AIM: To evaluate the efficacy and toxicity of stereotactic body radiotherapy using Cyber Knife for locally advanced unresectable and metastatic pancreatic cancer.METHODS: From June 2010 to May 2014,25 patients with lo...AIM: To evaluate the efficacy and toxicity of stereotactic body radiotherapy using Cyber Knife for locally advanced unresectable and metastatic pancreatic cancer.METHODS: From June 2010 to May 2014,25 patients with locally advanced unresectable and metastatic pancreatic cancer underwent stereotactic body radiotherapy.Nine patients presented with unresectable locally advanced disease and 16 had metastatic disease.Primary end-points of this study were overall survival,relief of abdominal pain,and toxicity.RESULTS: Fourteen patients were treated with a total dose of 30-36 Gy in three fractions and the remainder with 40-48 Gy in four fractions.Median follow-up was 11 mo(range: 2-25 mo).The median survival duration calculated from the time of stereotactic body radiotherapy for the entire group,the locally advanced group,and the metastatic group was 9.0 mo,13.5 mo,and 8.5 mo,respectively.Overall survival was 37% and 18% at one and two years,respectively.Abdominal pain relief was achieved within 2 wk of completing radiotherapy in the patients who received successful palliation(13 of 20 patients had significant pain).Five patients(20%) had grade 1 nausea,and one(4%) had grade 2 nausea.No acute grade 3+ toxicity was seen.CONCLUSION: Stereotactic body radiotherapy using the Cyber Knife system is a promising,noninvasive,palliative treatment with acceptable toxicity for locally advanced unresectable and metastatic pancreatic cancer.展开更多
AIM: To assess how the application of different types of markers affects the tracking accuracy of Cyber Knife's.METHODS: Fifteen patients were recruited and subjected to the ultrasound-guided placement of markers....AIM: To assess how the application of different types of markers affects the tracking accuracy of Cyber Knife's.METHODS: Fifteen patients were recruited and subjected to the ultrasound-guided placement of markers. Two different type of needles 25 gauge(G) and 17 G containing two different fiducial marker, gold notched flexible anchor wire 0.28 mm × 10 mm(25 G needle) and gold cylindrical grain 1 mm × 4 mm(17 G), were used. Seven days after the procedure, a Cyber Knife planning computed tomography(CT) for the simulation of radiation treatment was performed on all patients.A binary CT score was assigned to the fiducial markers visualization. Also, the CT number was calculated for each fiducial and the values compared with a specific threshold.RESULTS: For each patient from 1 to 5, intra-hepatic markers were placed(one in 2 patients, three in 8 patients, four in 3 patients, and five in 2 patients). A total of 48 needles were used(thirty-two 17 G and sixteen 25 G) and 48 gold markers were placed(32 Grain shaped markers and 16 Gold Anchor). The result showed that the CT visualization of the grain markers was better than the anchor markers(P = 5 × 10^(-9)). Furthermore, the grain markers were shown to present minor late complications(P = 3 × 10^(-6)), and the best CT threshold number(P = 0.0005). CONCLUSION: The study revealed that the Gold Anchor fiducial marker is correlated with a greater number of late minor complications and low visualization by the CT.展开更多
文摘AIM: To evaluate the efficacy and toxicity of stereotactic body radiotherapy using Cyber Knife for locally advanced unresectable and metastatic pancreatic cancer.METHODS: From June 2010 to May 2014,25 patients with locally advanced unresectable and metastatic pancreatic cancer underwent stereotactic body radiotherapy.Nine patients presented with unresectable locally advanced disease and 16 had metastatic disease.Primary end-points of this study were overall survival,relief of abdominal pain,and toxicity.RESULTS: Fourteen patients were treated with a total dose of 30-36 Gy in three fractions and the remainder with 40-48 Gy in four fractions.Median follow-up was 11 mo(range: 2-25 mo).The median survival duration calculated from the time of stereotactic body radiotherapy for the entire group,the locally advanced group,and the metastatic group was 9.0 mo,13.5 mo,and 8.5 mo,respectively.Overall survival was 37% and 18% at one and two years,respectively.Abdominal pain relief was achieved within 2 wk of completing radiotherapy in the patients who received successful palliation(13 of 20 patients had significant pain).Five patients(20%) had grade 1 nausea,and one(4%) had grade 2 nausea.No acute grade 3+ toxicity was seen.CONCLUSION: Stereotactic body radiotherapy using the Cyber Knife system is a promising,noninvasive,palliative treatment with acceptable toxicity for locally advanced unresectable and metastatic pancreatic cancer.
文摘AIM: To assess how the application of different types of markers affects the tracking accuracy of Cyber Knife's.METHODS: Fifteen patients were recruited and subjected to the ultrasound-guided placement of markers. Two different type of needles 25 gauge(G) and 17 G containing two different fiducial marker, gold notched flexible anchor wire 0.28 mm × 10 mm(25 G needle) and gold cylindrical grain 1 mm × 4 mm(17 G), were used. Seven days after the procedure, a Cyber Knife planning computed tomography(CT) for the simulation of radiation treatment was performed on all patients.A binary CT score was assigned to the fiducial markers visualization. Also, the CT number was calculated for each fiducial and the values compared with a specific threshold.RESULTS: For each patient from 1 to 5, intra-hepatic markers were placed(one in 2 patients, three in 8 patients, four in 3 patients, and five in 2 patients). A total of 48 needles were used(thirty-two 17 G and sixteen 25 G) and 48 gold markers were placed(32 Grain shaped markers and 16 Gold Anchor). The result showed that the CT visualization of the grain markers was better than the anchor markers(P = 5 × 10^(-9)). Furthermore, the grain markers were shown to present minor late complications(P = 3 × 10^(-6)), and the best CT threshold number(P = 0.0005). CONCLUSION: The study revealed that the Gold Anchor fiducial marker is correlated with a greater number of late minor complications and low visualization by the CT.