When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop thr...When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop through the near-electrode sheath is an important means to build up the arc voltage, which directly determines the current-limiting performance of the DCCB. A numerical model to describe the near-electrode sheath formation process can provide insight into the physical mechanism of the arc formation, and thus provide a method for arc energy regulation. In this work, we establish a two-dimensional axisymmetric time-varying model of a medium-voltage DCCB arc when interrupted by high current based on a fluid-chemical model involving 16 kinds of species and 46 collision reactions. The transient distributions of electron number density, positive and negative ion number density, net space charge density, axial electric field, axial potential between electrodes, and near-cathode sheath are obtained from the numerical model. The computational results show that the electron density in the arc column increases, then decreases, and then stabilizes during the near-cathode sheath formation process, and the arc column's diameter gradually becomes wider. The 11.14 V–12.33 V drops along the17 μm space charge layer away from the cathode(65.5 k V/m–72.5 k V/m) when the current varies from 20 k A–80 k A.The homogeneous external magnetic field has little effect on the distribution of particles in the near-cathode sheath core,but the electron number density at the near-cathode sheath periphery can increase as the magnetic field increases and the homogeneous external magnetic field will lead to arc diffusion. The validity of the numerical model can be proven by comparison with the experiment.展开更多
This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the hig...This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the high voltage circuit breaker during its close-open operating cycle. Using real time measurements of currents/voltages and angles during the close-opening cycle of high voltage generator circuit breaker and the impact of the dc component of current in context of interrupting large magnitude of current from the circuit breaker. In addition, the paper describes a study case model and the results of simulations performed using the software EMTP-ATP of an actual incident that occurred during the inadvertent synchronization of a large 339 MW, 24 kV generator to the grid.展开更多
Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application...Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker.展开更多
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g...Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.展开更多
Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC cur...Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system.展开更多
如何对直流故障电流进行有效抑制是实现柔性直流电网大规模发展的关键。为此,研究模块化多电平变换器(modular multilevel converter,MMC)的控制方法,提出一种针对半桥型MMC的两段式限流保护策略,通过减少子模块的投入数目来降低换流站...如何对直流故障电流进行有效抑制是实现柔性直流电网大规模发展的关键。为此,研究模块化多电平变换器(modular multilevel converter,MMC)的控制方法,提出一种针对半桥型MMC的两段式限流保护策略,通过减少子模块的投入数目来降低换流站直流出口电压,达到限制短路电流的目的。首先,介绍MMC的拓扑结构及基于MMC的高压直流输电(MMC based high voltage direct current,MMC-HVDC)系统控制策略;其次,分析两段式限流保护策略的原理与直流故障电流特性,介绍MMC-HVDC系统的直流故障保护策略;最后,通过双端MMC-HVDC系统仿真实验,对所提限流保护策略的有效性进行验证。仿真结果表明,两段式限流保护策略可以有效降低断路器开断电流和吸收能量,节约成本。展开更多
This work is based on a direct current(DC)natural current commutation topology,which uses load-carrying branch contacts carrying rated current and multiple sets of series arcing branch contacts in parallel to achieve ...This work is based on a direct current(DC)natural current commutation topology,which uses load-carrying branch contacts carrying rated current and multiple sets of series arcing branch contacts in parallel to achieve circuit breaking.The proposed topology can meet the new requirements of higher voltage DC switches in aviation,aerospace,energy and other fields.First,a magneto-hydrodynamic arc model is built using COMSOL Multiphysics,and the different arc breaking characteristics of the arcing branch contacts in different gas environments are simulated.Then,a voltage uniformity coefficient is used to measure the voltage sharing effect in the process of dynamic interruption.In order to solve the dispersion of arcing contact action,a structural control method is adopted to improve the voltage uniformity coefficient.The uniform voltage distribution can improve the breaking capacity and electrical life of the series connection structure.展开更多
The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power thr...The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.展开更多
Solid-state circuit breakers(SSCBs)are critical components in the protection of medium-voltage DC distribution networks to facilitate arc-free,fast and reliable isolation of DC faults.However,limited by the capacity o...Solid-state circuit breakers(SSCBs)are critical components in the protection of medium-voltage DC distribution networks to facilitate arc-free,fast and reliable isolation of DC faults.However,limited by the capacity of a single semiconductor device,using semi-conductor-based SSCBs at high voltage is challenging.This study presents the details of a 1.5 kV,63 A medi-um-voltage SSCB,composed primarily of a solid-state switch based on three cascaded normally-on silicon car-bide(SiC)junction field-effect transistors(JFETs)and a low-cost programmable gate drive circuit.Dynamic and static voltage sharing among the cascaded SiC JFETs of the SSCB during fault isolation is realized using the pro-posed gate drive circuit.The selection conditions for the key parameters of the SSCB gate driver are also analyzed.Additionally,an improved pulse-width modulation cur-rent-limiting protection solution is proposed to identify the permanent overcurrent and transient inrush current associated with capacitive load startup in a DC distribu-tion network.Using the developed SSCB prototype and the fault test system,experimental results are obtained to validate the fault response performance of the SSCB.Index Terms—Solid-state circuit breaker,DC distribu-tion network,SiC JFET,voltage balancing,inrush current.展开更多
