A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which...A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion.展开更多
A space-resolving transmission grating spectrometer is established on the "Shenguang-III" prototype laser facility and an iterative procedure for unfolding the X-ray spectrum with spatial resolution is described. Th...A space-resolving transmission grating spectrometer is established on the "Shenguang-III" prototype laser facility and an iterative procedure for unfolding the X-ray spectrum with spatial resolution is described. The diagnostics is applied to measure the X-ray spectrum from laser-entered gold target and the typical space-resolved spectrum is provided. The relative standard uncertainty of the X-ray spectrum from the laser-generated plasma is also determined.展开更多
Optical spectrometer of the Guillermo Haro astrophysical observatory (Mexico) realizes investigations in the visible and near-infrared range 350 - 800 nm and exploits mechanically removable traditional static diffract...Optical spectrometer of the Guillermo Haro astrophysical observatory (Mexico) realizes investigations in the visible and near-infrared range 350 - 800 nm and exploits mechanically removable traditional static diffraction gratings as dispersive elements. There is a set of the static gratings with slit-densities 150 - 600 lines/mm and optical apertures 9 cm × 9 cm that provide the first order spectral resolution from 0.8 to 3.2 A/pixel, respectively. However, the needed mechanical manipulations, namely, replacing the static diffraction gratings with various resolutions and following recalibration of spectrometer within studying even the same object are practically inconvenient and lead to wasting rather expensive observation time. We suggest exploiting an acousto-optical cell, i.e. the dynamic diffraction grating tunable electronically, as dispersive element in that spectrometer. Involving the acousto-optical technique, which can potentially provide electronic control over the spectral resolution and the range of observations, leads to eliminating the abovementioned demerits and improving the efficiency of analysis.展开更多
In view of the difficulties in traditional long-wave infrared imaging spectrometer which is hard to realize a high signal-to-noise ratio and miniaturization as well under the weak remote sensing signal,Offner convex g...In view of the difficulties in traditional long-wave infrared imaging spectrometer which is hard to realize a high signal-to-noise ratio and miniaturization as well under the weak remote sensing signal,Offner convex grating spectrometer and Dyson concave grating spectrometer,both having concentric structure,are designed and analyzed in the band of 8-12 μm. The diffraction angle expressions of the two spectrometers are obtained and the diffraction characteristics are acquired. Both of the spectrometers are designed in Zemax environment under different F-numbers and different grating constants with the same slit,spatial resolution,spectral resolution and detector. The results show that Dyson grating spectrometer possesses the advantages of higher throughput and smaller volume, and Offner grating spectrometer possesses the advantage of more accessible material and the absence of chromatic aberration. The differences between Dyson form and Offner form show that the former is a better choice in the long-wave infrared imaging spectrometer.展开更多
A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate co...A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments.展开更多
基金supported by National Natural Science Foundation of China(Nos.11405158 and 11435011)Development Foundation of China Academy of Engineering Physics(Nos.2014B0102011 and 2014B0102012)
文摘A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion.
基金supported by the National High Technology Program 863 of China
文摘A space-resolving transmission grating spectrometer is established on the "Shenguang-III" prototype laser facility and an iterative procedure for unfolding the X-ray spectrum with spatial resolution is described. The diagnostics is applied to measure the X-ray spectrum from laser-entered gold target and the typical space-resolved spectrum is provided. The relative standard uncertainty of the X-ray spectrum from the laser-generated plasma is also determined.
文摘Optical spectrometer of the Guillermo Haro astrophysical observatory (Mexico) realizes investigations in the visible and near-infrared range 350 - 800 nm and exploits mechanically removable traditional static diffraction gratings as dispersive elements. There is a set of the static gratings with slit-densities 150 - 600 lines/mm and optical apertures 9 cm × 9 cm that provide the first order spectral resolution from 0.8 to 3.2 A/pixel, respectively. However, the needed mechanical manipulations, namely, replacing the static diffraction gratings with various resolutions and following recalibration of spectrometer within studying even the same object are practically inconvenient and lead to wasting rather expensive observation time. We suggest exploiting an acousto-optical cell, i.e. the dynamic diffraction grating tunable electronically, as dispersive element in that spectrometer. Involving the acousto-optical technique, which can potentially provide electronic control over the spectral resolution and the range of observations, leads to eliminating the abovementioned demerits and improving the efficiency of analysis.
基金Sponsored by the National High Technology Research and Development Program of China(863 Program)(Grant No.2013AA03A116)
文摘In view of the difficulties in traditional long-wave infrared imaging spectrometer which is hard to realize a high signal-to-noise ratio and miniaturization as well under the weak remote sensing signal,Offner convex grating spectrometer and Dyson concave grating spectrometer,both having concentric structure,are designed and analyzed in the band of 8-12 μm. The diffraction angle expressions of the two spectrometers are obtained and the diffraction characteristics are acquired. Both of the spectrometers are designed in Zemax environment under different F-numbers and different grating constants with the same slit,spatial resolution,spectral resolution and detector. The results show that Dyson grating spectrometer possesses the advantages of higher throughput and smaller volume, and Offner grating spectrometer possesses the advantage of more accessible material and the absence of chromatic aberration. The differences between Dyson form and Offner form show that the former is a better choice in the long-wave infrared imaging spectrometer.
基金supported by the National Natural Science Foundation of China(Grant Nos.11221002,11274152,and 11074297)
文摘A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments.