calculating the ratio of algebraic supplements of this matrix. As there are also graph methods of circuit a... Circuits with switched current are described by an admittance matrix and seeking current transfers then means calculating the ratio of algebraic supplements of this matrix. As there are also graph methods of circuit analysis in addition to algebraic methods, it is clearly possible in theory to carry out an analysis of the whole switched circuit in two-phase switching exclusively by the graph method as well. For this purpose it is possible to plot a Mason graph of a circuit, use transformation graphs to reduce Mason graphs for all the four phases of switching, and then plot a summary graph from the transformed graphs obtained this way. First the author draws nodes and possible branches, obtained by transformation graphs for transfers of EE (even-even) and OO (odd-odd) phases. In the next step, branches obtained by transformation graphs for EO and OE phase are drawn between these nodes, while their resulting transfer is 1 multiplied by z^1/2. This summary graph is extended by two branches from input node and to output node, the extended graph can then be interpreted by the Mason's relation to provide transparent current transfers. Therefore it is not necessary to compose a sum admittance matrix and to express this consequently in numbers, and so it is possible to reach the final result in a graphical way. 展开更多
关键词 Switched current circuits two phases transformation graph Mason's formula current transfer summary MC-graph
下载PDF
CURRENT MODE CIRCUIT SYMBOLIC ANALYSIS WITH MATH-EMATICA
5
作者 滕建辅 李坦 +1 位作者 张泰海 韩志宇 《Transactions of Tianjin University》 EI CAS 1997年第2期19-22,共4页
A practical method of current mode circuit symbolic analysis using Mathematica is proposed. With the powerful symbolic manipulation capacity of Mathematica, current mode circuit symbolic analysis can be significantly ... A practical method of current mode circuit symbolic analysis using Mathematica is proposed. With the powerful symbolic manipulation capacity of Mathematica, current mode circuit symbolic analysis can be significantly simplified. The active devices are modelled by nullors. The examples of current mode filters using CCIIs are presented. 展开更多
关键词 symbolic analysis current mode circuits MATHEMATICA
下载PDF
Influence of optical interference and carrier lifetime on the short circuit current density of organic bulk heterojunction solar cells 被引量:1
6
作者 游海龙 张春福 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第1期349-356,共8页
Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important r... Based on simple analytical equations, short circuit current density (Jsc) of the organic bulk heterojunction solar cells has been calculated. It is found that the optical interference effect plays a very important role in the determination of Jsc; and obvious oscillatory behaviour of Jsc was observed as a function of thickness. At the same time, the influence of the carrier lifetime on Jsc also cannot be neglected. When the carrier lifetime is relatively short, Jsc only increases at the initial stage and then decreases rapidly with the increase of active layer thickness. However, for a relatively long carrier lifetime, the exciton dissociation probability must be considered, and Jsc behaves wave-like with the increase of active layer thickness. The validity of this model is confirmed by the experimental results. 展开更多
关键词 organic solar cells short circuit current density optical interference carrier lifetime
下载PDF
Analysis of each branch current of serial solar cells by using an equivalent circuit model 被引量:4
7
作者 易施光 张万辉 +2 位作者 艾斌 宋经纬 沈辉 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期597-603,共7页
In this paper, based on the equivalent single diode circuit model of the solar cell, an equivalent circuit diagram for two serial solar cells is drawn. Its equations of current and voltage are derived from Kirchhoff'... In this paper, based on the equivalent single diode circuit model of the solar cell, an equivalent circuit diagram for two serial solar cells is drawn. Its equations of current and voltage are derived from Kirchhoff's current and voltage law. First, parameters are obtained from the I-V (current-voltage) curves for typical monocrystalline silicon solar cells (125 mmx 125 mm). Then, by regarding photo-generated current, shunt resistance, serial resistance of the first solar cell, and resistance load as the variables. The properties of shunt currents (Ishl and Ish2), diode currents (/D1 and/]:)2), and load current (IL) for the whole two serial solar cells are numerically analyzed in these four cases for the first time, and the corresponding physical explanations are made. We find that these parameters have different influences on the internal currents of solar cells. Our results will provide a reference for developing higher efficiency solar cell module and contribute to the better understanding of the reason of efficiency loss of solar cell module. 展开更多