提出了一种由集成直流断路器的模块化多电平换流器(modular multilevel converter integrated with DC circuit breaker,IDCB-MMC)和晶闸管换流器组成的混合直流输电系统。在发生直流短路故障时,通过换流器与直流断路器在控制上的配合,I...提出了一种由集成直流断路器的模块化多电平换流器(modular multilevel converter integrated with DC circuit breaker,IDCB-MMC)和晶闸管换流器组成的混合直流输电系统。在发生直流短路故障时,通过换流器与直流断路器在控制上的配合,IDCB-MMC可以将故障电流的能量转移到并联于直流母线间的能量吸收支路中,从而可以避免使用成本高且占地大的电力电子开关支路。晶闸管换流器则可以通过快速转换到逆变状态实现直流故障电流的清除。对1 000 MW/±320 kV的双端混合直流输电系统中的一极进行了仿真研究。仿真结果表明IDCB-MMC可以有效清除直流短路故障电流,实现系统的自动恢复,结果也验证了由IDCB-MMC与晶闸管换流器组成的混合直流输电系统的可行性。展开更多
This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodyna...This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodynamic (MHD) model of air arc plasma in the contact system of a DCCB is developed, based on commercial software FLUENT. Coupled electromagnetic and gas dynamic interactions are considered as usual, and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc root. The distributions of pressure, temperature, gas flow and current density of arc plasma in arc region are calculated. The simulation results indicate that the pressure distribution related to the contact system has a strong effect on the arc commutation process, arising from the change of electrical conductivity in the arc root region. In DCCB contact system, the pressure of arc root region will be concentrated and higher if the space above the moving contact is enclosed, which is not good for arc root commutation. However, when the region is opened, the pressure distribution would be lower and more evenly, which is favorable for the arc root commutation.展开更多
Environmental issues associated with the aviation industry are getting more attention as air traffic increases.Stringent standards are imposed for fuel consumption and pollution emissions for next-generation aircraft....Environmental issues associated with the aviation industry are getting more attention as air traffic increases.Stringent standards are imposed for fuel consumption and pollution emissions for next-generation aircraft.Superconducting electrical propulsion aircraft(SEPA)have been seen as an efficient way to achieve this goal.High-temperature superconducting(HTS)devices are extensively used in the power system to supply enormous energy.Power is distributed to the different loads via a DC distribution network.However,it will generate an inrush current over ten times higher than the rated current in short-circuit state,which is very harmful to the system.Therefore,it is essential to adopt an appropriate protection scheme.This paper discusses one protection scheme that combines DC vacuum circuit breakers(DC VCB)and resistive superconducting current limiters(RSFCL)for superconducting aircraft applications.Considering problems of cost and loss,the auxiliary capacitor is pre-charged by system voltage,and mechanical elements extinguish the arc.Furthermore,combined with RSFCL,the interrupting environment is fully improved.RSFCL limits fault current,and then the VCB breaks this limited current based on creating an artificial current zero(ACZ).The prospective rated power is 8MW,rated voltage and current are 4 kV and 1 kA,respectively.In this paper,we discuss and simulate switching devices that protect SEPA.The interrupting performance of the circuit breaker is analysed in the DC short-circuit fault that occurs on the transmission line.Finally,the residual energy consumption of different situations is calculated.A comparison is made between using RSFCL with metal oxide varistor(MOV)and just using MOV.The scheme with RSFCL shows a significant advantage in energy consumption.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No.51977132)Key Special Science and Technology Project of Liaoning Province (Grant No.2020JH1/10100012)General Program of the Education Department of Liaoning Province (Grant No.LJKZ0126)。
文摘When the contacts of a medium-voltage DC air circuit breaker(DCCB) are separated, the energy distribution of the arc is determined by the formation process of the near-electrode sheath. Therefore, the voltage drop through the near-electrode sheath is an important means to build up the arc voltage, which directly determines the current-limiting performance of the DCCB. A numerical model to describe the near-electrode sheath formation process can provide insight into the physical mechanism of the arc formation, and thus provide a method for arc energy regulation. In this work, we establish a two-dimensional axisymmetric time-varying model of a medium-voltage DCCB arc when interrupted by high current based on a fluid-chemical model involving 16 kinds of species and 46 collision reactions. The transient distributions of electron number density, positive and negative ion number density, net space charge density, axial electric field, axial potential between electrodes, and near-cathode sheath are obtained from the numerical model. The computational results show that the electron density in the arc column increases, then decreases, and then stabilizes during the near-cathode sheath formation process, and the arc column's diameter gradually becomes wider. The 11.14 V–12.33 V drops along the17 μm space charge layer away from the cathode(65.5 k V/m–72.5 k V/m) when the current varies from 20 k A–80 k A.The homogeneous external magnetic field has little effect on the distribution of particles in the near-cathode sheath core,but the electron number density at the near-cathode sheath periphery can increase as the magnetic field increases and the homogeneous external magnetic field will lead to arc diffusion. The validity of the numerical model can be proven by comparison with the experiment.
