In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is sing...In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is single or two-current sensor fault occurs,based on the proposed method the missing current information can be reconstructed by using direct current(DC)bus current sensor and the three-phase current can be updated in time within any two adjacent sampling periods,so as to ensure stability of the closed-loop system.And then the switchover and fault tolerant control of fault current sensor would be accomplished by fault diagnosis method based on adaptive threshold judgment.For the reconstructed signal error caused by the modulation method and the main control target of electric pitch system,a variable universe fuzzy control method is used in the speed loop,which can improve the anti-disturbance ability to load variation,and the robustness of fault tolerance system.The results show that the fault tolerant control method makes the variable pitch control system still has ideal control characteristics in case of sensor failure although part of the system performance is lost,thus the correctness of the proposed method is verified.展开更多
A novel software implementation for current polarity detection and current compensation is presented. For a three-phase zero-voltage soft-switching (ZVS) PWM converter based on phase and amplitude control (PAC), w...A novel software implementation for current polarity detection and current compensation is presented. For a three-phase zero-voltage soft-switching (ZVS) PWM converter based on phase and amplitude control (PAC), when saw-tooth carriers with alternate positive and negative slopes are adopted, the positive or negative slopes are chosen according to the phase current polarity. Since polarity reversal causes current distortion, current at the instant of reversal should be compensated for. Based on the characteristic of unity power factor converter in rectification and regeneration modes, a software implementation for current polarity detection is proposed. Distortion of current zero-crossing caused by using saw-tooth carriers with alternate positive and negative slopes is analyzed, and the relevant compensation method is proposed. Experimental study with a 1.5 kW device shows that phase current has a small harmonic content and power factor is high both in rectification and regeneration modes.展开更多
Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy...Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy demand means that the interest for the integration of renewable energy sources in the existing power system is growing, but such integration poses challenges to the operating stability. Power converters play a major role in the evolution of power system towards SmartGrids, by regulating as virtual synchronous generators. The concept of virtual synchronous generators requires an energy storage system with power converters to emulate virtual inertia similar to the dynamics of traditional synchronous generators. In this paper, a dynamic droop control for the estimation of fundamental reference sources is implemented in the control loop of the converter, including active and reactive power components acting as a mechanical input to the virtual synchronous generator and the virtual excitation controller. An inertia coefficient and a droop coefficient are implemented in the control loop. The proposed controller uses a current synchronous detection scheme to emulate a virtual inertia from the virtual synchronous generators. In this study, a wave energy converter as the power source is used and a power management of virtual synchronous generators to control the frequency deviation and the terminal voltage is implemented. The dynamic control scheme based on a current synchronous detection scheme is presented in detail with a power management control. Finally, we carried out numerical simulations and verified the scheme through the experimental results in a microgrid structure.展开更多
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren...The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.展开更多
An integrated single-inductor dual-output (SIDO) switching DC-DC converter is presented. The outputs are specified with 1.2 V/400 mA and 1.8 V/200 mA. A decoupling small signal model is proposed to analyze the multi...An integrated single-inductor dual-output (SIDO) switching DC-DC converter is presented. The outputs are specified with 1.2 V/400 mA and 1.8 V/200 mA. A decoupling small signal model is proposed to analyze the multi-loop system and to design the on-chip compensators. An average current control mode is introduced with lossless, continuous current detection. The converter has been fabricated in a 0.25μm 2P4M CMOS process. The power efficiency is 86% at a total output power of 840 mW while the output ripples are about 40 mV at an oscillator frequency of 600 kHz.展开更多
基金Natural Science Foundation of Gansu Province(Joint)Project(No.213244)Natural Science Foundation of Gansu Province(No.145RJZA136)Youth Science Foundation of Lanzhou Jiaotong University(No.2013040)
文摘In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is single or two-current sensor fault occurs,based on the proposed method the missing current information can be reconstructed by using direct current(DC)bus current sensor and the three-phase current can be updated in time within any two adjacent sampling periods,so as to ensure stability of the closed-loop system.And then the switchover and fault tolerant control of fault current sensor would be accomplished by fault diagnosis method based on adaptive threshold judgment.For the reconstructed signal error caused by the modulation method and the main control target of electric pitch system,a variable universe fuzzy control method is used in the speed loop,which can improve the anti-disturbance ability to load variation,and the robustness of fault tolerance system.The results show that the fault tolerant control method makes the variable pitch control system still has ideal control characteristics in case of sensor failure although part of the system performance is lost,thus the correctness of the proposed method is verified.
基金Project supported by Shanghai Leading Academic DisciplineProject (Grant No .T0103) ,and Shanghai Post Doctoral Scienti-fic Research (Grant No .05R214122)
文摘A novel software implementation for current polarity detection and current compensation is presented. For a three-phase zero-voltage soft-switching (ZVS) PWM converter based on phase and amplitude control (PAC), when saw-tooth carriers with alternate positive and negative slopes are adopted, the positive or negative slopes are chosen according to the phase current polarity. Since polarity reversal causes current distortion, current at the instant of reversal should be compensated for. Based on the characteristic of unity power factor converter in rectification and regeneration modes, a software implementation for current polarity detection is proposed. Distortion of current zero-crossing caused by using saw-tooth carriers with alternate positive and negative slopes is analyzed, and the relevant compensation method is proposed. Experimental study with a 1.5 kW device shows that phase current has a small harmonic content and power factor is high both in rectification and regeneration modes.
基金Swedish Research Council(VR)STandUP for Energy,MaRINET2 and Erasmus Mundus(EMINTE)Ph.D.Scholarship for the support of the work
文摘Renewable energy sources, such as photovoltaic wind turbines, and wave power converters, use power converters to connect to the grid which causes a loss in rotational inertia. The attempt to meet the increasing energy demand means that the interest for the integration of renewable energy sources in the existing power system is growing, but such integration poses challenges to the operating stability. Power converters play a major role in the evolution of power system towards SmartGrids, by regulating as virtual synchronous generators. The concept of virtual synchronous generators requires an energy storage system with power converters to emulate virtual inertia similar to the dynamics of traditional synchronous generators. In this paper, a dynamic droop control for the estimation of fundamental reference sources is implemented in the control loop of the converter, including active and reactive power components acting as a mechanical input to the virtual synchronous generator and the virtual excitation controller. An inertia coefficient and a droop coefficient are implemented in the control loop. The proposed controller uses a current synchronous detection scheme to emulate a virtual inertia from the virtual synchronous generators. In this study, a wave energy converter as the power source is used and a power management of virtual synchronous generators to control the frequency deviation and the terminal voltage is implemented. The dynamic control scheme based on a current synchronous detection scheme is presented in detail with a power management control. Finally, we carried out numerical simulations and verified the scheme through the experimental results in a microgrid structure.
基金The financial support from the National Natural Science Foundation of China (No. 51107143)
文摘The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.
文摘An integrated single-inductor dual-output (SIDO) switching DC-DC converter is presented. The outputs are specified with 1.2 V/400 mA and 1.8 V/200 mA. A decoupling small signal model is proposed to analyze the multi-loop system and to design the on-chip compensators. An average current control mode is introduced with lossless, continuous current detection. The converter has been fabricated in a 0.25μm 2P4M CMOS process. The power efficiency is 86% at a total output power of 840 mW while the output ripples are about 40 mV at an oscillator frequency of 600 kHz.