关键词 solar cell equivalent circuit current property
下载PDF
DESIGN OF TERNARY CURRENT-MODE CMOS CIRCUITS BASED ON SWITCH-SIGNAL THEORY 被引量:4
8
作者 吴训威 邓小卫 应时彦 《Journal of Electronics(China)》 1993年第3期193-202,共10页
By applying switch-signal theory, the interaction between MOS transmission switch-ing transistor and current signal in current-mode CMOS circuits is analyzed, and the theory oftransmission current-switches which is su... By applying switch-signal theory, the interaction between MOS transmission switch-ing transistor and current signal in current-mode CMOS circuits is analyzed, and the theory oftransmission current-switches which is suitable to current-mode CMOS circuits is proposed. Thecircuits, such as ternary full-adder etc., designed by using this theory have simpler circuit struc-tures and correct logic functions. It is confirmed that this theory is efficient in guiding the logicdesign of current-mode CMOS circuits at switch level. 展开更多
关键词 Switch-signal THEORY THEORY of transmission current-switches Multivalued LOGIC current-MODE CMOS circuit
下载PDF
Vacuum Dielectric Recovery Characteristics of a Novel Current Limiting Circuit Breaker Base on Artificial Current Zero 被引量:20
9
作者 JIANG Zhuangxian ZHUANG Jinwu WANG Chen WU Jin LIU Luhui 《中国电机工程学报》 EI CSCD 北大核心 2012年第13期I0021-I0021,204,共1页
为了保证新型强迫换流型真空直流限流断路器关断短路电流的可靠性,对该型断路器分断过程的真空介质恢复特性进行研究。设计了与断路器关断过程等效的介质恢复试验方案,通过等效试验结果和理论推演公式的拟合,得到了新型强迫换流型限... 为了保证新型强迫换流型真空直流限流断路器关断短路电流的可靠性,对该型断路器分断过程的真空介质恢复特性进行研究。设计了与断路器关断过程等效的介质恢复试验方案,通过等效试验结果和理论推演公式的拟合,得到了新型强迫换流型限流断路器真空灭弧室触头打开过程的动态介质强度恢复规律。研究结果表明:减小燃弧能量、提高触头运动速度可提高真空灭弧室介质的临界击穿电压;综合考虑燃弧时间与燃弧能量及触头开距的关系,随着燃弧时间的增加,真空灭弧室临界击穿电压先减小后增大。所得介质恢复规律可以作为新型断路器优化设计的参考依据。 展开更多
关键词 零电流开关 电路断路器 限流断路器 真空灭弧室 恢复特性 介质 人工 直流电气系统
下载PDF
A Fault Current Limiting Hybrid DC Circuit Breaker 被引量:1
10
作者 Lei Huang Qian Zhang +1 位作者 Wenlei Liu Ruixue Liu 《Energy Engineering》 EI 2022年第2期621-636,共16页
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g... Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB. 展开更多
关键词 Fault current limiting hybrid DC circuit breaker(FCL-HCB) high voltage direct current(HVDC)grid fault current limiting fault current interruption DC circuit breaker
下载PDF
Analysis of Short-circuit Characteristics and Calculation of Steady-state Short-circuit Current for DFIG Wind Turbine 被引量:1
11
作者 Xiong, Xiaofu Ouyang, Jinxin 《电力系统自动化》 EI CSCD 北大核心 2012年第8期115-121,共7页
Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a signifi... Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a significant issue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied to the DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning,protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetric short-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.A new method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions.The time-domain simulations are conducted to verify the accuracy of the proposed method. 展开更多
关键词 双馈风力发电机 短路电流 短路特性 计算 变速恒频 稳态 双馈感应发电机 非对称短路
下载PDF
Design and applicability analysis of independent double acquisition circuit of all-fiber optical current transformer 被引量:2
12
作者 Songlin Gu Liu Han +3 位作者 Dongwei Liu Wenbin Yu Zhihong Xiao Teng Feng 《Global Energy Interconnection》 2019年第6期532-541,共10页
The advantages of the all-fiber optical current transformer include but are not limited to being small in size,having no magnetic saturation,exhibiting high measurement accuracy,and boasting strong electromagnetic int... The advantages of the all-fiber optical current transformer include but are not limited to being small in size,having no magnetic saturation,exhibiting high measurement accuracy,and boasting strong electromagnetic interference resistance.However,the high cost of the all-fiber optical transformer limits its promotion and application in engineering.This paper proposes a design scheme of an independent double acquisition loop for the all-fiber optical current transformer based on the single optical path.Firstly,based on the closed-loop control mode and open-loop control mode,the twochannel sampling signal demand for relay protection,and the independent dual-acquisition loop design scheme of the all-fiber optical current transformer are proposed.Secondly,the reliability and economic feasibility of the scheme are demonstrated by an analysis of system failure and cost.The results show that the scheme can actualize the acquisition function of two independent all-fiber optical current transformer products on a single all-fiber current transformer in an integrated manner,which greatly reduces the cost of the all-fiber optical current transformer in engineering applications. 展开更多