文摘This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the high voltage circuit breaker during its close-open operating cycle. Using real time measurements of currents/voltages and angles during the close-opening cycle of high voltage generator circuit breaker and the impact of the dc component of current in context of interrupting large magnitude of current from the circuit breaker. In addition, the paper describes a study case model and the results of simulations performed using the software EMTP-ATP of an actual incident that occurred during the inadvertent synchronization of a large 339 MW, 24 kV generator to the grid.
基金supported by SGCC Scientific and Technological Project(52110116004W)
文摘Firstly, relevant stress properties of millisecond level breaking process and microsecond level commutation process of hybrid HVDC circuit breaker are studied in detail on the basis of the analysis for the application environment and topological structure and operating principles of hybrid circuit breakers, and key stress parameters in transient state process of two time dimensions are extracted. The established digital simulation circuit for PSCAD/EMTDC device-level operation of the circuit breaker has verified the stress properties of millisecond level breaking process and microsecond level commutation process. Then, equivalent test method, circuits and parameters based on LC power supply are proposed on the basis of stress extraction. Finally, the results of implemented breaking tests for complete 200 kV circuit breaker, 100 kV and 50 kV circuit breaker units, as well as single power electronic module have verified the accuracy of the simulation circuit and mathematical analysis. The result of this paper can be a guide to electrical structure and test system design of hybrid HVDC circuit breaker.
基金This project is funded by the Dongying Science Development Fund Project(DJ2021013).
文摘Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.
文摘Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system.
文摘如何对直流故障电流进行有效抑制是实现柔性直流电网大规模发展的关键。为此,研究模块化多电平变换器(modular multilevel converter,MMC)的控制方法,提出一种针对半桥型MMC的两段式限流保护策略,通过减少子模块的投入数目来降低换流站直流出口电压,达到限制短路电流的目的。首先,介绍MMC的拓扑结构及基于MMC的高压直流输电(MMC based high voltage direct current,MMC-HVDC)系统控制策略;其次,分析两段式限流保护策略的原理与直流故障电流特性,介绍MMC-HVDC系统的直流故障保护策略;最后,通过双端MMC-HVDC系统仿真实验,对所提限流保护策略的有效性进行验证。仿真结果表明,两段式限流保护策略可以有效降低断路器开断电流和吸收能量,节约成本。
基金National Natural Science Foundation of China(No.51977002)the Third International Symposium on Insulation and Discharge Computation for Power Equipment(IDCOMPU2021).
文摘This work is based on a direct current(DC)natural current commutation topology,which uses load-carrying branch contacts carrying rated current and multiple sets of series arcing branch contacts in parallel to achieve circuit breaking.The proposed topology can meet the new requirements of higher voltage DC switches in aviation,aerospace,energy and other fields.First,a magneto-hydrodynamic arc model is built using COMSOL Multiphysics,and the different arc breaking characteristics of the arcing branch contacts in different gas environments are simulated.Then,a voltage uniformity coefficient is used to measure the voltage sharing effect in the process of dynamic interruption.In order to solve the dispersion of arcing contact action,a structural control method is adopted to improve the voltage uniformity coefficient.The uniform voltage distribution can improve the breaking capacity and electrical life of the series connection structure.
基金supported by the Science and Technology Project of State Grid Corporation of China under Grant 520201210025。
文摘The hybrid dc circuit breaker(HCB)has the advantages of fast action speed and low operating loss,which is an idealmethod for fault isolation ofmulti-terminal dc grids.Formulti-terminal dc grids that transmit power through overhead lines,HCBs are required to have reclosing capability due to the high fault probability and the fact that most of the faults are temporary faults.To avoid the secondary fault strike and equipment damage that may be caused by the reclosing of the HCB when the permanent fault occurs,an adaptive reclosing scheme based on traveling wave injection is proposed in this paper.The scheme injects traveling wave signal into the fault dc line through the additionally configured auxiliary discharge branch in the HCB,and then uses the reflection characteristic of the traveling wave signal on the dc line to identify temporary and permanent faults,to be able to realize fast reclosing when the temporary fault occurs and reliably avoid reclosing after the permanent fault occurs.The test results in the simulation model of the four-terminal dc grid show that the proposed adaptive reclosing scheme can quickly and reliably identify temporary and permanent faults,greatly shorten the power outage time of temporary faults.In addition,it has the advantages of easiness to implement,high reliability,robustness to high-resistance fault and no dead zone,etc.
