The design of iterative learning controller(ILC) requires to store the system input, output or control parameters of previous trials for generating the input of the current trial. In order to apply the iterative learn...The design of iterative learning controller(ILC) requires to store the system input, output or control parameters of previous trials for generating the input of the current trial. In order to apply the iterative learning controller for a real application and reduce the memory size for implementation, a current error based sampled-data proportional-derivative(PD) type iterative learning controller is proposed for control systems with initial resetting error, input disturbance and output measurement noise in this paper.The proposed iterative learning controller is simple and effective. The first contribution in this paper is to prove the learning error convergence via a rigorous technical analysis. It is shown that the learning error will converge to a residual set if a forgetting factor is introduced in the controller. All the theoretical results are also shown by computer simulations. The second main contribution is to realize the iterative learning controller by a digital circuit using a field programmable gate array(FPGA) chip applied to repetitive position tracking control of direct current(DC) motors. The feasibility and effectiveness of the proposed current error based sampleddata iterative learning controller are demonstrated by the experiment results. Finally, the relationship between learning performance and design parameters are also discussed extensively.展开更多
Magnetic sensor arrays are proposed to measure electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. Simulation techniques ar...Magnetic sensor arrays are proposed to measure electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. Simulation techniques are necessary to study the factors influencing the accuracy of current measurement. This paper presents a simulation method to estimate the impact of sensing area and position of sensors on the accuracy of current measurement. Several error models are built up to support computer-aided design of magnetic sensor arrays.展开更多
For actively modulated In-line Sagnac interferential all optic fiber current transformers (AOFCTs), the accuracies are directly affected by the amplitude of the modulation signal. In order to deeply undertand the func...For actively modulated In-line Sagnac interferential all optic fiber current transformers (AOFCTs), the accuracies are directly affected by the amplitude of the modulation signal. In order to deeply undertand the function of the modulator, a theoretical model of modulation effect to AOFCTs is built up in this paper. The effect of the amplitude of the modulation signal to the output intensity of AOFCTs is theoretically formulated and numerical calculated. The results show that the modulation voltage variation could affect the output accuracies significantly. This might be some references on the investigation for practical applications of AOFCTs.展开更多
提出了在等电位工作状态下校准多元感应分流器(multiple inductive current divider,MICD)的1种方法。在校准装置中加入由跟随器和电阻组成的I/V变换器,以使MICD各支路间的电流比例与其工作状态保持一致;用参考电流互感器(CT)提供独立...提出了在等电位工作状态下校准多元感应分流器(multiple inductive current divider,MICD)的1种方法。在校准装置中加入由跟随器和电阻组成的I/V变换器,以使MICD各支路间的电流比例与其工作状态保持一致;用参考电流互感器(CT)提供独立的参考电流,以避免影响支路电流的比例关系。在20、55、400 Hz及1 kHz下对11支路MICD校准所得10:1电流比例的比值差合成标准不确定度优于0.2μA/A,相位差合成标准不确定度优于1.5μrad。展开更多
基金supported by National Science Council,Taiwan,China(No.NSC102-2221-E-211-011)National Nature Science Foundation of China(No.61374102)
文摘The design of iterative learning controller(ILC) requires to store the system input, output or control parameters of previous trials for generating the input of the current trial. In order to apply the iterative learning controller for a real application and reduce the memory size for implementation, a current error based sampled-data proportional-derivative(PD) type iterative learning controller is proposed for control systems with initial resetting error, input disturbance and output measurement noise in this paper.The proposed iterative learning controller is simple and effective. The first contribution in this paper is to prove the learning error convergence via a rigorous technical analysis. It is shown that the learning error will converge to a residual set if a forgetting factor is introduced in the controller. All the theoretical results are also shown by computer simulations. The second main contribution is to realize the iterative learning controller by a digital circuit using a field programmable gate array(FPGA) chip applied to repetitive position tracking control of direct current(DC) motors. The feasibility and effectiveness of the proposed current error based sampleddata iterative learning controller are demonstrated by the experiment results. Finally, the relationship between learning performance and design parameters are also discussed extensively.
基金Supported by National High-Tech Industry Development Project (1883)
文摘Magnetic sensor arrays are proposed to measure electric current in a non-contact way. In order to achieve higher accuracy, signal processing techniques for magnetic sensor arrays are utilized. Simulation techniques are necessary to study the factors influencing the accuracy of current measurement. This paper presents a simulation method to estimate the impact of sensing area and position of sensors on the accuracy of current measurement. Several error models are built up to support computer-aided design of magnetic sensor arrays.
文摘For actively modulated In-line Sagnac interferential all optic fiber current transformers (AOFCTs), the accuracies are directly affected by the amplitude of the modulation signal. In order to deeply undertand the function of the modulator, a theoretical model of modulation effect to AOFCTs is built up in this paper. The effect of the amplitude of the modulation signal to the output intensity of AOFCTs is theoretically formulated and numerical calculated. The results show that the modulation voltage variation could affect the output accuracies significantly. This might be some references on the investigation for practical applications of AOFCTs.