关键词 All-fiber optical current transformer Acquisition circuit RELIABILITY
下载PDF
Effects of current waveform parameters during droplet transfer on spatter in high speed waveform controlled Short-circuiting GMAW 被引量:4
13
作者 吕小青 曹彪 +1 位作者 曾敏 黄增好 《China Welding》 EI CAS 2005年第2期121-124,共4页
Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been... Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been investigated by experimental method. The welding power source used for the research is an inverter with a special current waveform control. It is shown that the spatter decreases at first then increases with each increase of the low current period, current increase rate and the maximum current limit. The test results are provided for welding of 1 mm and 3 mm mild steel at speed of 1.2 m/min. The stable GMA W-S process under high speed welding condition has been achieved by optimizing the parameters. 展开更多
关键词 gas metal arc welding short circuit arc current waveform control high speed welding SPATTER
下载PDF
A Simple Method of Obtaining the z-Domain Transfer Functions of Switched-Current Circuits
14
作者 吴杰 《Chinese Science Bulletin》 SCIE EI CAS 1994年第4期345-347,共3页
Switched-current (SI) is a new analogue sampled data signal processing technique thatfollows the development of switched-capacitor (SC) circuit technique.Recently, this tech-nique has received wide attention. The inte... Switched-current (SI) is a new analogue sampled data signal processing technique thatfollows the development of switched-capacitor (SC) circuit technique.Recently, this tech-nique has received wide attention. The interest is motivated by the facts that SI 展开更多
关键词 snitched current circuit analysis NETWORK function.
原文传递
A SYNTHESIS METHODOLOGY FOR ECL CIRCUITS BASED ON MIXED VOLTAGE-CURRENT REPRESENTATION
15
作者 Wu Xunwei (Department of Electronic Engineering, Zhejiang University, Hangzhou 310028)Qinru Qiu Massoud Pedram (Department of Electrical Engineering-Systems, University of Southern California, USA) 《Journal of Electronics(China)》 1999年第4期359-366,共8页
This paper presents a synthesis methodology for ECL circuits based on a mixed voltage-current signal representation and operation defined on the voltage and current signals. The ideas presented in this paper are then ... This paper presents a synthesis methodology for ECL circuits based on a mixed voltage-current signal representation and operation defined on the voltage and current signals. The ideas presented in this paper are then demonstrated on the design of an BCL 1-bit full adder. The paper concludes by presenting an algebraic system which is suitable for current signal representation and operation on currents. 展开更多
关键词 current signal circuit synthesis ECL ALGEBRAIC system
下载PDF
Research on Parameter Collaborative Configuration of DC Circuit Breaker and DC Fault Current Limiter
16
作者 Lu Qu Zhanqing Yu Zhichang Yuan 《Journal of Power and Energy Engineering》 2019年第9期80-93,共14页
Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC cur... Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system. 展开更多
关键词 DC Power Distribution System FAULT current DC circuit BREAKER DC current LIMITER
下载PDF
DESIGN OF SYMMETRIC TERNARY CURRENT-MODE CMOS CIRCUITS
17
作者 Shen Jizhong Chen Xiexiong Yao maoqun(Dept. Electronic Engineering, Hangzhou University, Hangzhou 310028) 《Journal of Electronics(China)》 1997年第4期336-344,共9页
By applying switch-signal theory, the theory of transmission current-switches based on symmetric ternary logic is proposed, this theory is suitable to design symmetric ternary current-mode CMOS circuits. The symmetric... By applying switch-signal theory, the theory of transmission current-switches based on symmetric ternary logic is proposed, this theory is suitable to design symmetric ternary current-mode CMOS circuits. The symmetric ternary current-mode CMOS circuits designed by using this theory not only have simpler circuit structures and correct logic functions, but also can process bidirectional signals. 展开更多
关键词 SYMMETRIC TERNARY LOGIC current-MODE CMOS circuitS THEORY of transmission current-switches Switch-signal THEORY
下载PDF
Short-circuit Current Characteristics of Wind Generators
18
作者 Seung-Jae LEE Myeon-Song CHOI 《电力系统自动化》 EI CSCD 北大核心 2012年第8期110-114,共5页