基金supported in part by Hunan Provincial Natural Science Foundation of China(No.2021JJ40172).
文摘Solid-state circuit breakers(SSCBs)are critical components in the protection of medium-voltage DC distribution networks to facilitate arc-free,fast and reliable isolation of DC faults.However,limited by the capacity of a single semiconductor device,using semi-conductor-based SSCBs at high voltage is challenging.This study presents the details of a 1.5 kV,63 A medi-um-voltage SSCB,composed primarily of a solid-state switch based on three cascaded normally-on silicon car-bide(SiC)junction field-effect transistors(JFETs)and a low-cost programmable gate drive circuit.Dynamic and static voltage sharing among the cascaded SiC JFETs of the SSCB during fault isolation is realized using the pro-posed gate drive circuit.The selection conditions for the key parameters of the SSCB gate driver are also analyzed.Additionally,an improved pulse-width modulation cur-rent-limiting protection solution is proposed to identify the permanent overcurrent and transient inrush current associated with capacitive load startup in a DC distribu-tion network.Using the developed SSCB prototype and the fault test system,experimental results are obtained to validate the fault response performance of the SSCB.Index Terms—Solid-state circuit breaker,DC distribu-tion network,SiC JFET,voltage balancing,inrush current.
基金supported by National Natural Science Foundation of China (Nos.51177124,51007072)the Doctoral Foundation of Ministry of Education of China (No.20110201120069)
文摘This paper focuses on the numerical investigation of arc plasma behavior during arc commutation process in a medium-voltage direct current circuit breaker (DCCB) contact system. A three-dimensional magneto-hydrodynamic (MHD) model of air arc plasma in the contact system of a DCCB is developed, based on commercial software FLUENT. Coupled electromagnetic and gas dynamic interactions are considered as usual, and a thin layer of nonlinear electrical resistance elements is used to represent the voltage drop of plasma sheath and the formation of new arc root. The distributions of pressure, temperature, gas flow and current density of arc plasma in arc region are calculated. The simulation results indicate that the pressure distribution related to the contact system has a strong effect on the arc commutation process, arising from the change of electrical conductivity in the arc root region. In DCCB contact system, the pressure of arc root region will be concentrated and higher if the space above the moving contact is enclosed, which is not good for arc root commutation. However, when the region is opened, the pressure distribution would be lower and more evenly, which is favorable for the arc root commutation.
基金supported by the 2022 Open funding of the State Key Laboratory of Electrical Insulation and Power Equipment(EIPE22211)the National Natural Science Foundation of China,“Research Fund for International Young Scientist(RFIS-1)”,Project:52150410419the 2021 Jiangsu“Shuang-Chuang Doctor(Mass Innovation and Entrepreneurship)Talent Program”,Fund:JSSCBS20211187.
文摘Environmental issues associated with the aviation industry are getting more attention as air traffic increases.Stringent standards are imposed for fuel consumption and pollution emissions for next-generation aircraft.Superconducting electrical propulsion aircraft(SEPA)have been seen as an efficient way to achieve this goal.High-temperature superconducting(HTS)devices are extensively used in the power system to supply enormous energy.Power is distributed to the different loads via a DC distribution network.However,it will generate an inrush current over ten times higher than the rated current in short-circuit state,which is very harmful to the system.Therefore,it is essential to adopt an appropriate protection scheme.This paper discusses one protection scheme that combines DC vacuum circuit breakers(DC VCB)and resistive superconducting current limiters(RSFCL)for superconducting aircraft applications.Considering problems of cost and loss,the auxiliary capacitor is pre-charged by system voltage,and mechanical elements extinguish the arc.Furthermore,combined with RSFCL,the interrupting environment is fully improved.RSFCL limits fault current,and then the VCB breaks this limited current based on creating an artificial current zero(ACZ).The prospective rated power is 8MW,rated voltage and current are 4 kV and 1 kA,respectively.In this paper,we discuss and simulate switching devices that protect SEPA.The interrupting performance of the circuit breaker is analysed in the DC short-circuit fault that occurs on the transmission line.Finally,the residual energy consumption of different situations is calculated.A comparison is made between using RSFCL with metal oxide varistor(MOV)and just using MOV.The scheme with RSFCL shows a significant advantage in energy consumption.