To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreemen... To study the effects of wind generators on distribution system protection,the short-circuit current(SCC) characteristics of wind generators is important.Although there are many researches on the issue,a clear agreement has not been reached so far.The SCC characteristics for different wind generators are studied.PSCAD simulation is performed in the same system integrated with different kinds of wind generators,and their results are compared with those reported in IEEE papers.The detection possibility by overcurrent relay(OCR)is discussed based on the simulation results. 展开更多
关键词 风力发电机组 短路电流 电流特性 配电系统 PSCAD 过流继电器 IEEE 通过检测
下载PDF
Study on Effect of UHV Power Grid Construction Schemes on Short Circuit Current
19
作者 Zaihua Li Feng Gao +3 位作者 Qing Wang Shuang Zhang Hongmei Luo Jian Liang 《Journal of Power and Energy Engineering》 2015年第4期200-205,共6页
The commissioning of Southern Hami-Zhengzhou ±800 kV UHVDC transmission project has important significance to heighten operation reliability, transfer capability and supply electric ability of Henan power grid. H... The commissioning of Southern Hami-Zhengzhou ±800 kV UHVDC transmission project has important significance to heighten operation reliability, transfer capability and supply electric ability of Henan power grid. However, short circuit currents of 500 kV buses in the Center of Henan are almost close to the operation upper limitation. In order to decrease the short circuit currents effectively, it’s necessary to strengthen the network structure of Center of Henan power grid and calculate short circuit currents. Two schemes of strengthening the network structure of Center of Henan power grid are studied. The calculated values of short circuit currents of some important 500 kV buses in the two schemes are still bigger than excepted. According to the latest Plan of State Grid, Yubei UHV substation and Zhumadian UHV substation located in Henan power grid. The calculated values of short circuit currents of some important 500 kV buses with the commissioning of Yubei UHV and Zhumadian UHV are qualified. So, reasonable network structure with UHV is suitable to heighten transfer capability and supply electric ability of Henan power grid. 展开更多
关键词 UHV UHVDC Construction Scheme SHORT circuit current
下载PDF
Study on Short Circuit Current Calculation of Power System with UHVDC and New Energy Source
20
作者 Zaihua Li Huan Yan +1 位作者 Yunting Song Jincheng Guo 《Energy and Power Engineering》 2017年第4期625-634,共10页
With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the sh... With the development of power system, the level of short circuit current will increase accordingly. In general, the influence of the HVDC system and the new energy source is not considered in the calculation of the short circuit current. For the power grid that short circuit current level closes to the interrupting capacity of circuit breaker, it’s necessary to fully consider all kinds of influence factors, careful checking, so as to obtain more accurate calculation results of short circuit current. In 2018, two ±800 kV high-power Ultra High Voltage Direct Current (UHVDC) transmission projects will be connected with Shaanxi power grid, accompanied by a lot of concomitant fossil-fuel generating plants as power resource, and also a large number of new energy source, includes wind power generation and photovoltaic power generation. Around one of the UHVDC converter stations, short circuit current may exceed the withstand limit of some certain circuit breakers. In order to get more accurate short circuit current calculation results, three measures are used: 1) contrastive calculation and analysis by algorithm based on schemes and algorithm based on power flow;2) analysis the influence of UHVDC by electromagnetic transient and electromechanical transient hybrid simulation;3) considered a detailed model of Doubly Fed Induction Generator (DFIG) with low voltage ride through characteristics. The calculation results shows that: in the typical operation mode of Shaanxi power grid of 2018, the original calculation results by conventional calculation method are coincident with the results by considering the influence of algorithms, UHVDC and DFIG in large, in which: the results of the algorithm based on power flow are smaller than that of the algorithm based on schemes about 2 - 8 kA;the steady values of the short circuit current provided by UHVDC converterstation (includes rectifiers and smoothing capacitors) are about 0 - 3 kA;the steady values of the short circuit current provided by DFIG are about 0 - 5 kA. The calculation results can provide reference for the selection of the circuit breaker, and it can be verified by fault recording data in the future. 展开更多
关键词 SHORT circuit current UHVDC New Energy SOURCE Hybrid Simulation
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部